Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Electron microscopy holdings of the Protein Data Bank: the impact of the resolution revolution, new validation tools, and implications for the future

Abstract As a discipline, structural biology has been transformed by the three-dimensional electron microscopy (3DEM) “Resolution Revolution” made possible by convergence of robust cryo-preservation of vitrified biological materials, sample handling systems, and measurement stages operating a liquid nitrogen temperature, improvements in electron optics that preserve phase information at the atomic level, direct electron detectors (DEDs), high-speed computing with graphics processing units, and rapid advances in data acquisition and processing software. 3DEM structure information (atomic coordinates and related metadata) are archived in the open-access Protein Data Bank (PDB), which currently holds more than 11,000 3DEM structures of proteins and nucleic acids, and their complexes with one another and small-molecule ligands (~ 6% of the archive). Underlying experimental data (3DEM density maps and related metadata) are stored in the Electron Microscopy Data Bank (EMDB), which currently holds more than 21,000 3DEM density maps. After describing the history of the PDB and the Worldwide Protein Data Bank (wwPDB) partnership, which jointly manages both the PDB and EMDB archives, this review examines the origins of the resolution revolution and analyzes its impact on structural biology viewed through the lens of PDB holdings. Six areas of focus exemplifying the impact of 3DEM across the biosciences are discussed in detail (icosahedral viruses, ribosomes, integral membrane proteins, SARS-CoV-2 spike proteins, cryogenic electron tomography, and integrative structure determination combining 3DEM with complementary biophysical measurement techniques), followed by a review of 3DEM structure validation by the wwPDB that underscores the importance of community engagement.

Burley, Stephen K. (ORCID:0000000224879713)↗

MWPC prototyping and performance test for the STAR inner TPC upgrade

A new prototype of STAR inner Time Projection Chamber (iTPC) MWPC sector has been fabricated and tested in an X-ray test system. The wire chamber built at Shandong University has a wire tension precision better than 6% and wire pitch precision better than 10 μm. The gas gain uniformity and energy resolution are measured to be better than 1% (RMS) and 20% (FWHM), respectively, using an 55 Fe X-ray source. The iTPC upgrade project is to replace all 24 STAR TPC inner sectors as a crucial detector upgrade for the RHIC beam energy scan phase II program. Furthermore, the test results show that the constructed iTPC prototype meets all project requirements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improvement of the Determination of the WIMP Mass from Direct Dark Matter Detection Data

Weakly Interacting Massive Particles (WIMPs) are one of the leading candidates for Dark Matter. We developed a model--independent method for determining the WIMP mass by using data (i.e., measured recoil energies) of direct detection experiments. Our method is independent of the as yet unknown WIMP density near the Earth, of the form of the WIMP velocity distribution, as well as of the WIMP-nucleus cross section. It requires however positive signals from at least two detectors with different target nuclei. At the first phase of this work we found a systematic deviation of the reconstructed WIMP mass from the real one for heavy WIMPs. Now we improved this method so that this deviation can be strongly reduced for even very high WIMP mass. The statistical error of the reconstructed mass has also been reduced. In a background-free environment, a WIMP mass of {approx}50 GeV could in principle be determined with an error of {approx}35% with only 2x50 events.

79 ASTRONOMY AND ASTROPHYSICS↗

Refracting Roentgen's rays: Propagation-based x-ray phase contrast for biomedical imaging

Absorption-contrast x-ray imaging serves to visualize the variation in x-ray attenuation within the volume of a given sample, whereas phase contrast allows one to visualize variations in x-ray refractive index. The former imaging mechanism has been well known and widely utilized since the time of Roentgen's Nobel prize winning work, whereas the latter mechanism--sought for, but not found, by Roentgen himself--has laid the foundation for a revolution in x-ray imaging which is the central topic of this review. We consider the physical imaging mechanisms underlying both absorption contrast and phase contrast, together with the associated inverse problem of how one may obtain quantitative two- or three-dimensional information regarding a sample, given one or more phase-contrast images of the same. Practical questions are considered, regarding optimized phase-contrast imaging geometries as a function of detector resolution, source size, x-ray spectrum, and dose. Experimental examples pertaining to biomedical applications are given, and prospects for the future outlined.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Numerical Simulation Of The Pulse Sequence Reconstruction in AC Biased TESs With a {beta} Source

We study the response of micro-calorimeters based on Ir/Au TESs biased by an AC voltage in the MHz range to the power input generated by beta emission in a Re source thermally connected to the calorimeter itself. The micro-calorimeter is assumed to work at -80 mK, and the energy pulses corresponding to the beta emission have an energy distributed between zero and 2.58 KeV. In this numerical simulation the TES is inserted in a RLC resonating circuit, with a low quality factor. The thermal conductivities between the source and the calorimeter and that from the calorimeter to the heat sink are non-linear. The superconducting to normal transition of the TES is described by a realistic non-linear model. The AC current at the carrier frequency, modulated by the changing resistance of the TES, is demodulated and the output is filtered. The resulting signal is analyzed to deduce the attainable time resolution and the linearity of the response.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impedance Measurement of a Gamma-Ray TES Calorimeter with a Bulk Sn Absorber

We performed complex impedance measurements with a Ti/Au-based gamma-ray TES calorimeter with a bulk Sn absorber. Excellent energy resolution of 38.4{+-}0.9eV at 60 keV was observed. The impedance of the calorimeter can be well explained by a two-body thermal model. We investigated the behavior of the parameters of the calorimeter during the superconducting-to-normal transition. We confirmed that C and G{sub a} are in good agreement with the predicted values. We performed a noise analysis and found several excess noise components, as well as internal thermal fluctuation noise (ITFN) term due to the thermal conductance between the Sn absorber and the Ti/Au TES. Dominanting the noise is an excess noise having a similar frequency dependence to the phonon noise and the ITFN noise.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A step-wise steerable source of illumination for low-noise “Violin-Mode” shadow sensors, intended for use in interferometric gravitational wave detectors

A steerable low-noise source of illumination is described for shadow-sensors having a displacement sensitivity of ∼100 pm (rms)/√Hz, at 500 Hz, over a measuring span of at least ±0.5 mm. These sensors were designed to detect lateral “Violin-Mode” resonances in the highly tensioned fused-silica suspension fibres of the test-masses/mirrors for the Advanced Laser Interferometer Gravitational Wave Observatory gravitational wave detectors. The shadow sensors—one intended for each of the four fibres in a suspension—comprised a source of Near InfraRed (NIR) radiation (emitter) and a differential shadow-displacement sensor (detector), these bracketing the fibre under test. The suspension fibres themselves were approximately 600 mm long by 0.4 mm in diameter, and when illuminated from the side, they cast narrow, vertical, shadows onto their respective detectors—these being located at an effective distance of 50 fibre diameters behind the axes of the fibres themselves. The emitter described here was designed to compensate for a significant degree of mechanical drift or creep over time in the mean position of its suspension fibre. This was achieved by employing five adjacent columns of 8 × miniature NIR LEDs (Light Emitting Diodes, λ = 890 nm), with one column being activated at a time. When used in conjunction with a “reverse Galilean” telescope, the LED sources allowed the collimated beam from the emitter to be steered azimuthally in fine angular increments (0.65°), causing the fibre’s shadow to move laterally, in a step-wise manner, across the plane of its facing detector. Each step in shadow position was approximately 0.23 mm in size, and this allowed the fibre’s shadow to be re-centred, so as to bridge once again both elements of its photodiode detector—even if the fibre was off-centred by as much as ±0.5 mm. Re-centring allowed Violin-Mode vibrations of the fibre to be sensed once again as differential AC photocurrents, these flowing in anti-phase in the two elements of the “split-photodiode” detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative spatiotemporal density evolution of aluminum heated purely by monochromatic electrons

A spatially resolved air-wedge shearing interferometer and shadowgraph diagnostic provides measurements of electron density with a resolution of ∼40 μm. A ∼100-ns-long, monoenergetic electron bunch at 19.8 MeV and a current of 1.4 kA (8.5×1014 e−) heats 100-μm-thick aluminum (Al) foils in a 1-mm-spot to Te∼1 eV. A 5-ns-long, ∼60 mJ, frequency doubled Nd:YAG laser probes the dense Al plasma. Electron densities up to 1020cm−3 are resolved; the maximum resolvable density is limited by opacity, transmission, and spatial fringe density achievable with the detector. This diagnostic provides measurements of the total phase shift, transmission, and electron density. Several measurements at different time slices provide the ability to determine the velocity of the leading edge of the shadowgraph and compare it to the motion of different density shells. These measurements are also compared to radiation hydrodynamics simulations. A rough quantitative agreement is shown between the hydro simulations and the measurements; there are differences in the exact density distributions.

Coleman, J. E. (ORCID:0000000308873757)↗

Exploring the early Universe with Gaia and Theia

It has recently been pointed out that Gaia is capable of detecting a stochastic gravitational wave background in the sensitivity band between the frequency of pulsar timing arrays and LISA. Here, we argue that Gaia and Theia have great potential for early universe cosmology, since such a frequency range is ideal for probing phase transitions in asymmetric dark matter, SIMP and the cosmological QCD transition. Furthermore, there is the potential for detecting primordial black holes in the solar mass range produced during such an early universe transition and distinguish them from those expected from the QCD epoch. Finally, we discuss the potential for Gaia and Theia to probe topological defects and the ability of Gaia to potentially shed light on the recent NANOGrav results.

79 ASTRONOMY AND ASTROPHYSICS↗

The track-length extension fitting algorithm for energy measurement of interacting particles in liquid argon TPCs and its performance with ProtoDUNE-SP data

This paper introduces a novel track-length extension fitting algorithm for measuring the kinetic energies of inelastically interacting particles in liquid argon time projection chambers (LArTPCs). The algorithm finds the most probable offset in track length for a track-like object by comparing the measured ionization density as a function of position with a theoretical prediction of the energy loss as a function of the energy, including models of electron recombination and detector response. The algorithm can be used to measure the energies of particles that interact before they stop, such as charged pions that are absorbed by argon nuclei. The algorithm's energy measurement resolutions and fractional biases are presented as functions of particle kinetic energy and number of track hits using samples of stopping secondary charged pions in data collected by the ProtoDUNE-SP detector, and also in a detailed simulation. Additional studies describe the impact of the dE/dx model on energy measurement performance. The method described in this paper to characterize the energy measurement performance can be repeated in any LArTPC experiment using stopping secondary charged pions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of dark matter microhalos on signatures for direct and indirect detection

Detecting dark matter as it streams through detectors on Earth relies on knowledge of its phase space density on a scale comparable to the size of our Solar System. Numerical simulations predict that our galactic halo contains an enormous hierarchy of substructures, streams and caustics, the remnants of the merging hierarchy that began with tiny Earth-mass microhalos. If these bound or coherent structures persist until the present time, they could dramatically alter signatures for the detection of weakly interacting elementary particle dark matter. Using numerical simulations that follow the coarse grained tidal disruption within the Galactic potential and fine grained heating from stellar encounters, we find that microhalos, streams, and caustics have a negligible likelihood of impacting direct detection signatures implying that dark matter constraints derived using simple smooth halo models are relatively robust. We also find that many dense central cusps survive, yielding a small enhancement in the signal for indirect detection experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Skipper CCD Parameter Optimization with ML

The development of novel detectors faces a bottleneck in the 'parameter selection' phase. A significant amount of a scientist's time must be spent characterizing and testing various parameters in order to optimize them for different science goals. This process can be streamlined with closed-loop Bayesian Optimization (BO), using Gaussian Processes through live measurements on the device. In this project, we demonstrate the effectiveness of this method in parameter optimization on Skipper CCDs and its potential to be fully automated.

Hope, Andrew [Michigan Tech. U.]↗

The DUNE Vertical Drift Photon Detection System

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino experiment designed to mainly investigate oscillation parameters, supernova physics and proton decay. Its far detector will be composed of four liquid argon time projection chamber (LArTPC) underground modules, in South Dakota-USA, which will detect a neutrino beam produced at Fermilab, 1300 km away, where a near detector will be in place. The second DUNE far detector module, Vertical Drift, will be a single phase LArTPC with electron drift along the vertical axis with two volumes of 13.5 m x 6.5 m x 60 m dimensions separated by a cathode plane. The charge collection will be performed by two anode planes placed at the top and bottom of the module, each composed by stacked layers of a perforated PCB technology with electrode strips. The photon detection system (PDS) will make use of large size X-Arapuca tiles distributed over three detection planes. One plane will consist of a horizontal arrangement of double sided tiles installed on the high voltage cathode plane and two vertical planes, each placed on the longest cryostat membrane walls. A light active coverage of 14.8% over the cathode and 7.4% over the laterals should allow improvements in the low energy physics range that can be probed in DUNE, especially regarding supernova neutrinos (~10 MeV). We present the initial characterization of the Vertical Drift PDS using a Monte Carlo simulation and preliminary studies on its reconstruction capabilities at the MeV scale. The information obtained with the PDS alone should allow determination of a neutrino interaction region with a precision of at least 65 cm for events with deposited energy above 5 MeV and the deposited energy can be reconstructed with precision better than 10%, both at the center of the volume.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of 750 Large Area Photomultipliers for the KM3NeT-Italia towers

The KM3NeT European experiment aims to construct a large volume underwater neutrino telescope, in the depths of the Mediterranean Sea. Thanks to a dedicated funding by the Italian Ministry of Education, University and Research, in its first phase named KM3NeT-Italia, an 8-towers detector is under construction, equipped with 672 optical sensors. The detection element of the telescope, the 'optical module', is composed by a 13-inch high-pressure glass-vessel that contains a single 10-inch photomultiplier. As the key sensor, all the characteristics of the photomultiplier have a severe impact on the performance of the whole detector. The selected photomultiplier was the 10-inch R7081 PMT produced by Hamamatsu. In the frame of the optical modules mass production, performed in the INFN-LNS site of Catania, 750 photomultipliers have been tested by means of a dedicated test bench. The paper deals with the main results obtained from the massive photomultipliers measurements, which exhibited that such kind of devices comply with the general requirements imposed by the project. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Test Results of the Luminosity Monitors for the LHC

The Luminosity Monitor for the LHC has been built at LBNL and will be operational in the LHC during the upcoming run. The device, a gas ionization chamber, is installed in the high luminosity regions (those dedicated to the ATLAS and CMS experiments) and capable to resolve bunch-by-bunch luminosity as well as survive extreme levels of radiation. During the experimental R&D phase of its design, a prototype of this detector has been tested extensively at the ALS, in RHIC as well as in the SPS. Results of these experiments are presented here.

43 PARTICLE ACCELERATORS↗

Digital I/Q demodulation for KSTAR ion cyclotron range of frequency system

An ion cyclotron range of frequency system requires rf diagnostics for a rf-plasma coupling or for maintaining a correct operation. A detector based on a digital I/Q demodulation technique collects the rf amplitude and phase at the same time without errors from the I/Q imbalance inherent in an analog counterpart. The theory of such a detector was studied and implemented for the first campaign of the KSTAR tokamak. Experimental results of the rf and other diagnostics are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗