Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Notes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Note: A novel design of a microwave feed for a microwave frequency standard with a linear ion trap

Linear ion traps are important tools in many applications, particularly in mass spectrum analyzers and frequency standards. Here a novel design of a microwave feed integrated into one electrode of a linear quadrupole ion trap is demonstrated for the application of a microwave frequency standard based on cadmium ions. The mechanical structure of the microwave feed is compact and easy to build. The ion trap integrated with this microwave feed is successfully applied to measure the hyperfine splitting of the ground state of {sup 113}Cd{sup +}, thus demonstrating the practicality and reliability of the microwave feed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Note: Simple vacuum feedthrough for optical fiber with SubMiniature version A connectors at both ends

We present a simple way to insert an optical fiber, with existing standard SubMiniature version A connectors on both ends into a vacuum system. The fitting is tested in scanning electron microscope, at working pressures down to 2 × 10{sup −5} mbar for cathodoluminescent measurements. With slight modifications this fitting could be successfully adapted for optical fiber insertion into pressurized systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: High turn density magnetic coils with improved low pressure water cooling for use in atom optics

We describe a magnetic coil design utilizing concentrically wound electro-magnetic insulating (EMI) foil (25.4 μm Kapton backing and 127 μm thick layers). The magnetic coils are easily configurable for different coil sizes, while providing large surfaces for low-pressure (0.12 bar) water cooling. The coils have turn densities of ∼5 mm{sup −1} and achieve a maximum of 377 G at 2.1 kW driving power, measured at a distance 37.9 mm from the axial center of the coil. The coils achieve a steady-state temperature increase of 36.7°C/kW.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Automated optical focusing on encapsulated devices for scanning light stimulation systems

Recently, a scanning light stimulation system with an automated, adaptive focus correction during the measurement was introduced. Here, its application on encapsulated devices is discussed. This includes the changes an encapsulating optical medium introduces to the focusing process as well as to the subsequent light stimulation measurement. Further, the focusing method is modified to compensate for the influence of refraction and to maintain a minimum beam diameter on the sample surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Magnification of a polarization angle with a Littrow layout brazed grating

A new method to magnify a small polarization angle with brazed gratings has been developed. In the method, difference in diffraction efficiency for S and P polarization components is used. The magnification dependence on the incident angle can be small by arranging the grating in Littrow layout. A magnification with a factor ∼2.7 has been demonstrated for a 10.6 μm CO{sub 2} laser beam as expected from a calculation. The method is applicable in many polarimetry fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: On the generation of sub-300 keV flash-X-rays using rod-pinch diode: An experimental investigation

Generation of flash X-rays (FXRs) at less than 500 keV is described with emphasis on experimental investigation. The pulser is a Tesla transformer-Water transmission line based pulsed power generator operating in double resonance mode to power a rod-pinch diode. The configuration of aspect ratio reported here falls much below the normally reported ratios for the rod-pinch diode operation. Experimental investigation at such low pulsed voltage has revealed “flowering” of the anode tip and “pitting” of the perspex window. A possible explanation in terms of Lorentz body force is discussed rather than the pinch mechanism generally suggested in literature. The experimental investigation for the FXR generation is corroborated by measuring the radiation dose using CaSO{sub 4} (Dy) thermo luminescent dosimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Reliable low-vibration piezo-mechanical shutter

We present a mechanical shutter based on a bending piezo-actuator. The shutter features an active aperture of about 2 mm, allowing for full extinction and lossless transmission of a beam. Acoustic noise and mechanical vibrations produced are very low and the shutter is outstandingly long-lived; a test device has undergone 20 × 10{sup 6} cycles without breaking. A reflector makes the shutter capable of reliably interrupting a beam with at least 2 W of cw power at 780 nm. The shutter is well suited to create pulses as short as 16 ms, while pulse lengths down to 1 ms are possible. The rise and fall times are approximately 120 µs, with a delay of 2 ms. Jitter stays below 10 µs, while long-term drifts stay well below 500 µs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: High density pulsed molecular beam for cold ion chemistry

A recent expansion of cold and ultracold molecule applications has led to renewed focus on molecular species preparation under ultrahigh vacuum conditions. Meanwhile, molecular beams have been used to study gas phase chemical reactions for decades. In this paper, we describe an apparatus that uses pulsed molecular beam technology to achieve high local gas densities, leading to faster reaction rates with cold trapped ions. We characterize the beam's spatial profile using the trapped ions themselves. This apparatus could be used for preparation of molecular species by reactions requiring excitation of trapped ion precursors to states with short lifetimes or for obtaining a high reaction rate with minimal increase of background chamber pressure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Longitudinally excited N{sub 2} laser with low beam divergence

We developed a longitudinally excited N{sub 2} laser (337 nm) with low beam divergence without collimator lenses. The N{sub 2} laser consisted of a 30 cm long Pyrex glass tube with an inner diameter of 2.5 mm, a normal stable resonator formed by flat mirrors, and a simple, novel driver circuit. At a N{sub 2} gas pressure of 0.4 kPa and a repetition rate of 40 Hz, the N{sub 2} laser produced a circular beam with an output energy of 2.6 μJ and a low full-angle beam divergence of 0.29 mrad due to the uniform discharge formed by the longitudinal excitation scheme, the long cavity with the small aperture, and the low-input energy oscillation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Enhancement of the extreme ultraviolet emission from a potassium plasma by dual laser irradiation

Emission spectra from multiply charged potassium ions ranging from K{sup 3+} to K{sup 5+} have been obtained in the extreme ultraviolet (EUV) spectral region. A strong emission feature peaking around 38 nm, corresponding to a photon energy of 32.6 eV, is the dominant spectral feature at time-averaged electron temperatures in the range of 8−12 eV. The variation of this emission with laser intensity and the effects of pre-pulses on the relative conversion efficiency (CE) have been explored experimentally and indicate that an enhancement of about 30% in EUV CE is readily attainable.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Effect of photodiode aluminum cathode frame on spectral sensitivity in the soft x-ray energy band

Silicon photodiodes used for soft x-ray detection typically have a thin metal electrode partially covering the active area of the photodiode, which subtly alters the spectral sensitivity of the photodiode. As a specific example, AXUV4BST photodiodes from International Radiation Detectors have a 1.0 μm thick aluminum frame covering 19% of the active area of the photodiode, which attenuates the measured x-ray signal below ∼6 keV. This effect has a small systematic impact on the electron temperature calculated from measurements of soft x-ray bremsstrahlung emission from a high-temperature plasma. Although the systematic error introduced by the aluminum frame is only a few percent in typical experimental conditions on the Madison Symmetric Torus, it may be more significant for other instruments that use similar detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗