The fatigue strength of members containing cracks.
Loss of fatigue life due to crack, crack-like defect or sharp notch
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Loss of fatigue life due to crack, crack-like defect or sharp notch
Ultrasonic system for detection and measurement of fatigue cracks in notched steel alloys
Relative strengths of notched single-layer and multilayer stainless steel pressure vessels at cryogenic temperatures
Elevated-temperature fatigue data on notched and smooth specimens of refractory alloys in ultrahigh vacuum environments
Cyclic plastic stresses in notched aluminum alloy sheets under constant-amplitude repeated tension and reversed loading - fatigue life data
Variable amplitude axial load fatigue test on notched aluminum alloy specimens - aircraft component testing
Lightweight, wrought magnesium alloys for high strength and ductility and low notch sensitivity applications at cryogenic temperatures
Design and testing of crack notched specimens for determining resistance of materials to unstable mode crack extension under plain strain conditions
Hydrogen embrittlement of alloy cathodically charged and notched tensile metals
Formation of fatigue cracks in center notched sheet specimens of various metals ultrasonically tested for axial tensile fatigue
Fatigue testing of refractory alloys to determine effect of notch geometry on fatigue strength
Effects of sheet width and notch length on calculated fracture toughness of low interstitial titanium alloy sheet
Effects of high initial tensile and compressive loads and elevated temperatures on room temperature fatigue life of notched titanium alloy sheets
The effects of control mode and test rate on the measured fracture toughness of ceramics were evaluated by using chevron-notched flexure specimens in accordance with ASTM C1421. The use of stroke control gave consistent results with about 2% (statistically insignificant) variation in measured fracture toughness for a very wide range of rates (0.005 to 0.5 mm/min). Use of strain or crack mouth opening displacement (CMOD) control gave approx. 5% (statistically significant) variation over a very wide range of rates (1 to 80 μm/m/s), with the measurements being a function of rate. However, the rate effect was eliminated by use of dry nitrogen, implying a stress corrosion effect rather than a stability effect. With the use of a nitrogen environment during strain controlled tests, fracture toughness values were within about 1% over a wide range of rates (1 to 80 micons/m/s). CMOD or strain control did allow stable crack extension well past maximum force, and thus is preferred for energy calculations. The effort is being used to confirm recommendations in ASTM Test Method C1421 on fracture toughness measurement.
A single sheet of nickel-titanium (NiTi) shape memory alloy (SMA) was introduced within an IM7/8552 polymer matrix composite (PMC) panel in conjunction with multiple thin film adhesives to promote the interfacial bond strength between the SMA and PMC. End notched flexure (ENF) testing was performed in accordance to ASTM D7905 method for evaluation of mode II interlaminar fracture toughness (GIIC) of unidirectional fiber-reinforced polymer matrix composites. Acoustic emissions (AE) were monitored during testing with two acoustic sensors attached to the specimens. The composite panels were subjected to C-scan before testing, and examined using optical and scanning electron microscopy techniques after part failure. GIIC values for the control composite samples were found to be higher than those of samples with embedded SMA sheets. The presence of adhesives bonded to SMA sheets further diminished the GIIC values. AE values revealed poor bonding of the panels, with little to no signals during testing.
The effects of control mode and rate on the fracture toughness of ceramics were measured by using chevron-notched flexure specimen in accordance with ASTM C1421. The use of stroke control gave consistent results with about 2% variation in measured fracture toughness for a very wide range of rates (0.005 to 0.5 mm/min). Use of strain or CMOD control gave ~5% variation over a very wide range of rates, with the measurements being a function of rate. However, the effect was eliminated by use of dry nitrogen, implying a stress corrosion effect rather than a stability effect. With the use of nitrogen for strain control, fracture toughness values were within about 1% over a wide range of rates (1 to 80 /s). CMOD or strain control did allow stable crack extension well past maximum load, and thus is preferred for energy calculations. The effort is being used to confirm recommendations in ASTM International standard C1421 on fracture toughness measurement.
A single sheet of nickel-titanium (NiTi) shape memory alloy (SMA) was introduced within an IM7/8552 polymer matrix composite (PMC) panel in conjunction with multiple thin film adhesives to promote the interfacial bond strength between the SMA and PMC. End notched flexure (ENF) testing was performed in accordance to ASTM D7905 method for evaluation of mode II interlaminar fracture toughness (GIIC) of unidirectional fiber-reinforced polymer matrix composites. Acoustic emissions (AE) were monitored during testing with two acoustic sensors attached to the specimens. The composite panels examined using scanning electron microscopy techniques after part failure. GIIC values for the control composite samples were found to be higher than those of samples with embedded SMA sheets. The presence of adhesives bonded to SMA sheets further diminished the GIIC values. AE values revealed poor bonding of the panels, with little to no signals during testing.
To replace the classical hollow sphere, a compact reference black body has been constructed from stacked razor blades. Treated with a deposit of black oxide on the surfaces or notches between the upper edges of the blades, the device is useful over a wide range of incident angles.