Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Identifying Neutron Irradiation in Space to Mitigate Bio-Medical Effects

Ubiquitous GCR high energy particles >1 GeV is primary concern • Medical effects compounded by ionizing dose of radiation from energetic particles- cancer, mutations, microbiome changes • Cancer induction and effects are irreversible after initiation • Long term space radiation exposure is cancer promoting but reversible Secondary GCR and Solar induced neutron spallation is a concern • Produced by interactions with space craft materials, EVA and planetary surfaces • Neutron Quality Factor is 10x that of beta, x-ray or gamma rays Space isn’t friendly to life or electronics! Real-time charged particle and EARLY neutron detection are required. Traveling fast or digging deep are the best protection. Nuclear space propulsion through LENR/LCF/Solid-State Fusion is a good bet!

space medicine↗

A Plutonium Mass Uncertainty Assessment Using a Cherenkov-Based Neutron Multiplicity Water Detector

We present a new analysis of the sensitivity of a water Cherenkov-based neutron multiplicity counter for nondestructive assay of trace quantities of 240 Pu. The multiplicity counter [water-based neutron detector (WaND)] contains 1.0 m 3 of water doped with 0.2% gadolinium in the form of a gadolinium salt (0.4% GdCl 3 ). It can be used for testing the presence of trace quantities of 240 Pu within a sample of unknown material by observing the correlated timing behavior of neutron capture candidates in the detector. The new analysis takes advantage of the fact that the detector is comprised almost entirely of a homogeneous medium, which permits the use of a simple model to reproduce the observed neutron capture timing behavior. Finally, the results of this analysis indicate that the detector has an absolute neutron detection efficiency of 23.4 ± 1.1% and is sensitive to a 240 Pu mass as small as 2.3 mg (at 1σ) after a 1-h data acquisition.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

The Fuel Motion Monitoring System at TREAT - Current Status and Future Plans

An important component of the United States Nuclear Fuel Safety Transient Testing Program, the Fuel Motion Monitoring System (FMMS) at Idaho National Laboratory's Transient Reactor Test Facility (TREAT) is fast-neutron hodoscope capable of imaging the location, movement, and relocation of nuclear fuel experiments under simulated transient accident conditions. The FMMS was refurbished in parallel with the TREAT restart program starting in 2014, restoring 96-channels of fast-neutron detection. Since returning to operation in 2017 the FMMS has supported many fuel safety experiments supporting accident tolerant fuel development, light-water reactor safety, space thermal nuclear propulsion fuel development, and advanced reactor research and development. In Phase 2 of the FMMS restoration. work is now under way to expand the FMMS' field-of-view by adding an additional 96 channels of fast neutron detectors to the system's hodoscope, along with an expanded data acquisition system and associated transient timing electronics. An overview of the FMSS system and its fast-neutron detectors will be presented along with examples of current FMMS imaging performance and associated information.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

β -decay half-lives and β -delayed neutron emission probabilities for several isotopes of Au, Hg, Tl, Pb, and Bi, beyond N = 126

Background: There have been measurements on roughly 230 nuclei that are β-delayed neutron emitters. They range from 8 He up to 150 La . Apart from 210 Tl, with a branching ratio of only 0.007%, no other neutron emitter has been measured beyond A = 150 . Therefore, new data are needed, particularly in the region of heavy nuclei around N = 126 , in order to guide theoretical models and help understand the formation of the third r-process peak at A ~ 195. Purpose: To measure both β-decay half-lives and neutron branching ratios of several neutron-rich Au, Hg, Tl, Pb, and Bi isotopes beyond N = 126 . Method: Ions of interest were produced by fragmentation of a 238 U beam, selected and identified via the GSI-FRS fragment separator. A stack of segmented silicon detectors (SIMBA) was used to measure ion implants and β decays. An array of 30 3 He tubes embedded in a polyethylene matrix (BELEN) was used to detect neutrons with high efficiency and selectivity. A self-triggered digital system is employed to acquire data and to enable time correlations. The latter were analyzed with an analytical model and results for the half-lives and neutron-branching ratios were derived by using the binned maximum-likelihood method. Results: Twenty new β-decay half-lives are reported for 204-206 Au, 208 – 211 Hg, 211 – 216 Tl , 215 – 218 Pb, and 218 – 220 Bi, nine of them for the first time. Neutron emission probabilities are reported for 210, 211 Hg and 211 – 216 Tl . Conclusions: The new β-decay half-lives are in good agreement with previous measurements on nuclei in this region. Lastly, the measured neutron emission probabilities are comparable to or smaller than values predicted by global models such as relativistic Hartree Bogoliubov plus the relativistic quasi-particle random phase approximation (RHB + RQRPA).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of Plasmonically Cloaked Nanoparticles

An advanced in-pile multi-parameter reactor monitoring system is being proposed in this funding opportunity. The proposed effort brings cutting edge, high-fidelity optical measurement systems into the reactor environment in an unprecedented fashion, including in-core, in-cladding and in-fuel pellet itself. Unlike instrumented leads, the proposed system provides a unique solution to a multi-parameter monitoring need in core while being minimally intrusive in the reactor core. Detector designs proposed herein can monitor fuel compression and expansion in both the radial and axial dimensions as well as monitor linear power profiles and fission rates during the operation of the reactor. In addition to pressure, stress, strain, compression, neutron flux, neutron spectra, and temperature can be observed inside the fuel bundle and fuel rod using the proposed system. The proposed research aims at developing radiation-hard, harsh-environment multi-parameter systems for insertion into the reactor environment. The proposed research holds the potential to drastically increase the fidelity and precision of in-core instrumentation with little or no impact in the neutron economy in the reactor environment while providing a measurement system capable of operation for entire operating cycles. Significant work has been done over the last few years on the use of nanoparticle-based scintillators. Through the use of metamaterials, the PIs aim to develop planar neutron detectors and large-volume neutron detectors. These detectors will have high efficiencies for neutron detection and will have a high gamma discrimination capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cross-correlation measurements with the EJ-299-33 plastic scintillator

New organic–plastic scintillation compositions have demonstrated pulse-shape discrimination (PSD) of neutrons and gamma rays. We present cross-correlation measurements of 252 Cf and mixed uranium–plutonium oxide (MOX) with the EJ-299-33 plastic scintillator. For comparison, equivalent measurements were performed with an EJ-309 liquid scintillator. Offline, digital PSD was applied to each detector. These measurements show that EJ-299-33 sacrifices a factor of 5 in neutron–neutron efficiency relative to EJ-309, but could still utilize the difference in neutron–neutron efficiency and neutron single-to-double ratio to distinguish 252 Cf from MOX. These measurements were modeled with MCNPX-PoliMi, and MPPost was used to convert the detailed collision history into simulated cross-correlation distributions. MCNPX-PoliMi predicted the measured 252 Cf cross-correlation distribution for EJ-309 to within 10%. Greater photon uncertainty in the MOX sample led to larger discrepancy in the simulated MOX cross-correlation distribution. In conclusion, the modeled EJ-299-33 plastic also gives reasonable agreement with measured cross-correlation distributions, although the MCNPX-PoliMi model appears to under-predict the neutron detection efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Examination of Digital-Delay Rossi-$\alpha$ for 252 Cf-Driven Highly Enriched Uranium Using Organic Scintillators

Neutron noise techniques constitute several analysis methods applicable to non-destructive assay. One technique is the Rossi-α method to calculate the prompt neutron decay constant (α) or its inverse, the prompt neutron period (1/α), for assemblies of fissionable material. This work evaluates a high-data-throughput measurement at the National Criticality Experiments Research Center (NCERC) with organic scintillators measuring a subcritical assembly of highly enriched uranium (HEU) metal (93% 235 U). The assembly comprises hemi shells stacked together to form fully closed shells and is driven by a Cf source at the center. The assembly is a total of 59.85 kg HEU and a k eff of 0.99, according to MCNP6.2 KCODE simulations. Measurements were acquired with a three-by-four array of 5.08-cm-diameter by 5.08-cm-length trans-stilbene crystals 166 cm from the assembly center. Two types of coincident binning methods are used to build the Rossi-α distribution of coincident neutron detections: A) type 1 binning, also known as any-and-all forward time differences, and B) type 1 binning with a digital-delay technique that is analogous to Orndoff’s use of delay cabling in early Rossi-alpha measurements. Method B) disregards same-detector coincidences and once all nearest time coincidences are collected between all detectors after a trigger, a time delay of 0.75 µs is implemented. The measured prompt neutron decay constants for both techniques are calculated from single exponential fits and the two methods are compared. Method A) shows an apparent timing discontinuity near 500 ns time differences. This timing discontinuity interferes with the fitting method used to calculate the prompt neutron decay constant. Method B) mitigates the artificial timing discontinuity and removes the disagreement of the fit. Future work will model the time-dependent detector response to discern why this timing discontinuity occurs, discern how Method B) reduces the amplitude of this timing discontinuity, and apply this method to critical assembly measurements to ultimately confirm the recommendation to use Method B) for high-data-throughput measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative scintillation performance of EJ-309, EJ-276, and a novel organic glass

An organic glass scintillator developed by Sandia National Laboratories was characterized in terms of its light output and pulse shape discrimination (PSD) properties and compared to commercial liquid (EJ-309) and plastic (EJ-276) organic scintillators. The electron light output was determined through relative comparison of the 137 Cs Compton edge location. The proton light yield was measured using a double time-of-flight technique at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a tunable broad-spectrum neutron source and an array of pulse-shape-discriminating observation scintillators, a continuous measurement of the proton light yield was performed for EJ-309 (200 keV–3.2 MeV), EJ-276 (170 keV–4.9 MeV), and the organic glass (50 keV–20 MeV) . Finally, the PSD properties of the organic glass, EJ-309, and EJ-276 were evaluated using an AmBe source and compared via a figure-of-merit metric. The organic glass exhibited a higher electron light output than both EJ-309 and EJ-276. Its proton light yield and PSD performance were comparable to EJ-309 and superior to that of EJ-276. Finally, with these performance characteristics, the organic glass scintillator is well poised to replace current state-of-the-art PSD-capable scintillators in a range of fast neutron detection applications.

47 OTHER INSTRUMENTATION↗

Neutron Tagging From Neutrino Interactions in DUNE-ND 2x2 Prototype

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment that aims to measure whether CP is violated in the leptonic sector (if violated, how much) and unambiguously determine the neutrino mass ordering. DUNE consists of near and far detectors that rely on liquid argon time projection chamber (LArTPC) technology to observe neutrino interactions. The near detector (ND) will be placed in Fermilab, near the neutrino source, while the far detector (FD) will be deployed in Sanford Lab, 1.5 km deep underground, which is 1300 km away from the source. LArTPCs provide excellent particle identification and calorimetry; however, detecting neutrons is challenging, as they do not leave direct ionization signals in LArTPCs. Neutrons can carry away up to 25% of the neutrino energy, introducing a significant uncertainty in DUNE measurements. The DUNE near detector (ND) features a novel modular LArTPC with pixelated charge readout, which enhances event recons truction. The modular design enables precise correlation between ionization signals and light signals in a high-rate environment, improving the identification of delayed energy depositions from neutrons in neutrino interactions. We introduce a neutron tagging technique using the 2x2 Demonstrator, a small-scale prototype of the DUNE ND LArTPC. The analysis utilizes Monte Carlo simulations and deep-learning techniques to identify neutron-induced energy depositions and reconstruct low-energy activity.

Kufatty, Georgette [Florida State U.]↗

A LiF silicon sandwich counter to measure water content of planetary surfaces

The neutron counter proposed here has a long history and was commercially available in a somewhat different form. This counter would be suitable for a rover or lander since it requires a rather long measuring time for each placement. It consists of two silicon wafer charged-particle counters with a layer of Li-6F deposited on the inner surface of one. The neutron detecting reaction is Li-6(n,H-3)He-4 in which the alpha particle and the triton are emitted from the Li-6 deposit back to back. If one of the detectors sees the alpha particle, the other will see the triton. This allows one to use a coincidence technique that virtually eliminates all background. The signals from each detector can be added together so that the total energy of the reaction, Q=4.6 MeV and the kinetic energy of the neutron, can be recorded.

Drake, D. M.↗

Neutron Activation Foil and Thermoluminescent Dosimeter Responses to a Lead Reflected Pulse of the CEA Valduc SILENE Critical Assembly

This benchmark experiment was conducted as a joint venture between the US Department of Energy (DOE) and the French Commissariat à l'Energie Atomique (CEA). Staff at the Oak Ridge National Laboratory (ORNL) in the US and the Centre de Valduc in France planned this experiment. The experiment was conducted on October 13, 2010 in the SILENE critical assembly facility at Valduc. Several other organizations contributed to this experiment and the subsequent evaluation, including CEA Saclay, Lawrence Livermore National Laboratory (LLNL), the Y-12 National Security Complex (NSC), Babcock International Group in the United Kingdom, and Los Alamos National Laboratory (LANL). The goal of this experiment was to measure neutron activation and thermoluminescent dosimeter (TLD) doses from a source similar to a fissile solution critical excursion. The resulting benchmark can be used for validation of computer codes and nuclear data libraries as required when performing analysis of criticality accident alarm systems (CAASs). A secondary goal of this experiment was to qualitatively test performance of two CAAS detectors similar to those currently and formerly in use in some US DOE facilities. The detectors tested were the CIDAS MkX and the Rocky Flats NCD-91. The CIDAS detects gammas with a Geiger-Muller tube, and the Rocky Flats detects neutrons via charged particles produced in a thin 6 LiF disc, depositing energy in a Si solid-state detector. These detectors were being evaluated to determine whether they would alarm, so they were not expected to generate benchmark quality data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Activation Foil and Thermoluminescent Dosimeter Responses to a Polyethylene Reflected Pulse of the CEA Valduc SILENE Critical Assembly

This benchmark experiment was conducted as a joint venture between the US Department of Energy (DOE) and the French Commissariat à l'Energie Atomique (CEA). Staff at the Oak Ridge National Laboratory (ORNL) in the US and the Centre de Valduc in France planned this experiment. The experiment was conducted on October 19, 2010 in the SILENE critical assembly facility at Valduc. Several other organizations contributed to this experiment and the subsequent evaluation, including CEA Saclay, Lawrence Livermore National Laboratory (LLNL), the Y-12 National Security Complex (NSC), Babcock International Group in the United Kingdom, and Los Alamos National Laboratory (LANL). The goal of this experiment was to measure neutron activation and thermoluminescent dosimeter (TLD) doses from a source similar to a fissile solution critical excursion. The resulting benchmark can be used for validation of computer codes and nuclear data libraries as required when performing analysis of criticality accident alarm systems (CAASs). A secondary goal of this experiment was to qualitatively test performance of two CAAS detectors similar to those currently and formerly in use in some US DOE facilities. The detectors tested were the CIDAS MkX and the Rocky Flats NCD-91. The CIDAS detects gammas with a Geiger-Muller tube and the Rocky Flats detects neutrons via charged particles produced in a thin 6 LiF disc depositing energy in a Si solid state detector. These detectors were being evaluated to determine whether they would alarm, so they were not expected to generate benchmark quality data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Examination of New Theory for Neutron Multiplicity Counting of Non-Point-Like Sources of Special Nuclear Material

The purpose of a nondestructive assay is to accurately verify the declared mass of special nuclear material (SNM) samples in a limited amount of time. One measurement modality is neutron multiplicity counting (NMC), which relates time-correlated neutron detection rates to the mass of SNM present. Traditional theory assumes point-like sources, which can be ill-posed for kilogram-quantity, bulk samples. Recent theory was developed to improve NMC accuracy for non-point-like samples. This work preliminarily examines the theory with measured data. The OSCAR prototype (a 3-by-4 array of 5.08-cm-thick, 5.08-cm-diameter trans-stilbene organic scintillators) measures configurations of 29.41-49.00 kg of highly enriched uranium (93wt% 235 U). Adjusted factorial moments for the emitted neutron multiplicity distributions are used to account for the shape and type of SNM being measured.

252Cf↗

Plutonium metal vs. oxide determination with the pulse-shape-discrimination-capable plastic scintillator EJ-299-33

Neutron measurements can be used to distinguish plutonium in metal or oxide form, a capability that is of great interest in nuclear nonproliferation, treaty verification, and other applications. This paper describes measurements performed on well-characterized samples of plutonium oxide and plutonium metal using the pulse-shape-discrimination-capable plastic scintillator EJ-299-33. Results are compared to those obtained with a same-sized detector cell using the liquid scintillator EJ-309. The same optimized, digital pulse shape discrimination technique is applied to both detectors and the neutron pulse height distributions are compared. Results show that the EJ-299-33 plastics can be successfully used for plutonium measurements, where the gamma ray to neutron detection ratio is much higher than for typical radioactive sources. Results also show that EJ-299-33 detectors can be used to characterize plutonium samples, specifically to discriminate between plutonium metal and oxide.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Time Projection Chambers instrumented with resistive MicroMegas for the SAND near detector of DUNE

The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino accelerator experiment aiming for precise measurements of the neutrino oscillation parameters. DUNE will include a near detector complex regrouping three different detectors among which SAND (System for on-Axis Neutrino Detection) that will be the only one permanently on the neutrino beam axis in charge of monitoring in detail the emitted neutrino beam and its stability through time, a crucial characteristic to realize accurate oscillation measurements at the percent level. SAND will reuse the superconducting magnet and the electromagnetic calorimeter of the KLOE experiment. We will describe in the following the proposal of using, as inner tracker of SAND, a large 3D matrix of 1.5cm side scintillator cubes (3DST) surrounded by 3 gaseous Time Projection Chambers. This setup allows to realize accurate beam monitoring combining the 3DST unprecedented capability of neutron detection and energy measurement with the high precision momentum resolution for charged particles offered by the TPCs. The proposed TPC design allows to reach spatial resolutions of a few hundreds of micrometers using 1 cm pads by deploying the resistive MicroMegas technology for the charge readout.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Boron coated straw-based neutron multiplicity counter for neutron interrogation of TRISO fueled pebbles

Pebble bed reactors (PBRs) can improve the safety and economics of the nuclear energy production. PBRs rely on TRIstructural-ISOtropic (TRISO) fuel pebbles for enhanced fission product retention. Accurate characterization of individual fuel pebbles would enable the validation of computational models, efficient use of TRISO fuel, and improve fuel accountability. Here, we have developed and tested a new neutron multiplicity counter (NMC) based on 192 boron coated straw (BCS) detectors optimized for 235 U assay in TRISO fuel. The new design yielded a singles and doubles neutron detection efficiency of 4.71% and 0.174%, respectively, and a die-away time of 16.7 μs. The NMC has a low intrinsic gamma-ray detection efficiency of 8.71 x 10 –8 at an exposure rate of 80.3 mR/h. In simulation, a high-efficiency version of the NMC encompassing 396 straws was able to estimate the 235 U in a pebble with a relative uncertainty and error both below 2% in 100 s.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurements of fast neutrons by bubble detectors

Neutron bubble detectors have been studied using Am-Be and D-D neuron sources, which give limited energy information. The Bubble Detector Spectrometer (BDS) have six different energy thresholds ranging from 10 KeV to 10 Mev. The number of bubbles obtained in each measurement is related to the dose (standardized response R) equivalent neutrons through sensitivity (b / {mu}Sv) and also with the neutron flux (neutrons per unit area) through a relationship that provided by the manufacturer. Bubble detectors were used with six different answers (0.11 b/ {mu}Sv, 0093 b/{mu}Sv, 0.14 b/{mu}Sv, 0.17 b/{mu}Sv, 0051 b/{mu}Sv). To test the response of the detectors (BDS) radiate a set of six of them with different energy threshold, with a source of Am-Be, placing them at a distance of one meter from it for a few minutes. Also, exposed to dense plasma focus Fuego Nuevo II (FN-II FPD) of ICN-UNAM, apparatus which produces fusion plasma, generating neutrons by nuclear reactions of neutrons whose energy emitting is 2.45 MeV. In this case the detectors were placed at a distance of 50 cm from the pinch at 90 Degree-Sign this was done for a certain number of shots. In both cases, the standard response is reported (Dose in {mu}Sv) for each of the six detectors representing an energy range, this response is given by the expression R{sub i}= B{sub i} / S{sub i} where B{sub i} is the number of bubbles formed in each and the detector sensitivity (S{sub i}) is given for each detector in (b / {mu}Sv). Also, reported for both cases, the detected neutron flux (n cm{sup -2}), by a given ratio and the response involves both standardized R, as the average cross section sigma. The results obtained have been compared with the spectrum of Am-Be source. From these measurements it can be concluded that with a combination of bubble detectors, with different responses is possible to measure the equivalent dose in a range of 10 to 100 {mu}Sv fields mixed neutron and gamma, and pulsed generated fusion devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Lunar Regolith as a Remote Sensing Target for the Lunar Reconnaissance Orbiter (LRO)

Of the 6 instruments and one technology demonstration aboard the LRO, only CRaTER does not measure some kind of interaction of particles with the lunar regolith. LEND detects neutron fluence that contains information about the number density of protons in the upper regolith. To infer the presence of protons, the PI must assume a model that characterizes the surface as a collection of atoms. Thus, LEND does not sense the regolith as a structure. LROC, LOLA, and LAMP sense reflected photons whose wavelength is much shorter than the median particle size in the regolith. The photons interact with electrons, either in atomic shells or in chemical bonds. These interactions occur within a nanometer or so of the surface of a particle. Thus, the particles are macroscopic objects and models of the reflection process invoke ray-tracing optics. DIVINER senses photons that have been emitted by surface particles through thermal phonon processes. The wavelengths detected by the instrument are of the same order as the median particle size, and the photons contain information on particle dimensions as well as the molecular bonds in the constituent compounds. The Mini-RF synthetic aperture radar generates and detects photons of a few centimeters wavelength that interact with the regolith as a dielectric, the dielectric properties of the particulate component being described through effective medium theory. However, the interaction with rocks (macroscopic objects of interest to geologists) can be characterized using Fresnel or Mie models of electromagnetic properties.

Mendell, Wendell W.↗