Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NEUTRON SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Deformation-dependent Tamura-Udagawa-Lenske multistep direct model

The multistep direct TUL model has been extended in order to account for nuclear deformation. The new formalism was tested in calculations of neutron emission spectra from the {sup 232}Th(n, xn) reaction. These calculations include vibration-rotational coupled channels for the inelastic scattering to low-lying collective levels, ''deformed'' multistep direct (MSD) for inelastic scattering to the continuum, multistep compound, and Hauser-Feshbach with advanced treatment of the fission channel. Prompt fission neutrons were also calculated. The comparison with experimental data shows clear improvement over the ''spherical'' MSD calculations and JEFF-3.1 and JENDL-3.3 evaluations. Similar calculational results have been obtained of neutron emission spectra from the stable deformed nuclei {sup 181}Ta and {sup 184}W.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

X-ray spectra and atmospheric structures of bursting neutron stars

Atmospheric structures and emitted X-ray spectra of bursting neutron stars are investigated. Theoretical curves are fitted to observational ones on the color temperature vs. luminosity diagram and two relations among mass, radius, and distance of the bursters are obtained. The fit of the theoretical curve to observations is statistically acceptable. Two possible sets of mass, radius, and distance to the X-ray bursts source MXB 1636-536 are derived, taking into account absorption lines at 4.1 keV, theoretical mass-radius relations of neutron star models, and the distance to the Galactic center. If the absorption line is due to Cr XX III, then M = 1.7-2.0 solar masses, R = 11-12 km, and d = 6.3-6.7 kpc, and if it is due to Fe XXV, then M = 1.8-2.1 solar masses, R = 8-10 km, and d = 5.8-6,4 kpc. The distance to the Galactic center is almost the same as that to MXB 1636-536.

Ebisuzaki, Toshikazu↗

Correlated Signal Analysis for Nuclear Emergency Response

In the context of nuclear emergency response (NER) scenarios, the critical task is to quickly identify a "black box" as a potential threat, as failing to do so could have catastrophic consequences. Techniques for passive assay of a “black box” typically include gamma-ray spectroscopy and neutron coincidence/multiplicity counting. However, there are significant challenges associated with these type of measurements. First, the presence of intervening materials can obstruct the detection of relevant signatures. Second, the presence of strong non-fission neutron sources, like (α, n) emitters, can add uncertainties to the neutron multiplicity analysis. In our LDRD-MFR Phase II work, a portable neutron spectrometer, called the Compact Fast Neutron Spectrometer (CFNS), was developed for NER applications. The CFNS system leverages information-rich neutron energy spectra to derive actionable information. This work investigates the use of correlated signals in the CFNS from special nuclear material (SNM) to characterize physical properties, such as intervening shielding material and fission to non-fission neutron contributions. In this report, the Phase II results from bulk SNM measurements at the National Criticality Experiments Research Center (NCERC) are briefly discussed along with the motivation for this work. Afterwards, simulations using the MCNPX-PoliMi transport code are discussed, which were used to expand our correlated signal study. Signal triggered analysis for neutron multiplicity extraction will also be discussed. Lastly, the use neutron-photon correlations for intervening material identification are shown, along with the use of correlated neutron energy spectra for α-ratio extraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced data analysis in inertial confinement fusion and high energy density physics

Bayesian analysis enables flexible and rigorous definition of statistical model assumptions with well-characterized propagation of uncertainties and resulting inferences for single-shot, repeated, or even cross-platform data. This approach has a strong history of application to a variety of problems in physical sciences ranging from inference of particle mass from multi-source high-energy particle data to analysis of black-hole characteristics from gravitational wave observations. The recent adoption of Bayesian statistics for analysis and design of high-energy density physics (HEDP) and inertial confinement fusion (ICF) experiments has provided invaluable gains in expert understanding and experiment performance. In this Review, we discuss the basic theory and practical application of the Bayesian statistics framework. We highlight a variety of studies from the HEDP and ICF literature, demonstrating the power of this technique. Due to the computational complexity of multi-physics models needed to analyze HEDP and ICF experiments, Bayesian inference is often not computationally tractable. Two sections are devoted to a review of statistical approximations, efficient inference algorithms, and data-driven methods, such as deep-learning and dimensionality reduction, which play a significant role in enabling use of the Bayesian framework. We provide additional discussion of various applications of Bayesian and machine learning methods that appear to be sparse in the HEDP and ICF literature constituting possible next steps for the community. We conclude by highlighting community needs, the resolution of which will improve trust in data-driven methods that have proven critical for accelerating the design and discovery cycle in many application areas.

47 OTHER INSTRUMENTATION↗

SU-E-T-90: Accuracy of Calibration of Lithium-6 and -7 Enriched LiF TLDs for Neutron Measurements in High Energy Radiotherapy

Purpose: To determine the potential error involved in the interpretation of neutron measurements from medical linear accelerators (linacs) using TLD-600H and TLD-700H if standard AmBe and {sup 252}Cf neutron sources are used for calibration without proper inclusion of neutron energy spectrum information. Methods: The Kerma due to neutrons can be calculated from the energy released by various nuclear interactions (elastic and inelastic scatter, (n,α), (n,p), (n,d), (n,t), (n,2n), etc.). The response of each TLD can be considered the sum of the neutron and gamma components; each proportional to the Kerma. Using the difference between the measured TLD responses and the ratio of the calculated Kerma for each material, the neutron component of the response can be calculated. The Monte Carlo code MCNP6 has been used to calculate the neutron energy spectra resulting from photonuclear interactions in a Varian 21EX linac. TLDs have been exposed to the mixed (γ-n) field produced by a linac and AmBe and {sup 252}Cf standard neutron sources. Results: For dosimetry of neutrons from AmBe or {sup 252}Cf sources, assuming TLD-700H insensitivity to neutrons will Result in 10% or 20% overestimation of neutron doses respectively.For dosimetry of neutrons produced in a Varian 21EX, applying a calibration factor derived from a standard AmBe or {sup 252}Cf source will Result in an overestimation of neutron fluence, by as much as a factor of 47.The assumption of TLD-700H insensitivity to neutrons produced by linacs leads to a negligible error due to the extremely high Kerma ratio (600H/700H) of 3000 for the assumed neutron spectrum. Conclusion: Lithium-enriched TLDs calibrated with AmBe and/or {sup 252}Cf neutron sources are not accurate for use under the neutron energy spectrum produced by a medical linear accelerator.

60 APPLIED LIFE SCIENCES↗

THE IMPACT OF SURFACE TEMPERATURE INHOMOGENEITIES ON QUIESCENT NEUTRON STAR RADIUS MEASUREMENTS

Fitting the thermal X-ray spectra of neutron stars (NSs) in quiescent X-ray binaries can constrain the masses and radii of NSs. The effect of undetected hot spots on the spectrum, and thus on the inferred NS mass and radius, has not yet been explored for appropriate atmospheres and spectra. A hot spot would harden the observed spectrum, so that spectral modeling tends to infer radii that are too small. However, a hot spot may also produce detectable pulsations. We simulated the effects of a hot spot on the pulsed fraction and spectrum of the quiescent NSs X5 and X7 in the globular cluster 47 Tucanae, using appropriate spectra and beaming for hydrogen atmosphere models, incorporating special and general relativistic effects, and sampling a range of system angles. We searched for pulsations in archival Chandra HRC-S observations of X5 and X7, placing 90% confidence upper limits on their pulsed fractions below 16%. We use these pulsation limits to constrain the temperature differential of any hot spots, and to then constrain the effects of possible hot spots on the X-ray spectrum and the inferred radius from spectral fitting. We find that hot spots below our pulsation limit could bias the spectroscopically inferred radius downward by up to 28%. For Cen X-4 (which has deeper published pulsation searches), an undetected hot spot could bias its inferred radius downward by up to 10%. Improving constraints on pulsations from quiescent LMXBs may be essential for progress in constraining their radii.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of the scintillation mechanism in a pressurized {sup 4}He fast neutron detector using pulse shape fitting

An empirical investigation of the scintillation mechanism in a pressurized {sup 4}He gas fast neutron detector was conducted using pulse shape fitting. Scintillation signals from neutron interactions were measured and averaged to produce a single generic neutron pulse shape from both a {sup 252}Cf spontaneous fission source and a (d,d) neutron generator. An expression for light output over time was then developed by treating the decay of helium excited states in the same manner as the decay of radioactive isotopes. This pulse shape expression was fitted to the measured neutron pulse shape using a least-squares optimization algorithm, allowing an empirical analysis of the mechanism of scintillation inside the {sup 4}He detector. A further understanding of this mechanism in the {sup 4}He detector will advance the use of this system as a neutron spectrometer. For {sup 252}Cf neutrons, the triplet and singlet time constants were found to be 970 ns and 686 ns, respectively. For neutrons from the (d,d) generator, the time constants were found to be 884 ns and 636 ns. Differences were noted in the magnitude of these parameters compared to previously published data, however the general relationships were noted to be the same and checked with expected trends from theory. Of the excited helium states produced from a {sup 252}Cf neutron interaction, 76% were found to be born as triplet states, similar to the result from the neutron generator of 71%. The two sources yielded similar pulse shapes despite having very different neutron energy spectra, validating the robustness of the fits across various neutron energies.

36 MATERIALS SCIENCE↗

Deuteron Acceleration and Fusion Neutron Production in Z-pinch plasmas

Fusion neutron measurements were carried out on the S-300 generator (Kurchatov Institute, Moscow). We tried deuterated fibers, various types of wire arrays imploding onto a deuterated fiber, and deuterium gas puffs as Z-pinch loads. On the current level of 2 MA, the peak neutron yield of 10{sup 10} was achieved with a deuterium gas-puff. The neutron and deuteron energy spectra were quite similar in various types of Z-pinch configurations. The broad width of radial neutron spectra implied a high radial component of deuteron velocity. On the basis of neutron measurements, we concluded that neutron production mechanism is connected with the study of plasma voltage. It means that the acceleration of fast deuterons is not a secondary process but it reflects the global dynamics of Z-pinch plasmas. For this reason it is useful to add deuterium as a 'tracer' in Z-pinch loads more often. For instance, it seems attractive to prepare wire-arrays from deuterated metal wires such as Pd.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Delayed Neutron Precursor Group Parameter and Spectra Generation from Fast Fission of 235U in SCALE

Delayed neutron precursor (DNP) group data are important for modeling reactor dynamics. Although the data for individual DNPs have been developed over time, the DNP group data present in the Evaluated Nuclear Data Files (ENDF) have not been updated in the past 20 years. In this work, we use SCALE to recreate the Godiva experiment that was used to generate the original DNP group structure for fast fission of 235U. However, each DNP is modeled using up-to-date data, and the results are then converted into a newly updated group structure. This conversion uses an iterative linear least squares solver to minimize chi-squared. The approaches used in this work also enable energy spectrum generation and uncertainty tracking. The method used in this paper for fast 235U fission DNP group structure updating can be applied to different energies and fissile nuclides. Demonstration of the uncertainty tracking in reactor kinetics and dynamics simulations is shown using point reactor kinetics simulations. Results show that there are data discrepancies between the International Atomic Energy Agency database and data used in ORIGEN, which are currently being fixed. Results also show that the proposed method for group spectra generation performs well.

Seifert, Luke [University of Illinois]↗

Study of the filter method for neutron pulse-height distributions measured with organic scintillators

Identification of neutron sources is of interest in several fields, such as homeland security or basic nu-clear physics. Organic scintillators offer the possibility to unfold fast-neutron energy spectra. Since organic scintillators are sensitive to neutrons and gamma-rays, a method to discriminate these two types of particles is required. This paper is focused on investigation of the discrimination properties of the filter method by using a new procedure. We compare the results of an experimental filter method to a digital pulse-shape discrimination (PSD) method based on charge integration. In addition, these methods are compared to the simulation results obtained with the MCNPX-PoliMi code. The experimental and nu-merical investigations were performed with a 252Cf spontaneous-fission neutron source. The integration of the number of counts gave the relative differences between the experimental filter and digital PSD neutron pulse-height distributions (PHDs) and simulated PHDs less than approximately 5% in the range between 60 keVee and 1.715 MeVee of light output. Above 1.715 MeVee, the PSD method has advantages over the filter method, due to the filter method having significantly worse counting statistics. The results show that the filter method has potential for robust neutron measurements when the PSD method cannot be applied, such as for ‘old’ organic plastic scintillators without PSD capability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Historical Examination of the ASTM Standard E722 1-MeV Silicon Equivalent Fluence Metric

ASTM Committee E10 on Nuclear Technology and Applications develops and maintains many standards that are relevant to the radiation metrology activities in Sandia National Laboratories' Radiation and Electrical Sciences Center. This is particularly true for the reactor facilities and Subcommittee E10.07 on Radiation Dosimetry for Radiation Effects on Materials and Devices. In the past decade, Subcommittee E10.07 has been making substantive changes to the standard widely used to assess radiation hardness to neutron effects in electronics, E722 – Standard Practice for Characterking Neutron Fluence Spectra in Terms of an Equivalent Monoenergetic Neutron Fluence for Radiation-Hardness Testing of Electronics . ASTM Standard E722 describes the method that defines the 1-MeV silicon and the 1-MeV gallium arsenide equivalent fluence radiation damage metrics. An evaluation of the impact of changes to the shape of the 1-MeV silicon equivalent fluence radiation damage metric from the 1985 version (E722-85) to the most recent version (E722-19) is performed.

36 MATERIALS SCIENCE↗

Pulsed Sphere Time of Flight Neutron Spectrum Measurements: Blank Run and 1.8 Mean-Free-Path thick Polyethylene Moderating Sphere

From the late 1960s to 1985, Lawrence Livermore National Laboratory (LLNL) undertook a series of ‘pulsed sphere’ experiments for 32 materials involving 148 different experiments using 75 different spheres to measure the neutron leakage spectra for different materials from 14-MeV neutrons generated by 3 H(d, n) 4 He reactions induced by an incident D+ beam from the Insulated Core Transformer (ICT) accelerator at LLNL. This deuteron beam was focused to impinge on tritium loaded onto a titanium substrate within a low mass target assembly placed within the center of a spherical shell constructed from the material of interest. The neutron time of flight was measured at a detector outside a collimator. The program was intended to be comprehensive with numerous targets of various thicknesses spanning the periodic table from H to 239 Pu. Five different neutron detectors were utilized to avoid possible systematic errors due to differences in detector responses. Further, these measurements were designed with the aim that the simple geometry of the measurements could be easily simulated to validate Monte Carlo transport codes and nuclear data libraries. As a result, these benchmarks have been extensively used in the validation of ENDL, ENDF and other libraries. Two experiments selected as benchmark cases in this evaluation are: 1) target assembly without material sphere (blank run), and 2) target assembly with a hollow polyethylene sphere, 1.8 mean free path (mfp) or 16.56 cm thick.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coupling of the hydration water dynamics and the internal dynamics of actin detected by quasielastic neutron scattering

Highlights: ► Quasielastic neutron scattering spectra of F-actin and G-actin were measured. ► Analysis of the samples in D{sub 2}O and H{sub 2}O provided the spectra of hydration water. ► The first layer hydration water around F-actin is less mobile than around G-actin. ► This difference in hydration water is in concert with the internal dynamics of actin. ► Water outside the first layer behaves bulk-like but influenced by the first layer. -- Abstract: In order to characterize dynamics of water molecules around F-actin and G-actin, quasielastic neutron scattering experiments were performed on powder samples of F-actin and G-actin, hydrated either with D{sub 2}O or H{sub 2}O, at hydration ratios of 0.4 and 1.0. By combined analysis of the quasielastic neutron scattering spectra, the parameter values characterizing the dynamics of the water molecules in the first hydration layer and those of the water molecules outside of the first layer were obtained. The translational diffusion coefficients (D{sub T}) of the hydration water in the first layer were found to be 1.2 × 10{sup −5} cm{sup 2}/s and 1.7 × 10{sup −5} cm{sup 2}/s for F-actin and G-actin, respectively, while that for bulk water was 2.8 × 10{sup −5} cm{sup 2}/s. The residence times were 6.6 ps and 5.0 ps for F-actin and G-actin, respectively, while that for bulk water was 0.62 ps. These differences between F-actin and G-actin, indicating that the hydration water around G-actin is more mobile than that around F-actin, are in concert with the results of the internal dynamics of F-actin and G-actin, showing that G-actin fluctuates more rapidly than F-actin. This implies that the dynamics of the hydration water is coupled to the internal dynamics of the actin molecules. The D{sub T} values of the water molecules outside of the first hydration layer were found to be similar to that of bulk water though the residence times are strongly affected by the first hydration layer. This supports the recent observation on intracellular water that shows bulk-like behavior.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Criticality Safety Validation of Scale 6.1

The computational bias of criticality safety computer codes must be established through the validation of the codes to critical experiments. A large collection of suitable experiments has been vetted by the International Criticality Safety Benchmark Experiment Program (ICSBEP) and made available in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (IHECSBE). A total of more than 350 cases from this reference have been prepared and reviewed within the Verified, Archived Library of Inputs and Data (VALID) maintained by the Reactor and Nuclear Systems Division at Oak Ridge National Laboratory. The performance of the KENO V.a and KENO-VI Monte Carlo codes within the Scale 6.1 code system with ENDF/B-VII.0 cross-section data in 238-group and continuous energy is assessed using the VALID models of benchmark experiments. The TSUNAMI tools for sensitivity and uncertainty analysis are utilized to examine some systems further in an attempt to identify potential causes of unexpected results. The critical experiments available for validation of the KENO V.a code cover eight different broad categories of systems. These systems use a range of fissile materials including a range of uranium enrichments, various plutonium isotopic vectors, and mixed uranium-plutonium oxides. The physical form of the fissile material also varies and is represented as metal, solutions, or arrays of rods or plates in a water moderator. The neutron energy spectra of the systems also vary and cover both fast and thermal spectra. Over 300 of the total cases used utilize the KENO V.a code. The critical experiments available for the validation of the KENO-VI code cover three broad categories of systems. The fissile materials in the systems vary and include high and intermediate-enrichment uranium and mixed uranium/plutonium oxides. The physical form of the fissile material is either metal or rod arrays in water. As with KENO V.a, both fast and thermal neutron energy spectra are represented in the systems considered. The results indicate generally good performance of both the KENO V.a and KENO-VI codes across the range of systems analyzed. The bias of calculated k{sub eff} from expected values is less than 0.9% {Delta}k in all cases. All eight categories of experiments show biases of less than 0.5% {Delta}k in KENO V.a with the exception of intermediate enrichment metal systems using the 238-group library. The continuous energy library generally manifests lower biases than the multi-group data. The KENO-VI results show slightly larger biases, though this may primarily be the result of modeling systems with more geometric complexity, which are more difficult to describe accurately, even with a generalized geometry code like KENO-VI. Several additional conclusions can be drawn from the results of this validation effort. These conclusions include that the TSUNAMI tools can be used successfully to explain the cause of aberrant results, that some evaluations in the IHECSBE should be updated to provide more rigorous expected k{sub eff} values and uncertainties, and that potential cross-section errors can be identified by detailed review of the results of this validation. It also appears that the overall cross-section uncertainty as quantified through the Scale covariance library is overestimated. Overall, the KENO V.a and KENO-VI codes are shown to provide consistent, low bias results for a wide range of physical systems of potential interest in criticality safety applications.

Marshall, William BJ J↗

Criticality Safety Validation of SCALE 6.1 (Revised)

The computational bias of criticality safety computer codes must be established through the validation of the codes to critical experiments. A large collection of suitable experiments has been vetted by the International Criticality Safety Benchmark Experiment Program (ICSBEP) and made available in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (IHECSBE). A total of more than 350 cases from this reference have been prepared and reviewed within the Verified, Archived Library of Inputs and Data (VALID) maintained by the Reactor and Nuclear Systems Division at Oak Ridge National Laboratory. The performance of the KENO V.a and KENO-VI Monte Carlo codes within the SCALE 6.1 code system with ENDF/B-VII.0 cross-section data in 238-group and continuous energy is assessed using the VALID models of benchmark experiments. The TSUNAMI tools for sensitivity and uncertainty analysis are utilized to examine some systems further in an attempt to identify potential causes of unexpected results. The critical experiments available for validation of the KENO V.a code cover eight different broad categories of systems. These systems use a range of fissile materials including a range of uranium enrichments, various plutonium isotopic vectors, and mixed uranium/plutonium oxides. The physical form of the fissile material also varies and is represented as metal, solutions, or arrays of rods or plates in a water moderator. The neutron energy spectra of the systems also vary and cover both fast and thermal spectra. Over 300 of the total cases used utilize the KENO V.a code. The critical experiments available for the validation of the KENO-VI code cover three broad categories of systems. The fissile materials in the systems vary and include high- and intermediate-enrichment uranium and mixed uranium/plutonium oxides. The physical form of the fissile material is either metal or rod arrays in water. As with KENO V.a, both fast and thermal neutron energy spectra are represented in the systems considered. The results indicate generally good performance of both the KENO V.a and KENO-VI codes across the range of systems analyzed. The bias of calculated k eff from expected values is less than 0.9% Δk in all cases. All eight categories of experiments show biases of less than 0.5% Δk in KENO V.a with the exception of intermediate enrichment metal systems using the 238-group library. The continuous energy library generally manifests lower biases than the multigroup data. The KENO-VI results show slightly larger biases, though this may primarily be the result of modeling systems with more geometric complexity, which are more difficult to describe accurately, even with a generalized geometry code like KENO-VI. Several additional conclusions can be drawn from the results of this validation effort. These conclusions include that the TSUNAMI tools can be used successfully to explain the cause of aberrant results, that some evaluations in the IHECSBE should be updated to provide more rigorous expected k eff values and uncertainties, and that potential cross-section errors can be identified by detailed review of the results of this validation. It also appears that the overall cross-section uncertainty as quantified through the SCALE covariance library is overestimated. Overall, the KENO V.a and KENO-VI codes are shown to provide consistent, low-bias results for a wide range of physical systems of potential interest in criticality safety applications.

Marshall, William (BJ) J.↗

Structure-dependent vibrational dynamics of Mg(BH 4 ) 2 polymorphs probed with neutron vibrational spectroscopy and first-principles calculations

We investigated the structure-dependent vibrational properties of different Mg(BH 4 ) 2 polymorphs (α, β, γ, and δ phases) with a combination of neutron vibrational spectroscopy (NVS) measurements and density functional theory (DFT) calculations, with emphasis placed on the effects of the local structure and orientation of the BH 4 - anions. DFT simulations closely match the neutron vibrational spectra. The main bands in the low-energy region (20–80 meV) are associated with the BH4 - librational modes. The features in the intermediate energy region (80–120 meV) are attributed to overtones and combination bands arising from the lower-energy modes. The features in the high-energy region (120–200 meV) correspond to the BH 4 - symmetric and asymmetric bending vibrations, of which four peaks located at 140, 142, 160, and 172 meV are especially intense. There are noticeable intensity distribution variations in the vibrational bands for different polymorphs. We can explain these differences using the spatial distribution of BH 4 - anions within various structures. An example of the possible identification of products after the hydrogenation of MgB 2 , using NVS measurements, is presented. Our results provide fundamental insights of benefit to researchers currently studying these promising hydrogen-storage materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamics of water confined on the surface of titania and cassiterite nanoparticles

We present low-temperature inelastic neutron scattering spectra collected on two metal oxide nanoparticle systems, isostructural TiO2 rutile and SnO2 cassiterite, between 0-550 meV. Data were collected on samples with varying levels of water coverage, and in the case of SnO2, particles of different sizes. This study provides a comprehensive understanding of the structure and dynamics of the water confined on the surface of these particles. The translational movement of water confined on the surface of these nanoparticles is suppressed relative to that in ice-Ih and water molecules on the surface of rutile nanoparticles are more strongly restrained that molecules residing on the surface of cassiterite nanoparticles. The INS spectra also indicate that the hydrogen bond network within the hydration layers on rutile is more perturbed than for water on cassiterite. This result is indicative of stronger water-surface interactions between water on the rutile nanoparticles than for water confined on the surface of cassiterite nanoparticles. These differences are consistent with the recently reported differences in the surface energy of these two nanoparticle systems. The results of this study also support previous studies that suggest that water dissociation is more prevalent on the surface of SnO2 than TiO2.

08 HYDROGEN↗

( d , n ) proton-transfer reactions on Be 9 , B 11 , C 13 , N 14 , 15 , and F 19 and spectroscopic factors at E d = 16 MeV

The (d,n) reaction has been studied with targets of 9 Be, 11 B, 13 C, 14,15 N, and 19F at E d = 16MeV using a deuterated liquid-scintillator array. Advanced spectral unfolding techniques with accurately measured scintillator response functions were employed to extract neutron energy spectra without the need for long-path neutron time-of-flight. An analysis of the proton-transfer data at forward angles to the ground states of the final nuclei, using finite-range distorted-wave Born approximation analysis with common bound-state, global, and local optical-model parameter sets, yields a set of self-consistent spectroscopic factors. These are compared with the results of several previous time-of-flight measurements, most done many years ago for individual nuclei at lower energy and often analyzed using zero-range transfer codes. In contrast to some of the earlier published data, our data generally compare well with simple shell-model predictions, with little evidence for uniform quenching (reduction from shell-model values) that has previously been reported from analysis of nucleon knock-out reactions. Data for low-lying excited states in 14 N from 13 C(d,n) also is analyzed and spectroscopic information relevant to nuclear astrophysics obtained. Here, a preliminary study of the radioactive ion beam induced reaction 7 Be(d,n), E( 7 Be) = 30MeV was carried out and indicates further improvements are needed for such measurements, which require detection of neutrons with E n < 2MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗