A D$_2$O detector for flux normalization of a pion decay-at-rest neutrino source

We report on the technical design and expected performance of a 592 kg heavy-water-Cherenkov detector to measure the absolute neutrino flux from the pion-decay-at-rest neutrino source at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The detector will be located roughly 20 m from the SNS target and will measure the neutrino flux with better than 5% statistical uncertainty in 2 years. This heavy-water detector will serve as the first module of a two-module detector system to ultimately measure the neutrino flux to 2–3% at both the First Target Station and the planned Second Target Station of the SNS. This detector will significantly reduce a dominant systematic uncertainty for neutrino cross-section measurements at the SNS, increasing the sensitivity of searches for new physics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent elastic neutrino-nucleus scattering at the European Spallation Source

The European Spallation Source (ESS), presently well on its way to completion, will soon provide the most intense neutron beams for multi-disciplinary science. Fortuitously, it will also generate the largest pulsed neutrino flux suitable for the detection of Coherent Elastic Neutrino-Nucleus Scattering (CEνNS), a process recently measured for the first time at ORNL’s Spallation Neutron Source. We describe innovative detector technologies maximally able to profit from the order-of-magnitude increase in neutrino flux provided by the ESS, along with their sensitivity to a rich particle physics phenomenology accessible through high-statistics, precision CEνNS measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Scientific Justification for a U.S. Domestic High-Performance Reactor-Based Research Facility

The Basic Energy Science Advisory Committee (BESAC) was charged with forming a subcommittee to assess the scientific justification for a U.S. domestic high-performance reactor-based research facility in order to continue providing the U.S scientific community with leading neutron capabilities in support of DOE's missions in science, energy, environment, and national security. The assessment included consideration of current international plans and existing domestic facility infrastructure. The subcommittee held a series of meetings from August 19, 2019 to April 24, 2020 that included DOE senior officials, leaders of national and international neutron facilities (SNS, HFIR, NIST, ILL, FRM-II), chairs of the NAS and POPA HEU-LEU committees, and outside experts on important areas of science, technology, and industry where high flux nuclear reactor facilities make important contributions. Also included were tours of neutron facilities (SNS, HFIR, NIST, BR2 reactor, and the planned Jules Horowitz Reactor). This July 2020 (revised 10-28-2020) report describes scientific use cases, brief summaries of existing and planned neutron facilities in the US and Europe, a comprehensive review of HFIR, a comprehensive discussion of the current state of progress on HEU-LEU conversion, user information from NIST and ORNL, and three recommendations to DOE for moving forward.

36 MATERIALS SCIENCE↗

Monitoring the SNS basement neutron background with the MARS detector

Here, we present the analysis and results of the first dataset collected with the MARS neutron detector deployed at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) for the purpose of monitoring and characterizing the beam-related neutron (BRN) background for the COHERENT collaboration. MARS was positioned next to the COH-CsI coherent elastic neutrino-nucleus scattering detector in the SNS basement corridor. This is the basement location of closest proximity to the SNS target and thus, of highest neutrino flux, but it is also well shielded from the BRN flux by infill concrete and gravel. Furthermore, these data show the detector registered roughly one BRN per day. Using MARS' measured detection efficiency, the incoming BRN flux is estimated to be 1.20 ± 0.56 neutrons/m 2 /MWh for neutron energies above ~3.5 MeV and up to a few tens of MeV. We compare our results with previous BRN measurements in the SNS basement corridor reported by other neutron detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Flux effects in precipitation under irradiation simulation of Fe-Cr alloys

Radiation-enhanced precipitation of Cr-rich α’ in irradiated Fe-Cr alloys, which results in hardening and embrittlement, depends on the irradiating particle and the displacement per atom (dpa) rate. Here, we utilize a Cahn-Hilliard phase-field based approach, that includes simple models for nucleation, irradiating particle and rate dependent radiation-enhanced diffusion and cascade mixing to simulate α’ evolution under neutrons, heavy ions, and electron irradiations. Different irradiating particles manifest very different cascade mixing efficiencies. The model was calibrated using neutron data. For cascade inducing neutron/heavy-ion dpa rates at 300 °C between 10-8 and 10-6 dpa/s the model predicts approximately constant number density, decreasing radius, decreasing α’ Cr composition, and lower α’ volume fraction. The model then predicts a dramatic transition to no α’ formation above approximately 10-5 dpa/s, while electron irradiation, with weak mixing, had little effect at dpa rates up to 10-3 dpa/s. These model predictions are consistent with experiments. We explain the results in terms of the flux dependence of the radiation enhanced diffusion, cascade mixing, and their ratio, which all vary significantly in relevant flux ranges for neutron and cascade inducing ion irradiations. These results show that both cascade mixing and radiation enhanced diffusion must be accounted for when attempting to emulate neutron-irradiation effects using accelerated ion irradiations.

Ke, Jia-Hong↗

A fusion relevant data-driven engineering void swelling model for 9Cr tempered martensitic steels

The UCSB database on cavity evolution in 9-12Cr tempered martensitic steels (TMS), includes the results for both dual heavy and helium ion (DII), and High Flux Isotope Reactor (HFIR) in situ helium injection (ISHI) neutron irradiations at 500°C. These results were combined with literature single ion and fission neutron irradiation data to derive a model for the void volume fraction, f v , as a function of displacements per atom (dpa) and transmutant helium concentrations in atomic parts per million (appm). The scientific foundation for the paper is described in a companion paper entitled “Cavity Evolution and Void Swelling in Dual Ion Irradiated Tempered Martensitic Steels”. Here, in this study, we show that f v (dpa, He/dpa) is described by the incubation dose, dpa i , for the onset of void growth, and the post-incubation growth rate, f v ’(%/dpa). Both dpa i and f v ’ decrease with increasing He/dpa at > ~ 5. The dpa i is also lower for the ISHI neutron irradiations at the same He/dpa. Single heavy ion and fission reactor neutron irradiations, with low He/dpa ratios, have a much larger dpa i . Based on a combined analysis of DII, single ion, ISHI and fission neutron data, we further show that the post-incubation f v data analyzed here have a common empirical curve shape, with f v ’ reaching up to ~ 0.2%/dpa at very high dpa. We also show that f v ’ can be predicted based on a physical model of defect partitioning between evolving sinks. At 500°C and fusion relevant He/dpa ≈ 10, the best-fit model predicts nominal swelling, S = f v /(1-f v ), of ~ 1.1, 4.9 and 16% at 50, 100 and 200 dpa, respectively. The physically motivated, data-driven model includes estimated uncertainties for both dpa i and f v ’.

36 MATERIALS SCIENCE↗

Improvements to the 115g/115m Cd Nuclear Data

Repeated measurements of the isotope 115m Cd by Los Alamos National Laboratory (LANL), Pacific Northwest National Laboratory (PNNL), and Atomic Weapons Establishment (AWE) have revealed a consistent discrepancy between beta and gamma counting. This suggests that a significant disparity exists between the true value of the isotope’s gamma-ray branching ratios and the values reported by the National Nuclear Data Center (NNDC). Enriched 114 Cd was irradiated using thermal neutrons to produce a high-purity 115m/g Cd source for counting and analysis using traditional singles gamma-ray spectroscopy, liquid scintillation counting, gas-proportional counting, and analysis using the new Gamma-Alpha-Beta-Gamma (GABγ) and Gamma-Alpha-Beta Radio-Isotope EvaLuator (GABRIEL) coincidence detection systems. Using the D-T fusion generated neutrons, reduces the wait time required to let the short-lived 115Cd ground state decay away by leveraging the 1:1 production ratio of the ground and metastable state of 115 Cd from the 115 In (n,p) reaction relative to the 10:1 production ratio of the ground and metastable isotopes of 115 Cd by thermal neutron capture on 114 Cd. However, the much higher flux in from the Washington State University TRIGA reactor is a more rapid method of production of 115m/gCd but requires access to enriched 114 Cd. High purity 115m/g Cd samples were analyzed on regular intervals over a period of 140-days. The activity of 115m Cd measured by beta and gamma show a clear discrepancy using the current best known gamma-ray decay branching ratios. Based on these observations and measurements, a set of new branching ratio recommendations have been produced using conventional counting techniques and the advanced GAB? and GABRIEL instruments.

07 ISOTOPE AND RADIATION SOURCES↗

Benchmarking of Different Inverse Point Kinetics Implementations for an Autocorrected Reactimeter Algorithm

In November 2017, the Transient Reactor Test Facility returned to operation. Since that time, many transient test series have been completed; each has provided valuable data for materials performance, reactor safety that can be applied in future designs. During each experimental series, detector count rates provided important information on the core behavior during transients. However, a limitation of these data is that variations in the neutron distribution during experiments cause errors when attempting to infer reactivity evolution from detector signals. Neutron physics codes can be used to compute the flux shape variations. However, this is a poor solution when the experimental data is used to do verification, validation and uncertainty quantification (VVUQ) on codes. Indeed, if the output of the code is used both as a reference and to correct what the reference is compared to, the circular dependency limits the quality of the VVUQ approach. To overcome this problem, an Autocorrected Reactimeter Algorithm (ACRA) has been developed. This approach infers time-dependent reactivity evolution by testing different spatial corrections and selecting the one that minimizes reactivity variations when the core is in a frozen configuration (i.e. when there is no variation in parameters affecting reactivity). However, the scope of this method was limited to transients where there were negligible thermal feedback. Indeed, the core is never in a frozen configuration when the fuel temperature varies during the whole transient. This is our motivation for the development of an improved version of the ACRA which does not require frozen configurations

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

(Doublon) Benchmarking of Different Inverse Point Kinetics Implementations for an Autocorrected Reactimeter Algorithm

In November 2017, the Transient Reactor Test Facility returned to operation. Since that time, many transient test series have been completed, such as the Transient Heatsink Overpower Response capsule (THOR), the Transient Water Irradiation System for TREAT (TWIST), and Sirius. Each has provided valuable data for materials performance and reactor safety that can be applied in future designs. During each experimental series, detector count rates provided important information on the core behavior during transients. However, a limitation of these data is that variations in the neutron distribution during experiments can cause errors when attempting to infer reactivity evolution from detector signals. Neutron physics codes can be used to compute the flux shape variations. However, this is a poor solution when the experimental data is used for code verification, validation and uncertainty quantification. Indeed, if the output of the code is used both as a reference and to correct what the reference is compared to, the circular dependency limits the quality of the verification, validation and uncertainty quantification approach. To overcome this problem, the autocorrected reactimeter algorithm (ACRA) has been developed. This approach infers a time-dependent reactivity evolution by testing different spatial corrections and selecting the one that minimizes reactivity variations when the core is in a frozen configuration (i.e., when there is no variation in parameters affecting reactivity). However, the scope of this method was limited to transients where there were negligible thermal feedback. Indeed, the core is never in a frozen configuration when the fuel temperature varies during the whole transient. This is our motivation for developing an improved version of the ACRA that does not require frozen configurations. To develop this new algorithm, we need a precise and unbiased implementation of the inverse point kinetic equations (IPKEs) as any error in the reactivity evaluation will be propagated into the choice of the optimal spatial correction. Indeed, the previous reactimeter algorithm would use approximations, such as a negligible flux amplitude derivative, to focus on rapidity. For the numerical validation of ACRA, we aim at absolute error under for reactivity derived from signals similar to the one of this study. In this summary, we test eight different IPKE implementations. Each will process a mockup signal built for this study, similar to those that the future ACRA will process. Each reactivity output will be compared to the reference reactivity that has been used to generate the mockup signal. The implementation minimizing the difference with the reference reactivity will be used in the development of a new ACRA formulation.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron Dosimetry for the SAM-2 Irradiation in ATR

PNNL project 79550 provides for the analysis of neutron fluence monitors irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory in accordance with MPO 00269673 and Statement of Work No. 19704, Rev. 0, PNNL Analysis of NSUF Flux Capsules. This report is for the SAM-2 irradiation which was conducted in position B8 of the ATR. Other experiments included in the statement of work for this project will be reported separately. The neutron fluence monitors were prepared by PNNL and sent to INL for loading into the SAM-2 assembly prior to irradiation. The SAM-2 experiment has 8 capsules labelled A through H designed for different exposures in successive irradiation cycles. This report is for the first three capsules, A, B and C, co-irradiated for 1 cycle. The remaining capsules and fluence monitors will be removed and analyzed after additional irradiation. Following irradiation, the fluence monitors from capsules A, B, and C were returned to PNNL for analysis. The neutron dosimetry capsules were opened, the flux wires were removed for gamma or x-ray analysis, and the measured activities were used to determine the activation rates for various activation products. Following suitable corrections, the measured activation rates were used to adjust calculated neutron spectra at each fluence monitor location. The adjusted neutron spectra were then used to determine displacement per atom (dpa) and gas production for irradiated materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of a portable high-T c spherical neutron polarimetry device at the Oak Ridge National Laboratory

Spherical neutron polarimetry is a powerful polarized neutron scattering technique used to determine complex magnetic structures which are only partly accessible by other methods. This technique measures the full neutron polarization change upon scattering from a sample by fully decoupling the incoming and outgoing neutron polarization with a zero-field chamber placed at the sample position. Recent advancements and testing are presented for a new spherical neutron polarimetry device utilizing high-T c superconducting YBCO films, PHiTPAD, at the High Flux Isotope Reactor at Oak Ridge National Laboratory. Furthermore, we introduce a conceptual design that utilizes wavelength-independent adiabatic transitions to adapt spherical neutron polarimetry for use with pulsed neutron sources, thereby expanding its potential applications in neutron scattering research.

47 OTHER INSTRUMENTATION↗

Simulating and benchmarking neutron total scattering instrumentation from inception of events to reduced and fitted data

In the design and realization of modern neutron scattering instrumentation, particularly when designing beamline concepts from the ground up, it is desirable to fully benchmark against realistically simulated data. This is especially true for total scattering beamlines, where the future deliverable data is to be analysed in both reciprocal- and real-space representations, and needs must be carefully balanced to ensure sufficient range, resolution and flux of the instrument. An approach to optimize the design of neutron scattering instrumentation via a workflow including ray-tracing simulations, event-based data reduction, heuristic analysis and fitting against realistically simulated spectra is demonstrated here. The case of the DISCOVER beamline concept at the Spallation Neutron Source is used as an example. The results of the calculations are benchmarked through simulation of existing instrumentation and subsequent direct comparison with measured data. Finally, on the basis of the validated models, the ability to explore design characteristics for future beamline concepts or future instrument improvements is demonstrated through the examples of detector tube size and detector layout.

47 OTHER INSTRUMENTATION↗

Neutron Dosimetry for the Colorado School of Mines (CSM 16-10584) Irradiation in ATR

PNNL project 74242 involves the analysis of neutron fluence monitors irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory in accordance with MPO 00236287 and Statement of Work No. 17370, Rev. 0, PNNL Analysis of NSUF Flux and Melt Wire Capsules. This report is for the Colorado School of Mines (CSM 16-10584) experiment which was conducted in position B5 of the ATR. Three other irradiations included in the scope of work are reported separately. The neutron fluence monitors were prepared by PNNL and loaded into the CSM assemblies at INL prior to irradiation. Following irradiation, the capsules were returned to PNNL for analysis. The neutron dosimetry capsules were opened, the flux wires were removed for gamma analysis, and the measured activities were used to determine the activation rates for various activation products. Following suitable corrections, the measured activation rates were used to adjust calculated neutron spectra at 12 fluence monitor locations. The adjusted neutron spectra were then used to determine displacement per atom (dpa) and gas production for irradiated materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Dosimetry for the University of Central Florida (UCF3) Irradiation in ATR

PNNL project 74242 involves the analysis of neutron fluence monitors irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory in accordance with MPO 00236287 and Statement of Work No. 17370, Rev. 0, PNNL Analysis of NSUF Flux and Melt Wire Capsules. This report is for the University of Central Florida (UCF)-3 third stage experiment which was conducted in position B8 of the ATR. Three other irradiations included in the scope of work are reported separately. The neutron fluence monitors were prepared by PNNL and loaded into the UCF-3 assemblies at INL prior to irradiation. Following irradiation, the capsules were returned to PNNL for analysis. The neutron dosimetry capsules were opened, the flux wires were removed for gamma analysis, and the measured activities were used to determine the activation rates for various activation products. Following suitable corrections, the measured activation rates were used to adjust calculated neutron spectra at 8 fluence monitor locations. The adjusted neutron spectra were then used to determine displacement per atom (dpa) and gas production for irradiated materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Dosimetry for the GE Hitachi 16-10393 Irradiation in ATR

PNNL project 74242 involves the analysis of neutron fluence monitors and melt wires irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory in accordance with MPO 00236287 and Statement of Work (SOW) No. 17370, Rev. 0, PNNL Analysis of NSUF Flux and Melt Wire Capsules. This report is for the GE Hitachi 16-10393 irradiation which was conducted in positions B11 of the ATR. Three other irradiations included in the SOW will be reported separately. The neutron fluence monitors were prepared by PNNL and loaded into the GE Hitachi assemblies prior to irradiation. Following irradiation, the capsules were returned to PNNL for analysis. The neutron dosimetry capsules were opened, the flux wires were removed for gamma analysis. The measured activities were used to determine the activation rates for various activation products. Following suitable corrections, the measured activation rates were used to adjust calculated neutron spectra at each fluence monitor location. The adjusted neutron spectra were then used to determine displacement per atom (dpa) and gas production for irradiated materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Josephson currents in neutron stars

We demonstrate that the interface between S-wave and P-wave paired superfluids in neutron stars induces a neutron supercurrent, a charge-neutral analog of the Josephson junction effect in electronic superconductors. The proton supercurrent entrainment by the neutron superfluid generates, in addition to the neutral supercurrent, a charged current across the interface. Beyond this stationary effect, the motion of the neutron vortex lines responding to secular changes in the neutron star’s rotation rate induces a time-dependent oscillating Josephson current across this interface when proton flux tubes are dragged along with them. We show that such motion produces radiation from the interface once clusters of proton flux tubes intersect the interface. The power of radiation exceeds by orders of magnitude the Ohmic dissipation of currents in neutron stars. As a result, this effect appears to be phenomenologically significant enough to heat the star and alter its cooling rate during the photon cooling era.

79 ASTRONOMY AND ASTROPHYSICS↗

Measured Thermal and Fast Neutrons Fluence Rates for ATF-1 Holders During ATR Cycle 166B

This report contains the thermal (2200 m/s) and fast (E>lMeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 166B which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains measurements of the fluence rates corresponding to the particular elevations relative to the 80-ft. core elevation. The data in this report consist of (1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, and (3) plots of both the thermal and fast neutron fluence rates. All "BR" holder monitor wires for this cycle are 56.375 inches long. This length allows measurements from 31.17 inches above core midplane to 19.81 inches below core midplane. The distance from the end of the wires to the first count position was 4.25 inches for all wires counted from this cycle. The monitors were located in an outward small I-holes,1-22 and 1-23. Thermal neutron fluence was determined based on the activation of the CoAl wires and resonance corrections determined in the irradiation of Cycle 152A when the RML measured cadmium-covered as well as bare neutron monitors in the Southwest, Southeast, and H positions at the Center lobe to determine the division in neutron energy between epithermal and thermal neutrons. For more information please refer to letter “Radiation Measurements Laboratory measurements of in core ATR physics testing during cycle 152A. The measured values documented in RML procedure, “ACMM-3600, Flux Monitoring,” will be used indefinitely until further measurements supersede the current values. Fast neutron fluence was determined using the activation of nickel wires. Typically, a fission spectrum averaged cross section (E>1 MeV) is used as determined in detailed measurements described in “ATR Neutron Spectral Characterization,” which gives an effective cross section of 97 mb for the small I-holes. However, those measurements were performed with unfueled experiments. The fast fluence values reported here use a perturbed 114 mb effective>1 MeV spectrum averaged cross section for the small I-holes based on MCNP simulations for a previous fueled experiment in the1-24 position. Refer to “LWR- ATR Irradiation Measured Thermal and Fast Neutron Fluence Rates ATR CYCLE 133A 04/19/04 thru 05/17/04” for more information.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Calibration sources for the LEGEND-200 experiment

In the search for a monochromatic peak as the signature of neutrinoless double beta decay an excellent energy resolution and an ultra-low background around the Q-value of the decay are essential. The LEGEND-200 experiment performs such a search with high-purity germanium detectors enriched in 76 Ge immersed in liquid argon. To determine and monitor the stability of the energy scale and resolution of the germanium diodes, custom-made, low-neutron emission 228 Th sources are regularly deployed in the vicinity of the crystals. Here we describe the production process of the 17 sources available for installation in the experiment, the measurements of their alpha- and gamma- activities, as well as the determination of the neutron emission rates with a low-background LiI(Eu) detector operated deep underground. With a flux of ( 4.27 ± 0.60 stat ± 0.92 syst ) × 10 -4 n / (kBq·s), approximately one order of magnitude below that of commercial sources, the neutron-induced background rate, mainly from the activation of 76 Ge, is negligible compared to other background sources in LEGEND-200.