Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Monte Carlo Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

SU-E-T-565: RAdiation Resistance of Cancer CElls Using GEANT4 DNA: RACE

Purpose: The objective of the RACE project is to develop a comparison between Monte Carlo simulation using the Geant4-DNA toolkit and measurements of radiation damage on 3D melanoma and chondrosarcoma culture cells coupled with gadolinium nanoparticles. We currently expose the status of the developments regarding simulations. Methods: Monte Carlo studies are driven using the Geant4 toolkit and the Geant4-DNA extension. In order to model the geometry of a cell population, the opensource CPOP++ program is being developed for the geometrical representation of 3D cell populations including a specific cell mesh coupled with a multi-agent system. Each cell includes cytoplasm and nucleus. The correct modeling of the cell population has been validated with confocal microscopy images of spheroids. The Geant4 Livermore physics models are used to simulate the interactions of a 250 keV X-ray beam and the production of secondaries from gadolinium nanoparticles supposed to be fixed on the cell membranes. Geant4-DNA processes are used to simulate the interactions of charged particles with the cells. An atomistic description of the DNA molecule, from PDB (Protein Data Bank) files, is provided by the so-called PDB4DNA Geant4 user application we developed to score energy depositions in DNA base pairs and sugar-phosphate groups. Results: At the microscopic level, our simulations enable assessing microscopic energy distribution in each cell compartment of a realistic 3D cell population. Dose enhancement factors due to the presence of gadolinium nanoparticles can be estimated. At the nanometer scale, direct damages on nuclear DNA are also estimated. Conclusion: We successfully simulated the impact of direct radiations on a realistic 3D cell population model compatible with microdosimetry calculations using the Geant4-DNA toolkit. Upcoming validation and the future integration of the radiochemistry module of Geant4-DNA will propose to correlate clusters of ionizations with in vitro experiments. All those developments will be released publicly. This work was supported by grants from Plan Cancer 2009-2013 French national initiative managed by INSERM (Institut National de la Sante et de la Recherche Medicale)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of individual organ doses in a realistic human phantom from neutron and gamma stimulated spectroscopy of the breast and liver

Purpose: Understanding the radiation dose to a patient is essential when considering the use of an ionizing diagnostic imaging test for clinical diagnosis and screening. Using Monte Carlo simulations, the authors estimated the three-dimensional organ-dose distribution from neutron and gamma irradiation of the male liver, female liver, and female breasts for neutron- and gamma-stimulated spectroscopic imaging. Methods: Monte Carlo simulations were developed using the Geant4 GATE application and a voxelized XCAT human phantom. A male and a female whole body XCAT phantom was voxelized into 256 × 256 × 600 voxels (3.125 × 3.125 × 3.125 mm{sup 3}). A monoenergetic rectangular beam of 5.0 MeV neutrons or 7.0 MeV photons was made incident on a 2 cm thick slice of the phantom. The beam was rotated at eight different angles around the phantom ranging from 0° to 180°. Absorbed dose was calculated for each individual organ in the body and dose volume histograms were computed to analyze the absolute and relative doses in each organ. Results: The neutron irradiations of the liver showed the highest organ dose absorption in the liver, with appreciably lower doses in other proximal organs. The dose distribution within the irradiated slice exhibited substantial attenuation with increasing depth along the beam path, attenuating to ∼15% of the maximum value at the beam exit side. The gamma irradiation of the liver imparted the highest organ dose to the stomach wall. The dose distribution from the gammas showed a region of dose buildup at the beam entrance, followed by a relatively uniform dose distribution to all of the deep tissue structures, attenuating to ∼75% of the maximum value at the beam exit side. For the breast scans, both the neutron and gamma irradiation registered maximum organ doses in the breasts, with all other organs receiving less than 1% of the breast dose. Effective doses ranged from 0.22 to 0.37 mSv for the neutron scans and 41 to 66 mSv for the gamma scans. Conclusions: Neutron and gamma irradiation of a primary target organ was found to impart the majority of the total dose to the primary target organ (and other large organs) within the beam plane and considerably lower dose to proximal organs outside of the beam. These results also indicate that despite the use of a highly scattering particle such as a neutron, the dose from neutron stimulated emission computed tomography scans is on par with other clinical imaging techniques such as x-ray computed tomography (x-ray CT). Given the high nonuniformity in the dose across an organ during the neutron scan, care must be taken when computing average doses from neutron irradiations. The effective doses from neutron scanning were found to be comparable to x-ray CT. Further technique modifications are needed to reduce the effective dose levels from the gamma scans.

61 RADIATION PROTECTION AND DOSIMETRY↗

Space Radiation Transport Methods Development

Improved spacecraft shield design requires early entry of radiation constraints into the design process to maximize performance and minimize costs. As a result, we have been investigating high-speed computational procedures to allow shield analysis from the preliminary design concepts to the final design. In particular, we will discuss the progress towards a full three-dimensional and computationally efficient deterministic code for which the current HZETRN evaluates the lowest order asymptotic term. HZETRN is the first deterministic solution to the Boltzmann equation allowing field mapping within the International Space Station (ISS) in tens of minutes using standard Finite Element Method (FEM) geometry common to engineering design practice enabling development of integrated multidisciplinary design optimization methods. A single ray trace in ISS FEM geometry requires 14 milliseconds and severely limits application of Monte Carlo methods to such engineering models. A potential means of improving the Monte Carlo efficiency in coupling to spacecraft geometry is given in terms of reconfigurable computing and could be utilized in the final design as verification of the deterministic method optimized design.

Wilson, J. W.↗

PROBING THE ISOTROPY OF COSMIC ACCELERATION TRACED BY TYPE Ia SUPERNOVAE

We present a method to test the isotropy of the magnitude–redshift relation of Type Ia Supernovae (SNe Ia) and single out the most discrepant direction (in terms of the signal-to-noise ratio) with respect to the all-sky data. Our technique accounts for possible directional variations of the corrections for SNe Ia and yields all-sky maps of the best-fit cosmological parameters with arbitrary angular resolution. To show its potential, we apply our method to the high-redshift SNe Ia from the recent Union2.1 compilation, building maps with three different angular resolutions. We use a Monte Carlo method to estimate the statistical significance with which we could reject the null hypothesis that the magnitude–redshift relation is isotropic based on the properties of the observed most discrepant directions. We find that, based on pure signal-to-noise arguments, the null hypothesis cannot be rejected at any meaningful confidence level. However, if we also consider that the strongest deviations in the Union2.1 sample closely align with the dipole temperature anisotropy of the cosmic microwave background, we find that the null hypothesis should be rejected at the 95%–99% confidence level, slightly depending on the angular resolution of the study. If this result is not due to a statistical fluke, it might either indicate that the SN data have not been cleaned from all possible systematics or even point toward new physics. We finally discuss future perspectives in the field for achieving larger and more uniform data sets that will vastly improve the quality of the results and optimally exploit our method.

79 ASTRONOMY AND ASTROPHYSICS↗

An alternative to Monte Carlo.

Histogram construction via algebraic Monte Carlo method, determining simultaneous effect of several input statistical variables on output variable

PROBABILITY THEORY↗

A hybrid approach to the neutron transport K-eigenvalue problem using NDA-based algorithms

In order to provide more physically accurate solutions to the neutron transport equation it has become increasingly popular to use Monte Carlo simulation to model nuclear reactor dynamics. These Monte Carlo methods can be extremely expensive, so we turn to a class of methods known as hybrid methods, which combine known deterministic and stochastic techniques to solve the transport equation. In our work, we show that we can simulate the action of a transport sweep using a Monte Carlo simulation in order to solve the k-eigenvalue problem. We'll accelerate the solution using nonlinear diffusion acceleration (NDA) as in [1,2]. Our work extends the results in [1] to use Monte Carlo simulation as the high-order solver. (authors)

97 MATHEMATICS AND COMPUTING↗

Validation of Varian TrueBeam electron phase–spaces for Monte Carlo simulation of MLC-shaped fields

Purpose: This work evaluates Varian’s electron phase–space sources for Monte Carlo simulation of the TrueBeam for modulated electron radiation therapy (MERT) and combined, modulated photon and electron radiation therapy (MPERT) where fields are shaped by the photon multileaf collimator (MLC) and delivered at 70 cm SSD. Methods: Monte Carlo simulations performed with EGSnrc-based BEAMnrc/DOSXYZnrc and PENELOPE-based PRIMO are compared against diode measurements for 5 × 5, 10 × 10, and 20 × 20 cm{sup 2} MLC-shaped fields delivered with 6, 12, and 20 MeV electrons at 70 cm SSD (jaws set to 40 × 40 cm{sup 2}). Depth dose curves and profiles are examined. In addition, EGSnrc-based simulations of relative output as a function of MLC-field size and jaw-position are compared against ion chamber measurements for MLC-shaped fields between 3 × 3 and 25 × 25 cm{sup 2} and jaw positions that range from the MLC-field size to 40 × 40 cm{sup 2}. Results: Percent depth dose curves generated by BEAMnrc/DOSXYZnrc and PRIMO agree with measurement within 2%, 2 mm except for PRIMO’s 12 MeV, 20 × 20 cm{sup 2} field where 90% of dose points agree within 2%, 2 mm. Without the distance to agreement, differences between measurement and simulation are as large as 7.3%. Characterization of simulated dose parameters such as FWHM, penumbra width and depths of 90%, 80%, 50%, and 20% dose agree within 2 mm of measurement for all fields except for the FWHM of the 6 MeV, 20 × 20 cm{sup 2} field which falls within 2 mm distance to agreement. Differences between simulation and measurement exist in the profile shoulders and penumbra tails, in particular for 10 × 10 and 20 × 20 cm{sup 2} fields of 20 MeV electrons, where both sets of simulated data fall short of measurement by as much as 3.5%. BEAMnrc/DOSXYZnrc simulated outputs agree with measurement within 2.3% except for 6 MeV MLC-shaped fields. Discrepancies here are as great as 5.5%. Conclusions: TrueBeam electron phase–spaces available from Varian have been implemented in two distinct Monte Carlo simulation packages to produce dose distributions and outputs that largely reflect measurement. Differences exist in the profile shoulders and penumbra tails for the 20 MeV phase–space off-axis and in the outputs for the 6 MeV phase–space.

07 ISOTOPE AND RADIATION SOURCES↗

Preliminary Results of a New Deterministic Iterative Image Reconstruction Algorithm - Paper 117

Iterative reconstruction techniques have become the standard for Single Photon Emission Computed Tomography (SPECT). Advances in computing have allowed these techniques to incorporate more and more detail; however, computation time must be balanced against increased detail. Monte Carlo methods are generally used for modeling the physics of a SPECT study, but can have long computation times. Advances in Monte Carlo-based scatter correction have shown reasonable results, but scatter estimation by measuring narrow energy windows remains more common. An iterative reconstruction technique using a deterministic transport code has been proposed as an alternative. This paper presents preliminary results of the new technique in which the TITAN deterministic code completes the forward projection step in a maximum likelihood expectation maximization (ML-EM) reconstruction of SPECT data. The effectiveness of the deterministic algorithm is examined for a 2-dimensional phantom. This work demonstrates the feasibility of using the TITAN code in an iterative reconstruction algorithm. The appropriate deterministic parameters were chosen by comparing sinograms produced with different mesh sizes, quadrature sets, and anisotropic scattering orders. The TITAN code was then successfully used as the forward projection step in an iterative reconstruction algorithm with a 2-dimensional homogeneous phantom. The impact of deterministic parameters on reconstruction quality is being investigated, along with the incorporation of a smoothing filter. The TITAN source code is being modified to include the ML-EM algorithm and iteration steps. This will significantly improve computation time by eliminating the repeated reading and writing of files for each iteration and allowing some steps to be completed in parallel. Further testing of the new reconstruction algorithm for more realistic phantoms is also underway. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Critical Relaxation of a Three-Dimensional Fully Frustrated Ising Model

Critical relaxation from the low-temperature ordered state of the three-dimensional fully frustrated Ising model on a simple cubic lattice is studied by the short-time dynamics method. Cubic systems with periodic boundary conditions and linear sizes of L = 32, 64, 96, and 128 in each crystallographic direction are studied. Calculations were carried out by the Monte Carlo method using the standard Metropolis algorithm. The static critical exponents for the magnetization and correlation radius and the dynamic critical exponents are calculated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Force-extension curves for broken-rod macromolecules: Dramatic effects of different probing methods for two and three rods

We study force-extension curves of a single semiflexible chain consisting of several rigid rods connected by flexible spacers. The atomic force microscopy and laser optical or magnetic tweezers apparatus stretching these rod-coil macromolecules are discussed. In addition, the stretching by external isotropic force is analyzed. The main attention is focused on computer simulation and analytical results. We demonstrate that the force-extension curves for rod-coil chains composed of two or three rods of equal length differ not only quantitatively but also qualitatively in different probe methods. These curves have an anomalous shape for a chain of two rods. End-to-end distributions of rod-coil chains are calculated by Monte Carlo method and compared with analytical equations. The influence of the spacer’s length on the force-extension curves in different probe methods is analyzed. The results can be useful for interpreting experiments on the stretching of rod-coil block-copolymers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-226: Correction of a Standard Model-Based Dose Calculator Using Measurement Data

Purpose: To propose a hybrid method that combines advantages of the model-based and measurement-based method for independent dose calculation. Modeled-based dose calculation, such as collapsed-cone-convolution/superposition (CCCS) or the Monte-Carlo method, models dose deposition in the patient body accurately; however, due to lack of detail knowledge about the linear accelerator (LINAC) head, commissioning for an arbitrary machine is tedious and challenging in case of hardware changes. On the contrary, the measurement-based method characterizes the beam property accurately but lacks the capability of dose disposition modeling in heterogeneous media. Methods: We used a standard CCCS calculator, which is commissioned by published data, as the standard model calculator. For a given machine, water phantom measurements were acquired. A set of dose distributions were also calculated using the CCCS for the same setup. The difference between the measurements and the CCCS results were tabulated and used as the commissioning data for a measurement based calculator. Here we used a direct-ray-tracing calculator (ΔDRT). The proposed independent dose calculation consists of the following steps: 1. calculate D-model using CCCS. 2. calculate D-ΔDRT using ΔDRT. 3. combine Results: D=D-model+D-ΔDRT. Results: The hybrid dose calculation was tested on digital phantoms and patient CT data for standard fields and IMRT plan. The results were compared to dose calculated by the treatment planning system (TPS). The agreement of the hybrid and the TPS was within 3%, 3 mm for over 98% of the volume for phantom studies and lung patients. Conclusion: The proposed hybrid method uses the same commissioning data as those for the measurement-based method and can be easily extended to any non-standard LINAC. The results met the accuracy, independence, and simple commissioning criteria for an independent dose calculator.

60 APPLIED LIFE SCIENCES↗

Efficient Monte Carlo event generation for neutrino-nucleus exclusive cross sections

Modern neutrino-nucleus cross section computations need to incorporate sophisticated nuclear models to achieve greater predictive precision. However, the computational complexity of these advanced models often limits their practicality for experimental analyses. To address this challenge, we introduce a new Monte Carlo method utilizing normalizing flows to generate surrogate cross sections that closely approximate those of the original model while significantly reducing computational overhead. As a case study, we built a Monte Carlo event generator for the neutrino-nucleus cross section model developed by the Ghent group. This model employs a Hartree-Fock procedure to establish a quantum mechanical framework in which both the bound and scattering nucleon states are solutions to the mean-field nuclear potential. The surrogate cross sections generated by our method demonstrate excellent accuracy with a relative effective sample size of more than 98.4%, providing a computationally efficient alternative to traditional Monte Carlo sampling methods for differential cross sections.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of Neutron Spectrum and Control Rod Worth Measurements in Several ZPPR-15 Loadings

This paper discusses the analysis of neutron spectrum and control rod reactivity worth measurements with deterministic and Monte Carlo methods. Deterministic results are obtained with 3D reactor models generated with the BuildZPRModel tools developed at ANL. The Monte Carlo simulations are performed with MCNP6 and are based on 3D models that include all geometric details ('as built' models). This study also shows the application of the cross section processing options recently implemented in BuildZPRModel that are based on the leakage and TWODANT method to take better into account the coupling effects among the different reactor zones.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Delivery validation of an automated modulated electron radiotherapy plan

Purpose: Modulated electron radiation therapy (MERT) represents an active area of interest that offers the potential to improve healthy tissue sparing in treatment of certain cancer cases. Challenges remain however in accurate beamlet dose calculation, plan optimization, collimation method, and delivery accuracy. In this work, the authors investigate the accuracy and efficiency of an end-to-end MERT plan and automated delivery method. Methods: Treatment planning was initiated on a previously treated whole breast irradiation case including an electron boost. All dose calculations were performed using Monte Carlo methods and beam weights were determined using a research-based treatment planning system capable of inverse optimization. The plan was delivered to radiochromic film placed in a water equivalent phantom for verification, using an automated motorized tertiary collimator. Results: The automated delivery, which covered four electron energies, 196 subfields, and 6183 total MU was completed in 25.8 min, including 6.2 min of beam-on time. The remainder of the delivery time was spent on collimator leaf motion and the automated interfacing with the accelerator in service mode. Comparison of the planned and delivered film dose gave 3%/3mm gamma pass rates of 62.1%, 99.8%, 97.8%, 98.3%, and 98.7% for the 9, 12, 16, and 20 MeV, and combined energy deliveries, respectively. Delivery was also performed with a MapCHECK device and resulted in 3%/3 mm gamma pass rates of 88.8%, 86.1%, 89.4%, and 94.8% for the 9, 12, 16, and 20 MeV energies, respectively. Conclusions: Results of the authors’ study showed that an accurate delivery utilizing an add-on tertiary electron collimator is possible using Monte Carlo calculated plans and inverse optimization, which brings MERT closer to becoming a viable option for physicians in treating superficial malignancies.

60 APPLIED LIFE SCIENCES↗

Bethe Approximation for a Two-Dimensional Spin-Pseudospin System

We have treated a two-dimensional spin-pseudospin model, which generalizes a diluted antiferromagnetic Ising model with charged nonmagnetic impurities in the case of two types of charges. The analytical results in the Bethe approximation are compared with the results of numerical simulation using the classical Monte Carlo method for various parameters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗