Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Audiovisual Fusion: Challenges and New Approaches

In this study, we review recent results on audiovisual (AV) fusion. We also discuss some of the challenges and report on approaches to address them. One important issue in AV fusion is how the modalities interact and influence each other. This review will address this question in the context of AV speech processing, and especially speech recognition, where one of the issues is that the modalities both interact but also sometimes appear to desynchronize from each other. An additional issue that sometimes arises is that one of the modalities may be missing at test time, although it is available at training time; for example, it may be possible to collect AV training data while only having access to audio at test time. We will review approaches to address this issue from the area of multiview learning, where the goal is to learn a model or representation for each of the modalities separately while taking advantage of the rich multimodal training data. In addition to multiview learning, we also discuss the recent application of deep learning (DL) toward AV fusion. We finally draw conclusions and offer our assessment of the future in the area of AV fusion.

47 OTHER INSTRUMENTATION↗

Electrodynamic Shaker Capability Estimation Through Experimental Dynamic Substructuring [Thesis]

Electrodynamic shaker systems are an essential tool in shock and vibration testing of dynamic environments. However, the specific performance capability of these systems is difficult to characterize. The dynamics of the shaker itself, the device under test and the specific test configuration used all couple to create a dynamic response unique to each test. Poorly predicted limitations in shaker capability affect the ability to achieve test specifications, delay testing schedules, and create difficulties for choosing test equipment. To predict shaker capability for a specific test configuration prior to setup, a lumped parameter model of the shaker system and a modal model of a device under test was developed. These models were then analytically coupled using LaGrange multiplier frequency based substructuring to estimate their coupled frequency response functions. The coupled frequency response functions were used to predict electrical inputs required to meet a given test specification. These input requirements were finally compared to a validation test using the specification and setup. Input requirements estimated using the substructuring estimated frequency response functions showed significant error. However, results using an ideal frequency response function showed very little error. These results indicate that with a better method of experimental dynamic substructuring employed it would be possible to accurately predict shaker capability for a given test configuration prior to setup.

42 ENGINEERING↗

Fan Noise Research at NASA

Results of recent NASA research to reduce aircraft turbofan noise are described. As the bypass ratio of a turbofan engine increases from five to as much as 20, the dominant source of engine noise is the fan. A primary mechanism of tone noise generation is the rotor blade wakes interacting with downstream stator vanes. Methods of analyzing rotor stator tone noise generation are described and sample results are given. The role of an acoustic modal description is emphasized. Wind tunnel tests of model fans and nacelles are described including a novel rotating microphone technique for modal measurement. Sample far field results are given showing the effects of inlet length, and modal measurements are shown which point to a new generation mechanism. Concepts for active fan noise control at the source are addressed. Implications of the research which have general relevance to fan noise generation and control are discussed.

Groeneweg, John F.↗

Fan noise research at NASA

Results of recent NASA research to reduce aircraft turbofan noise are described. As the bypass ratio of a turbofan engine increases from 5 to as much as 20, the dominant source of engine noise is the fan. A primary mechanism of tone noise generation is the rotor blade wakes interacting with downstream stator vanes. Methods of analyzing rotor-stator tone noise generation are described and sample results are given. The role of an acoustic modal description is emphasized. Wind tunnel tests of model fans and nacelles are described including a novel rotating microphone technique for modal measurement. Sample far field results are given showing the effects of inlet length, and modal measurements are shown which point to a new generation mechanism. Concepts for active fan noise control at the source are addressed. Implications of the research which have general relevance to fan noise generation and control are discussed.

Groeneweg, John F.↗

NASA-DoD Lead-Free Electronics Project: Vibration Test

Vibration testing was conducted by Boeing Research and Technology (Seattle) for the NASA-DoD Lead-Free Electronics Solder Project. This project is a follow-on to the Joint Council on Aging Aircraft/Joint Group on Pollution Prevention (JCAA/JG-PP) Lead-Free Solder Project which was the first group to test the reliability of lead-free solder joints against the requirements of the aerospace/miLItary community. Twenty seven test vehicles were subjected to the vibration test conditions (in two batches). The random vibration Power Spectral Density (PSD) input was increased during the test every 60 minutes in an effort to fail as many components as possible within the time allotted for the test. The solder joints on the components were electrically monitored using event detectors and any solder joint failures were recorded on a Labview-based data collection system. The number of test minutes required to fail a given component attached with SnPb solder was then compared to the number of test minutes required to fail the same component attached with lead-free solder. A complete modal analysis was conducted on one test vehicle using a laser vibrometer system which measured velocities, accelerations, and displacements at one . hundred points. The laser vibrometer data was used to determine the frequencies of the major modes of the test vehicle and the shapes of the modes. In addition, laser vibrometer data collected during the vibration test was used to calculate the strains generated by the first mode (using custom software). After completion of the testing, all of the test vehicles were visually inspected and cross sections were made. Broken component leads and other unwanted failure modes were documented.

Woodrow, Thomas A.↗

An automatic data system for vibration modal tuning and evaluation

A digitally based automatic modal tuning and analysis system developed to provide an operational capability beginning at 0.1 hertz is described. The elements of the system, which provides unique control features, maximum operator visibility, and rapid data reduction and documentation, are briefly described; and the operational flow is discussed to illustrate the full range of capabilities and the flexibility of application. The successful application of the system to a modal survey of the Skylab payload is described. Information about the Skylab test article, coincident-quadrature analysis of modal response data, orthogonality, and damping calculations is included in the appendixes. Recommendations for future application of the system are also made.

Salyer, R. A.↗

Shuttle Flight-7A DTO-261: Pre and Post Flight Analysis

This paper reports on the analysis to validate and correlate the analytical models of ISS-Shuttle Flight-7A configuration. On-orbit dynamic responses were measured during an intentional dynamic test (DTO-261) by the Shuttle video camera photogrammetric system and the Internal Wireless Instrumentation System (IWIS). Modal analyses were performed on the measured data to extract modal parameters including frequency, damping, and mode shapes. Correlation and comparisons between test and analytical modal parameters were performed to assess the accuracy of the models.

Kaouk, Mohamed↗

TRIPWIRE – Deployment and Field-Testing Report

TRIPWIRE is a multi-modal system for containment verification in inaccessible radiological and nuclear waste repositories. The sensing modes are focused on radiation, electromagnetic and vibration. The radiation detection component has been developed over the last three years at Idaho National Laboratory (INL). This development has focused on the fabrication, characterization, and testing of long-length (greater than 10-m) plastic scintillating fibers. This fiscal year, the focus of TRIPWIRE has been on field testing and demonstration of the radiation sensing component in a relevant environment. After reviewing the static storage facilities at INL, the Radioactive Scrap Waste Facility (RSWF) south storage area outside the Materials and Fuels Complex (MFC) was selected due to its periodic changes in configuration and inventory. This report summarizes the research outcomes for the work performed in fiscal year (FY) 2023.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Variation in the modal parameters of space structures

An analytic and experimental study of gravity and suspension influences on space structural test articles is presented. A modular test article including deployable, erectable, and rotary modules was assembled in three one- and two-dimensional structures. The two deployable modules utilized cable diagonal bracing rather than rigid cross members; within a bay of one of the deployable modules, the cable preload was adjustable. A friction lock was used on the alpha joint to either allow or prohibit rotary motion. Suspension systems with plunge fundamentals of 1, 2, and 5 Hz were used for ground testing to evaluate the influences of suspension stiffness. Assembly and reassembly testing was performed, as was testing on two separate shipsets at two test sites. Trends and statistical variances in modal parameters are presented as a function of force amplitude, joint preload, reassembly, shipset and suspension. Linear finite element modeling of each structure provided analytical results for 0-g unsuspended and 1-g suspended models, which are correlated with the analytical model.

Crawley, Edward F.↗

Application of a flight test and data analysis technique to flutter of a drone aircraft

Modal identification results are presented that were obtained from recent flight flutter tests of a drone vehicle with a research wing equipped with an active flutter suppression system (FSS). Frequency and damping of several modes are determined by a time domain modal analysis of the impulse response function obtained by Fourier transformations of data from fast swept sine wave excitation by the FSS control surfaces on the wing. Flutter points are determined for two different altitudes with the FSS off. Data are given for near the flutter boundary with the FSS on.

Bennett, R. M.↗

Design and Analysis of the International X-Ray Observatory Mirror Modules

The Soft X-Ray Telescope (SXT) modules are the fundamental focusing assemblies on NASA's next major X-ray telescope mission, the International X-Ray Observatory (IXO). The preliminary design and analysis of these assemblies has been completed, addressing the major engineering challenges and leading to an understanding of the factors effecting module performance. Each of the 60 modules in the Flight Mirror Assembly (FMA) supports 200-300 densely packed 0.4 mm thick glass mirror segments in order to meet the unprecedented effective area required to achieve the scientific objectives of the mission. Detailed Finite Element Analysis (FEA), materials testing, and environmental testing have been completed to ensure the modules can be successfully launched. Resulting stress margins are positive based on detailed FEA, a large factor of safety, and a design strength determined by robust characterization of the glass properties. FEA correlates well with the results of the successful modal, vibration, and acoustic environmental tests. Deformation of the module due to on-orbit thermal conditions is also a major design driver. A preliminary thermal control system has been designed and the sensitivity of module optical performance to various thermal loads has been determined using optomechanical analysis methods developed for this unique assembly. This design and analysis furthers the goal of building a module that demonstrates the ability to meet IXO requirements, which is the current focus of the IXO FMA technology development team.

McClelland, Ryan S.↗

International Space Station Model Correlation Analysis

This paper summarizes the on-orbit structural dynamic data and the related modal analysis, model validation and correlation performed for the International Space Station (ISS) configuration ISS Stage ULF7, 2015 Dedicated Thruster Firing (DTF). The objective of this analysis is to validate and correlate the analytical models used to calculate the ISS internal dynamic loads and compare the 2015 DTF with previous tests. During the ISS configurations under consideration, on-orbit dynamic measurements were collected using the three main ISS instrumentation systems; Internal Wireless Instrumentation System (IWIS), External Wireless Instrumentation System (EWIS) and the Structural Dynamic Measurement System (SDMS). The measurements were recorded during several nominal on-orbit DTF tests on August 18, 2015. Experimental modal analyses were performed on the measured data to extract modal parameters including frequency, damping, and mode shape information. Correlation and comparisons between test and analytical frequencies and mode shapes were performed to assess the accuracy of the analytical models for the configurations under consideration. These mode shapes were also compared to earlier tests. Based on the frequency comparisons, the accuracy of the mathematical models is assessed and model refinement recommendations are given. In particular, results of the first fundamental mode will be discussed, nonlinear results will be shown, and accelerometer placement will be assessed.

Modal Analysis↗

General parity-odd CMB bispectrum estimation

We develop a methodology for estimating parity-odd bispectra in the cosmic microwave background (CMB). This is achieved through the extension of the original separable modal methodology to parity-odd bispectrum domains (ℓ{sub 1}+ℓ{sub 2}+ℓ{sub 3} = odd). Through numerical tests of the parity-odd modal decomposition with some theoretical bispectrum templates, we verify that the parity-odd modal methodology can successfully reproduce the CMB bispectrum, without numerical instabilities. We also present simulated non-Gaussian maps produced by modal-decomposed parity-odd bispectra, and show the consistency with the exact results. Our new methodology is applicable to all types of parity-odd temperature and polarization bispectra.

79 ASTRONOMY AND ASTROPHYSICS↗

Initial Whirl-Flutter Characterization of the TiltRotor Aeroelastic Stability Testbed

This paper discusses the initial wind tunnel test of the TiltRotor Aeroelastic Stability Testbed (TRAST). TRAST is a generic tiltrotor testbed developed in collaboration between NASA and the Army. Ultimately, this test was a checkout of the model systems, functionality and familiarization, but also obtained subcritical whirl-flutter data in the terms of frequency and damping. Flutter data include two main configurations with different pitch spring stiffness, referred to as 4k and 8k, that were tested at various rotor speeds and airspeeds at the NASA Langley Transonic Dynamics Tunnel. The test included two modes of drivetrain operation: powered and windmilling. However, powered mode of operation was only conducted with the 8k pitch spring. This test reinforced the traditional knowledge of whirl-flutter trends such as flutter speed would decrease with an increase in rotor speed. The critical mode consistently being the wing vertical bending mode. The chord mode as expected was not affected by the pitch spring and was likely to go unstable at a tunnel airspeed slightly beyond the wing vertical bending mode. There were also test specific challenges such as the TRAST modal damping was more sensitive to temperature and amplitude motor than was expected. This test gathered valuable data on the baseline characterization of TRAST, how to improve the model and test practices for future wind tunnel testing. Additionally, a new more automated method for experimental subcritical damping determination based on the Stockwell transform has been demonstrated that may lead to more consistent whirl-flutter stability boundaries.

whirl flutter↗

Initial Characterization of the TiltRotor Aeroelastic Stability Testbed

This paper discusses the initial wind tunnel test of the TiltRotor Aeroelastic Stability Testbed (TRAST). TRAST is a generic tiltrotor testbed developed in collaboration between NASA and the Army. Ultimately, this test was a checkout of the model systems, functionality and familiarization, but also obtained subcritical whirl-flutter data in the terms of frequency and damping. Flutter data include two main configurations with different pitch spring stiffness, referred to as 4k and 8k, that were tested at various rotor speeds and airspeeds at the NASA Langley Transonic Dynamics Tunnel. The test included two modes of drivetrain operation: powered and windmilling. However, powered mode of operation was only conducted with the 8k pitch spring. This test reinforced the traditional knowledge of whirl-flutter trends such as flutter speed would decrease with an increase in rotor speed. The critical mode consistently being the wing vertical bending mode. The chord mode as expected was not affected by the pitch spring and was likely to go unstable at a tunnel airspeed slightly beyond the wing vertical bending mode. There were also test specific challenges such as the TRAST modal damping was more sensitive to temperature and amplitude motor than was expected. This test gathered valuable data on the baseline characterization of TRAST, how to improve the model and test practices for future wind tunnel testing. Additionally, a new more automated method for experimental subcritical damping determination based on the Stockwell transform has been demonstrated that may lead to more consistent whirl-flutter stability boundaries.

whirl flutter↗

Nonintrusive reduced order modeling framework for quasigeostrophic turbulence

In this study, we present a nonintrusive reduced order modeling (ROM) framework for large-scale quasistationary systems. The framework proposed in this work exploits the time series prediction capability of long short-term memory (LSTM) recurrent neural network architecture such that (1) in the training phase, the LSTM model is trained on the modal coefficients extracted from the high-resolution data snapshots using proper orthogonal decomposition (POD) transform, and (2) in the testing phase, the trained model predicts the modal coefficients for the total time recursively based on the initial time history. Hence, no prior information about the underlying governing equations is required to generate the ROM. To illustrate the predictive performance of the proposed framework, the mean flow fields and time series response of the field values are reconstructed from the predicted modal coefficients by using an inverse POD transform. As a representative benchmark test case, we consider a two-dimensional quasigeostrophic ocean circulation model which, in general, displays an enormous range of fluctuating spatial and temporal scales. We first demonstrate that the conventional Galerkin projection-based reduced order modeling of such systems requires a high number of POD modes to obtain a stable flow physics. In addition, ROM-Galerkin projection (ROM-GP) does not seem to capture the intermittent bursts appearing in the dynamics of the first few most energetic modes. However, the proposed nonintrusive ROM framework based on LSTM (ROM-LSTM) yields a stable solution even for a small number of POD modes. We also observe that the ROM-LSTM model is able to capture quasiperiodic intermittent bursts accurately, and yields a stable and accurate mean flow dynamics using the time history of a few previous time states, denoted as the lookback time window in this paper. We show several features of ROM-LSTM framework such as significantly higher accuracy than ROM-GP, and faster performance using larger time step size. Throughout the paper, we demonstrate our findings in terms of time series evolution of the field values and mean flow patterns, which suggest that the proposed fully nonintrusive ROM framework is robust and capable of predicting chaotic nonlinear fluid flows in an extremely efficient way compared to the conventional projection-based ROM framework.

42 ENGINEERING↗

Squeeze Film Damper Experimental and Numerical Correlation: Test Setup Description and Parameter Identification of Dry System

The process of characterizing a damper involves both experimental techniques and model simulation. Experiments characterize dynamic behavior of a system through empirical modal analysis using impact and shaker testing. The layout of the test setup is crucial for a low-mass, nonlinear system. Physical arrangement, orientation of the system, and instrumentation affect the results that are discussed in this paper. These results can be used to validate a numerical simulation of the same system. With a validated model, important physical input parameters and modeling techniques can be determined and implemented in future designs. In other words, this modeling can be used with confidence to design alternative dampers that may be difficult, costly, and time-consuming to characterize experimentally.

Cook, Jason↗

SU-E-T-28: A Treatment Planning Comparison of Volumetric Modulated Arc Therapy Vs. Proton Therapy for Post-Mastectomy Radiotherapy

Purpose: The delivery of post-mastectomy radiotherapy (PMRT) can be challenging for patients with left-sided breast cancer due to the PTV size and proximity to critical organs. This study investigates the use of protons for PMRT in a clinically-representative cohort of patients, and quantitatively compares volumetric modulated arc therapy (VMAT) to proton therapy to have an evidence-based rationale for selecting a treatment modality for these patients. Methods: Eight left-sided PMRT patients previously treated at our clinic with VMAT were identified for the study. PTVs included the chest wall and regional lymph nodes. Passively scattered (PS) and intensity modulated proton therapy (IMPT) plans were constructed using the Eclipse proton planning system. The resulting plans were compared to the original VMAT plan on the basis of PTV coverage; dose homogeneity index (DHI) and conformity index (CI); dose to organs at risk (OAR); tumor control probability (TCP), normal tissue complication probability (NTCP) and secondary cancer complication probability (SCCP). Differences were tested for significance using the paired Student's t-test (p<0.01). Results: All modalities produced clinically acceptable PMRT plans. The comparison demonstrated proton treatment plans provide significantly lower NTCP values for the heart and the lung while maintaining significantly better CI and DHI. At a prescribed dose of 50.4 Gy (RBE) in the PTV, the calculated mean NTCP value for the patients decreased from 1.3% to 0.05% for the whole heart (cardiac mortality) and from 3.8% to 1.1% for the lungs (radiation pneumonitis) for both proton therapy plans from VMAT plans. Both proton modalities showed a significantly lower SCCP for the contralateral breast compared to VMAT. Conclusion: All three plans (VMAT, PS, and IMPT) provide acceptable treatment plans for PMRT. However, proton therapy shows a significant advantage over VMAT with regards to sparing OARs and may be more advantageous for patients with unfavorable anatomy.

60 APPLIED LIFE SCIENCES↗