Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

An analysis of the control hierarchy modelling of the CMS detector control system

The supervisory level of the Detector Control System (DCS) of the CMS experiment is implemented using Finite State Machines (FSM), which model the behaviours and control the operations of all the sub-detectors and support services. The FSM tree of the whole CMS experiment consists of more than 30.000 nodes. An analysis of a system of such size is a complex task but is a crucial step towards the improvement of the overall performance of the FSM system. This paper presents the analysis of the CMS FSM system using the micro Common Representation Language 2 (mcrl2) methodology. Individual mCRL2 models are obtained for the FSM systems of the CMS sub-detectors using the ASF+SDF automated translation tool. Different mCRL2 operations are applied to the mCRL2 models. A mCRL2 simulation tool is used to closer examine the system. Visualization of a system based on the exploration of its state space is enabled with a mCRL2 tool. Requirements such as command and state propagation are expressed using modal mu-calculus and checked using a model checking algorithm. For checking local requirements such as endless loop freedom, the Bounded Model Checking technique is applied. This paper discusses these analysis techniques and presents the results of their application on the CMS FSM system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Different Score Index for Predicting Prognosis in Gamma Knife Radiosurgical Treatment for Brain Metastasis

Purpose: To assess the utility of the Radiation Therapy Oncology Group Recursive Partitioning Analysis (RPA) and Score Index for Radiosurgery (SIR) stratification systems in predicting survival in patients with brain metastasis treated with Gamma Knife radiosurgery (GKRS). Methods and Materials: A total of 185 patients were included in the study. Patients were stratified according to RPA and SIR classes. The RPA and SIR classes, age, Karnofsky Performance Status (KPS), and systemic disease were correlated with survival. Results: Five patients were lost to follow-up. Median survival in patients in RPA Class 1 (30 patients) was 17 months; in Class 2 (140 patients), 10 months; and in Class 3 (10 patients), 3 months. Median survival in patients in SIR Class 1 (30 patients) was 3 months; in Class 2 (135 patients), 8 months; and in Class 3 (15 patients), 20 months. In univariate testing, age younger than 65 years (p = 0.0004), KPS higher than 70 (p = 0.0001), RPA class (p = 0.0078), SIR class (p = 0.0002), and control of the primary tumor (p = 0.02) were significantly associated with improved outcome. In multivariate analysis, KPS (p < 0.0001), SIR class (p = 0.0008), and RPA class (p = 0.03) had statistical value. Conclusions: This study supports the use of GKRS as a single-treatment modality in this selected group of patients. Stratification systems are useful in the estimation of patient eligibility for GKRS. A second-line treatment was necessary in 30% of patients to achieve distal or local brain control. This strategy is useful to control brain metastasis in long-surviving patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integrated Imaging and Vision Techniques for Industrial Inspection: A Special Issue on Machine Vision and Applications

Imaging- and vision-based techniques play an important role in industrial inspection. The sophistication of the techniques assures high- quality performance of the manufacturing process through precise positioning, online monitoring, and real-time classification. Advanced systems incorporating multiple imaging and/or vision modalities provide robust solutions to complex situations and problems in industrial applications. A diverse range of industries, including aerospace, automotive, electronics, pharmaceutical, biomedical, semiconductor, and food/beverage, etc., have benefited from recent advances in multi-modal imaging, data fusion, and computer vision technologies. Many of the open problems in this context are in the general area of image analysis methodologies (preferably in an automated fashion). This editorial article introduces a special issue of this journal highlighting recent advances and demonstrating the successful applications of integrated imaging and vision technologies in industrial inspection.

data fusion↗

A call to standardize metrics for monitoring baleen whales near marine construction activities

Effective monitoring is necessary to protect marine mammal species during the construction of offshore infrastructure. The tools for detecting or monitoring marine mammals span traditional (e.g., visual observers, optical cameras), to newer (e.g., passive acoustic monitoring, infrared cameras, tags), and emerging (e.g., satellite imagery, environmental DNA, dimethyl sulfide concentration) technologies. Some are better suited for use during offshore development; however, peer-reviewed literature does not typically evaluate and report on the performance of these various technologies. We define a minimum set of metrics related to efficacy (i.e., confusion matrix, precision and recall, probability of missed mitigation), detection range (i.e., maximum and reliable detection range, spatial resolution), and data delivery (i.e., detection latency, system reliability, temporal resolution) that we recommend are needed to assess the utility of monitoring technologies for this purpose. Following a literature review of relevant studies, we highlight which publications reported these metrics and used multiple technologies to compare relative performance. We also emphasize the benefits of multi-modal approaches and recommend performance assessments through modeling or large-scale collaborative field testing. These metrics will standardize data collection, reporting, and analysis; promote consistent and comparable results; and foster collaboration among developers, regulatory agencies, and scientists. This may lead to the co-development of technology that achieves multiple goals, has greater application, and can answer research questions while collecting data to fulfill permitting requirements. These metrics may also inform decisions on what systems regulatory agencies might consider using and reduce monitoring costs, which is critical to support the marine sector's rapid growth alongside marine mammal conservation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optical Coherence Tomography and Raman Spectroscopy of the retina

Imaging the structure and correlating it with the biochemical content of the retina holds promise for fundamental research and for clinical applications. Optical coherence tomography (OCT) is commonly used to image the 3D structure of the retina and while the added functionality of biochemical analysis afforded by Raman scattering could provide critical molecular signatures for clinicians and researchers, there are many technical challenges to combining these imaging modalities. We present an ex vivo OCT microscope combined with Raman spectroscopy capable of collecting morphological and molecular information about a sample simultaneously. The combined instrument will be used to investigate remaining technical challenges to combine these imaging modalities, such as the laser power levels needed to achieve a Raman signal above the noise level without damaging the sample.

59 BASIC BIOLOGICAL SCIENCES↗

Chaotic dynamics of flexible Euler-Bernoulli beams

Mathematical modeling and analysis of spatio-temporal chaotic dynamics of flexible simple and curved Euler-Bernoulli beams are carried out. The Kármán-type geometric non-linearity is considered. Algorithms reducing partial differential equations which govern the dynamics of studied objects and associated boundary value problems are reduced to the Cauchy problem through both Finite Difference Method with the approximation of O(c{sup 2}) and Finite Element Method. The obtained Cauchy problem is solved via the fourth and sixth-order Runge-Kutta methods. Validity and reliability of the results are rigorously discussed. Analysis of the chaotic dynamics of flexible Euler-Bernoulli beams for a series of boundary conditions is carried out with the help of the qualitative theory of differential equations. We analyze time histories, phase and modal portraits, autocorrelation functions, the Poincaré and pseudo-Poincaré maps, signs of the first four Lyapunov exponents, as well as the compression factor of the phase volume of an attractor. A novel scenario of transition from periodicity to chaos is obtained, and a transition from chaos to hyper-chaos is illustrated. In particular, we study and explain the phenomenon of transition from symmetric to asymmetric vibrations. Vibration-type charts are given regarding two control parameters: amplitude q{sub 0} and frequency ω{sub p} of the uniformly distributed periodic excitation. Furthermore, we detected and illustrated how the so called temporal-space chaos is developed following the transition from regular to chaotic system dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Merkel Cell Carcinoma: 27-Year Experience at the Peter MacCallum Cancer Centre

Purpose: To retrospectively evaluate the treatment outcome of patients with Merkel cell carcinoma after local and/or regional treatment. Methods and Materials: Patients presenting to our center between January 1980 and July 2006 with Merkel cell carcinoma and without distant metastases were reviewed. The primary endpoint was locoregional control. Secondary endpoints were distant recurrence, survival and treatment toxicity. Results: A total of 176 patients were identified. The median age was 79 years. The median follow-up was 2.2 years for all patients and 3.9 years for those alive at the last follow-up visit. The most common primary site was the head and neck (56%), and 62 patients(35%) had regional disease at presentation. The initial surgery to the primary tumor involved (wide) local excision in 140 patients and biopsy only in 28 patients (8 patients had no identifiable primary tumor); 33 patients underwent nodal surgery. Of the 176 patients, 165 (94%) underwent radiotherapy (RT) and 29 of them also underwent concurrent chemotherapy. The median radiation dose was 50 Gy (range, 18-60). Locoregional recurrence developed in 33 patients(19%), with a median interval to recurrence of 8 months. Distant metastases developed in 43 patients(24%). Age, primary tumor size, and RT (no RT vs. <45 Gy vs. {>=}45 Gy) were predictive of locoregional control on univariate analysis. However, only RT remained significant on multivariate analysis. The estimated 5-year actuarial rate for locoregional control, progression-free survival, and overall survival was 76%, 60%, and 45%, respectively. Conclusion: The locoregional control rate for Merkel cell carcinoma in our study was comparable to those from other series using combined modality treatment with RT an integral part of treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Therapy for Primary Cutaneous Anaplastic Large Cell Lymphoma: An International Lymphoma Radiation Oncology Group Multi-institutional Experience

Purpose: To collect response rates of primary cutaneous anaplastic large cell lymphoma, a rare cutaneous T-cell lymphoma, to radiation therapy (RT), and to determine potential prognostic factors predictive of outcome. Methods and Materials: The study was a retrospective analysis of patients with primary cutaneous anaplastic large cell lymphoma who received RT as primary therapy or after surgical excision. Data collected include initial stage of disease, RT modality (electron/photon), total dose, fractionation, response to treatment, and local recurrence. Radiation therapy was delivered at 8 participating International Lymphoma Radiation Oncology Group institutions worldwide. Results: Fifty-six patients met the eligibility criteria, and 63 tumors were treated: head and neck (27%), trunk (14%), upper extremities (27%), and lower extremities (32%). Median tumor size was 2.25 cm (range, 0.6-12 cm). T classification included T1, 40 patients (71%); T2, 12 patients (21%); and T3, 4 patients (7%). The median radiation dose was 35 Gy (range, 6-45 Gy). Complete clinical response (CCR) was achieved in 60 of 63 tumors (95%) and partial response in 3 tumors (5%). After CCR, 1 tumor recurred locally (1.7%) after 36 Gy and 7 months after RT. This was the only patient to die of disease. Conclusions: Primary cutaneous anaplastic large cell lymphoma is a rare, indolent cutaneous lymphoma with a low death rate. This analysis, which was restricted to patients selected for treatment with radiation, indicates that achieving CCR was independent of radiation dose. Because there were too few failures (<2%) for statistical analysis on dose response, 30 Gy seems to be adequate for local control, and even lower doses may suffice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-A-16A-01: Image Quality for the Radiation Oncology Physicist: Review of the Fundamentals and Implementation

The expansion and integration of diagnostic imaging technologies such as On Board Imaging (OBI) and Cone Beam Computed Tomography (CBCT) into radiation oncology has required radiation oncology physicists to be responsible for and become familiar with assessing image quality. Unfortunately many radiation oncology physicists have had little or no training or experience in measuring and assessing image quality. Many physicists have turned to automated QA analysis software without having a fundamental understanding of image quality measures. This session will review the basic image quality measures of imaging technologies used in the radiation oncology clinic, such as low contrast resolution, high contrast resolution, uniformity, noise, and contrast scale, and how to measure and assess them in a meaningful way. Additionally a discussion of the implementation of an image quality assurance program in compliance with Task Group recommendations will be presented along with the advantages and disadvantages of automated analysis methods. Learning Objectives: Review and understanding of the fundamentals of image quality. Review and understanding of the basic image quality measures of imaging modalities used in the radiation oncology clinic. Understand how to implement an image quality assurance program and to assess basic image quality measures in a meaningful way.

07 ISOTOPE AND RADIATION SOURCES↗

WE-FG-202-03: Quantitative CT-Based Analysis to Assess Lung Injury Following Proton Radiotherapy

Purpose: Relative to photon alternatives, the increased dose-conformity associated with proton therapy is expected to reduce the extent of radiation-induced lung toxicity. However, analysis of follow-up data is yet to be published in this area. In this study we retrospectively analyzed late-phase HU changes for proton therapy cohorts of chest wall and lung patients. Methods: From our institution’s register of patients treated using double-scattered protons, all chest wall and stereotactic lung cases (treated 2011–2012 and 2008–2014 respectively) were initially considered. Follow-up CT data were accessible for 10 chest wall cases (prescribed 50.4 GyRBE in 28 fractions) and 16 lung cases (prescribed 42–50 GyRBE in 3–4 fractions). CT time-points ranged from 0.5–3.5 years post-treatment. Planning doses were recalculated using TOPAS Monte Carlo simulations and mapped onto the follow-up images using deformable registration. Excluding internal target volumes, changes in HU between each patient’s planning and follow-up CT(s) were evaluated for dose bins of 2–30 GyRBE (2 GyRBE increments). Results: Linear increases in HU per unit dose, with correlations statistically significant at the 1% level (one-sided Spearman’s rank test), were evident for all 10 chest wall cases and 14/16 lung cases. The mean changes in HU/Gy were: 1.76 (SD=0.73) for the chest wall cohort, and 1.40 (SD=0.87) for the lung cohort. The median scan times post treatment were 21 and 12 months respectively. All 26 patients developed solid consolidation (scar-like radiographic opacities) within the exposed lung(s). Conclusion: Analysis of follow-up CTs revealed statistically significant correlations in HU-change/dose for two proton cohorts (lung and chest wall). Quantitatively, the late-phase changes we report broadly match published photon data. Further analysis of such radiographic changes, particularly via matched cohort studies drawing upon consistent imaging protocols, could play an important role in elucidating inter-modality differences and provide insight into proton RBE for lung injury. Tracy Underwood gratefully acknowledges the support of the European Commission under an FP7 Marie Curie International Outgoing Fellowship for Career Development (#630064). This work was also funded under U19 grant CA 021239 (PI: Delaney).

60 APPLIED LIFE SCIENCES↗

Current measurements in the intermittent-contact mode of atomic force microscopy using the Fourier method: a feasibility analysis

Atomic force microscopy (AFM) is an important tool for measuring a variety of nanoscale surface properties, such as topography, viscoelasticity, electrical potential and conductivity. Some of these properties are measured using contact methods (static contact or intermittent contact), while others are measured using noncontact methods. Some properties can be measured using different approaches. Conductivity, in particular, is mapped using the contact-mode method. However, this modality can be destructive to delicate samples, since it involves continuously dragging the cantilever tip on the surface during the raster scan, while a constant tip–sample force is applied. In this paper we discuss a possible approach to develop an intermittent-contact conductive AFM mode based on Fourier analysis, whereby the measured current response consists of higher harmonics of the cantilever oscillation frequency. Such an approach may enable the characterization of soft samples with less damage than contact-mode imaging. To explore its feasibility, we derive the analytical form of the tip–sample current that would be obtained for attractive (noncontact) and repulsive (intermittent-contact) dynamic AFM characterization, and compare it with results obtained from numerical simulations. Although significant instrumentation challenges are anticipated, the modelling results are promising and suggest that Fourier-based higher-harmonics current measurement may enable the development of a reliable intermittent-contact conductive AFM method.

14 SOLAR ENERGY↗

Impact of Primary Gleason Grade on Risk Stratification for Gleason Score 7 Prostate Cancers

Purpose: To evaluate the primary Gleason grade (GG) in Gleason score (GS) 7 prostate cancers for risk of non-organ-confined disease with the goal of optimizing radiotherapy treatment option counseling. Methods: One thousand three hundred thirty-three patients with pathologic GS7 were identified in the Duke Prostate Center research database. Clinical factors including age, race, clinical stage, prostate-specific antigen at diagnosis, and pathologic stage were obtained. Data were stratified by prostate-specific antigen and clinical stage at diagnosis into adapted D'Amico risk groups. Univariate and multivariate analyses were performed evaluating for association of primary GG with pathologic outcome. Results: Nine hundred seventy-nine patients had primary GG3 and 354 had GG4. On univariate analyses, GG4 was associated with an increased risk of non-organ-confined disease. On multivariate analysis, GG4 was independently associated with seminal vesicle invasion (SVI) but not extracapsular extension. Patients with otherwise low-risk disease and primary GG3 had a very low risk of SVI (4%). Conclusions: Primary GG4 in GS7 cancers is associated with increased risk of SVI compared with primary GG3. Otherwise low-risk patients with GS 3+4 have a very low risk of SVI and may be candidates for prostate-only radiotherapy modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-441: Gamma Passing Rates for IMRT QA and VMAT QA

Purpose: This study compares gamma passing rates for a cohort of similar intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) quality assurance (QA) plans to determine the equivalence of the patient specific QA plan delivery. The passing criterion is 90% gamma index with 3% dose difference (DD), 3mm distance-to-agreement (DTA) and a dose threshold of 10%. Methods: Gamma passing results of previously treated IMRT QA plans, delivered to Sun Nuclear MapCheck phantom, and VMAT QA plans, delivered to ScandiDos Delta4 phantom, are organized by anatomical site and treatment machine. Both Varian and Elekta machines are included. Pairs of IMRT and VMAT plans are matched based on site, machine, and PTV volume to ensure similar plan cohorts. A two-tailed t-test analysis of the data with an alpha of 0.05 determines if there exists a statistically significant difference. Power was calculated to detect a difference of 4%; all data sets were strong with above a 0.8 power. Results: The first data set consisting of 20 matched pairs of prostate plans was statistically insignificant (p-value=0.90, Power=0.99). The 14 matched pairs set of head and neck plans has a statistically significant Result (p-value=0.028, Power=0.88). The head and neck IMRT gamma indexes have a mean of 93.1% and range of 82%-100% while the VMAT gamma indexes have a mean of 96.7% and range of 92%-100%. The two combined data sets of matched plans had a statistically insignificant Result (p-value=0.073, Power=0.99). Conclusion: Overall, IMRT and VMAT have equivalent passing rates when comparing the gamma analysis using a passing criterion of 3% DD and 3mm DTA. When separated by site, prostate IMRT and VMAT plans have equivalent passing rates while head and neck plans have a statistically significant variation of passing rates. The passing rates for the two modalities are independent of delivery machine for matched PTV target volumes.

60 APPLIED LIFE SCIENCES↗

Multi-Level Interval Estimation for Locating damage in Structures by Using Artificial Neural Networks

A new analysis technique, called multi-level interval estimation method, is developed for locating damage in structures. In this method, the artificial neural networks (ANN) analysis method is combined with the statistics theory to estimate the range of damage location. The ANN is multilayer perceptron trained by back-propagation. Natural frequencies and modal shape at a few selected points are used as input to identify the location and severity of damage. Considering the large-scale structures which have lots of elements, multi-level interval estimation method is developed to reduce the estimation range of damage location step-by-step. Every step, estimation range of damage location is obtained from the output of ANN by using the method of interval estimation. The next ANN training cases are selected from the estimation range after linear transform, and the output of new ANN estimation range of damage location will gained a reduced estimation range. Two numerical example analyses on 10-bar truss and 100-bar truss are presented to demonstrate the effectiveness of the proposed method.

97 MATHEMATICS AND COMPUTING↗

TU-G-303-00: Radiomics: Advances in the Use of Quantitative Imaging Used for Predictive Modeling

‘Radiomics’ refers to studies that extract a large amount of quantitative information from medical imaging studies as a basis for characterizing a specific aspect of patient health. Radiomics models can be built to address a wide range of outcome predictions, clinical decisions, basic cancer biology, etc. For example, radiomics models can be built to predict the aggressiveness of an imaged cancer, cancer gene expression characteristics (radiogenomics), radiation therapy treatment response, etc. Technically, radiomics brings together quantitative imaging, computer vision/image processing, and machine learning. In this symposium, speakers will discuss approaches to radiomics investigations, including: longitudinal radiomics, radiomics combined with other biomarkers (‘pan-omics’), radiomics for various imaging modalities (CT, MRI, and PET), and the use of registered multi-modality imaging datasets as a basis for radiomics. There are many challenges to the eventual use of radiomics-derived methods in clinical practice, including: standardization and robustness of selected metrics, accruing the data required, building and validating the resulting models, registering longitudinal data that often involve significant patient changes, reliable automated cancer segmentation tools, etc. Despite the hurdles, results achieved so far indicate the tremendous potential of this general approach to quantifying and using data from medical images. Specific applications of radiomics to be presented in this symposium will include: the longitudinal analysis of patients with low-grade gliomas; automatic detection and assessment of patients with metastatic bone lesions; image-based monitoring of patients with growing lymph nodes; predicting radiotherapy outcomes using multi-modality radiomics; and studies relating radiomics with genomics in lung cancer and glioblastoma. Learning Objectives: Understanding the basic image features that are often used in radiomic models. Understanding requirements for reliable radiomic models, including robustness of metrics, adequate predictive accuracy, and generalizability. Understanding the methodology behind radiomic-genomic (’radiogenomics’) correlations. Research supported by NIH (US), CIHR (Canada), and NSERC (Canada)

60 APPLIED LIFE SCIENCES↗

TU-G-303-01: Radiomics: Quantitative Imaging in the Service of Improved Treatment Decision Making

‘Radiomics’ refers to studies that extract a large amount of quantitative information from medical imaging studies as a basis for characterizing a specific aspect of patient health. Radiomics models can be built to address a wide range of outcome predictions, clinical decisions, basic cancer biology, etc. For example, radiomics models can be built to predict the aggressiveness of an imaged cancer, cancer gene expression characteristics (radiogenomics), radiation therapy treatment response, etc. Technically, radiomics brings together quantitative imaging, computer vision/image processing, and machine learning. In this symposium, speakers will discuss approaches to radiomics investigations, including: longitudinal radiomics, radiomics combined with other biomarkers (‘pan-omics’), radiomics for various imaging modalities (CT, MRI, and PET), and the use of registered multi-modality imaging datasets as a basis for radiomics. There are many challenges to the eventual use of radiomics-derived methods in clinical practice, including: standardization and robustness of selected metrics, accruing the data required, building and validating the resulting models, registering longitudinal data that often involve significant patient changes, reliable automated cancer segmentation tools, etc. Despite the hurdles, results achieved so far indicate the tremendous potential of this general approach to quantifying and using data from medical images. Specific applications of radiomics to be presented in this symposium will include: the longitudinal analysis of patients with low-grade gliomas; automatic detection and assessment of patients with metastatic bone lesions; image-based monitoring of patients with growing lymph nodes; predicting radiotherapy outcomes using multi-modality radiomics; and studies relating radiomics with genomics in lung cancer and glioblastoma. Learning Objectives: Understanding the basic image features that are often used in radiomic models. Understanding requirements for reliable radiomic models, including robustness of metrics, adequate predictive accuracy, and generalizability. Understanding the methodology behind radiomic-genomic (’radiogenomics’) correlations. Research supported by NIH (US), CIHR (Canada), and NSERC (Canada)

60 APPLIED LIFE SCIENCES↗

TU-G-303-02: Robust Radiomics Methods for PET and CT Imaging

‘Radiomics’ refers to studies that extract a large amount of quantitative information from medical imaging studies as a basis for characterizing a specific aspect of patient health. Radiomics models can be built to address a wide range of outcome predictions, clinical decisions, basic cancer biology, etc. For example, radiomics models can be built to predict the aggressiveness of an imaged cancer, cancer gene expression characteristics (radiogenomics), radiation therapy treatment response, etc. Technically, radiomics brings together quantitative imaging, computer vision/image processing, and machine learning. In this symposium, speakers will discuss approaches to radiomics investigations, including: longitudinal radiomics, radiomics combined with other biomarkers (‘pan-omics’), radiomics for various imaging modalities (CT, MRI, and PET), and the use of registered multi-modality imaging datasets as a basis for radiomics. There are many challenges to the eventual use of radiomics-derived methods in clinical practice, including: standardization and robustness of selected metrics, accruing the data required, building and validating the resulting models, registering longitudinal data that often involve significant patient changes, reliable automated cancer segmentation tools, etc. Despite the hurdles, results achieved so far indicate the tremendous potential of this general approach to quantifying and using data from medical images. Specific applications of radiomics to be presented in this symposium will include: the longitudinal analysis of patients with low-grade gliomas; automatic detection and assessment of patients with metastatic bone lesions; image-based monitoring of patients with growing lymph nodes; predicting radiotherapy outcomes using multi-modality radiomics; and studies relating radiomics with genomics in lung cancer and glioblastoma. Learning Objectives: Understanding the basic image features that are often used in radiomic models. Understanding requirements for reliable radiomic models, including robustness of metrics, adequate predictive accuracy, and generalizability. Understanding the methodology behind radiomic-genomic (’radiogenomics’) correlations. Research supported by NIH (US), CIHR (Canada), and NSERC (Canada)

60 APPLIED LIFE SCIENCES↗