Performance demonstration of vacuum microwave components critical for the operation of the ITER low-field side reflectometer

Final design studies in preparation for manufacturing have been performed for functional components of the vacuum portion of the ITER Low-Field Side Reflectometer (LFSR). These components consist of an antenna array, electron cyclotron heating (ECH) protection mirrors, phase calibration mirrors, and vacuum windows. Evaluation of these components was conducted at the LFSR test facility and DIII-D. The antenna array consists of six corrugated-waveguide antennas for simultaneous profile, fluctuation, and Doppler measurements. A diffraction grating, incorporated into the plasma-facing miter bend, provides protection of sensitive components from stray ECH at 170 GHz. For in situ phase calibration of the LFSR profile reflectometer, an embossed mirror is incorporated into the adjacent miter bend. Measurements of the radiated beam profile indicate that these components have a small, acceptable effect on mode conversion and beam quality. Baseline transmission characteristics of the dual-disk vacuum window are obtained and are used to guide ongoing developments. Preliminary simulations indicate that a surface-relief structure on the window surfaces can greatly improve transmission. The workability of real-time phase measurements was demonstrated on the DIII-D profile reflectometer. The new automated real-time analysis agrees well with the standard post-processing routine.

47 OTHER INSTRUMENTATION↗

System-on-chip approach microwave imaging reflectometer on DIII-D tokamak

System-on-chip millimeter wave integrated circuit technology is used on the two-dimensional millimeter-wave imaging reflectometer (MIR) upgrade for density fluctuation imaging on the DIII-D tokamak fusion plasma. Customized CMOS chips have been successfully developed for the transmitter module and receiver module array, covering the 55–75 GHz working band. The transmitter module has the capability of simultaneously launching eight tunable probe frequencies (>0 dBm output power each). The receiver enclosure contains 12 receiver modules in two vertical lines. The quasi-optical local oscillator coupling of previous MIR systems has been replaced with an internal active frequency multiplier chain for improved local oscillator power delivery and flexible installation in a narrow space together with improved shielding against electromagnetic interference. The 55–75 GHz low noise amplifier, used between the receiver antenna and the first-stage mixer, significantly improves module sensitivity and suppresses electronics noise. The receiver module has a 20 dB gain improvement compared with the mini-lens approach and better than –75 dBm sensitivity, and its electronics noise temperature has been reduced from 55 000 K down to 11 200 K. Further, the V-band MIR system is developed for co-located multi-field investigation of MHD-scale fluctuations in the pedestal region with W-band electron cyclotron emission imaging on DIII-D tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-mode analysis of surface losses in a superconducting microwave resonator in high magnetic fields

This paper reports on a surface impedance measurement of a bulk metal niobium–titanium superconducting radio frequency (SRF) cavity in a magnetic field (up to 10 T). Here, a novel method is employed to decompose the surface resistance contributions of the cylindrical cavity end caps and walls using measurements from multiple TM cavity modes. The results confirm that quality factor degradation of a NbTi SRF cavity in a high magnetic field is primarily from surfaces perpendicular to the field (the cavity end caps), while parallel surface resistances (the walls) remain relatively constant. This result is encouraging for applications needing high Q cavities in strong magnetic fields, such as the Axion Dark Matter eXperiment because it opens the possibility of hybrid SRF cavity construction to replace conventional copper cavities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ion concentration ratio measurements of ion beams generated by a commercial microwave electron cyclotron resonance plasma source

A commercially available electron cyclotron resonance (ECR) plasma source (GenII Plasma Source, tectra GmbH) is widely used for surface processing. This plasma source is compatible with ultrahigh vacuum systems, and its working pressure is relatively low, around 10 –6 –10 –4 Torr even without differential pumping. Here, we report ion flux concentration ratios for each ion species in an ion beam from this source, as measured by a mass/energy analyzer that is a combination of a quadrupole mass spectrometer, an electrostatic energy analyzer, and focusing ion optics. In this study, the examined beams were those arising from plasmas produced from feed gases of H 2 , D 2 , N 2 , O 2 , Ar, and dry air over a range of input power and working pressures. H 2 (D 2 ) plasmas are widely used for nuclear fusion applications and, hence, the ion concentration ratios of H + , H 2 + , and H 3 + reported here will be useful information for research that applies this plasma source to well-controlled plasma-material interaction studies. Ion energy distributions, stability of operation, and impurity concentrations were also assessed for each of the plasma species investigated.

47 OTHER INSTRUMENTATION↗

A perspective on nonlinear, microwave, and quantum photonics with Kerr microcombs

Microresonator Kerr optical frequency combs currently constitute a well-established research area in integrated, nonlinear, and quantum photonics. Furthermore, these systems have found a plethora of technological applications, while serving as an excellent platform to investigate fundamental scientific topics such as light–matter interactions, pattern formation in driven-dissipative systems, or entangled twin-photon generation. We here provide a brief overview of the topic, highlight some of the most recent advances, and discuss a few of the main challenges ahead in this field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evidence of gas phase nucleation of nanodiamond in microwave plasma assisted chemical vapor deposition

The mechanism of ballas-like nanodiamond formation still remains elusive, and this work attempts to analyze its formation in the framework of activation energy (Ea) of nanodiamond films grown from a H2/CH4 plasma in a 2.45 GHz chemical vapor deposition system. The Ea was calculated from the Arrhenius equation corresponding to the thickness growth rate using substrate temperature (∼1000−1300 K) in all the calculations. While the calculated values matched with the Ea for nanodiamond formation throughout the literature, these values of ∼10 kcal/mol were lower compared to ∼15–25 kcal/mol for standard single crystal diamond (SCD) formation, concluding thus far that the energetics and processes involved were different. Further, the substrate preparation and sample collection method were modified while keeping the growth parameters constant. Unseeded Si substrate was physically separated from the plasma discharge by a molybdenum disk with a pinhole drilled in it. Small quantity of a sample substance was collected on the substrate. The sample was characterized by electron microscopy and Raman spectroscopy, confirming it to be nanodiamond, thus suggesting that nanodiamond self-nucleated in the plasma and flowed to the substrate that acted as a mere collection plate. It is hypothesized then, if nanodiamond nucleates in gas phase, gas temperature has to be used in the Arrhenius analysis. The Ea values for all the nanodiamond films were re-calculated using the simulated gas temperature (∼1500−2000 K) obtained from a simple H2/CH4 plasma model, giving new values within the range characteristic to SCD formation. Based on these findings, a unified growth mechanism for nanodiamond and SCD is proposed, concluding that the rate-limiting reactions for nanodiamond and SCD formation are the same.

Materials Science↗

Plasma confinement state classification via FPP relevant microwave diagnostics

We present a parsimonious and robust machine learning approach for identifying plasma confinement states in fusion power plants (FPPs) where reliable identification of the low-confinement and high-confinement regimes is critical for safe and efficient operation. Unlike research-oriented devices, FPPs must operate with a severely constrained set of diagnostics. To address this challenge, we demonstrate that a minimalist model, using only electron cyclotron emission (ECE) signals, can achieve accurate and reliable state classification. ECE provides electron temperature profiles without the engineering or survivability issues of in-vessel probes, making it a primary candidate for FPP-relevant diagnostics. Our framework employs ECE as input, extracts features using radial basis functions, and applies a gradient boosting classifier, achieving a test accuracy of 96% (correct predictions). Robustness analysis and feature importance analyzes confirm the approach’s reliability. These results demonstrate that state-of-the-art performance is attainable from a restricted diagnostic set, paving the way for minimalist yet resilient plasma control architectures for FPPs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Atacama Cosmology Telescope: a measurement of the Cosmic Microwave Background power spectra at 98 and 150 GHz

We present the temperature and polarization angular power spectra of the CMB measured by the Atacama Cosmology Telescope (ACT) from 5400 deg2 of the 2013–2016 survey, which covers >15000 deg2 at 98 and 150 GHz. For this analysis we adopt a blinding strategy to help avoid confirmation bias and, related to this, show numerous checks for systematic error done before unblinding. Using the likelihood for the cosmological analysis we constrain secondary sources of anisotropy and foreground emission, and derive a “CMB-only” spectrum that extends to ℓ=4000. At large angular scales, foreground emission at 150 GHz is ∼1% of TT and EE within our selected regions and consistent with that found by Planck. Using the same likelihood, we obtain the cosmological parameters for ΛCDM for the ACT data alone with a prior on the optical depth of τ=0.065±0.015. ΛCDM is a good fit. The best-fit model has a reduced χ2 of 1.07 (PTE=0.07) with H0=67.9±1.5 km/s/Mpc. We show that the lensing BB signal is consistent with ΛCDM and limit the celestial EB polarization angle to ψP =−0.07ˆ±0.09ˆ. We directly cross correlate ACT with Planck and observe generally good agreement but with some discrepancies in TE. All data on which this analysis is based will be publicly released.

79 ASTRONOMY AND ASTROPHYSICS↗

The Atacama Cosmology Telescope: arcminute-resolution maps of 18 000 square degrees of the microwave sky from ACT 2008–2018 data combined with Planck

This paper presents a maximum-likelihood algorithm for combining sky maps with disparate sky coverage, angular resolution and spatially varying anisotropic noise into a single map of the sky. We use this to merge hundreds of individual maps covering the 2008–2018 ACT observing seasons, resulting in by far the deepest ACT maps released so far. We also combine the maps with the full Planck maps, resulting in maps that have the best features of both Planck and ACT: Planck’s nearly white noise on intermediate and large angular scales and ACT’s high-resolution and sensitivity on small angular scales. The maps cover over 18 000 square degrees, nearly half the full sky, at 100, 150 and 220 GHz. Furthermore, they reveal 4 000 optically-confirmed clusters through the Sunyaev Zel’dovich effect (SZ) and 18 500 point source candidates at > 5σ, the largest single collection of SZ clusters and millimeter wave sources to date. The multi-frequency maps provide millimeter images of nearby galaxies and individual Milky Way nebulae, and even clear detections of several nearby stars. Other anticipated uses of these maps include, for example, thermal SZ and kinematic SZ cluster stacking, CMB cluster lensing and galactic dust science. The method itself has negligible bias. However, due to the preliminary nature of some of the component data sets, we caution that these maps should not be used for precision cosmological analysis. The maps are part of ACT DR5, and will be made available on LAMBDA no later than three months after the journal publication of this article, along with an interactive sky atlas.

79 ASTRONOMY AND ASTROPHYSICS↗

On the use of dielectric elements in axion searches with microwave resonant cavities

This study explores the primary effects of dielectric materials in a resonant cavity-based search for axion dark matter. While dielectrics prove beneficial in numerous cases, their incorporation may lead to less-than-optimal performance, especially for the lowest TM mode. Additionally, the stronger confinement of the electric field inside the dielectrics can exacerbate mode mixings, in particular for higher-order modes. Case studies have been carried out using a combination of analytical solutions and numerical simulations. The findings indicate dielectric cavities employing the TM 010 mode experience a significant reduction in sensitivity when compared to a similar search conducted in a cavity at equivalent frequency using no dielectrics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for Postinflationary QCD Axions with a Quantum-Limited Tunable Microwave Receiver

A search for cosmological axions has been performed by scanning a frequency region of 38 MHz centered at about 10.2 GHz, corresponding to an axion mass 𝑚 𝑎 ≃ 42 μ ⁢eV. The QUAX experimental apparatus, a haloscope comprised of a 1-liter volume tunable cavity immersed in an 8 T magnetic field and a quantum-limited detection chain, set limits on the axion-photon coupling at the 10 −14 GeV −1 level. As no signal candidate has been observed, viable hadronic axion models are ruled out in a currently preferred postinflationary region 𝑚 𝑎 > 40 μ ⁢eV.

Sardo Infirri, Giosue [INFN, Sezione di Padova; Un↗

High- Q Microwave Dielectric Resonator for Axion Dark-Matter Haloscopes

The frequency band 1–15 GHz provides exciting prospects for resonant axion haloscopes as indicated by cosmological and astrophysical arguments. Among the challenges currently addressed to reach the required sensitivity, the development of high-quality factor cavities that tolerate multitesla fields plays a central role. We report a three-dimensional resonator based on a right-circular copper cavity with hollow cylinders that confine higher-order modes around the cylinder axis. Its effective volume at 10.3 GHz is 3.4 × 10 − 2 l, and under an 8-T field we measure an internal quality factor of more than nine million. A fine-tuning system limited to approximately 1 -MHz range is tested, useful for understanding the conditions required to run a haloscope with a cavity exceeding the axion quality factor. The cavity parameters we report demonstrate the potential of this unique resonator to probe galactic dark-matter axion at scan rates exceeding 2 MHz/day when the cavity is readout by a quantum-limited receiver.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗