Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microwave”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Spectral interferometry-based microwave-frequency vibrometry for integrated acoustic wave devices

Microwave phononics is a promising platform for sensing, computing, and quantum information science; thus, sensitive and high-throughput characterization tools are needed not only for device verification and optimization but also for revealing transient and nonlinear dynamics. Existing interferometric optical vibrometers for 2D mapping are challenged by operating point stabilization, surface reflectivity contrast, and long acquisition time. Here, we use spectral interferometry, which is insensitive to these factors and utilizes a continuous raster scanning scheme for vibration mapping with high throughput. We intensity-modulate our broadband light source with an electro-optic modulator to resolve vibrations at microwave frequencies. Our system requires no fast photodetector or digitizer operating in the microwave frequency range. We image the 1 GHz vibration field of a 300 × 150 µm 2 area of an entire surface acoustic wave device in 10 min with simultaneous surface profilometry. Our system has a vibration sensitivity of 120 fm/sqrt(Hz) and a linear throughput of 0.77 mm/s on the chip surface. The technique offers capabilities for characterizing a wide range of acoustic wave and micromechanical devices to better understand their behavior and performance.

47 OTHER INSTRUMENTATION↗

Analyzing Mechanical integrity of Microwave resonant Cavity flowmeter

The microwave resonant cavity flow sensor has been proposed to address the difficulties of measuring high-temperature molten salt flow in reactor vessels. The flow sensor consists of a metallic cylindrical cavity coupled to a microwave waveguide. The cylindrical cavity has one of the flat surfaces thin enough to undergo microscopic deflection due to dynamic pressure of the exerted by the flowing fluid. Deflection of the membrane causes a shift in the microwave resonant frequency. Fluid velocity can be estimated from the calibration curve. The objective of this report is to investigate mechanical integrity of the flowmeter’s membrane. The membrane is a thin stainless-steel circular plate with a clamped edge, subjected to uniform load. By calculating the stress on the plate due to deflection and, comparing the stress to the material ultimate tensile strength and yield strength, it can be estimated if the plate will fail. If the maximum stress is greater than the yield strength, the plate will undergo plastic deformation, and the sensor will be disabled. A stress greater than the ultimate tensile strength will cause the plate to fracture. The stress on the plate was calculated with an analytic closed form solution model, and with COMSOL Structural Mechanics Module which does not involve any approximations. Stresses in both the analytic model and COMSOL numerical model were calculated for stainless steel 316 thin circular plates under room temperature conditions, where the fluid is water. The diameter of the circular plate is approximately one inch, and thickness is 10mil. Fluid flow velocity is in the range from 0.5m/s to 1m/s. The results from the two models are similar. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Microwave-Assisted Conversion of 1,6-Hexanediol into Polycarbonate

The conversion of carbon dioxide into higher value chemicals is a viable way to support sustainability and net-zero economy goals. Of the different CO2 conversion routes, direct conversion offers a simplified process, lower reaction temperatures, and thus low energy input. Alcohols can be directly combined with CO2 to produce polycarbonates, e.g., DMC (dimethyl carbonate) formation from methanol and CO2. Recently CO2 and 1,6-hexanediol were shown to convert into poly(hexamethylene carbonate)diol using an atmospheric flow based process in single step. For these conversions, CeO2-based catalysts are widely used due to the abundance of oxygen vacancies that are believed to be the active sites for this reaction. Microwave (MW) heating is a unique approach that can provide selective volume-based heating and enhanced reaction rates and/or selectivities. For the current work, CO2 and diol conversion into polymers were investigated on different CeO2 catalysts under microwave heating and the performance was compared against conventional heating. The reaction products were analyzed using infrared spectroscopy (IR) and nuclear magnetic resonance (NMR) spectroscopy. Preliminary results showed microwaves irradiation produced faster rates of polycarbonate production as evidenced by IR data.

Kanitkar, Swarom↗

Microwave and rf Spectroscopy of 2D Carrier Systems and Bilayers (Final Technical Report)

We performed microwave spectroscopic studies of two dimensional electron systems (2DES) exhibiting the quantum Hall effect (QHE) in GaAs/Al${_x}$Ga$_{1-x}$As heterostructures. A common theme of the proposed work is electron solids, of which the simplest is the Wigner crystal, a triangular lattice of individual carriers. The solids are stabilized by carrier-carrier interaction and occur under conditions when the kinetic energy of the system is "frozen out" by high magnetic field, $B$. One of the main reasons for microwave spectroscopic study of 2DES is that the solid phases have striking microwave or rf spectra. In the low wave vector ($q$) limit these spectra exhibit a resonance that is understood as a pinning mode, a small collective oscillation of pieces of the solid within the disorder potential. Pinning modes can be very sharp, with quality factors up to around 30, and are valuable as signatures of the electron solids, and can reveal a solid even when standard dc transport shows an insulator, an integer QHE, or even a fractional QHE The pinning mode also is sensitive to the solid properties, and can reveal transitions between solids.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Decarbonizing Solvent Chemistry Through Microwave Processing [Abstract]

National Energy Technology Laboratory and Covestro LLC. will collaborate on a project titled, “Decarbonizing Solvent Chemistry Through Microwave Processing”, which was selected for funding by DOE’s Office of Energy Efficiency and Renewable Energy (EERE) Industrial Efficiency and Decarbonization Office (IEDO) FOA DE-EE0002997. The project aims to develop a microwave-based approach for low-heat aqueous-based industry-relevant reactions currently conducted using a conventional fossil-energy fueled hydrothermal reactor. The team has combined expertise in the areas of polymer production, microwave assisted reactions and scale-up, and life cycle analysis to perform the tasks proposed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing the combustion synthesis of FeAlxOy catalysts for microwave-assisted thermocatalytic dehydrogenation of fossil fuels

The growing demand for hydrogen requires the development of clean and energy-efficient technologies for its synthesis. Microwave-assisted thermocatalytic dehydrogenation of fossil fuels has demonstrated the potential to produce H2 with high yield and selectivity, and simultaneously generate valuable nanostructured carbon byproducts. In prior work, iron-based alumina (FeAlxOy) catalysts for this process were made via solution combustion synthesis (SCS). However, the effect of SCS parameters on the dehydrogenation performance is not well understood. The present study investigates this by varying the SCS fuel, Fe:Al molar ratio, and heating mode. The results show subtle changes of these parameters can result in significant differences in the phase composition, specific surface area, and microwave absorbing properties of FeAlxOy, which all affect microwave-assisted dehydrogenation. Notably, H2 selectivity can be increased from 30% to 74%. Statistical testing determined that the SCS fuel used was the most significant SCS parameter affecting dehydrogenation performance.

Chanoi, Zachary A.↗

All-optical, Microwave-free NV-Diamond Magnetometer for High Magnetic Field Environment

Nitrogen vacancy (NV) magnetometry has commonly utilized microwave sources to manipulate the sensor's spin state. However, this technique becomes technically challenging under an environment with a Tesla-scale magnetic field or extreme conditions that prohibit the usage of microwave. By leveraging the effect that an off-axis magnetic field to the NV axis quenches its emitted photoluminescence, we present an all-optical, microwave-free broadband quantum diamond magnetometer. We demonstrate magnetic sensing over an extended bias magnetic field range — beyond the ground-state level anti-crossing (GSLAC) region — with a more integrated design.

Zheng, Xiechen↗

Microwave-Mediated Extraction of Critical Metals from LED E-Waste

This study introduces a microwave-assisted technique for extracting critical minerals from LED electronic waste. The process begins with microwave irradiation, which thermally decomposes the LED’s plastic lens into a brittle, charred residue. During this stage, the LED chip undergoes deflagration—being rapidly ejected from the reflective cavity and becoming embedded within the decomposed lens material. Consequently, the chip is encapsulated in the resulting charred residue. This composite, consisting of the charred lens and the LED chip, can be easily separated from the metallic pins (Fe, Ni, Ag), which remain almost undamaged. Subsequent calcination of the charred material in air exposes the materials making up the LED chip, which contain critical metals (e.g., Ga, As, In, Y, Au). These metals are then extracted through a two-step acid leaching process involving aqua regia followed by hot concentrated hydrochloric acid, yielding them in potentially recoverable forms. The synergistic effect of microwave irradiation and acid treatment achieves an average extraction efficiency of 96% for critical metals. Notably, this approach enables complete and loss-free recovery of the LED chip, offering a practical and efficient solution for LED e-waste recycling.

Bourlinos, Athanasios B.↗

Total Recycling of Copper Cable Scrap and Production of Carbon Using Fast Microwave Technology

The recycling of cable scrap, particularly from discarded electrical wiring, is gaining significant attention due to the rising demand for copper and the need for sustainable management of electronic waste. Traditionally, mechanical and thermal processings have been used to recover copper and plastic from cables. However, these approaches are often energy-intensive, time-consuming, and costly in terms of equipment and labor. In this study, we present a simple and effective method for recovering materials from cable scrap using a domestic microwave oven. Cable pieces (2–2.5 cm long) were exposed to 700 W of microwave irradiation under rotation for 30 s, enabling the rapid and efficient separation of high-quality copper metal from the core wire, and activated carbon from the carbonized plastic sheath. Microwaves facilitate this process through Ohmic heating, which induces electrical resistance in the metal, generating heat that mechanically loosens the metal and carbonized plastic components. The process demonstrates high efficiency, achieving an 80% reduction in energy consumption compared to conventional processings. This fast and energy-efficient method shows strong potential for scaling up to industrial recycling, offering a cost-effective and environmentally friendly way to recover high-quality materials for further use or repurposing.

Bourlinos, Athanasios B. (ORCID:0000000256165993)↗

PAMTRA 1.0: the Passive and Active Microwave radiative TRAnsfer tool for simulating radiometer and radar measurements of the cloudy atmosphere

Forward models are a key tool to generate synthetic observations given knowledge of the atmospheric state. In this way, they are an integral part of inversion algorithms that aim to retrieve geophysical variables from observations or in data assimilation. Their application for the exploitation of the full information content of remote sensing observations becomes increasingly important when these are used to evaluate the performance of cloud-resolving models (CRMs). Herein, CRM profiles or fields provide the input to the forward model whose simulation results are subsequently compared to the observations. This paper introduces the freely available comprehensive microwave forward model PAMTRA (Passive and Active Microwave TRAnsfer), demonstrates its capabilities to simulate passive and active measurements across the microwave spectral region for upward- and downward-looking geometries, and illustrates how the forward simulations can be used to evaluate CRMs and to interpret measurements to improve our understanding of cloud processes. PAMTRA is unique as it treats passive and active radiative transfer (RT) in a consistent way with the passive forward model providing upwelling and downwelling polarized brightness temperatures and radiances for arbitrary observation angles. The active part is capable of simulating the full radar Doppler spectrum and its moments. PAMTRA is designed to be flexible with respect to instrument specifications and interfaces to many different formats of input and output, especially CRMs, spanning the range from bin-resolved microphysical output to one- and two-moment schemes, and to in situ measured hydrometeor properties. A specific highlight is the incorporation of the self-similar Rayleigh–Gans approximation (SSRGA) for both active and passive applications, which becomes especially important for the investigation of frozen hydrometeors.

54 ENVIRONMENTAL SCIENCES↗

Estimation of microwave absorption in the Jupiter atmosphere

A procedure for estimating the microwave absorption loss of the Jupiter atmosphere is presented. Estimation of microwave absorption by planetary atmospheres involves two different investigative disciplines (1) the determination of an acceptable model of the atmosphere itself and (2) the determination of the microwave attenuation rate applicable to each different volume sample of the atmosphere, and the integration of this loss over the varying radio propagation path for any given entry trajectory to obtain the total loss.

Coombs, W. C.↗

Soil moisture measurements with microwave, radiometers

One technique of measuring moisture content that appears promising is that of microwave radiometry. In the microwave region of the spectrum, the emissivity of water is approximately 0.4, whereas that of dry soil is approximately 0.9. Therefore, the emissivity of the soil can range from about 0.6 to 0.9 as the soil changes from a wet to a dry condition. Recent ground base measurements have demonstrated emissivity changes of this magnitude. To test the use of this approach for remote sensing of soil moisture, flights were made over agricultural test sites in the vicinity of Phoenix, Ariz., during late February 1971. On the same day, soil moisture measurements were made on the ground for 200 fields. On board the aircraft were six microwave radiometers, ranging in wavelength from 21 cm to 8 mm. The results of one of these radiometers are presented.

Schmugge, T. J.↗

Microwave emission from geological materials - Observations of interference effects.

Microwave radiometric field observations were conducted at wavelengths of 21, 2.8, and 0.95 cm to determine the microwave penetration depth of a number of sands and gravels as a function of particle size and moisture content. Observations of a reflecting plate covered with varying thicknesses of test material exhibit a pronounced oscillatory behavior that is consistent with established electromagnetic theory for plane-parallel layered mediums. Utilization of this interference effect is proposed as a microwave radiometric technique for determining the bulk electrical properties of geologic materials, snow, ice, and other materials readily adapted to layering experiments.

Blinn, J. C., III↗

Remote monitoring of soil moisture using airborne microwave radiometers

The current status of microwave radiometry is provided. The fundamentals of the microwave radiometer are reviewed with particular reference to airborne operations, and the interpretative procedures normally used for the modeling of the apparent temperature are presented. Airborne microwave radiometer measurements were made over selected flight lines in Chickasha, Oklahoma and Weslaco, Texas. Extensive ground measurements of soil moisture were made in support of the aircraft mission over the two locations. In addition, laboratory determination of the complex permittivities of soil samples taken from the flight lines were made with varying moisture contents. The data were analyzed to determine the degree of correlation between measured apparent temperatures and soil moisture content.

Kroll, C. L.↗

A search for periodic structure in solar 2 cm microwave radiation

A power spectral analysis of 285 hr of 2 cm microwave intensity data showed no statistically significant ( 96% confidence) periodicities in the frequency range 1 to 15 mHz. No correlation was found between 2 cm periodicities and solar activity in H alpha, X-ray, and several microwave frequencies. A small shift of power toward higher frequencies in the power spectrum of the 2 cm data was found to be correlated with solar H alpha and X-ray activity. Using the statistical properties of power spectra, an expression for the ratio of the minimum detectable peak-to-peak to ambient temperature at chromospheric heights may be derived. Applied to a model for oscillation bursts in quiescent supergranules, and using the most significant results of experiments to detect the microwave periodicities, this expression yields an upper limit of approximately .0015.

Sentman, D. D.↗

Passive microwave images of lake ice

Photographic data and microwave emission images from the Great Lake ice formation are compared for their applicability to commercial shipping interests. A synoptic view of the microwave radiation from the lake area ice shows a large variation in brightness temperature. The snow ice appears to have the highest microwave brightness temperatures, whereas the thick clear ice shows up some 30 degrees kelvin colder, and the thin clear ice is colder still with a 1.55 cm radiation.

Gloersen, P.↗

Electrically scanning microwave radiometer for Nimbus E

An electronically scanning microwave radiometer system has been designed, developed, and tested for measurement of meteorological, geomorphological and oceanographic parameters from NASA/GSFC's Nimbus E satellite. The system is a completely integrated radiometer designed to measure the microwave brightness temperature of the earth and its atmosphere at a microwave frequency of 19.35 GHz. Calibration and environmental testing of the system have successfully demonstrated its ability to perform accurate measurements in a satellite environment. The successful launch and data acquisition of the Nimbus 5 (formerly Nimbus E) gives further demonstration to its achievement.

Source record↗

Analysis of ground tests of a microwave, earth-occultation, pressure-reference-level system.

A two-satellite, microwave, earth-occultation system can supplement an infrared sensor by providing an accurate altitude reference that will serve to fix, as a function of height, the derived temperature profile of the infrared sounder. The results of ground tests made in Hawaii to estimate the likely effects of scintillation and fading on an occultation system are described. It was found that the microwave signal suffered periods of intense fading; extensive computer analyses of the data were performed in which aircraft-generated refractivity profiles were subjected to ray tracing. Results of these analyses indicate that the probable cause of the observed fading was multipath, a low-altitude phenomenon usually attributed to water vapor inhomogeneities. It is maintained that multipath will therefore have minimal effect on the pressure-reference microwave occultation system, which would operate at a relatively high closest-approach altitude (about 8 km).

Ungar, S. G.↗