Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mass Spectrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Hydrocarbons identified in extracts from estuarine water accommodated no. 2 fuel oil by gas chromatography-mass spectrometry

Results are presented on a computerized gas chromatograph-mass spectrometer analysis of methylene chloride and n-heptane extracts of a No. 2 fuel oil accommodated estuarine water sample. The analytical method is briefly described, and the limitations on the identifications are categorized. Some attempt was made to determine major and trace constituents in the water accommodate. Altogether 66 hydrocarbon compounds were identified specifically, and 75 compounds were partially identified. Seven compounds could be recognized as major constituents of the water accommodated oil and ten were present only as traces. The aromatic compounds found were alkyl benzenes, naphthalene, tetralin, indane, biphenyl, fluorene, anthracene, and some of their alkyl substituted isomers in the range of carbon numbers C7 to C15. Four n-alkanes, C10 to C13, were found along with four other assorted hydrocarbons.

Lewis, B. W.↗

Mass spectrometry in the stratosphere

A gas expansion system incorporating a mass spectrometer that has been successfully flown in the stratosphere is described. Neutral gas particles are formed into a molecular beam that traverses the ion source of the mass spectrometer without wall interactions. It is noted that vertical profiles of such constituents as H2O, CO2, and O3 have been measured in the altitude range of 20 to 40 km during balloon descents. Isotopes of important gases (N2, O2, Ar) provided in-flight calibration standards. Before each flight the mass spectrometer system is calibrated in the laboratory for many gases of interest, including ozone. Mixing ratios of ozone established from recent flights have accuracies of better than 5 percent. The sensitivity of the system is sufficient to detect as well the heavy isotope of ozone at mass 50. A noticeable enhancement of heavy ozone in the upper stratosphere has been found. The mass spectrometer system is seen as providing a unique opportunity to perform in situ measurements in the stratosphere in combination with isotopic studies.

Mauersberger, K.↗

Application of mass spectrometry to process control for polymer material in autoclave curing

Mass spectrometer analysis of gas samples collected during a cure cycle of polymer materials can be used as a process control technique. This technique is particularly helpful in studying the various types of solvents and resin systems used in the preparation of polymer materials and characterizing the chemical composition of different resin systems and their mechanism of polymerization.

Smith, A. C.↗

Laser Time-of-Flight Mass Spectrometry for Space

A miniature reflection time-of-flight mass spectrometer for in situ planetary surface analysis is described. The laser ablation mass spectrometer (LAMS) measures the regolith's elemental and isotopic composition without high-voltage source extraction or sample preparation. The compact size (< 2 x 10(exp 3) cubic cm) and low mass (approximately 2 kg) of LAMS, due to its fully coaxial design and two-stage reflectron, fall within the strict resource limitations of landed science missions to solar system bodies. A short-pulse laser focused to a spot with a diameter approximately 30-50 micrometers is used to obtain microscopic surface samples. Assisted by a microimager, LAMS can interactively select and analyze a range of compositional regions (with lateral motion) and with repeated pulses can access unweathered, subsurface materials. The mass resolution is calibrated to distinguish isotopic peaks at unit masses, and detection limits are on resolved to a few ppm. The design and calibration method of a prototype LAMS device is described, which include the development of preliminary relative sensitivity coefficients for major element bulk abundance measurements.

Brinckerhoff, W. B.↗

A multiomics mass spectrometry workflow for fast and comprehensive strain optimization (Abstract CRADA 726 )

The Agile Biofoundry (ABF) is a multi-national lab consortium funded by the DOE Bioenergy Technologies Office that has developed a biofoundry that enables the rapid deployment of bioproducts into the market. The ABF is a flexible platform that can adjust to the needs of numerous government, academic and industrial partners, thus enabling them to rapidly develop and optimize the production of a wide range of bioproducts. To enhance this capability, PNNL and Agilent Technologies are collaborating to expand and demonstrate a prototype system that processes hundreds of samples per day by liquid chromatography-mass spectrometry-based untargeted and targeted methods, and artificial intelligence software for multiomics applications, including metabolomics, lipidomics and proteomics.

Bilbao, Aivett (ORCID:0000000329858249)↗

Discovering type I cis-AT polyketides through computational mass spectrometry and genome mining with Seq2PKS

Type 1 polyketides are a major class of natural products used as antiviral, antibiotic, antifungal, antiparasitic, immunosuppressive, and antitumor drugs. Analysis of public microbial genomes leads to the discovery of over sixty thousand type 1 polyketide gene clusters. However, the molecular products of only about a hundred of these clusters are characterized, leaving most metabolites unknown. Characterizing polyketides relies on bioactivity-guided purification, which is expensive and time-consuming. To address this, we present Seq2PKS, a machine learning algorithm that predicts chemical structures derived from Type 1 polyketide synthases. Seq2PKS predicts numerous putative structures for each gene cluster to enhance accuracy. The correct structure is identified using a variable mass spectral database search. Benchmarks show that Seq2PKS outperforms existing methods. Applying Seq2PKS to Actinobacteria datasets, we discover biosynthetic gene clusters for monazomycin, oasomycin A, and 2-aminobenzamide-actiphenol.

60 APPLIED LIFE SCIENCES↗

An Experimental Method to Measure Gaseous Diffusivity in Tight and Partially Saturated Porous Media via Continuously Monitored Mass Spectrometry

Detection of radioxenon and radioargon produced by underground nuclear explosions is one of the primary methods by which the Comprehensive Nuclear-Test–Ban Treaty (CTBT) monitors for nuclear activities. However, transport of these noble gases to the surface via barometric pumping is a complex process relying on advective and diffusive processes in a fractured porous medium to bring detectable levels to the surface. To better understand this process, experimental measurements of noble gas and chemical surrogate diffusivity in relevant lithologies are necessary. However, measurement of noble gas diffusivity in tight or partially saturated porous media is challenging due to the transparent nature of noble gases, the lengthy diffusion times, and difficulty maintaining consistent water saturation. Here, the quasi-steady-state Ney–Armistead method is modified to accommodate continuous gas sampling via effusive flow to a mass spectrometer. An analytical solution accounting for the cumulative sampling losses and induced advective flow is then derived. Experimental results appear in good agreement with the proposed theory, suggesting the presence of retained groundwater reduces the effective diffusivity of the gas tracers by 10–1000 times. Finally, by using a mass spectrometer, the method described herein is applicable to a broad range of gas species and porous media.

47 OTHER INSTRUMENTATION↗

Towards Portable Laser Desorption Postionization Mass Spectrometry Utilizing Microchip Laser Pulses

A 355 nm, 1.5 ns, up to 1 kHz microchip laser system has been tested to both yield ablation spots and postionize material within a plasma plume. A 30 µJ pulse energy microchip laser successfully ablated all samples: 6601 aluminum, 316 and 304 stainless steel, and Mo metal. While visible ablation craters were observed on all samples mentioned above, the stainless-steel samples displayed visible color changes in the resolidified iron, indicating ionization with the 355 nm pulses during ablation. Additionally, when used to intercept a plasma plume of Cs 2 CO 3 made with a separate laser system, the microchip laser pulses yielded Cs + emission signal otherwise not observed. With these experiments completed, the microchip laser has been successfully verified for readiness to be integrated into the front end of a mass spectrometer system as the ion source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analyses via automated mass spectrometry (MS/DS)

New or improved uses of the Finnigan 4000 quadrupole mass spectrometer (MS) with its associated INCOS data system (DS) were investigated. The first phase involved an evaluative activity in which specific problems with miscalibration and gas chromatographic column conditioning were identified. This also revealed one solution to the problem of detection of substances not visible in the gas chromatography detection mode. A second phase was to seek useful applications of the direct inlet systems. This mode of sample introduction has not been previously utilized on the existing equipment and was successfully applied to the analysis of the components of TONOX 60/40 and in the thermal degradation products of some polymeric materials. Suggestions are made for improving and expanding the use of the MS/DS system in materials development and testing.

Koenig, T.↗

Monitoring of space station life support systems with miniature mass spectrometry and artificial intelligence

The combination of quadrupole ion trap tandem mass spectroscopy with artificial intelligence is a promising approach for monitoring the performance of the life support systems in the space station. Such an analytical system can provide the selectivity, sensitivity, speed, small size, and decision making intelligence to detect, identify, and quantify trace toxic compounds which may accumulate in the space station habitat.

Yost, Richard A.↗