Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MHZ RANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

An initial assessment of the performance achieved by the Seasat-1 radar altimeter

This paper describes the results of an initial on-orbit engineering assessment of the performance achieved by the radar altimeter system flown on Seasat-1. Additionally, the general design characteristics of this system are discussed and illustrations of altimeter data products are provided. The instrument consists of a 13.5-GHz monostatic radar system that tracks in range only using a 1-m parabolic antenna pointed at the satellite nadir. Two of its unique features are a linear FM transmitter with 320-MHz bandwidth, which yields a 3.125-ns time-delay resolution, and microprocessor-implemented closed-loop range tracking, automatic gain control (AGC), and real-time estimation of significant wave height (SWH). Results presented herein show that the altimeter generally performed in accordance with its original performance requirements of measuring altitude to a precision of less than 10-cm rms, SWH to an accuracy of plus or minus 0.5 m or 10 percent whichever is greater, and ocean backscatter coefficient to an accuracy of plus or minus 1 dB, all over an SWH range of 1 to 20 m.

Townsend, W. F.↗

Overview of the ICRF heating system in SPARC

Ion Cyclotron Range of Frequencies (ICRF) heating is a critical system for the SPARC mission of demonstrating net positive fusion gain. In the first campaign, 20 MW of installed power at 120 MHz will be supplied to 10 four-strap antennas, arranged in poloidal pairs. The matching network is designed to accommodate for a range of loading conditions and a fast controller adjusts the matching during a pulse with frequency modulation of ±1 MHz. For the main L-mode scenario of the first experimental campaign, the power coupling and absorption is analysed in this work. Several feeding schemes are compared and limits on the amount of the total coupled power are evaluated. Coupling of the full 20 MW power is possible well within the limit of the peak electric field in the transmission line of 15 kV/cm. The 3 He minority and 2 nd harmonic T heating scheme is validated in full-wave modelling to be efficient for heating plasma in the SPARC L-mode Q>1 scenario, with dominant ion heating and efficient single-pass absorption. A range of ICRF wave parameters and minority concentration would be suitable for operation and allow tailoring the heating properties for plasma conditions and experimental objectives.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Broadband Characterization and Circuit Model Development of Transmission-Scale Transformers

This report describes broadband measurements of transmission-scale transformers typical in the electric power grid. This work was performed as part of the EMP Resilient Grid LDRD project at Sandia National Laboratories to generate circuit models that can be used for high-altitude electromagnetic pulse (HEMP) coupling simulations and response predictions. The objective of the work was to obtain characterization data of substation yard equipment across a frequency range relevant to HEMP. Vector network analyzer measurements up to 100 MHz were performed on two power transformers at ABB-Hitachi and a single ITEC potential transformer. Custom cable breakouts were designed to interface with the transformer terminals and provide ground connections to the chassis at the base of the transformer bushings. The three-phase terminals of the power transformers were measured as a common mode impedance using a parallel resistive splitter, and the single-phase terminals of the potential transformer were measured directly. A vector fitting algorithm was used to empirically fit circuit models to the resulting two-port networks and input impedances of the measured objects. Simplified circuit representations of the input impedances were also generated to assess the degree of precision needed for high-altitude electromagnetic pulse response predictions, which were performed in Sandia's XYCE circuit simulator platform. HEMP coupling simulations using the transformer models showed significant reduction in the voltage peak and broadening in the pulse width seen at the power transformer compared to the traveling wave voltage. This indicated the importance of the load condition when defining the coupled insult in an electric power substation. Simplified circuit models showed a similar voltage at the transformer with a smoothed waveform. The presence of potential transformers in the simulation did not significantly change the simulated voltage at the power transformer. Single-port input impedance models were also developed to define load conditions when transfer characteristics were not necessary.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Latitudinal beaming of Jupiter's low frequency radio emissions

Observations of Jupiter's radio emissions from Jovigraphic latitudes greater than 3.3 deg are reported. The measurements were obtained from the Voyager 2 spacecraft at declinations up to 6.5 deg, and when these results are compared with simultaneous observations from Voyager 1 near the ecliptic plane (at a Jovigraphic latitude of about 3 deg), they indicate that the latitudinal-beaming effects persist and may even become stronger with higher latitudes. The results were combined with earlier low-frequency measurements from periods with De as low as -3 deg in order to show the beaming effects the occurrence of the emission over a full 10 deg range of altitude. The results of observations at frequencies near 1 MHz are also discussed, which were obtained from Voyager 1 and 2 in 1978, Rae 1 in 1969, and Imp 6 in 1971-1972. The implications of the new results for models of Jupiter's radio-emission beam pattern are considered.

Alexander, J. K.↗

Fine altitude resolution radar observations of upper-tropospheric and lower-stratospheric winds and waves

Preliminary results of wind velocity measurements made using the Arecibo 430 MHz radar are presented. These measurements were made in the altitude range between 10 and 30 km, with a time resolution of 1-2 min, and an improved altitude resolution of 150 m. A few interesting phenomena such as a quasi-stationary wavy structure and short period sinusoidal oscillations are discussed.

Sato, T.↗

Source region of low-speed wind

We have been carrying out the interplanetary scintillation observations at a frequency of 327 MHz. The IPS measurements at this frequency can probe the distance range of 0.1-1 AU. We will report on source regions of the low-speed winds which were observed within 0.3 AU by the IPS method. The source regions of low-speed winds have been studied. In 1991, two spacecraft of Sakigake and IMP observed two low-speed streams in one solar rotation, which originated from a magnetic neutral line on the source surface. However speeds are slightly different from each other: one is 300 km/s while the other one is 400 km/s. Similar speed difference was also observed by the IPS method. We examined differences of these source regions in the soft X-ray images observed by the Yohkoh satellite. At the source region of the lower speed wind, sun spots were found under the neutral line, while nothing except the neutral line was found for the higher speed wind. We made a synoptic chart of the solar wind speeds which were observed within 0.3 AU. In this chart, compact regions of very low speed can be found clearly, and the amplitude of a low-speed belt is smaller than that of a magnetic neutral line. Distribution of the low-speed belt is rather suited above active regions than on a neutral line calculated by the potential field model.

Watanabe, H.↗

A Low Frequency Radio and Radar Instrument to Explore Jupiter's Icy Moons

The addition of a comprehensive wave investigation to the Jupiter Icy Moons Orbiter (JIMO) science payload will provide a broad range of information on the icy moons of Jupiter including the detection of subsurface liquid oceans; mapping of their ionospheres; their interaction with the magnetospheric environment; and on the Jovian magnetosphere. These measurements are obtained through the use of both passive and active (sounding) means over broad frequency ranges. The frequency range of interest extends from less than 1 Hz to 40 MHz for passive measurements, from approximately 1 kHz to a few MHz for magnetospheric and ionospheric sounding, and between 1 and approximately 10 MHz for subsurface radar sounding. An instrument to detect subsurface radar sounding, magnetospheric interactions, and ionospheric sounding is discussed.

Kurth, W. S.↗

The effect of magnetic susceptibility and magnetic field strength on porosity estimates determined from low-field nuclear magnetic resonance

The presence of materials with high magnetic susceptibility are known to have an impact on 1H nuclear magnetic resonance (NMR) measurements and in laboratory data this often results in poor estimates of porosity from NMR data. To quantify and understand the cause of the poor NMR porosity estimations, in this laboratory study, we examine the effect of magnetic susceptibility, NMR measurement parameters, and NMR instrument design on NMR measurements. Data were collected with two instruments, each with a different Larmor frequency (2 MHz and 485 kHz), on water-saturated unconsolidated sediments with magnetic susceptibility values ranging from 3.6 × 10 -6 to 7020 × 10 -6 SI. The results show that for materials with low magnetic susceptibility (<378 × 10 -6 SI), the gravimetric porosity is accurately predicted from the NMR measurements. For the samples with high magnetic susceptibility (>987 × 10 -6 SI) the gravimetric porosity is poorly predicted from the 2 MHz NMR measurements made at all echo times (from 0.2 to 3.0 ms). In contrast, the gravimetric porosity is more accurately predicted at an echo time of 0.2 ms for measurements made using the 485 kHz instrument, although at larger echo times (>1.0 ms), the porosity estimate becomes poor. The 485 kHz NMR instrument has non-zero internal magnetic field gradients, similar to those found in borehole instruments, in contrast to the 2 MHz NMR instrument, which has a homogeneous applied magnetic field. Finally, we conclude that differences is the magnetic field strength and higher magnetic field inhomogeneities in the 485 kHz NMR instrument contribute to a reduction of the impact of inhomogeneities in the magnetic field caused by materials with high magnetic susceptibility, allowing for improved porosity estimation. These results indicate that NMR measurements collected at short echo times in low, inhomogeneous static fields, e.g., borehole instruments, may provide accurate estimates of porosity in water saturated sediments, even in the presence of magnetic minerals.

58 GEOSCIENCES↗

Bistatic image processing for a 32 x 19 inch model aircraft using scattered fields obtained in the OSU-ESL compact range

Inverse Synthetic Aperture Radar (ISAR) images for a 32 in long and 19 in wide model aircraft are documented. Both backscattered and bistatic scattered fields of this model aircraft were measured in the OSU-ESL compact range to obtain these images. The scattered fields of the target were measured for frequencies from 2 to 18 GHz with a 10 MHz increment and for full 360 deg azimuth rotation angles with a 0.2 deg step. For the bistatic scattering measurement, the compact range was used as the transmitting antenna; while, a broad band AEL double ridge horn was used as the receiving antenna. Bistatic angles of 90 deg and 135 deg were measured. Due to the size of the chamber and target, the receiving antenna was in the near field of the target; nevertheless, the image processing algorithm was valid for this case.

Lee, T-H.↗

High-Frequency Focused Water-Coupled Ultrasound Used for Three-Dimensional Surface Depression Profiling

To interface with other solids, many surfaces are engineered via methods such as plating, coating, and machining to produce a functional surface ensuring successful end products. In addition, subsurface properties such as hardness, residual stress, deformation, chemical composition, and microstructure are often linked to surface characteristics. Surface topography, therefore, contains the signatures of the surface and possibly links to volumetric properties, and as a result serves as a vital link between surface design, manufacturing, and performance. Hence, surface topography can be used to diagnose, monitor, and control fabrication methods. At the NASA Glenn Research Center, the measurement of surface topography is important in developing high-temperature structural materials and for profiling the surface changes of materials during microgravity combustion experiments. A prior study demonstrated that focused air-coupled ultrasound at 1 MHz could profile surfaces with a 25-m depth resolution and a 400-m lateral resolution over a 1.4-mm depth range. In this work, we address the question of whether higher frequency focused water-coupled ultrasound can improve on these specifications. To this end, we employed 10- and 25-MHz focused ultrasonic transducers in the water-coupled mode. The surface profile results seen in this investigation for 25-MHz water-coupled ultrasound, in comparison to those for 1-MHz air-coupled ultrasound, represent an 8 times improvement in depth resolution (3 vs. 25 m seen in practice), an improvement of at least 2 times in lateral resolution (180 vs. 400 m calculated and observed in practice), and an improvement in vertical depth range of 4 times (calculated).

Roth, Don J.↗

Real-time steerable frequency-stepped Doppler backscattering (DBS) system for local helicon wave electric field measurements on the DIII-D tokamak

A new frequency-stepped Doppler backscattering (DBS) system has been integrated into a real-time steerable electron cyclotron heating launcher system to simultaneously probe local background turbulence (f < 10 MHz) and high-frequency (20–550 MHz) density fluctuations in the DIII-D tokamak. The launcher allows for 2D steering (horizontally and vertically) over wide angular ranges to optimize probe location and wavenumber response. The vertical steering can be optimized during a discharge in real time. The new DBS system employs a programmable frequency synthesizer with adjustable dwell time as a source to launch either O or X-mode polarized millimeter waves. This system can step in real-time over the entire E-band frequency range (60–90 GHz). This combination of capabilities allows for the diagnosis of the complex internal spatial structure of high power (>200 kW) helicon waves (476 MHz) injected from an external antenna during helicon current drive experiments in DIII-D. Broadband density fluctuations around the helicon frequency are observed during real-time scans of measurement location and wavenumber during these experiments. Analysis indicates that these broadband high-frequency fluctuations are a result of backscattering of the DBS millimeter-wave probe beam from plasma turbulence modulated by the helicon wave. It is observed that background turbulence is effectively locally “tagged” with the helicon wave electric field, forming images of the turbulent spectrum in the overall density fluctuation spectrum that appear as high-frequency sidebands of the turbulence. These observations of background turbulence and high-frequency fluctuations open up the possibility of monitoring local helicon wave amplitude by comparing the high-frequency signal amplitude to the simultaneously measured background turbulence. In combination with the real-time measurement location and wavenumber scanning capabilities (offered by real-time frequency-stepping and steering), this allows rapid determination of the spatial distribution of the helicon wave power during steady-state plasma operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using High Frequency Focused Water-Coupled Ultrasound for 3-D Surface Depression Profiling

Surface topography is an important variable in the performance of many industrial components and is normally measured with diamond-tip profilometry over a small area or using optical scattering methods for larger area measurement. A prior study was performed demonstrating that focused air-coupled ultrasound at 1 MHz was capable of profiling surfaces with 25 micron depth resolution and 400 micron lateral resolution over a 1.4 mm depth range. In this article, the question of whether higher-frequency focused water-coupled ultrasound can improve on these specifications is addressed. 10 and 25 MHz focused ultrasonic transducers were employed in the water-coupled mode. Time-of-flight images of the sample surface were acquired and converted to depth / surface profile images using the simple relation (d = V*t/2) between distance (d), time-of-flight (t), and the velocity of sound in water (V). Results are compared for the two frequencies used and with those from the 1 MHz air-coupled configuration.

Roth, Don J.↗

New limit on dark photon kinetic mixing in the 0.2 – 1.2 μ eV mass range from the Dark E-field Radio experiment

We report new limits on the kinetic mixing strength of the dark photon spanning the mass range 0.21 − 1.24 μ eV corresponding to a frequency span of 50–300 MHz. The Dark E-field Radio experiment is a wideband search for dark photon dark matter. In this paper we detail changes in calibration and upgrades since our proof-of-concept pilot run. Our detector employs a wide-bandwidth E-field antenna moved to multiple positions in a shielded room, a low noise amplifier, wideband analog-to-digital converter, followed by a 2 24 -point fast Fourier transform. An optimal filter searches for signals with Q ≈ 10 6 . In nine days of integration, this system is capable of detecting dark photon signals corresponding to a kinetic mixing strength ε several orders of magnitude lower than previous limits. We find a 95% exclusion limit on ε over this mass range between 6 × 10 − 15 and 6 × 10 − 13 , tracking the complex resonant mode structure in the shielded room. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

A high-resolution clock phase shifter circuitry for ALTIROC

Abstract A high-resolution clock phase shifter is implemented to adjust the phase of multiple clocks at 40 MHz, 80 MHz, or 640 MHz in the ALTIROC chip. The phase shifter has a coarse-phase shifter and a fine-phase shifter to achieve a step size of 97.7 ps and an adjustable range of 25 ns. The fine delay unit is based on a Delay Locked Loop (DLL) operating at 640 MHz. The phase shifter is fabricated in a 130 nm CMOS process. The area of the phase shifter is 725 µm × 248 µm. The Differential Non-Linearity (DNL) and the Integral Non-Linearity (INL) are ±0.6 LSB and ±0.75 LSB, respectively. The jitter from −25 °C to 20 °C is less than 15.5 ps (RMS), including the contributions from the FPGA clock source and the PLL. The power consumption is 11.2 mW.

Instruments & Instrumentation↗

10 kV Class 14 MHz Isolated Power Supply

This paper presents a single-switch based isolated power supply, utilizing a PCB based core-less transformer to achieve high inter-winding isolation and low common-mode capacitance. Detailed design procedure, considering the transformer to achieve full range ZVS, minimize voltage stress and minimize RMS currents is presented. The proposed methodology is experimentally validated at 14 MHz, with a load variation of 10:1 in output power and a maximum output power of 4 W. The proposed power supply is useful in applications such as MV gate drives and sensors.

Tessaro Andrade, Elvey [ORNL] (ORCID:0009000225919↗

Low SWaP Semiconductor Laser Transmitter Modules For ASCENDS Mission Applications

The National Research Council's (NRC) Decadal Survey (DS) of Earth Science and Applications from Space has identified the Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) as an important atmospheric science mission. NASA Langley Research Center, working with its partners, is developing fiber laser architecture based intensity modulated CW laser absorption spectrometer for measuring XCO2 in the 1571 nm spectral band. In support of this measurement, remote sensing of O2 in the 1260 nm spectral band for surface pressure measurements is also being developed. In this paper, we will present recent progress made in the development of advanced transmitter modules for CO2 and O2 sensing. Advanced DFB seed laser modules incorporating low-noise variable laser bias current supply and low-noise variable temperature control circuit have been developed. The 1571 nm modules operate at >80 mW and could be tuned continuously over the wavelength range of 1569-1574nm at a rate of 2 pm/mV. Fine tuning was demonstrated by adjusting the laser drive at a rate of 0.7 pm/mV. Heterodyne linewidth measurements have been performed showing linewidth ~200 kHz and frequency jitter ~75 MHz. In the case of 1260 nm DFB laser modules, we have shown continuous tuning over a range of 1261.4 - 1262.6 nm by changing chip operating temperature and 1261.0 - 1262.0 nm by changing the laser diode drive level. In addition, we have created a new laser package configuration which has been shown to improve the TEC coefficient of performance by a factor of 5 and improved the overall efficiency of the laser module by a factor of 2.

Prasad, Narasimha S.↗

Tuning the dynamics in Fe 3 O 4 nanoparticles for hyperthermia optimization

The AC magnetic susceptibility (ACS) of Fe 3 O 4 nanoparticles was measured between 10 kHz and 4 MHz at different temperatures and in applied DC fields. In this frequency range, magnetostatic interactions impact magnetization dynamics even for dilute assemblies. The ACS spectrum of relaxation frequencies changes both with temperature and the addition of a small DC field. Because both the relaxation peak frequency and amplitude can be tuned with the DC field, these results could be applied to magnetic hyperthermia applications to optimize heat delivery.

Physics↗

Ion dynamics in hexagonal boron nitride ionogel electrolytes

Ionogel electrolytes incorporating exfoliated hexagonal boron nitride (hBN) nanoplatelets are promising materials for next-generation energy storage systems. However, detailed understanding of their ion transport properties at the molecular level remains limited. This study employs diffusion and relaxation nuclear magnetic resonance (NMR) techniques, including fast-field cycling (FFC) NMR, to investigate the dynamics of ionic species in hBN-ionogels. By spanning a broad frequency range from 30 kHz using FFC NMR to high-field NMR (500–800 MHz), we reveal distinct relaxation mechanisms governing ion dynamics in ionogels with and without lithium salts. Our results highlight the role of hBN in modulating molecular rotation and translational motion, significantly affecting 1 H and 19 F relaxation profiles. The presence of Li + alters the dynamic behavior in ionogels, enhancing anion mobility at the interface. Notably, 7 Li relaxation reveals strong interactions with the hBN surface that cannot be detected by diffusion NMR. Furthermore, these findings underscore the importance of spanning a broad frequency range in NMR studies of ionogels and provide critical insights into optimizing their design as novel electrolytes.

Electrolytes↗