Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASS RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Mass ejection from the O4f star Zeta Puppis

Profiles of P Cygni lines and displaced absorption lines observed in high-resolution Copernicus UV scans of Zeta Pup from 907 to 1738 A are compared with profile calculations to derive an optical-depth scale of the lines as a function of height or velocity in the expanding envelope. The degrees of ionization of the elements C, N, O, Si, and S under equilibrium conditions at electron temperatures of 20,000 to 1 million K, radiation temperatures of 20,000 to 50,000 K, and electron number densities of 100 million to 1 trillion per cu cm are computed with a dilution factor of 0.1, taking into account collisional ionization by electrons, radiative ionization from the ground state, radiative recombination, and dielectric recombination. Observed and predicted relative ionization fractions are then compared to determine the electron and radiation temperatures. Crude and refined estimates of the mass-loss rate and velocity law are made, and radiative acceleration in the expanding envelope is analyzed. The derived model for Zeta Pup is found to have a mass-loss rate of about 7.2 millionths of a solar mass per year, a wind velocity that increases slowly outward and reaches 700 km/s about 28 solar masses, and a nearly isothermal envelope with an electron temperature of approximately 200,000 K.

Lamers, H. J. G. L. M.↗

IUE investigation of mass flow in the interacting binary U Sagittae

Fifteen far-UV and 13 mid-UV high-resolution spectra of the interacting Algol-type binary U Sagittae have been obtained with the IUE satellite. The resonance lines of Si IV and C IV are present in absorption of moderate strength at all phases. At several phases, weak absorption due to the N V resonance lines is present. The high-temperature pseudophotospheric region which is found surrounding the equatorial regions of the primary star in all active Algol-type binaries is present in U Sge, indicating that it is not as dormant as once believed. This is also consistent with recent ground-based studies.

Mccluskey, George E., Jr.↗

The Einstein Observatory - New perspectives in astronomy

The impact of high-resolution, high-sensitivity X-ray measurements obtained by the Einstein Observatory (HEAO-2) on various areas of astronomical research is discussed. Following a review of the Einstein instruments based on grazing incidence focusing X-ray optics, including the telescope, imaging detectors and spectrometers, consideration is given to observations of X-ray emission from stellar systems, galaxies, and clusters of galaxies. Einstein results concerning the X-ray luminosities of young O, B and A stars and late K and M stars, the temperature, composition and distribution of material ejected in supernova explosions and comprising the interstellar medium, the formation and evolution of stellar systems and galaxies, the energy source of quasars and active galactic nuclei and the mass distribution in galactic clusters are indicated. Substantial progress made possible by the high-resolution observations of the diffuse X-ray background in cosmological research is also noted.

Giacconi, R.↗

Measurements of mass flow in the transition region and inner corona

A solar rocket experiment launched on June 5, 1979 is described which provides high spectral resolution line profiles across the solar disk. The instrument consists of a small telescope with moderate spatial resolution and a spectrograph with stability and high spectroscopic resolution (about 0.028 A at 600 A). The detector system uses a microchannel plate array to provide 1,024 simultaneous measurements spanning approximately 30 A of the solar spectrum. The spectrograph uses a 3600 l/mm grating, and the spectral range 609-634 A is recorded in second order overlapping 1218-1268 A in first order. The position of the emission lines is determined by a center-of-mass routine and velocity shifts are evident. The qualitative results are in general agreement with the results of Cushman and Rense (1976).

Rottman, G. J.↗

High resolution CO images of Seyfert Galaxies

The CO (J = 1-0) emission of three Seyfert galaxies, NGC 3227, NGC 7469, and NGC 5033 was imaged. The CO emission in NGC 3227 and NGC 7469 appears as compact structures centered on the active nuclei, containing substantial fractions of the single-dish flux. In NGC 3227, 10 percent of the CO flux detected by the interferometer is contained within the ionized narrow-line region. The unresolved molecular gas concentrations in the nucleus of NGC 3227 imply a CO mass of 65 million solar masses concentrated within a diameter less than 50 pc. The CO emission in NGC 5033 is not detected at this resolution, implying a CO structure size of 20 to 60 arcsec. Continuum emission at 2.7 mm is not detected in any of the three galaxies. In the center of NGC 7469, the H2 mass is comparable to the dynamical mass. Kinematic studies of the detected gas reveal a rotational motion of the gas in NGC 3227 and NGC 7469, allowing identification of the gas in NGC 7469 with a nuclear starburst. These data are consistent with the idea that interactions between galaxies cause gas to concentrate in their nuclei thereby feeding starburst and Seyfert activity.

Meixner, M.↗

Seasonal Tidewater Glacier Terminus Oscillations Bias Multi-Decadal Projections of Ice Mass Change

Numerical, process-based simulations of tidewater glacier evolution are necessary to project future sea-level change under various climate scenarios. Previous work has shown that nonlinearities in tidewater glacier and ice stream dynamics can lead to biases in simulated ice mass change in the presence of noisy forcings. Ice sheet modeling projections that are used in the IPCC Assessment Report 6 (AR6) utilize atmospheric and oceanic forcings at annual temporal resolution, omitting any higher frequency forcings. Here, we quantify the effect of seasonal (<1 year) tidewater glacier terminus oscillations on decadal-scale (30 years) mass change. We use an idealized geometry to mimic realistic tidewater glacier geometries and investigate the impact of the magnitude of seasonal oscillations, bed slope at the glacier terminus, and basal friction law. We find that omitting seasonal terminus motion results in biased mass change projections, with up to an 39% underestimate or 25% overestimate of mass loss when seasonality is neglected, depending on bed slope and magnitude of oscillations. The bias is most sensitive to the magnitude of the seasonal terminus oscillations and exhibits very little sensitivity to choice of friction law. Although omitting seasonal terminus motion may bias mass change projections of individual glaciers, further work is needed to investigate the impact on ice sheet mass change projections. In order to achieve this, seasonality in atmospheric and oceanic forcings must be adequately represented and observations of seasonal terminus positions and tidewater glacier thickness changes must be acquired to evaluate numerical models. Note: Zip folder contains all videos listed in the supplemental document and can be downloaded for viewing.

D. Felikson↗

Derivation and Validation of Supraglacial Lake Volumes on the Greenland Ice Sheet from High-Resolution Satellite Imagery

Supraglacial meltwater lakes on the western Greenland Ice Sheet (GrIS) are critical components of its surface hydrology and surface mass balance, and they also affect its ice dynamics. Estimates of lake volume, however, are limited by the availability of in situ measurements of water depth,which in turn also limits the assessment of remotely sensed lake depths. Given the logistical difficulty of collecting physical bathymetric measurements, methods relying upon in situ data are generally restricted to small areas and thus their application to largescale studies is difficult to validate. Here, we produce and validate spaceborne estimates of supraglacial lake volumes across a relatively large area (1250 km(exp 2) of west Greenland's ablation region using data acquired by the WorldView-2 (WV-2) sensor, making use of both its stereo-imaging capability and its meter-scale resolution. We employ spectrally-derived depth retrieval models, which are either based on absolute reflectance (single-channel model) or a ratio of spectral reflectances in two bands (dual-channel model). These models are calibrated by usingWV-2multispectral imagery acquired early in the melt season and depth measurements from a high resolutionWV-2 DEM over the same lake basins when devoid of water. The calibrated models are then validated with different lakes in the area, for which we determined depths. Lake depth estimates based on measurements recorded in WV-2's blue (450-510 nm), green (510-580 nm), and red (630-690 nm) bands and dual-channel modes (blue/green, blue/red, and green/red band combinations) had near-zero bias, an average root-mean-squared deviation of 0.4 m (relative to post-drainage DEMs), and an average volumetric error of b1%. The approach outlined in this study - image-based calibration of depth-retrieval models - significantly improves spaceborne supraglacial bathymetry retrievals, which are completely independent from in situ measurements.

Spectrally-based depth-retrieval models↗

Congruence of Clusters Defined By Whole Genome Sequencing and MALDI-TOF for Bacteria Isolated From Cleanrooms

Introduction: Oligotrophic conditions can render cleanrooms inhospitable to microbes. Despite these constraints, fungi and bacteria are frequently isolated from surfaces in astromaterials cleanrooms at the Johnson Space Center. Bacillus species are of particular concern because endospores belonging to this genus are resilient and can affect astromaterials. Current monitoring programs rely on 16S rRNA sequencing and the VITEK2 Compact system. These methods have limited power to resolve Bacillus species. Matrix-assisted laser desorption - time of flight mass spectrometry (MALDI-TOF MS), provides a rapid, low cost, method of identifying bacterial isolates and has a higher resolution than 16S rRNA sequencing, particularly for Bacillus species; however, few studies have compared this method to the industry gold standard, whole genome sequencing (WGS). Methods: Based on 16S rRNA classification, we selected 14 isolates for analysis with MALDI-TOF and WGS. Mass spectra were generated with MALDI-TOF MS and processed with custom scripts to identify clusters of closely related isolates and calculate a matrix of pairwise cosine similarity scores. Hybrid Illumina and Nanopore sequencing were used to generate draft genomes. Pairwise similarity scores were calculated from these genomes based on the average amino acid identity (AAI) predicted from single copy core genes. Congruence of clustering between these methods, was assessed by calculating adjusted Rand and Wallace coefficients. Results: Clusters of species generated from MALDI-TOF MS showed good agreement of phylotypes generated with WGS. Pairs of strains that were > 94% similar to each other in terms of predicted amino acid sequences consistently showed cosine similarities of mass spectra > 0.65 and, of the 9 clusters identified with WGS, 8 were identical with MALDI-TOF. This corresponds to an adjusted Rand index of 0.95 and a 95% confidence interval of 0.80 – 1.00 for adjusted Wallace coefficients. The only discordance was for a pair of isolates that were classified as Paenibacillus species. This pair showed relatively high similarity (0.84) in terms of MALDI-TOF MS but only 85% similarity in terms of AAI. Conclusion: This study shows that MALDI-TOF and WGS exhibit a similar ability to delineate Bacillus species isolated from cleanrooms and taxonomic units described by these two methods are consistent with one another. Since MALDI-TOF MS is low in cost and high in throughput, this approach appears to be an ideal option for routine microbial monitoring and identifying Bacillus species.

Farnaz Mazhari↗

The Athena Mars Rover Science Payload

The Mars Surveyor missions that will be launched in April of 2001 will include a highly capable rover that is a successor to the Mars Pathfinder mission's Sojourner rover. The design goals for this rover are a total traverse distance of at least 10 km and a total lifetime of at least one Earth year. The rover's job will be to explore a site in Mars' ancient terrain, searching for materials likely to preserve a record of ancient martian water, climate, and possibly biology. The rover will collect rock and soil samples, and will store them for return to Earth by a subsequent Mars Surveyor mission in 2005. The Athena Mars rover science payload is the suite of scientific instruments and sample collection tools that will be used to perform this job. The specific science objectives that NASA has identified for the '01 rover payload are to: (1) Provide color stereo imaging of martian surface environments, and remotely-sensed point discrimination of mineralogical composition. (2) Determine the elemental and mineralogical composition of martian surface materials. (3) Determine the fine-scale textural properties of these materials. (4) Collect and store samples. The Athena payload has been designed to meet these objectives. The focus of the design is on field operations: making sure the rover can locate, characterize, and collect scientifically important samples in a dusty, dirty, real-world environment. The topography, morphology, and mineralogy of the scene around the rover will be revealed by Pancam/Mini-TES, an integrated imager and IR spectrometer. Pancam views the surface around the rover in stereo and color. It uses two high-resolution cameras that are identical in most respects to the rover's navigation cameras. The detectors are low-power, low-mass active pixel sensors with on-chip 12-bit analog-to-digital conversion. Filters provide 8-12 color spectral bandpasses over the spectral region from 0.4 to 1.1 micron Narrow-angle optics provide an angular resolution of 0.28 mrad/pixel, nearly a factor of four higher than that of the Mars Pathfinder and Mars Surveyor '98 cameras. Image compression will be performed using a wavelet compression algorithm. The Mini-Thermal Emission Spectrometer (Mini-TES) is a point spectrometer operating in -the thermal IR. It produces high spectral resolution (5 /cm) image cubes with a wavelength range of 5-40 gm, a nominal signal/noise ratio of 500:1, and a maximum angular resolution of 7 mrad (7 cm at a distance of 10 in). The wavelength region over which it operates samples the diagnostic fundamental absorption features of rockforming minerals, and also provides some capability to see through dust coatings that could tend to obscure spectral features. The mineralogical information that Mini-TES provides will be used to select from a distance the rocks and soils that will be investigated in more detail and ultimately sampled. Mini-TES is derived from the MO/MGS TES instrument, but is significantly smaller and simpler. The instrument uses an 8-cm Cassegrain telescope, a Michelson interferometer, and uncooled pyroelectric detectors. Along with its mineralogical capabilities, Mini-TES can provide information on the thermophysical properties of rocks and soils. Viewing upward, it can also provide temperature profiles through the martian atmospheric boundary layer. Elemental and Mineralogical Composition: Once promising samples have been identified from a distance using Pancam/Mini-TES, they will be studied in detail using up to three compositional sensors that can be placed directly against them by an Instrument Arm. The two compositional sensors, presently on the payload are an Alpha-Proton-X-Ray Spectrometer (APXS), and a Mossbauer Spectrometer. The APXS is derived closely from the instrument that flew on Mars Pathfinder. Radioactive alpha sources and three detection modes (alpha, proton, and x-ray) provide elemental abundances of rocks and soils to complement and constrain mineralogical data. The Athena APXS will have a revised mechanical design that will cut down significantly on backscattering of alpha particles from martian atmospheric carbon. It will also include a target of known elemental composition that will be used for calibration purposes. The Athena Mossbauer Spectrometer is a diagnostic instrument for the mineralogy and oxidation state of Fe-bearing phases, which are particularly important on Mars. The instrument measures the resonant absorption of gamma rays produced by a Co-57 source to determine splitting of nuclear energy levels in Fe atoms that is related to the electronic environment surrounding them. It has been under development for space flight for many years at the Technical University of Darmstadt. The Mossbauer Spectrometer (and the other arm instruments) will be able to view a small permanent magnet array that will attract magnetic particles in the martian soil. The payload may also include a Raman Spectrometer. If included, the Raman Spectrometer will provide precise identification of major and minor mineral phases. It requires no sample preparation, and is also sensitive to organics. Fine-Scale Texture: The Instrument Arm a also carries a Microscopic Imager that will obtain high-resolution monochromatic images of the same materials for which compositional data will be obtained. Its spatial resolution is 20 micron/pixel over a 1 cm depth of field, and 40 micron/pixel over a 1-cm depth of field. Like Pancam, it uses the same active pixel sensor detectors and electronics as the rover's navigation cameras. The Instrument Arm is a three degree-of-freedom arm that uses designs and components from the Mars Pathfinder and Mars Surveyor '98 projects. Its primary function is instrument positioning. Along with the instruments noted above, it also carries a brush that can be used to remove dust and other loose coatings from rocks. Sample Collection and Storage: Martian rock and soil samples will be collected using a low-power rotary coring drill called the Mini-Corer. An important characteristic of this device is that it can obtain intact samples of rock from up to 5 cm within strong boulders and bedrock, Nominal core dimensions are 8xl7 mm. The Mini-Corer drills a core to the commanded depth in a rock, shears it off, retains it, and extracts it. It can also acquire samples of loose soil, using soil sample cups that are pressed downward into loose material. The Mini-Corer can drill at angles from vertical to 45' off vertical. It has six interchangeable bits for long life. Mechanical damage to the sample during drilling is minimal, and heating is negligible. After acquisition, the sample may be viewed by the arm instruments, and/or placed in one of 104 compartments in the Sample Container. A subset of the acquired samples may be replaced with other samples obtained later if desired. The Sample Container has no moving parts, and is mounted external to the rover for easy removal by the Mars Surveyor 2005 flight system. Operation of the rover will make extensive use of automated onboard navigation and hazard avoidance capabilities. Otherwise, use of onboard autonomy is minimal. Data downlink capability is about 40 Mbit/sol, and the use of the Mars Surveyor '01 orbiter for data relay imposes a limit of at most two command cycles per sol. Because of the significant amount of time available between command cycles, all payload elements will be operated sequentially, rather than in parallel.; this approach also significantly simplifies operations and minimizes peak power usage. The landing site for the '01 rover has not been selected yet. Site selection will make as full use as possible of Mars Global Surveyor data, and will involve substantial input from the broad Mars science community. Summary: The following table describes the mass, power, providers, and key scientific objectives of all the major elements of the Athena payload. Additional Athena payload information may be found at: http://astrosun.tn.cornell.edu/athena/index.html. Additional information contained in the original.

Squyes, S. W.↗

Observations of the gas stream in the mass transfer binary HR 2142 prime 1

The mass transfer binary system HR 2142 was observed at selected phases with the high resolution spectrograph on IUE. The observations were scheduled throughout the interval 0.91 phi 0.00 in order to allow viewing of the light of the primary star through the gas stream as it presents different orientations to the line of sight. Numerous UV lines formed in the gas stream were identified. The strengths and velocity variations displayed by these lines are compared with those observed in the ground based spectral region. As part of a preliminary analysis of the IUE data, column densities and velocities from Si III (4), Si IV (1), and Ti III (1) are used to deduce electron densities in the gas stream as well as its thickness. Possible evidence for stratification in the gas stream is presented.

Peters, G. J.↗

Pioneer Venus radar results - Altimetry and surface properties

A topographic map of 93% of the Venus globe was depicted by the radar altimeter of the Pioneer Venus orbiter with a resolution better than 150 km. Extremes in relief expressed as a center-of-mass-to-surface radius extend from 6049 to 6062 km; the elevated terrain is dominated by a massive equatorial area equal in size to South America. The distribution of average meter-scale surface slopes is determined for the same regions in the 1 to 10 deg range; elevated areas have higher slopes, so that most features observed in the earth-based images are also evident in the vertical-incidence spacecraft measurements.

Pettengill, G. H.↗

The energetic ion composition spectrometer /EICS/ for the Dynamics Explorer-A

The energetic ion composition spectrometer (EICS) on the DE-A spacecraft is a high sensitivity, high resolution (M/Delta M greater than 10 FWHM at focus) instrument. It covers the entire mass range from less than 1 amu/e to greater than 150 amu/e in 64 mass channels, at each of 32 energy per charge steps covering the range from 0 to approximately 17 keV/e. The measurements obtained from this instrument will be used primarily to investigate the coupling between the magnetosphere and the ionosphere via the auroral acceleration region. Additional uses of the data will be to investigate the ring current loss processes, the coupling of the dayside cusp particles to the magnetosheath, and the tracing of artificially injected ions.

Shelley, E. G.↗

Advanced techniques for plasma composition and dynamics measurements

The current state of knowledge regarding the space plasma is briefly considered. It is found that certain problems arise in connection with conventional measurements. In many cases, three-dimensional measurements are needed and a good time resolution. The present investigation has the objective to review developments related to energetic ion mass spectrometers which are capable of resolving some of the ambiguities. The employment of electrostatic analyzers (ESA) combined with velocity filters is considered, taking into account an instrument which combines a quadrispherical electrostatic analyzer with electromagnetic filters. Such an instrument is being developed for the Galileo Mission to Jupiter. In connection with an evaluation of developments concerning linear and two-dimensional mass spectrometers, attention is given to instruments which are capable of measuring several masses simultaneously. Instruments utilizing the time of flight technique of measuring mass are also examined.

Goldstein, R.↗

High Resolution Telescope and Spectrograph (HRTS)

The major objectives of the high resolution telescope and spectrograph (HRTS) are: (1) the investigation of the energy balance and mass balance of the temperature minimum, chromosphere, transition zone, and corona in quiet regions on the Sun as well as in plages, flares, and sunspots; (2) the investigation of the velocity field of the lower corona to study the origin of the solar wind; (3) the investigation of preflare and flare phenomena. The HRTS instruments consists of a telescope, an ultraviolet spectrograph, and ultraviolet spectroheliograph, and an H alpha slit display system, all housed in a thermal control canister mounted on an instrument pointing system.

Moore, R. L.↗

High Resolution Telescope and Spectrograph (HRTS)

The major objectives of the high resolution telescope and spectrograph (HRTS) are: (1) the investigation of the energy balance and mass balance of the temperature minimum, chromosphere, transition zone, and corona in quiet regions on the Sun as well as in plages, flares, and sunspots; (2) the investigation of the velocity field of the lower corona to study the origin of the solar wind; and (3) the investigation of preflare and flare phenomena. The HRTS instruments consists of a telescope, an ultraviolet spectrograph, an ultraviolet spectroheliograph, and an H alpha slit display system, all housed in a thermal control cannister mounted on an instrument pointing system.

Moore, R.↗

The Giotto dust impact detection system

The Giotto Dust Impact Detection System (DIDSY) consists of six independent subsystems to register the impact of all particulates of significant mass incident on the probe during the post-perihelion encounter with Comet Halley. Mounted on Giotto's front dust shield, the detectors will determine the mass spectrum of the dust, with a limiting sensitivity of 10 to the minus 17th power f, increasing to the largest grain masses encountered along Giotto's trajectory throught the cometary environment with an ultimate spatial resolution of 70 km. An additional detector is located on the rear shield to monitor dust particles that penetrate the from dust shield. An ambient plasma monitor measures the impact plasma generated by dust and gass impacts on the spacecraft.

Mcdonnell, J. A. M.↗

GRADIO three-axis electrostatic accelerometers

Dedicated accelerometers for satellite gravity gradiometry (GRADIO project) are described. The design profits from experience acquired with the CACTUS accelerometer payload of the satellite CASTOR-D5B and studies of highly accurate accelerometers for inertial navigation. The principle of operation, based on a three-axis electrostatic suspension of a cubic proof mass, is well suited for the measurements of accelerations less than 0.0001 m/sec/sec. A resolution better than 10 to the minus 11th power m/sec/sec/sq root Hz is expected.

Bernard, A.↗

In situ measurements of thermospheric composition, temperature, and winds by mass spectrometry

Mass spectrometry, in which a beam of electrons ionizes a sample of atmospheric gas and then analyses the ions thus produced to determine the concentration of each species in the sample, is presently evaluated as a basis for the study of earth atmosphere and other planetary atmospheres' properties. Recent applications of in situ mass spectrometry have measured thermospheric neutral gas composition, temperatures, and winds, with a spatial resolution sufficiently high to reveal previously unsuspected atmospheric variability. It is expected that analyses of these data will lead to a more detailed understanding of the deposition processes governing the thermosphere's highly variable structure.

Spencer, N. W.↗