Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Low temperature detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

An intense soft high-latitude X-ray source H2156-304 - A new BL Lacertae object

The discovery of an intense high-latitude soft X-ray source (designated H2156-304) detected with the low-energy detectors of the HEAO A-2 experiment is reported. The error box of the source includes a 14th mag starlike object that may be coincident with the radio source PKS 2155-304 and has been suggested as a BL Lac candidate. Intensity variations of H2156-304 on time scales of about 1 sec to 1 day are discussed, along with a probable flare from the source. The derived energy spectrum of the source is shown to be well fitted by either a two-temperature thermal model with temperatures of 16 million and 1.6 million K or a single power-law model with a spectral index of 2.4 + or - 0.3. Hydrogen column densities of approximately 2.5 x 10 to the 20th and 2.0 x 10 to the 20th H atoms/sq cm are obtained for the two-temperature and power-law models, respectively. The emission mechanism of H2156-304 is considered, and the characteristics of this source are compared with those of three known soft X-ray-emitting BL Lac objects.

Agrawal, P. C.↗

A 100 micro Kelvin bolometer system for SIRTF

Progress toward a prototype of 100 mK bolometric detection system for the Space Infrared Telescope Facility (SIRTF) is described. Two adiabatic demagnetization refrigerators (ADR's) were constructed and used to investigate the capabilities necessary for orbital operation. The first, a laboratory ADR, demonstrated a hold time at 0.1 K of over 12 hours, with temperature stability approx. 3 micro-K RMS achieved by controlling the magnetic field. A durable salt pill and an efficient support system have been demonstrated. A second ADR, the SIRTF flight prototype, has been built and will be flown on a balloon. Techniques for magnetic shielding, low heat leak current leads, and a mechanical heat switch are being developed in this ADR. Plans for construction of 100 mK bolometers are discussed. Three important cosmological investigations which will be carried out by these longest wavelength SIRTF detectors are described.

Bernstein, G. M.↗

X-ray imaging and electron temperature evolution in laser-driven magnetic reconnection experiments at the national ignition facility

We present results from x-ray imaging of high-aspect-ratio magnetic reconnection experiments driven at the National Ignition Facility. Two parallel, self-magnetized, elongated laser-driven plumes are produced by tiling 40 laser beams. A magnetic reconnection layer is formed by the collision of the plumes. A gated x-ray framing pinhole camera with micro-channel plate detector produces multiple images through various filters of the formation and evolution of both the plumes and current sheet. As the diagnostic integrates plasma self-emission along the line of sight, two-dimensional electron temperature maps ⟨Te⟩Y are constructed by taking the ratio of intensity of these images obtained with different filters. The plumes have a characteristic temperature ⟨Te⟩Y=240 ± 20 eV at 2 ns after the initial laser irradiation and exhibit a slow cooling up to 4 ns. The reconnection layer forms at 3 ns with a temperature ⟨Te⟩Y=280 ± 50 eV as the result of the collision of the plumes. The error bars of the plumes and current sheet temperatures separate at 4 ns, showing the heating of the current sheet from colder inflows. Using a semi-analytical model, we survey various heating mechanisms in the current sheet. We find that reconnection energy conversion would dominate at low density (ne≲7×1018 cm−3) and electron-ion collisional drag at high-density (≳1019 cm−3).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-channel front-end ASIC for a 3D position-sensitive detector

Arrays of 3D position-sensitive detectors (3DPSD), operating at room temperature and using cadmium zinc telluride (CZT) and thallium bromide (TIBr) sensors, are suitable for gamma-ray spectrometry in many applications. One detector configuration, the 3D position-sensitive Virtual Frisch-Grid detector (VFG), is particularly advantageous for integrating into large area arrays. The signals generated inside each detector of the array are captured with the anode, cathode and four pads that enable the reconstruction of the position and energy of the ionizing interaction by measurements of amplitude and timing of the signals. For these applications, a low-noise front-end ASIC has been developed, capable of processing bipolar signals (needed because of AC-coupling of certain electrodes). The ASIC can be coupled to an ADC in order to form a compound “waveform digitizer” capable of post-processing the analog signals and determining amplitude and timing information. This paper describes a 32-channel front-end ASIC that is suitable for reading out a 3 × 3 or 4 × 4 element matrix in the VFG configuration. Each channel is composed of a low-noise charge amplifier with an adaptive continuous reset feedback circuit suitable for both positive and negative charge, a first order shaper and a single-to-differential converter output stage. Voltage and current references are all internally generated by 10-bit DACs and the chip is fully controllable with the I 2 C communication protocol. The readout channel response has been verified using the implemented injection circuit. Linear behavior up to ~75 ke ± with the gain of ~80 mV/fC, and up to ~200 ke ± with the gain of ~30 mV/fC was demonstrated. In conclusion, the first test result waveforms using a 137 Cs radioactive source on a 5 × 5 × 12 mm 3 TIBr crystal are reported.

47 OTHER INSTRUMENTATION↗

Design and assembling status of the Mu2e electromagnetic calorimeter mechanical structures

The muon-to-electron conversion (Mu2e) experiment at Fermilab will search for the Charged Lepton Flavour Violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of physics beyond the Standard Model. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1348 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named disks ) positioned at the relative distance of 70 cm, downstream the aluminum target along the muon beamline, satisfies the Mu2e physics requirements. The hostile Mu2e operational conditions, in terms of radiation levels (total ionizing dose of 12 krad and a neutron fluence of 5 10^{10} n/cm2 @ 1 MeVeq (Si)/y), magnetic field intensity (1 T) and vacuum level (10−4 Torr) have posed tight constraints on the design of the detector mechanical structures and materials choice. The support structure of the two 674 crystal matrices employs two aluminum hollow rings and parts made of open- cell vacuum-compatible carbon fiber. The photosensors and service front-end electronics for each crystal are assembled in a unique mechanical unit inserted in a machined copper holder. The 674 units are supported by a machined plate made of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal con- tact with the copper holders. The data acquisition electronics is hosted in aluminum custom crates positioned on the external lateral surface of the two disks. The crates also integrate the electronics cooling system. In this poster we will review the constraints on the calorimeter mechanical structures, the technological choices, and the status of assembling at Fermilab.

Pasciuto, D.↗

H 1504 + 65 - An extraordinarily hot compact star devoid of hydrogen and helium

The optical identification of the bright soft X-ray source H 1504 + 65, originally discovered by the HEAO I A-2 low energy detectors, is reported. The optical counterpart exhibits a steep, virtually featureless continuum from optical wavelengths through the ultraviolet. The spectrum is remarkably featureless except for a broad O VI adsorption feature at 3494.7 A and C IV absorption at 3934 A and emission at 4658 A. The soft X-ray data, which are not consistent with any published models for degenerate stars having predominantly H or He compositions, suggest that H 1504 + 65 is a metal-rich, near-degenerate object of very high temperature. Qualitative considerations indicate that it is definitely hotter than PG 1159 - 035 and similar objects. A temperature of roughly 160,000 K is suggested.

Nousek, J. A.↗

Thermal Infrared Spectral Imager for Airborne Science Applications

An airborne thermal hyperspectral imager is under development which utilizes the compact Dyson optical configuration and quantum well infrared photo detector (QWIP) focal plane array. The Dyson configuration uses a single monolithic prism-like grating design which allows for a high throughput instrument (F/1.6) with minimal ghosting, stray-light and large swath width. The configuration has the potential to be the optimal imaging spectroscopy solution for lighter-than-air (LTA) vehicles and unmanned aerial vehicles (UAV) due to its small form factor and relatively low power requirements. The planned instrument specifications are discussed as well as design trade-offs. Calibration testing results (noise equivalent temperature difference, spectral linearity and spectral bandwidth) and laboratory emissivity plots from samples are shown using an operational testbed unit which has similar specifications as the final airborne system. Field testing of the testbed unit was performed to acquire plots of apparent emissivity for various known standard minerals (such as quartz). A comparison is made using data from the ASTER spectral library.

QWIP↗

Charge Trap Analysis in a SENSEI Skipper-CCD: Understanding Low-Energy Backgrounds in Rare-Event Searches

Skipper Charge-Coupled Devices (Skipper-CCDs) are ultra-low-threshold detectors capable of detecting energy deposits in silicon at the eV scale. Increasingly used in rare-event searches, one of the major challenges in these experiments is mitigating low-energy backgrounds. In this work, we present results on trap characterization in a silicon Skipper-CCD produced in the same fabrication run as the SENSEI experiment at SNOLAB. Lattice defects contribute to backgrounds in rare-event searches through single-electron charge trapping. To investigate this, we employ the charge-pumping technique at different temperatures to identify dipoles produced by traps in the CCD channel. We fully characterize a fraction of these traps and use this information to extrapolate their contribution to the single-electron background in SENSEI. We find that this subpopulation of traps does not contribute significantly but more work is needed to assess the impact of the traps that can not be characterized.

Brusco, Agustin [Buenos Aires U.]↗

Development, construction and qualification tests of the mechanical structures of the electromagnetic calorimeter of the Mu2e experiment at Fermilab

The “muon-to-electron conversion” (Mu2e) experiment at Fermilab will search for the Charged Lepton Flavour Violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of physics beyond the Standard Model. Mu2e detectors comprise a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter provides excellent electron identification, complementary information to aid pattern recognition and track reconstruction, and a fast calorimetric online trigger. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1340 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named “disks”) positioned at the relative distance of 70 cm downstream the aluminum target along the muon beamline satisfies the Mu2e physics requirements.The hostile Mu2e operational conditions, in terms of radiation levels (total ionizing dose of 12 krad and a neutron fluence of 5x1010 n/cm2 @ 1 MeVeq (Si)/y), magnetic field intensity (1 T) and vacuum level (10$^{-4}$ Torr) have posed tight constraints on the design of the detector mechanical structures and materials choice. The support structure of the two 670 crystal matrices employs two aluminum hollow rings and parts made of open-cell vacuum-compatible carbon fiber. The photosensors and service front-end electronics for each crystal are assembled in a unique mechanical unit inserted in a machined copper holder. The 670 units are supported by a machined plate made of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal contact with the copper holders to constitute a low resistance thermal bridge. The data acquisition electronics is hosted in aluminum custom crates positioned on the external lateral surface of the two disks. The crates also integrate the electronics cooling system as lines running in parallel to the front-end system.The constraints on the calorimeter mechanical structures design, the development from the conceptual design to the specifications of all the structural components, the status of components production and the components quality assurance tests are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of a Chemiluminescence Detector for the Measurement of Total Oxides of Nitrogen and Ammonia in the Atmosphere

By means of the thermal conversion of nitrogen dioxide to the nitric oxide, the chemiluminescent nitric oxide monitor, based on the nitric oxide plus ozone reaction, may be used for monitoring nitrogen dioxide plus nitric oxide (NO(x)). Under conditions previously described, ammonia is also converted to nitric oxide and therefore interferes. A metal surface, gold wool or stainless steel, operated at two different temperatures has been used to convert only nitrogen dioxide or nitrogen dioxide plus ammonia. Quantitative conversion of nitrogen dioxide to nitric oxide has been obtained at temperatures as low as 200 C. Conversion of ammonia is effected at temperatures of 300 C or higher. By the addition of a converter the basic nitric oxide monitor may be used for measuring NO(x) or NO(x) plus ammonia. As an alternate mode, for a fixed high temperature, a specific scrubber is described for removing NH3 without affecting NO2 concentrations.

Hodgeson, J. A.↗

Development of Position-Sensitive Magnetic Calorimeters for X-Ray Astronomy

Metallic magnetic calorimeters (MMC) are one of the most promising devices to provide very high energy resolution needed for future astronomical x-ray spectroscopy. MMC detectors can be built to large detector arrays having thousands of pixels. Position-sensitive magnetic (PoSM) microcalorimeters consist of multiple absorbers thermally coupled to one magnetic micro calorimeter. Each absorber element has a different thermal coupling to the MMC, resulting in a distribution of different pulse shapes and enabling position discrimination between the absorber elements. PoSMs therefore achieve the large focal plane area with fewer number of readout channels without compromising spatial sampling. Excellent performance of PoSMs was achieved by optimizing the designs of key parameters such as the thermal conductance among the absorbers, magnetic sensor, and heat sink, as well as the absorber heat capacities. Micro fab ri - cation techniques were developed to construct four-absorber PoSMs, in which each absorber consists of a two-layer composite of bismuth and gold. The energy resolution (FWHM full width at half maximum) was measured to be better than 5 eV at 6 keV x-rays for all four absorbers. Position determination was demonstrated with pulse-shape discrimination, as well as with pulse rise time. X-ray microcalorimeters are usually designed to thermalize as quickly as possible to avoid degradation in energy resolution from position dependence to the pulse shapes. Each pixel consists of an absorber and a temperature sensor, both decoupled from the cold bath through a weak thermal link. Each pixel requires a separate readout channel; for instance, with a SQUID (superconducting quantum interference device). For future astronomy missions where thousands to millions of resolution elements are required, having an individual SQUID readout channel for each pixel becomes difficult. One route to attaining these goals is a position-sensitive detector in which a large continuous or pixilated array of x-ray absorbers shares fewer numbers of temperature sensors. A means of discriminating the signals from different absorber positions, however, needs to be built into the device for each sensor. The design concept for the device is such that the shape of the temperature pulse with time depends on the location of the absorber. This inherent position sensitivity of the signal is then analyzed to determine the location of the event precisely, effectively yielding one device with many sub-pixels. With such devices, the total number of electronic channels required to read out a given number of pixels is significantly reduced. PoSMs were developed that consist of four discrete absorbers connected to a single magnetic sensor. The design concept can be extended to more than four absorbers per sensor. The thermal conductance between the sensor and each absorber is different by design and consequently, the pulse shapes are different depending upon which absorber the xrays are received, allowing position discrimination. A magnetic sensor was used in which a paramagnetic Au:Er temperature-sensitive material is located in a weak magnetic field. Deposition of energy from an x-ray photon causes an increase in temperature, which leads to a change of magnetization of the paramagnetic sensor, which is subsequently read out using a low noise dc-SQUID. The PoSM microcalorimeters are fully microfabricated: the Au:Er sensor is located above the meander, with a thin insulation gap in between. For this position-sensitive device, four electroplated absorbers are thermally linked to the sensor via heat links of different thermal conductance. One pixel is identical to that of a single-pixel design, consisting of an overhanging absorber fabricated directly on top of the sensor. It is therefore very strongly thermally coupled to it. The three other absorbers are supported directly on a silicon-nitride membrane. These absorbers are thermally coupled to the sensor via Ti (5 nm)/Au250 nm) metal links. The strength of the links is parameterized by the number of gold squares making up the link. For detector performance, experimentally different pulse-shapes were demonstrated with 6 keV x-rays, which clearly show different rise times for different absorber positions. For energy resolution measurement, the PoSM was operated at 32 mK with an applied field that was generated using a persistent current of 50 mA. Over the four pixels, energy resolution ranges from 4.4 to 4.7 eV were demonstrated.

Bandler, SImon↗

Design and implementation of a J -coupled spectrometer for multidimensional structure and relaxation detection at low magnetic fields

In recent years, it has been realized that low and ultra-low field (mT-nT magnetic field range) nuclear magnetic resonance (NMR) spectroscopy can be used for molecular structural analysis. However, spectra are often hindered by lengthy acquisition times or require large sample volumes and high concentrations. Here, we report a low field (50 µT) instrument that employs a linear actuator to shuttle samples between a 1 T prepolarization field and a solenoid detector in a laboratory setting. The current experimental setup is benchmarked using water and 13 C-methanol with a single scan detection limit of 2x10 20 spins (3 μL, 55 M H 2 O) and detection of 2.9x10 19 (200 μL, 617 mM 13 C-methanol) spins with signal averaging. The system has a dynamic range of >3 orders of magnitude. Investigations of room-temperature relaxation dynamics of 13Cmethanol show that sample dilution can be used in lieu of sample heating to acquire spectra with linewidths comparable to high-temperature spectra. These results indicate that the T 1 and T 2 mechanisms are governed by both the proton exchange rate and the dissolved oxygen in the sample. Finally, a 2D correlation spectroscopy (COSY) experiment is reported, performed in the strong coupling regime that resolves the multiple resonances associated with the heteronuclear Jcoupling. The spectrum was collected using 10 times less sample and in less than half the time from previous reports in the strong coupling limit.

47 OTHER INSTRUMENTATION↗

Investigation of defects in melt and solution grown perovskite CsPbBr 3 single crystals

Recently, there has been considerable interest in x-ray and gamma ray detectors with large volume and high energy resolution that operate at room temperature. To improve detector energy resolution, the carrier mobility-lifetime product needs to be increased, and the electronic trap state concentration needs to be minimized. Defect concentrations in the part per billion range can alter the charge transport and carrier recombination lifetime. In this work, thermally stimulated current spectroscopy measurements were systematically carried out in bulk halide perovskite single crystals of CsPbBr 3 over a temperature range of 80–320 K. The origins and trap parameters of CsPbBr 3 crystals from the solution growth and melt growth procedures were determined and compared. Trap concentrations were ranged from 1 × 10 11 to 1 × 10 16 cm –3 . Appreciable detector performance was observed for CsPbBr3 crystals with trap concentrations less than 1 × 10 14 cm –3 . The comparison of spectral responses of crystal samples grown using two different methods shows that, after purification, solution-grown crystals are comparable to melt-grown crystals in terms of low defect concentration and improved detector performance. Finally, for an improved mobility-lifetime product and enhanced spectral response to high energy radiation from fissile materials, trap states in either type of a crystal ingot must be reduced closer to 10 11 cm –3 .

36 MATERIALS SCIENCE↗

Low energy X-ray emission from five galaxy cluster sources

We report the detection of soft (0.2-2.5 keV) X-ray emission from several known cluster X-ray sources using the low energy detectors of the HEAO 1 A-2 experiment. Soft X-ray emission was observed from five clusters - the Centaurus cluster, Abell 2147, SC 1329-314, Abell 2319, and Abell 133. Spectral parameters estimated from the soft X-ray fluxes are inconsistent with those reported at higher energies for the Centaurus cluster, Abell 2147, and SC 1329-314, indicating the presence of more than one spectral component in these clusters. No evidence for more than one component was found for either Abell 2319 or Abell 133. The temperature of Abell 133 is constrained to be less than 2 x 10 to the 7th K, making it the coolest X-ray cluster yet detected.

Reichert, G.↗

A Low-Power Time-to-Digital Converter for the CMS Endcap Timing Layer (ETL) Upgrade

We present the design and test results of a Time-to-Digital-Converter (TDC). The TDC will be a part of the readout ASIC, called ETROC, to read out Low-Gain Avalanche Detectors (LGADs) for the CMS Endcap Timing Layer (ETL) of High-Luminosity LHC upgrade. One of the challenges of the ETROC design is that the TDC is required to consume less than 200 W for each pixel at the nominal hit occupancy of 1%. To meet the low-power requirement, we use a single delay line for both the Time of Arrival (TOA) and the Time over Threshold (TOT) measurements without delay control. A double-strobe self-calibration scheme is used to compensate for process variation, temperature, and power supply voltage. The TDC is fabricated in a 65 nm CMOS technology. The overall performances of the TDC have been evaluated. The TOA has a bin size of 17.8 ps within its effective dynamic range of 11.6 ns. The effective measurement precision of the TOA is 5.6 ps and 9.9 ps with and without the nonlinearity correction, respectively. The TDC block consumes 97 W at the hit occupancy of 1%. Over a temperature range from 23 C to 78 C and a power supply voltage range from 1.05 V to 1.35 V (the nominal value of 1.20 V), the self-calibrated bin size of the TOA varies within 0.4%. The measured TDC performances meet the requirements except that more tests will be performed in the future to verify that the TDC complies with the radiation-tolerance specifications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-High Vacuum Outgassing Characterization of Thermally Processed Low-Carbon Steel for Advanced Particle Accelerator and Gravitational Wave Detector Applications

This dissertation investigated AISI 1020 low-carbon steel as an alternative vacuum chamber material to conventional stainless steel for ultra-high vacuum (UHV) and extreme-high vacuum (XHV) applications. After a 400 °C/48 h bake, AISI 1020 tube chambers achieved a hydrogen outgassing rate of 2.4 × 10¿¹6 Torr·L·s¿¹·cm¿², approximately 2,300 times lower than the prebaked 316L stainless-steel comparator, among the lowest hydrogen outgassing rates ever reported for an uncoated metallic vacuum chamber. Bare and magnetite-coated AISI 1020 chambers were then compared using throughput and rate-of-rise methods. The magnetite coating yielded 5× lower water outgassing at room temperature, but this advantage disappeared after 80 °C baking. After full thermal conditioning (400 °C/48 h prebake followed by 150 °C/96 h and 200 °C/110 h), bare steel achieved 25× lower hydrogen outgassing than the magnetite-coated chamber (9.6 × 10¿¹6 Torr·L·s¿¹·cm¿²) and >99% H2 purity with carbon species below RGA detection. Monte Carlo molecular flow simulations of a CEBAF photogun beamline (96 scenarios) showed that replacing 304L stainless steel with AISI 1020 reduces equilibrium H2 pressure by a factor of 833; a single 304L electrode contributes 98.8% of the gas load despite occupying only 9.1% of the internal surface area. A 500-m Einstein Telescope beampipe screening showed that corrugated bellows contribute 18% of the gas load from only 0.7% of the surface area. A five-model adsorption isotherm framework applied to 22 pumpdown datasets (164 fits with AR(1)-GLS correction) established that the experimental protocol, not the material, controls isotherm identifiability: Dubinin–Radushkevich wins isothermal pipe pumpdowns; Langmuir wins thermally dominated chamber bakes. Cross-dataset joint fitting of the AISI 1020 pipe pumpdowns yielded an H2 diffusion activation energy Ed = 7.24 ± 1.28 kcal·mol¿¹, consistent with trap dominated diffusion in commercial low-carbon steels. Two companion innovations were developed: a Variable Conductance Device (VCD, patent pending IDF-00723) for XHV outgassing measurement, and VacuumDesignerPro (VDP), a MATLAB-based design tool validated against LIGO benchmarks.

Al-Allaq, Aiman H [Old Dominion University]↗

Tuning microwave losses in superconducting resonators

Abstract The performance of superconducting resonators, particularly cavities for particle accelerators and micro cavities and thin film resonators for quantum computations and photon detectors, has been improved substantially by recent material treatments and technological advances. As a result, the niobium cavities have reached the quality factors Q ∼ 10 11 at 1–2 GHz and 1.5 K and the breakdown radio-frequency (rf) fields H close to the dc superheating field of the Meissner state. These advances raise the questions of whether the state-of-the-art cavities are close to the fundamental limits, what these limits actually are, and to what extent the Q and H limits can be pushed by the materials nano structuring and impurity management. These issues are also relevant for many applications using high-Q thin film resonators, including single-photon detectors and quantum circuits. This topical review outlines basic physical mechanisms of the rf nonlinear surface impedance controlled by quasiparticles, dielectric losses and trapped vortices, as well as the dynamic field limit of the Meissner state. Sections cover methods of engineering an optimum quasiparticle density of states and superfluid density to reduce rf losses and kinetic inductance by pairbreaking mechanisms related to magnetic impurities, rf currents, and proximity-coupled metallic layers at the surface. A section focuses on mechanisms of residual surface resistance, which dominates rf losses at ultra low temperatures. Microwave losses of trapped vortices and their reduction by optimizing the concentration of impurities and pinning potential are also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Deep diode arrays for X-ray detection

Temperature gradient zone melting process was used to form p-n junctions in bulk of high purity silicon wafers. These diodes were patterned to form arrays for X-ray spectrometers. The whole fabrication processes for these X-ray detectors are reviewed in detail. The p-n junctions were evaluated by (1) the dark diode I-V measurements, (2) the diode C sub I - V measurements, and (3) the MOS C-V measurements. The results showed that these junctions were linearly graded in charge distribution with low reverse bias leakage current flowing through them (few nA at -10 volts). The X-ray detection experiments showed that an FWHM of 500 eV was obtained from these diodes with a small bias of just -5 volts (for X-ray source Fe55). A theoretical model was proposed to explain the extra peaks found in the energy spectra and a very interesting point - cross talk effect was pointed out. This might be a solution to the problem of making really high resolution X-ray spectrometers.

Zemel, J. N.↗