Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Low Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

SoLAr: Solar Neutrinos in Liquid Argon

SoLAr is a new concept for a liquid-argon neutrino detector technology to extend the sensitivities of these devices to the MeV energy range - expanding the physics reach of these next-generation detectors to include solar neutrinos. We propose this novel concept to significantly improve the precision on solar neutrino mixing parameters and to observe the "hep branch" of the proton-proton fusion chain. The SoLAr detector will achieve flavour-tagging of solar neutrinos in liquid argon. The SoLAr technology will be based on the concept of monolithic light-charge pixel-based readout which addresses the main requirements for such a detector: a low energy threshold with excellent energy resolution (approximately 7%) and background rejection through pulse-shape discrimination. The SoLAr concept is also timely as a possible technology choice for the DUNE "Module of Opportunity", which could serve as a next-generation multi-purpose observatory for neutrinos from the MeV to the GeV range. The goal of SoLAr is to observe solar neutrinos in a 10 ton-scale detector and to demonstrate that the required background suppression and energy resolution can be achieved. SoLAr will pave the way for a precise measurement of the 8-B flux, an improved precision on solar neutrino mixing parameters, and ultimately lead to the first observation of hep neutrinos in the DUNE Module of Opportunity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recoil imaging for dark matter, neutrinos, and physics beyond the Standard Model

Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detectors. This white paper outlines the physics case for recoil imaging, and puts forward a decadal plan to advance towards the directional detection of low-energy recoils with sensitivity and resolution close to fundamental performance limits. The science case covered includes: the discovery of dark matter into the neutrino fog, directional detection of sub-MeV solar neutrinos, the precision study of coherent-elastic neutrino-nucleus scattering, the detection of solar axions, the measurement of the Migdal effect, X-ray polarimetry, and several other applied physics goals. We also outline the R&D programs necessary to test concepts that are crucial to advance detector performance towards their fundamental limit: single primary electron sensitivity with full 3D spatial resolution at the $\sim$100 micron-scale. These advancements include: the use of negative ion drift, electron counting with high-definition electronic readout, time projection chambers with optical readout, and the possibility for nuclear recoil tracking in high-density gases such as argon. We also discuss the readout and electronics systems needed to scale-up such detectors to the ton-scale and beyond.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Strong NIR II Chiroptical Response and Magnetic Anisotropy via Modular Installation of Chiral Capping Ligands on a Light-Emitting Diradicaloid Scaffold

Low-energy molecular lumiphores have seen increased interest due to potential imaging and communications applications. Specifically, molecules that emit in the near-infrared (NIR, 700–1700 nm) or telecom (∼1260–1625 nm) regions, where attenuation is minimized in biological tissue and optical fibers, respectively, can drastically improve image resolution and depth penetration; however, bright low-energy emission is rare due to exponentially decreasing quantum yields in this region. Chiral molecules exhibiting strong NIR or telecom absorption/emission would be of particular interest due to advanced security and spintronics applications, but these compounds remain scarce and are currently restricted to lanthanide or nanoparticle-based systems. Here, we report the synthesis of a chiral organic-based NIR emitter, enabled by simple peripheral installation of chiral capping ligands. These ligands twist the achiral NIR-emissive core, breaking inversion symmetry. Furthermore, this twisting enables strong chiroptical responses observed via static and transient circular dichroism and increased magnetic anisotropy through electron paramagnetic resonance (EPR) measurements, establishing this strategy as a promising method for the development of new chiral emitters and sensors.

Electron paramagnetic resonance spectroscopy↗

2D perovskite-based high spatial resolution X-ray detectors

Abstract X-ray radiography is the most widely used imaging technique with applications encompassing medical and industrial imaging, homeland security, and materials research. Although a significant amount of research and development has gone into improving the spatial resolution of the current state-of-the-art indirect X-ray detectors, it is still limited by the detector thickness and microcolumnar structure quality. This paper demonstrates high spatial resolution X-ray imaging with solution-processable two-dimensional hybrid perovskite single-crystal scintillators grown inside microcapillary channels as small as 20 µm. These highly scalable non-hygroscopic detectors demonstrate excellent spatial resolution similar to the direct X-ray detectors. X-ray imaging results of a camera constructed using this scintillator show Modulation Transfer Function values significantly better than the current state-of-the-art X-ray detectors. These structured detectors open up a new era of low-cost large-area ultrahigh spatial resolution high frame rate X-ray imaging with numerous applications.

2D perovskite↗

SOFIA: Spectrometer Optimized for Facility Integrated Applications

Los Alamos National Laboratory researchers developed the Spectrometer Optimized for Facility Integrated Applications (SOFIA) for new capabilities in non-destructive nuclear material analysis, nuclear data measurements, and actinide science. SOFIA is the first ultra-high resolution gamma spectrometer technology based on low-temperature microcalorimeter designs. By precisely measuring the gamma rays passively emitted from radioactive and nuclear materials, SOFIA provides rapid, completely nondestructive analysis to improve the economics and timeliness of nuclear material analysis by reducing reliance on costly sampling and destructive analysis. By developing the first compact instrument based on ultrahigh resolution microcalorimeter gamma spectroscopy, the researchers intended to bring this technology into practical use in nuclear facilities and analytical laboratories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two 28-nm front-end ASICs for ultra-fine spatial resolution and precision timing to be 3D integrated with 12 LGADs

The 3DIntSenS Collaboration—a joint effort between SLAC, Fermilab, and LLNL—is developing enabling technologies for next-generation radiation imaging detectors that combine ultra-fine spatial resolution (about 10 µm) with precision timing (<20 ps), while maintaining low power <1 W/cm2 and high data throughput. The approach leverages 3D integration between advanced CMOS readout ASICs and finely pixelated LGAD sensors to achieve the performance and scalability required for large-area, high-rate applications. High-granularity, precision-timing detectors are essential for scientific advances in HEP, NP, BES, and FES, but widespread adoption is limited by the cost and complexity of 3D integration. To close this gap, the collaboration is developing LGAD sensors compatible with 12-inch commercial CMOS processes, enabling cost-effective integration with high-performance ASICs under development. We present two 28 nm CMOS ASIC prototypes, including a low-jitter front end, and in-pixel TDC demonstrating sub-10 ps timing resolution. These advances represent a critical step toward scalable, high-resolution radiation imaging systems for future scientific instrumentation.

England, Troy [Fermilab] (ORCID:0000000154405255)↗

Two 28-nm front-end ASICs for ultra-fine spatial resolution and precision timing to be 3D integrated with 12 LGADs

The 3DIntSenS Collaboration—a joint effort between SLAC, Fermilab, and LLNL—is developing enabling technologies for next-generation radiation imaging detectors that combine ultra-fine spatial resolution (about 10 µm) with precision timing (<20 ps), while maintaining low power <1 W/cm2 and high data throughput. The approach leverages 3D integration between advanced CMOS readout ASICs and finely pixelated LGAD sensors to achieve the performance and scalability required for large-area, high-rate applications. High-granularity, precision-timing detectors are essential for scientific advances in HEP, NP, BES, and FES, but widespread adoption is limited by the cost and complexity of 3D integration. To close this gap, the collaboration is developing LGAD sensors compatible with 12-inch commercial CMOS processes, enabling cost-effective integration with high-performance ASICs under development. We present two 28 nm CMOS ASIC prototypes, including a low-jitter front end, and in-pixel TDC demonstrating sub-10 ps timing resolution. These advances represent a critical step toward scalable, high-resolution radiation imaging systems for future scientific instrumentation.

England, Troy [Fermilab] (ORCID:0000000154405255)↗

Atomic resolution scanning transmission electron microscopy at liquid helium temperatures for quantum materials

Fundamental quantum phenomena in condensed matter, ranging from correlated electron systems to quantum information processors, manifest their emergent characteristics and behaviors predominantly at low temperatures. This necessitates the use of liquid helium (LHe) cooling for experimental observation. Atomic resolution scanning transmission electron microscopy combined with LHe cooling (cryo-STEM) provides a powerful characterization technique to probe local atomic structural modulations and their coupling with charge, spin and orbital degrees-of-freedom in quantum materials. However, achieving atomic resolution in cryo-STEM is exceptionally challenging, primarily due to sample drifts arising from temperature changes and noises associated with LHe bubbling, turbulent gas flow, etc. In this work, we demonstrate atomic resolution cryo-STEM imaging at LHe temperatures using a commercial side-entry LHe cooling holder. Firstly, we examine STEM imaging performance as a function of He gas flow rate, identifying two primary noise sources: He-gas pulsing and He-gas bubbling. Secondly, we propose two strategies to achieve low noise conditions for atomic resolution STEM imaging: either by temporarily suppressing He gas flow rate using the needle valve or by acquiring images during the natural warming process. Lastly, we show the applications of image acquisition methods and image processing techniques in investigating structural phase transitions in Cr 2 Ge 2 Te 6 , CuIr 2 S 4 , and CrCl 3 . In conclusion, our findings represent an advance in the field of atomic resolution electron microscopy imaging for quantum materials and devices at LHe temperatures, which can be applied to other commercial side-entry LHe cooling TEM holders.

36 MATERIALS SCIENCE↗

Accelerating Scientific Simulations with Bi-Fidelity Weighted Transfer Learning

High-fidelity modeling is an essential design tool for many engineering applications. However, for complex systems, computational cost can be a limiting factor. Analyzing parameter sensitivity, uncertainty quantification, and design optimization require many model evaluations. Surrogate models are often used to develop the relationship between model parameters and quantities of interest. However, in the case of complex systems, surrogate models require several degrees of freedom and, thus, a large number of data points to determine the correct dependencies. For many applications, this may be prohibitively expensive. The reduction of computational requirements can be achieved by leveraging low-fidelity models. Low-fidelity models represent the system at a coarser resolution with the advantage of computational efficiency. Therefore, a bi-fidelity modeling paradigm, which augments the accuracy of a low-fidelity model in a computationally efficient manner by invoking limited runs of a high-fidelity model, can be leveraged to sufficiently balance the accuracy and computational requirements. In this work, a bi-fidelity weighted transfer learning method using neural networks was applied to a computational fluid dynamics heat transfer modeling problem. The transfer learning advantage was investigated as a function of hyperparameters. Our main finding is that the use of a bi-fidelity modeling paradigm achieves accuracy close to that of a high-fidelity Gaussian process model while significantly reducing computational cost. The bi-fidelity model achieves comparable performance with 90 high-fidelity samples-that is, 60% less than the samples needed to achieve similar accuracy without the use of bi-fidelity modeling,

Borowiec, Katarzyna↗

Calibration of a versatile multi-energy soft x-ray diagnostic for WEST long pulse plasmas

A compact multi-energy soft x-ray diagnostic is being installed on the W Environment in Steady-state Tokamak (WEST), which was designed and built to test ITER-like tungsten plasma facing components in a long pulse (~1000 s) scenario. The diagnostic consists of a pinhole camera fielded with the PILATUS3 photon-counting Si-based detector (≲100 kpixel). The detector has sensitivity in the range 1.6–30 keV and enables energy discrimination, providing a higher energy resolution than conventional systems with metal foils and diodes with adequate space and time resolution (≲1 cm and 2 ms). The lower-absorption cut-off energy is set independently on each one of the ~100 kpixels, providing a unique opportunity to measure simultaneously the plasma emissivity in multiple energy ranges and deduce a variety of plasma parameters (e.g., T e , n Z , and ΔZ eff ). The energy dependence of each pixel is calibrated here over the range 3–22 keV. The detector is exposed to a variety of monochromatic sources—fluorescence emission from metallic targets—and for each pixel, the lower energy threshold is scanned to calibrate the energy dependence. The data are fit to a responsivity curve (“S-curve”) that determines the mapping between the possible detector settings and the energy response for each pixel. Here, the calibration is performed for three energy ranges: low (2.3–6 keV), medium (4.5–13.5 keV), and high (5.4–21 keV). We determine the achievable energy resolutions for the low, medium, and high energy ranges as 330 eV, 640 eV, and 950 eV, respectively. The main limitation for the energy resolution is found to be the finite width of the S-curve.

47 OTHER INSTRUMENTATION↗

Strong Correspondence in Evapotranspiration and Carbon Dioxide Fluxes Between Different Eddy Covariance Systems Enables Quantification of Landscape Heterogeneity in Dryland Fluxes

Abstract The eddy covariance method is widely used to investigate fluxes of energy, water, and carbon dioxide at landscape scales, providing important information on how ecological systems function. Flux measurements quantify ecosystem responses to environmental perturbations and management strategies, including nature‐based climate‐change mitigation measures. However, due to the high cost of conventional instrumentation, most eddy covariance studies employ a single system, limiting spatial representation to the flux footprint. Insufficient replication may be limiting our understanding of ecosystem behavior. To address this limitation, we deployed eight lower‐cost eddy covariance systems in two clusters around two conventional eddy covariance systems in the Chihuahuan Desert of North America for a period of 2 years. These dryland settings characterized by large temperature variations and relatively low carbon dioxide fluxes represented a challenging setting for eddy covariance. We found very good closure of energy and water balance across all systems (within ±9% of unity). We found very good correspondence between the lower‐cost and conventional systems' fluxes of sensible heat (with concordance correlation coefficient (CCC) of ≥0.87), latent energy (evapotranspiration; CCC ≥ 0.89), and useful correspondence in the net ecosystem exchange ((NEE); with CCC ≥ 0.4) at the daily temporal resolution. Relative to the conventional systems, the low‐frequency systems were characterized by a higher level of random error, particularly in the NEE fluxes. Lower‐cost systems can enable wider deployment affording better replication and sampling of spatiotemporal variability at the expense of greater measurement noise that might be limiting for certain applications. Replicated eddy covariance observations may be useful when addressing gaps in the existing monitoring of critical and underrepresented ecosystems and for measuring areas larger than a single flux footprint.

54 ENVIRONMENTAL SCIENCES↗

Cryogen-free modular scanning tunneling microscope operating at 4-K in high magnetic field on a compact ultra-high vacuum platform

One of the daunting challenges in modern low temperature scanning tunneling microscopy (STM) is the difficulty of combining atomic resolution with cryogen-free cooling. Further functionality needs, such as ultra-high vacuum (UHV), high magnetic field (HF), and compatibility with μm-sized samples, pose additional challenges to an already ambitious build. We present the design, construction, and performance of a cryogen-free, UHV, low temperature, and high magnetic field system for modular STM operation. An internal vibration isolator reduces vibrations in this system, allowing for atomic resolution STM imaging while maintaining a low base temperature of ∼4 K and magnetic fields up to 9 T. Samples and tips can be conditioned in situ utilizing a heating stage, an ion sputtering gun, an e-beam evaporator, a tip treater, and sample exfoliation. In situ sample and tip exchange and alignment are performed in a connected UHV room temperature stage with optical access. Multisite operation without breaking vacuum is enabled by a unique quick-connect STM head design. A novel low-profile vertical transfer mechanism permits transferring the STM between room temperature and the low temperature cryostat.

Instruments & Instrumentation↗

Solubility controls on plutonium and americium release in subsurface environments exposed to acidic processing wastes

To identify the role of waste composition and sediment interactions in controlling Pu and Am mobility in contaminated sediments at Hanford, a legacy nuclear site, Pu and Am concentrations in solutions equilibrated with contaminated sediments from beneath the 216-Z-9 (Z-9) Trench were compared to the solubilities of PuO 2 materials, synthesized by methods representative of the disposed wastes, in the absence of sediments. Furthermore, this work shows that the solubilities of PuO 2 materials synthesized by different methods, and with varying particle sizes, agree with PuO 2 (am,hyd), although dissolution kinetics differed between materials. According to saturation index (SI) calculations, PuO 2 (am,hyd) is likely also controlling Pu release from sediments under conditions where phosphate concentrations are low. However, both Pu-phosphate and Am-phosphate phases, identified in SI calculations and by high resolution transmission electron microscopy, play roles in controlling release in low pH, high phosphate, shallow sediments just below the Z-9 Trench. The elevated phosphate is likely due to decomposition of tributyl phosphate from waste solutions over time. Sediments from deeper in the subsurface beneath the Z-9 Trench are less acidic and contain less phosphate, with Pu solubility likely controlled by PuO 2 (am,hyd) that precipitated following neutralization of the acidic waste stream. Controls on Am concentrations in deeper sediments are more complex and potentially involve sediment adsorption and/or release from Pu (1-x) Am x O 2 following Am in-growth. The concentrations of both Pu and Am were elevated in the colloidal fraction associated with shallow sediments, but not in PuO 2 experiments, suggesting the presence of Pu/Am pseudocolloids (e.g., Pu/Am associated with mineral colloids). However, Pu and Am association with the colloidal size fraction was not observed in deeper sediments, suggesting transport of Pu and Am to these depths beneath the Z-9 Trench was not due to colloidal transport.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Effects of Molecular Size on Resolution in Charge Detection Mass Spectrometry

Instrumental resolution of Fourier transform-charge detection mass spectrometry instruments with electrostatic ion trap detection of individual ions depends on the precision with which ion energy is determined. Energy can be selected using ion optic filters or from harmonic amplitude ratios (HARs) that provide Fellgett’s advantage and eliminate the necessity of ion transmission loss to improve resolution. Unlike the ion energy-filtering method, the resolution of the HAR method increases with charge (improved S/N) and thus with mass. An analysis of the HAR method with current instrumentation indicates that higher resolution can be obtained with the HAR method than the best resolution demonstrated for instruments with energy-selective optics for ions in the low MDa range and above. However, this gain is typically unrealized because the resolution obtainable with molecular systems in this mass range is limited by sample heterogeneity. Here, this phenomenon is illustrated with both tobacco mosaic virus (0.6–2.7 MDa) and AAV9 (3.7–4.7 MDa) samples where mass spectral resolution is limited by the sample, including salt adducts, and not by instrument resolution. Nevertheless, the ratio of full to empty AAV9 capsids and the included genome mass can be accurately obtained in a few minutes from 1× PBS buffer solution and an elution buffer containing 300+ mM nonvolatile content despite extensive adduction and lower resolution. Empty and full capsids adduct similarly indicating that salts encrust the complexes during late stages of droplet evaporation and that mass shifts can be calibrated in order to obtain accurate analyte masses even from highly salty solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparing Thermal Neutron Scintillators for Use With SiPM-Readout Detectors

Scintillator-based thermal neutron detectors for scientific scattering facilities offer an effective combination of large-area coverage and good spatial resolution. At Oak Ridge National Laboratory, silicon photomultiplier (SiPM)-readout Anger cameras using 6 Li glass scintillators have been developed, but the spatial resolution of these detectors is limited by the relatively low light yield of the glass. Recently, several brighter scintillator compositions with sufficient 6 Li concentration have emerged as promising candidates for higher-resolution imaging. Here, in this work, we evaluate five scintillator materials: GS20, LiF/ZnS:Ag, LiF/ZnO:Zn, LiI:Eu, and Cs 2 LiYCl 6 :Ce, each mounted on a SiPM Anger camera. For each scintillator, the neutron detection efficiency, spatial resolution, and count rate capabilities were measured and compared. Each of the new compositions achieved a spatial resolution better than 0.5 mm, compared to 0.66 mm for GS20, with LiI:Eu reaching the best value of 0.32 mm. Although these compositions improve the spatial resolution of the Anger camera, their longer pulse decay times limit their use in high count rate applications, and the camera’s hardware must be optimized for the different properties of the new scintillators.

Neutron detectors↗

Results for pixel and strip centimeter-scale AC-LGAD sensors with a 120 GeV proton beam

Here, we present the results of an extensive evaluation of strip and pixel AC-LGAD sensors tested with a 120 GeV proton beam, focusing on the influence of design parameters on the sensor temporal and spatial resolutions. Results show that reducing the thickness of pixel sensors significantly enhances their time resolution, with 20-μm-thick sensors achieving around 20 ps. Uniform performance is attainable with optimized n + sheet resistance, making these sensors ideal for future timing detectors. Conversely, 20-μm-thick strip sensors exhibit higher jitter than similar pixel sensors, negatively impacting time resolution, despite reduced Landau fluctuations with respect to the 50-μm-thick versions. Additionally, it is observed that a low resistivity in strip sensors limits signal size and time resolution, whereas higher resistivity improves performance. This study highlights the importance of tuning the n+ sheet resistance and suggests that further improvements should target specific applications like the Electron–Ion Collider or other future collider experiments. In addition, the detailed performance of four AC-LGADs sensor designs is reported as examples of possible candidates for specific detector applications. These advancements position AC-LGADs as promising candidates for future 4D tracking systems, pending the development of specialized readout electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of Pixel and Strip AC-LGAD Sensors with Different Design Parameter on a 120 GeV Proton Beam

We present the results of an extensive evaluation of strip and pixel AC-LGAD sensors tested with a 120 GeV proton beam, focusing on the influence of design parameters on the sensor temporal and spatial resolutions. Results show that reducing the thickness of pixel sensors significantly enhances their time resolution, with 20- μm-thick sensors achieving around 20 ps. Uniform performance is attainable with optimized sheet resistance, making these sensors ideal for future timing detectors. Conversely, 20-μm-thick strip sensors exhibit higher jitter than similar pixel sensors, negatively impacting time resolution, despite reduced Landau fluctuations with respect to the 50-μm-thick versions. Additionally, it is observed that a low resistivity in strip sensors limits signal size and time resolution, whereas higher resistivity improves performance. This study highlights the importance of tuning the n+ sheet resistance and suggests that further improvements should target specific applications like the Electron-Ion Collider or other future collider experiments. In addition, the detailed performance of four AC-LGADs sensor designs is reported as examples of possible candidates for specific detector applications. These advancements position AC-LGADs as promising candidates for future 4D tracking systems, pending the development of specialized readout electronics.

Lara, Carlos Pérez↗