Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Irradiation Experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Report on INL Activities for Uncertainty Reduction Analysis of FY11

This report presents the status of activities performed at INL under the ARC Work Package on "Uncertainty Reduction Analyses" that has a main goal the reduction of uncertainties associated with nuclear data on neutronic integral parameters of interest for the design of advanced fast reactors under consideration by the ARC program. First, an analysis of experiments was carried out. For both JOYO (the first Japanese fast reactor) and ZPPR-9 (a large size zero power plutonium fueled experiment performed at ANL-W in Idaho) the performance of ENDF/B-VII.0 is quite satisfying except for the sodium void configurations of ZPPR-9, but for which one has to take into account the approximation of the modeling. In fact, when one uses a more detailed model (calculations performed at ANL in a companion WP) more reasonable results are obtained. A large effort was devoted to the analysis of the irradiation experiments, PROFIL-1 and -2 and TRAPU, performed at the French fast reactor PHENIX. For these experiments a pre-release of the ENDF/B-VII.1 cross section files was also used, in order to provide validation feedback to the CSWEG nuclear data evaluation community. In the PROFIL experiments improvements can be observed for the ENDF/B-VII.1 capture data in 238 Pu, 241 Am, 244 Cm, 97 Mo, 151 Sm, 153 Eu, and for 240 Pu(n,2n). On the other hand, 240,242 Pu, 95 Mo, 133 Cs and 145 Nd capture C/E results are worse. For the major actinides 235 U and especially 239 Pu capture C/E's are underestimated. For fission products, 105,106 Pd, 143,144 Nd and 147,149 Sm are significantly underestimated, while 101 Ru and 151 Sm are overestimated. Other C/E deviations from unity are within the combined experimental and calculated statistical uncertainty. From the TRAPU analysis, the major improvement is in the predicted 243 Cm build-up, presumably due to an improved 242 Cm capture evaluation. The COSMO experiment was also analyzed in order to provide useful feedback on fission cross sections. It was found out that ENDF/B-VII.1 238,240 Pu fission cross sections have improved with respect to VII.0 files while 242 Pu's fission cross section has not.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advanced Fuel/Cladding Testing Capabilities in the ORNL High Flux Isotope Reactor

The ability to test advanced fuels and cladding materials under reactor operating conditions in the United States is limited. The Oak Ridge National Laboratory (ORNL) High Flux Isotope Reactor (HFIR) and the newly expanded post-irradiation examination (PIE) capability at the ORNL Irradiated Fuels Examination Laboratory provide unique support for this type of advanced fuel/cladding development effort. The wide breadth of ORNL's fuels and materials research divisions provides all the necessary fuel development capabilities in one location. At ORNL, facilities are available from test fuel fabrication, to irradiation in HFIR under either thermal or fast reactor conditions, to a complete suite of PIEs, and to final product disposal. There are very few locations in the world where this full range of capabilities exists. New testing capabilities at HFIR have been developed that allow testing of advanced nuclear fuels and cladding materials under prototypic operating conditions (i.e., for both fast-spectrum conditions and light-water-reactor conditions). This paper will describe the HFIR testing capabilities, the new advanced fuel/cladding testing facilities, and the initial cooperative irradiation experiment that begins this year.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental and Computational Study of the Flux Spectrum in Materials Irradiation Facilities of the High Flux Isotope Reactor

This report compares the available experimental neutron flux data in the High Flux Isotope Reactor (HFIR) to computational models of the HFIR loosely based on the experimental loading of cycle 400. Over the last several decades, many materials irradiation experiments have included fluence monitors which were subsequently used to reconstruct a coarse-group energy-dependent flux spectrum. Experimental values for thermal and fast neutron flux in the flux trap about the midplane are found to be 1.78 0.27 and 1.05 0:06 1E15 n/cm sec, respectively. The reactor physics code MCNP is used to calculate neutron flux in the HFIR at irradiation locations. The computational results are shown to correspond to closely to experimental data for thermal and fast neutron flux with calculated percent differences ranging from 0:55 13.20%.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Production of Precursor Materials for the Development of Iron-Based Superconductor (IBS) Wire

The objective of the activities under this Annex is to address the extrinsic Jc limitations uncovered in pioneering work. In order to engineer the defects pinning landscape charged particle irradiations experiments on bulk samples, different doping and chemical additions will be performed at different National facilities (Test Beam Facility at Fermilab; Linac Isotope Producer at Brookhaven National Laboratory; Integrated Biology Laboratory at University of Wisconsin-Madison; Facility for Rare Isotope Beams at Michigan State University). The samples will be produced at ENEA by different techniques. Magnetization and advanced microscopy measures will be performed at Fermilab. After irradiation, depending on the level of radioactivity, the samples will be tested at Fermilab or where it is possible to measure radioactive materials as University of Wisconsin-Madison.

43 PARTICLE ACCELERATORS↗

Production of Precursor Materials for the Development of Iron-Based Superconductor (IBS) Wire

The objective of the activities under this Annex is to address the extrinsic Jc limitations uncovered in pioneering work. In order to engineer the defects pinning landscape charged particle irradiations experiments on bulk samples with different doping and chemical additions will be performed at different National facilities (Test Beam Facility at Fermilab; Linac Isotope Producer at Brookhaven National Laboratory; Integrated Biology Laboratory at University of Wisconsin-Madison; Facility for Rare Isotope Beams at Michigan State University). The samples will be produced at TUAT by different synthesis techniques. Magnetization and advanced microscopy measures will be performed at Fermilab. After irradiation, depending on the level of radioactivity, the samples will be tested at Fermilab or where it is possible to measure radioactive materials as University of Wisconsin-Madison. In parallel, the precursor materials produced by TUAT will be used for IBS-wire fabrication at Fermi

43 PARTICLE ACCELERATORS↗

Computational Transport Modeling of High-Energy Neutrons Found in the Space Environment

The high charge and high energy (HZE) particle radiation environment in space interacts with spacecraft materials and the human body to create a population of neutrons encompassing a broad kinetic energy spectrum. As an HZE ion penetrates matter, there is an increasing chance of fragmentation as penetration depth increases. When an ion fragments, secondary neutrons are released with velocities up to that of the primary ion, giving some neutrons very long penetration ranges. These secondary neutrons have a high relative biological effectiveness, are difficult to effectively shield, and can cause more biological damage than the primary ions in some scenarios. Ground-based irradiation experiments that simulate the space radiation environment must account for this spectrum of neutrons. Using the Particle and Heavy Ion Transport Code System (PHITS), it is possible to simulate a neutron environment that is characteristic of that found in spaceflight. Considering neutron dosimetry, the focus lies on the broad spectrum of recoil protons that are produced in biological targets. In a biological target, dose at a certain penetration depth is primarily dependent upon recoil proton tracks. The PHITS code can be used to simulate a broad-energy neutron spectrum traversing biological targets, and it account for the recoil particle population. This project focuses on modeling a neutron beamline irradiation scenario for determining dose at increasing depth in water targets. Energy-deposition events and particle fluence can be simulated by establishing cross-sectional scoring routines at different depths in a target. This type of model is useful for correlating theoretical data with actual beamline radiobiology experiments. Other work exposed human fibroblast cells to a high-energy neutron source to study micronuclei induction in cells at increasing depth behind water shielding. Those findings provide supporting data describing dose vs. depth across a water-equivalent medium. This poster presents PHITS data suggesting an increase in dose, up to roughly 10 cm depth, followed by a continual decrease as neutrons come to a stop in the target.

Cox, Brad↗

Comparison of fission product release predictions using PARFUME with results from the AGR-1 safety tests

Safety tests were conducted on fuel compacts from AGR-1, the first irradiation experiment of the Advanced Gas Reactor (AGR) Fuel Development and Qualification program, at temperatures ranging from 1600 to 1800 °C to determine fission product release at temperatures that bound reactor accident conditions. The PARFUME (PARticle FUel ModEl) code was used to predict the release of fission products silver, cesium, strontium, and krypton from fuel compacts containing tristructural isotropic (TRISO) coated particles during 15 of these safety tests. Comparisons between PARFUME predictions and post-irradiation examination results of the safety tests were conducted on two types of AGR-1 compacts: compacts containing only intact particles and compacts containing one or more particles whose SiC layers failed during safety testing. In both cases, PARFUME globally over-predicted the experimental release fractions by several orders of magnitude: more than three (intact) and two (failed SiC) orders of magnitude for silver, more than three and up to two orders of magnitude for strontium, and up to two and more than one orders of magnitude for krypton. The release of cesium from intact particles was also largely over-predicted (by up to five orders of magnitude) but its release from particles with failed SiC was only over-predicted by a factor of about 3. These over-predictions can be largely attributed to an over-estimation of the diffusivities used in the modeling of fission product transport in TRISO-coated particles. The integral release nature of the data makes it difficult to estimate the individual over-estimations in the kernel or each coating layer. Nevertheless, a tentative assessment of correction factors to these diffusivities was performed to enable a better match between the modeling predictions and the safety testing results. The method could only be successfully applied to silver and cesium. In the case of strontium, correction factors could not be assessed because potential release during the safety tests could not be distinguished from matrix content released during irradiation. Furthermore, in the case of krypton, all the coating layers are partly retentive and the available data did not allow the level of retention in individual layers to be determined, hence preventing derivation of any correction factors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AFIP-6 Characterization Summary Report

The AFIP-6 (ATR Full-size-plate In center flux trap Position) Characterization Summary Report outlines the fresh fuel characterization efforts performed during the AFIP-6 experiment. The AFIP-6 experiment was designed to evaluate the performance of monolithic uranium-molybdenum (U-Mo) fuels at a scale prototypic of Advanced Test Reactor (ATR) fuel plates (45-inches long). The AFIP-6 test was the first test with plates that were swaged into the rails of the assembly. This test served to examine the effects of a plate in a swaged condition with longer fuel zones (22.5-inches long), that were centered in the plate. AFIP-6 test plates employed a zirconium interlayer that was co-rolled with the fuel foil. Previous mini-plate and AFIP irradiation experiments performed in ATR have demonstrated the stable behavior of the interface between the U-Mo fuel and the zirconium interlayer.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Versatile Test Reactor Conceptual Core Design

The VTR is a 300-MW(thermal) sodium-cooled fast reactor (SFR) designed for the specific purpose of delivering unique testing capabilities to enable the advancement of all reactor technologies. With its flux level, irradiation volume, and operational flexibility, the VTR will enable accelerated testing of materials, fuels, and various components needing irradiation testing. Proven SFR technologies and design approaches have been leveraged in designing the VTR core, ensuring the highest possible readiness level. This resulted in the VTR using ternary metallic fuel and delivering fast flux levels in excess of 4 x 10 15 n/cm 2 ∙ s over large useful volumes, corresponding to about 60 dpa/year in steel. As part of the design efforts, the VTR core performance has been determined for a representative configuration, ensuring that the reactivity control systems offer sufficient shutdown margins, that the core can be safely cooled in all situations, and that reactivity feedback coefficients are conducive to a favorable safety behavior. Furthermore, the incorporation of features such as fuel assembly storage in the shield region supports the flexible and reliable operation of the VTR. Additional design work has been ongoing as well. This includes thorough shielding performance evaluations to ensure safe operation of the VTR, verification and validation of the design tools used to achieve compliance with Nuclear Quality Assurance (NQA-1) requirements, early assessment of the impact of irradiation experiments on the core performance envelope and associated margins, and in-depth uncertainty quantification efforts to quantify the anticipated range of performance characteristics. An experimental program supporting the VTR core design has been set up, with the current focus being on thermal-hydraulic experiments. The purpose of this experimental program is to obtain confirmatory measurements to serve directly as part of the core design basis or as part of the validation cases supporting the simulation tools used.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Carbon Ion Irradiation of the Rat Spinal Cord: Dependence of the Relative Biological Effectiveness on Linear Energy Transfer

Purpose: To measure the relative biological effectiveness (RBE) of carbon ions in the rat spinal cord as a function of linear energy transfer (LET). Methods and Materials: As an extension of a previous study, the cervical spinal cord of rats was irradiated with single doses of carbon ions at 6 positions of a 6-cm spread-out Bragg peak (16-99 keV/μm). The TD{sub 50} values (dose at 50% complication probability) were determined according to dose-response curves for the development of paresis grade 2 within an observation time of 300 days. The RBEs were calculated using TD{sub 50} for photons of our previous study. Results: Minimum latency time was found to be dose-dependent, but not significantly LET-dependent. The TD{sub 50} values for the onset of paresis grade 2 within 300 days were 19.5 ± 0.4 Gy (16 keV/μm), 18.4 ± 0.4 Gy (21 keV/μm), 17.7 ± 0.3 Gy (36 keV/μm), 16.1 ± 1.2 Gy (45 keV/μm), 14.6 ± 0.5 Gy (66 keV/μm), and 14.8 ± 0.5 Gy (99 keV/μm). The corresponding RBEs increased from 1.26 ± 0.05 (16 keV/μm) up to 1.68 ± 0.08 at 66 keV/μm. Unexpectedly, the RBE at 99 keV/μm was comparable to that at 66 keV/μm. Conclusions: The data suggest a linear relation between RBE and LET at high doses for late effects in the spinal cord. Together with additional data from ongoing fractionated irradiation experiments, these data will provide an extended database to systematically benchmark RBE models for further improvements of carbon ion treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Recent Advances on Carrier and Exciton Self-Trapping in Strontium Titanate: Understanding the Luminescence Emissions

An up-to-date review on recent results for self-trapping of free electrons and holes, as well as excitons, in strontium titanate (STO), which gives rise to small polarons and self-trapped excitons (STEs) is presented. Special attention is paid to the role of carrier and exciton self-trapping on the luminescence emissions under a variety of excitation sources with special emphasis on experiments with laser pulses and energetic ion-beams. In spite of the extensive research effort, a definitive identification of such localized states, as well as a suitable understanding of their operative light emission mechanisms, has remained lacking or controversial. However, promising advances have been recently achieved and are the objective of the present review. In particular, significant theoretical advances in the understanding of electron and hole self-trapping are discussed. Also, relevant experimental advances in the kinetics of light emission associated with electron-hole recombination have been obtained through time-resolved experiments using picosecond (ps) laser pulses. The luminescence emission mechanisms and the light decay processes from the self-trapped excitons are also reviewed. Recent results suggest that the blue emission at 2.8 eV, often associated with oxygen vacancies, is related to a transition from unbound conduction levels to the ground singlet state of the STE. The stabilization of small electron polarons by oxygen vacancies and its connection with luminescence emission are discussed in detail. Through ion-beam irradiation experiments, it has recently been established that the electrons associated with the vacancy constitute electron polaron states (Ti 3+ ) trapped in the close vicinity of the empty oxygen sites. These experimental results have allowed for the optical identification of the oxygen vacancy center through a red luminescence emission centered at 2.0 eV. Ab-initio calculations have provided strong support for those experimental findings. Finally, the use of Cr-doped STO has offered a way to monitor the interplay between the chromium centers and oxygen vacancies as trapping sites for the electron and hole partners resulting from the electronic excitation.

36 MATERIALS SCIENCE↗

Automated Internal Energy Calibration by OnTheFly for AGR-5/6/7

The software program, OnTheFly, was developed at Idaho National Laboratory (INL) to keep high-purity germanium (HPGe) detectors energy calibrated during very long experiments. Over time, spectra produced from a HPGe detector will slowly stretch or contract, causing the energy calibration to change. If the energy calibration changes too much, it will cause energy lines to be misidentified. The higher the energy line the more affected they are by this change. OnTheFly tracks and adjusts the slowly changing energy calibrations so the energy lines will not be misidentified. OnTheFly was used with the Fission Product Monitoring System (FPMS) during the AGR-5/6/7 irradiation experiment performed at INL’s Advanced Test Reactor (ATR). Five HPGe detectors were used to monitor the five capsules in AGR-5/6/7. There were also two extra HPGe detectors that were maintained as spares. Before each ATR cycle of the experiment, the HPGe detectors were energy calibrated with a thorium radioactive source. During each ATR cycle, each detector would acquire data for 8 hours and then reset and acquire data for another 8 hours. After each 8-hour run, the spectra would be saved and analyzed autonomously. The results were then read by OnTheFly and used to produce a new energy calibration for each detector. The new energy calibrations were compared to the current energy calibrations and, if certain criteria were met, the new energy calibration would replace the current energy calibration. The new energy calibration would be used for future spectra. OnTheFly was run at least every couple of days but could be run as much as after each 8-hour run. OnTheFly kept the spectra energy calibrated during the ATR cycles over the 2 years and 5 months that the AGR-5/6/7 experiment ran.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison of fission product release predictions using PARFUME with results from the AGR-1 safety tests

Safety tests were conducted on fourteen fuel compacts from AGR-1, the first irradiation experiment of the Advanced Gas Reactor (AGR) Fuel Development and Qualification program, at temperatures ranging from 1600 to 1800°C to determine fission product release at temperatures that bound reactor accident conditions. The PARFUME (PARticle FUel ModEl) code was used to predict the release of fission products silver, cesium, strontium, and krypton from fuel compacts containing tristructural isotropic (TRISO) coated particles during the safety tests, and the predicted values were compared with experimental results. Preliminary comparisons between PARFUME predictions and post-irradiation examination (PIE) results of the safety tests show different trends in the prediction of the fractional release depending on the species, and it leads to different conclusions regarding the diffusivities used in the modeling of fission product transport in TRISO-coated particles: • For silver, the diffusivity in silicon carbide (SiC) might be over-estimated by a factor of at least 102 to 103 at 1600°C and 1700°C, and at least 10 to 102 at 1800°C. The diffusivity of silver in uranium oxy-carbide (UCO) might also be over-estimated, but the available data are insufficient to allow definitive conclusions to be drawn. • For cesium, the diffusivity in UCO might be over-estimated by a factor of at least 102 to 103 at 1600°C, 105 at 1700°C, and 103 at 1800°C. The diffusivity of cesium in SiC might also over-estimated, by a factor of 10 at 1600°C and 103 at 1700°C, based upon the comparisons between calculated and measured release fractions from intact particles. There is no available estimate at 1800°C since all the compacts heated up at 1800°C contain particles with failed SiC layers whose release dominates the release from intact particles. • For strontium, the diffusivity in SiC might be over-estimated by a factor of 10 to 102 at 1600 and 1700°C, and 102 to 103 at 1800°C. These values might be somewhat over-estimated because the strontium retention during irradiation cannot be assessed a priori, which affects the magnitude of the calculated release during safety testing. The diffusivity of strontium in UCO cannot be derived from these heating tests, but it is assumed to be modeled correctly using the IAEA recommended value for kernel diffusivity. • For krypton, there is no reliable release data for compacts heated up at 1600°C, which includes all the compacts containing only intact particles. At 1700 and 1800°C, comparisons show an over-prediction of the release from compacts containing particles with failed SiC by 1 to 1.5 orders of magnitude. The available data from these heating tests do not allow to determine which of the TRISO-coating’s layers diffusivities are under or over-estimated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Irradiation Effects on Stability of δ-UZr2 phase in U-50 wt% Zr Alloy

U-50wt%Zr is a candidate metallic nuclear fuel with potential application in light water reactors due to its excellent thermal properties and high radiation tolerance. The Zr-rich UZr fuels possess greater swelling resistance and fission gas release characteristics compared with U-rich UZr fuels. In this current study, the δ-phase U-50wt%Zr is proton irradiated at room temperature to 1 displacement per atom (dpa) to provide insights on phase stability under irradiation conditions. High resolution characterization of Transmission Electron Microscopy (TEM) and Atom Probe Tomography (APT) characterization techniques are used to elucidate microstructural changes due to irradiation. TEM and APT results show highly oriented bcc β-Zr-rich platelet precipitates nucleating adjacent to α-U phases inside the UZr 2 matrix. Formation of this platelet morphology is characteristic of Widmänstatten structure which can be attributed to a variety of factors such as differences in thermal expansion coefficient between the phases, grain size, alloy composition, and cooling rate. The phases present are distinctly different than those observed through in situ annealing, but irradiation accelerates diffusion and phase separation kinetics. These microstructural changes in U-50wt%Zr are different from those achieved by pure thermodynamic or high temperature heavy ion irradiation experiments. Finally, our work, together with previous ones, highlight the necessity to study the U-Zr phase diagram under non-equilibrium thermodynamics conditions to support this material's deployment as a viable nuclear fuel form.

36 MATERIALS SCIENCE↗

Evolution of irradiation defects in Ti 2 AlC ceramics during heavy ion irradiation

Here, the evolution of irradiation defects in Ti 2 AlC under Kr ion irradiation at room and elevated temperatures has been investigated. The dependence of defect size and density on the irradiation dose and temperature was characterized by in-situ transmission electron microscopy (TEM) irradiation experiments. At 25-800 °C, interstitial-type dislocation loops with several nanometers in diameter form on the basal plane of Ti 2 AlC mostly with a Burgers vector of 1/2[0 0 0 1], and no voids have been observed. The number density of dislocation loops approaches saturation at a level of about 2 dpa at 800 °C. Ti 2 AlC samples remain crystalline in structure without amorphization or phase transformation. However, the localized disorder of atomic positions on the basal plane of the irradiated Ti 2 AlC was revealed by high-resolution transmission electron microscopy (HRTEM) studies, which increases with irradiation dose while decreases with elevated temperatures.

36 MATERIALS SCIENCE↗

Effects of temperature and dose rate on ion-irradiated γ-LiAlO 2 pellets

Defect accumulation and microstructural evolution during ion irradiation at elevated temperatures are governed by competing processes of defect production, driven by the dose rate, and defect recovery, controlled by diffusion, interaction, and annihilation. Here, this study investigates the effects of irradiation temperature and the dose rate on microstructural evolution, deuterium retention, and lithium volatilization in γ-LiAlO 2 pellets subjected to sequential He + and D + ion irradiation. Experiments were performed to a total fluence of 3 × 10 17 (He + + D + )/cm 2 at 623, 673, 723, and 773 K with an average He + dose rate of 7.7 × 10 −4 dpa/s, and to 2 × 10 17 (He + + D + )/cm 2 at 773 K with dose rates of 6.8 × 10 −5 , 2.9 × 10 −4 , and 7.3 × 10 −4 dpa/s. At 623 K, the microstructure was dominated by cavities and fractures with no observable precipitate formation, while small precipitates emerged at 673 K. Increasing the irradiation temperature to 723–773 K promoted the formation of larger, faceted LiAl 5 O 8 precipitates, and surface amorphization, accompanied by pronounced lithium depletion and H–D isotopic exchange. At 773 K, medium and high dose rates produced an amorphized surface layer over a crystalline subsurface containing LiAl 5 O 8 precipitates and blisters at the crystalline–amorphous interface, whereas low-dose-rate irradiation preserved surface crystallinity with cavities distributed in the matrix, around precipitates, and along grain boundaries. Precipitate morphology was anisotropic with limited size dependence on the dose rate. These results elucidate the coupled effects of temperature and the dose rate and demonstrate that sequential He + and D 2 + irradiation at 773 K reproduces key microstructural features and H isotope behavior observed in neutron-irradiated γ-LiAlO 2 at 573 K.

dose rate effects↗

Differential Radiosensitizing Potential of Temozolomide in MGMT Promoter Methylated Glioblastoma Multiforme Cell Lines

Purpose: To investigate the radiosensitizing potential of temozolomide (TMZ) for human glioblastoma multiforme (GBM) cell lines using single-dose and fractionated {gamma}-irradiation. Methods and Materials: Three genetically characterized human GBM cell lines (AMC-3046, VU-109, and VU-122) were exposed to various single (0-6 Gy) and daily fractionated doses (2 Gy per fraction) of {gamma}-irradiation. Repeated TMZ doses were given before and concurrent with irradiation treatment. Immediately plated clonogenic cell-survival curves were determined for both the single-dose and the fractionated irradiation experiments. To establish the net effect of clonogenic cell survival and cell proliferation, growth curves were determined, expressed as the number of surviving cells. Results: All three cell lines showed MGMT promoter methylation, lacked MGMT protein expression, and were sensitive to TMZ. The isotoxic TMZ concentrations used were in a clinically feasible range of 10 {mu}mol/L (AMC-3046), 3 {mu}mol/L (VU-109), and 2.5 {mu}mol/L (VU-122). Temozolomide was able to radiosensitize two cell lines (AMC 3046 and VU-122) using single-dose irradiation. A reduction in the number of surviving cells after treatment with the combination of TMZ and fractionated irradiation was seen in all three cell lines, but only AMC 3046 showed a radiosensitizing effect. Conclusions: This study on TMZ-sensitive GBM cell lines shows that TMZ can act as a radiosensitizer and is at least additive to {gamma}-irradiation. Enhancement of the radiation response by TMZ seems to be independent of the epigenetically silenced MGMT gen000.

62 RADIOLOGY AND NUCLEAR MEDICINE↗