Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Impact testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Some Observations About the Drop-weight Explosive Sensitivity Test

The apparent simplicity of the drop-weight apparatus for explosive sensitivity testing hides the reality that it is actually a complex integrated test of both ignition and growth of deflagration. Although the drop-weight test is undeniably a useful screening test for explosive properties, a misunderstanding of the technique’s limitations has blinded many researchers to its limited wider applicability. This monograph discusses how the test actually works, the significant engineering difficulties with standardization between machines, which types of explosives are suited to the test and which are not, and finally offers a few suggestions for alternatives when a more quantified understanding of a material’s response is required for other applications.

36 MATERIALS SCIENCE↗

Dynamic Wind Loading on CSP Collectors Caused by Turbulent Wind Fluctuations: Insights from a 2-Year Field Campaign

Concentrating Solar Power (CSP) is a promising solar technology for electricity generation with thermal energy storage and with the additional benefit of industrial heat production. Wind loading on CSP collector structures, such as parabolic troughs or heliostats, is one of the primary drivers of their structural design costs. In particular, dynamic wind loading is a major source of uncertainty in the collector design process, which heavily relies on wind tunnel testing. In the field, the turbulent nature of the incoming wind creates fluctuating loads (support structure loads and resulting mirror deflections) on the collectors, with impacts on fatigue lifetime and optical performance. As is well known, wind tunnel tests cannot entirely reproduce the complex turbulent wind conditions typically observed at full-scale plants. To shed light on this topic, NREL initiated a field campaign at the operational Nevada Solar One (NSO) powerplant that uses parabolic troughs as solar collectors. The aim of the project is a detailed characterization of prevailing wind and turbulence conditions and resulting operational loads on parabolic troughs. We use the published 2-year dataset of high-resolution combined wind and structural loads measurements [1] to characterize the dynamic structural wind response. For quantifying dynamic wind loading, we apply the concept of admittance functions, which are spectral transfer functions that couple the turbulent wind to resulting structural loads (aerodynamic admittance), and to the structural response (mechanical admittance). In practice, aerodynamic admittance describes which turbulent eddy sizes are effective in creating structural loads. The mechanical admittance describes in which frequency ranges these loads are reinforced or dampened by the structure. While these functions are an established concept in civil engineering, their recent application to a single full-scale heliostat [2] proved their broader applicability to CSP collectors. Here, we present a characterization of admittance functions for full-scale parabolic trough collectors and show how wind characteristics (mean wind speed and direction, turbulent kinetic energy, turbulent length scales), the sun-tracking trough angle, and row position alter the admittance functions. Further, we study to which extent the admittance functions are universal for a specific trough geometry and how our findings compare to reported heliostat results. References [1] https://data.openei.org/submissions/5938. [2] Blume, K., Roger, M., and Pitz-Paal, R. 2023b. "Simplified analytical model to describe wind loads and wind-induced tracking deviations of heliostats." Solar Energy, 256, 96-109. https://doi.org/10.1016/j.solener.2023.03.055.

admittance functions↗

Project No. 5: Evaluating Dredged Materials for Energy Storage Applications with Economic and Carbon Benefits (CRADA Final Report)

The New York Power Authority (NYPA) is committed to supporting the Climate Leadership and Community Protection Act (CLCPA) through its VISION2030 strategic plan. As a clean energy provider, NYPA is seeking to demonstrate leadership in every aspect of its business by taking a comprehensive approach to sustainability management and integrating sustainability principles into day-to-day decision-making. This effort includes planning for climate resilience through projects that mitigate climate risk in our operations and prioritize climate opportunities in our investments. Canal Corporation, a subsidiary of NYPA, is charged with maintaining minimum water depths for navigation in the Cayuga-Seneca, Champlain, Erie and Oswego Canals. In order to do so, an average volume of 280,000 cubic yards of sediment is dredged annually and held in Upland Disposal Sites (UDS) permitted by the New York Department of Environmental Conservation (NYSDEC). The required on-land storage at UDSes are nearing capacity, and disposal opportunities are costly, both economically and environmentally. Novel energy storage technology developed by NREL provides an opportunity for meeting NYPA's need to find reuse options for dredged materials and commitment to providing clean reliable energy. This would also support NYPA's goal of developing 300 MW of utility scale storage and enabling 150 MW of distributed storage by 2030. NREL will consult NYPA on the environmental and economic impact of reusing dredged materials as useful commodities such as energy storage media, construction sand or industrial uses. Test and material characterization methods will be based on current NREL storage material characterization approaches. NREL worked with NYPA on sample preparation, material testing, test results analysis. Test and material characterization methods were based on current NREL storage material characterization approaches. The team analyzed the environmental and economic impact of reusing dredged materials as useful commodities such as energy storage media, construction sand or industrial uses. The test and analysis works have achieved the project goal in characterizing NYPA dredging materials and verifying their various uses including construction sand and thermal energy storage media. Uses of dredging materials as useful materials will bring economic and environmental benefits and avoid disposal costs.

25 ENERGY STORAGE↗

Modeling and Analysis for Spent Nuclear Fuel Seismic Testing

Note: This is the final public release version of PNNL-31671 Draft, which was previously released to the sponsor for review. The intent is the public release version will be PNNL-31671. There are no significant changes from the earlier draft version. This unlimited distribution report is the deliverable for M3SF-21PN010202014: Modeling and Analysis for Spent Nuclear Fuel Seismic Testing. This report summarizes the modeling, analysis, and test plan support completed by Pacific Northwest National Laboratory for the spent nuclear fuel dry storage system seismic test plan through May of 2021. Test plan preparation is planned to continue until the seismic test is completed in July of 2022. This report covers preliminary structural dynamic model development and computer-aided design of test hardware. Based on preliminary modeling, the strongest earthquakes under consideration in this test program provide mechanical loading on the spent nuclear fuel that is comparable to the 30 cm cask drop scenario, although the loads do not appear to be strong enough to cause significant permanent deformation of the fuel assembly spacer grids. The potential for grid deformation during the test will be assessed when the proposed shake table motion becomes available. The weakest earthquakes considered in this test are expected to be comparable to the mechanical loads witnessed in the multimodal transportation test of 2017. The horizontal canister system is predicted to provide nearly-uniform loading condition on the fuel assemblies it contains, while the vertical cask system is predicted to cause non-uniform dynamic loads on the fuel assemblies. In the horizontal case, gravity keeps the fuel assemblies in contact with one basket wall surface unless the loads are strong enough to cause a separation. In the vertical case, the fuel assemblies are relatively long and slender, and seismic motion in the anticipated test range is predicted to cause the assemblies to lean, tilt, and impact the basket walls throughout the seismic event. These gap closures are a nonlinear force transmission condition, so the vertical system is expected to have more variation and variability than the horizontal system. While the horizontal system is expected to have a relatively more linear response than the vertical system, there is still the potential for nonlinear behavior in the horizontal system because the fuel assemblies are free to slide, bounce, and impact the basket walls if the seismic loads are strong enough. One major conclusion of this study is that the use of mixed fuel assemblies in the canister will be acceptable. There are differences in overall system response when the mass, center of gravity, or gaps are changed, but the changes in response are within the bounds of a system that contains completely homogeneous fuel assemblies. One important observation is that the loading for each individual fuel assembly within the vertical canister is expected to be different from that of the others because of nonlinearities in the system. The horizontal canister system is expected to have a more uniform and more predictable response than the vertical canister, making variations in fuel assembly characteristics easier to account for. One important recommendation that comes from this modeling work is to repeat some of the strongest shake tests at different angles, particularly for the vertical cask system. Modeling predicts that strong seismic motion will cause the fuel assemblies to close initial gaps and impact the fuel basket walls when the canister is in the vertical cask configuration. Each shake test will impose a pre-defined three-dimensional time history on the cask system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

EVs@Scale Next-Gen Profiles - EV Profile Capture 2023

As part of the U.S. DOE EVs@Scale consortium Next-Gen Profiles (NGP) project, the profile capture of production electric vehicles undergoing high power charging (HPC) is conducted over a wide range of conditions to explore variance and performance. Charge session parameters are collected from both the electric vehicle (EV) and electric vehicle supply equipment (EVSE) at a rate of 10Hz and entered into a time-series database for analysis. These charge profiles are captured under nominal and off-nominal conditions, exploring the impact of battery state of charge (SOC), battery temperature, vehicle condition, smart charge management (SCM), and EVSE limitations. Nominal conditions are defined to be ideal conditions that should transfer the maximum allowable energy in the minimum possible amount of time. Nominal condition profiles are compared across EVs to characterize state-of-the-art EV charging performance against one another. Off-nominal condition profiles are compared against its nominal condition profile counterpart to highlight the variance across less desirable starting conditions within a single EV. Under nominal conditions, most EVs can achieve the original equipment manufacturer (OEM) rated peak-power and charge times. Peak power across EVs has variance due to the vehicle design, battery topology, charging strategy, etc. These 10-100% nominal preconditioned charge profiles across 13 EVs (11 light-duty (LD), 2 heavy-duty (HD)) were used for analysis in power curve analysis, power distribution, SOC and range comparison, thermal impacts of current draw, battery pack size and energy charged, and ramp rates. Power curve analysis show the uniqueness in power vs time curves across all EVs, breaking down the features of a typical profile and where variation is typically seen. Power distribution results showed that over 50% of charge time is spent below 50kW and only 12.1% is spent above 200kW. SOC and range performance yielded different top performing EVs when exploring goals of performance from SOC and range gained after 10-min (EV2) and 20-min (EV8), and time-to-achieve 80% SOC (EV8) and 200 miles of range (EV1). Current draw from 400-volt EVs had a higher thermal impact to cable/connector temperatures when compared to 800-volt EVs, due to a higher current requirement to achieve similar power levels. There was high variance in C rating, a useful metric when comparing the relationship between peak/average charge session power and relative battery pack size, across EVs under test. Ramp rates during initial power transfer were examined, fastest and slowest speeds ranging from 192.5kW/second to 2.6kW/second respectively. A similar analysis of ramp rates was also conducted for OCPP curtailment testing, where EVs underwent a 2-minute 65A curtailment request before returning to full-power charge. Under off-nominal conditions, most EVs experienced variation from the nominal condition profiles. EVs that underwent the full set of NGP defined testing conditions were compared, analysis of which was categorized by 800-volt and 400-volt EVs. It should be noted that the 800-volt EVs had significantly higher peak power ratings than the 400-volt EVs, and thus were more prone to variance. Initial state of charge, battery temperature, and vehicle condition had a considerable impact on peak power levels and charge time for the 800-volt vehicles under test. EVSE limited tests lowered achievable power down to 200kW, greatly impacted 800-volt charging power, and had little to no effect on 400-volt charging power. Adapter testing was performed on a single 400-volt EV, where power and current limitations were found but overall charge time was not significantly impacted. Adapter and boost converter testing was performed on a single 800-volt EV, where both charge power and charge time were greatly impacted. Charge profiles are unique, and comparing such requires analysis that examines starting conditions, vehicle and battery topologies,

Charging↗

Sensitivity analysis of an automated fault detection algorithm for residential air-conditioning systems

The state of the art of fault detection and diagnosis (FDD) for residential air-conditioning systems is expensive and not yet amenable to widespread implementation. FDD for homes can significantly reduce utility costs, and increase the lifespan of the equipment. The cost barriers currently, however, make FDD for homes economically unviable for large scale implementation. In prior work, we offered a solution to reduce FDD costs by proposing an automated fault detection algorithm to serve as a screening step before more expensive FDD tests can be conducted. The algorithm uses only the home thermostat and local weather information to identify thermodynamic parameters and detect high-impact air-conditioning faults, including those that occur during equipment installation. We had tested the algorithm on a single EnergyPlus™ model of a home in Orlando, Florida. The thermodynamic parameter identification process is highly nonconvex involving several local optimal solutions. In this paper we propose a novel method to select the best model for fault detection from among the list of local optimal solutions to make the algorithm more robust to homes of different construction, without which the fault detection process would be infeasible. Another unique contribution of the paper is implementing the solution on real-world data. We also bring the algorithm closer to market by testing it on real-world data. We implement the algorithm on data obtained from experiments conducted by the Florida Solar Energy Center (FSEC) on a laboratory home equipped with a heat pump where faults were intentionally added for a period of seven months. The algorithm successfully detected an undercharge fault with 70.6% accuracy, concurrent duct leakage and undercharge faults with 85.2% accuracy, and duct leakage faults with 69.1% accuracy. A sensitivity analysis is also performed on EnergyPlus models of nine types of homes that vary in construction to demonstrate the robustness of the algorithm. Finally, the algorithm achieves an average accuracy of 71% for no-fault condition, 77% for 40% undercharge fault, and 76% for duct-leak fault.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Communication—Impact Behaviors of Pouch and Prismatic Battery Modules

The responses of pouch and prismatic battery modules when they are impacted by two types of indenters from three different directions are investigated experimentally. The test results show that the failure mechanism, peak force and penetration that leads to short-circuit in modules strongly depend on the impact direction, indenter shape, cell form factor and module design. It sheds lights on the abuse tolerance of batteries in different scenarios and demonstrates that the cell type, orientation and module structure should be considered simultaneously in order to improve the battery safety in electrical vehicles.

Electrochemistry↗

Vulnerability Studies Under EMP: Impedance and PCI Testing of the Grid Control Devices

Control devices such as inverters and generator controllers are critical for the stable operation of the power grid, especially for power stability control and power dispatch. However, the Electromagnetic Pulse (EMP) is a potential threat to electronic devices in modern power grids, therefore decreasing the power grid resilience and bringing unrecoverable damages to the devices. To reveal the impact mechanism of the EMP, impedance and Pulse Current Injection (PCI) testing is established to study the vulnerability of the grid control devices. The impedance of the grid control devices is accurately measured using impedance analyzers with different frequency ranges. Then the voltage and current responses are tested based on the PCI testing. The vulnerability experiments based on two grid control devices are carried out. And the comparison results reveal that most ports would be damaged under EC8, and some ports can survive under EC5 according to the calculated PCI response and cumulative energy. The results can provide a reference for the future design of control devices and the strategic resilience of power grids.

Qiu, Wei↗

Development and Testing of a new Current-Regulated Arc Modulator for the LINAC

In this study, the performance of a current-regulated arc modulator was investigated with a focus on its role in initiating and sustaining plasma discharge within the Magnetron Body of the LINAC system. The analysis centered on how switching components, circuit topology, and feedback loop architecture influence critical factors such as energy efficiency, discharge stability, and long-term plasma containment. Particular attention was given to variations in pulse termination behavior, as observed through oscilloscope traces, which revealed inconsistencies affecting the duty factor and cathode temperature. These fluctuations have downstream effects on the cesium-coated cathode surface, thereby impacting H⁻ ion production and beam reliability. Simulation-based testing in LTspice was used to evaluate noise suppression techniques and arc current regulation schemes, revealing how optimized snubber networks, improved pulse shaping, and feedback stability can mitigate modulator-induced noise. The results identified hardware level parameters that significantly enhance discharge repeatability and improve overall plasma performance under operational conditions.

Campos, Nathan [Unlisted, US; Fermilab]↗

Role of Fe in long-range ordered Ni 2 Cr precipitates in Ni-Cr-Fe model alloys during isothermal aging

The precipitation of new phases during long-term service at elevated temperatures is a concern for the thermal stability of engineering alloys. In Ni-Cr-based alloys, e.g., Alloy 690, the formation of long-range ordered Ni 2 Cr causes embrittlement and may impact the lifetime of nuclear power plant components. In this work, we quantify the formation and evolution of Ni 2 Cr precipitation in eleven Ni-Cr-Fe model alloys with 0, 5, 7, and 10wt % Fe contents, and with Ni/Cr atomic ratios of 1.8, 2.0, 2.2, 2.4. These alloys were isothermally aged up to 10,000h at temperatures between 330 and 475°C. The alloys were characterized by synchrotron-based x-ray diffraction and Vickers hardness testing to quantify Ni 2 Cr precipitate size, and the impact of precipitate size on the mechanical properties as a function of Fe content. After 10,000 h of aging at 475°C and 418°C, the formation of Ni 2 Cr was observed in all alloys with 0 and 5wt % Fe. After 10,000h of aging at 418°C, Ni 2 Cr precipitates were also observed in the 7wt % Fe containing Ni/Cr=2.0 sample. Further, no clear evidence of Ni 2 Cr was observed in any of the 10wt % Fe samples at any time and temperature combination. We find that the face-centered cubic matrix lattice contraction and Vickers hardness are correlated with the Ni 2 Cr formation. The greatest change in hardness and lattice contraction occurs in stoichiometric alloys (Ni/Cr=2.0) with 0wt % Fe at 475°C. The rate of change in the material properties for the 5wt % Fe alloys is reduced, however the magnitude of changes is similar to 0wt % Fe alloys. A precipitation hardening model developed for Ni-Cr alloys based on critical resolved shear stress with weakly coupled dislocations shows a clear link between Ni 2 Cr precipitate size and hardness. This trend held across all alloys with Ni 2 Cr formation regardless of Fe concentration. This important structure-property relationship can potentially help define Ni-Cr-Fe-based component lifetimes directly through an understanding of how Ni 2 Cr formation impacts mechanical properties as a function of Fe content.

36 MATERIALS SCIENCE↗

Mechanical Modeling and Testing of Pouch Cells under Various Loading Conditions

Understanding the mechanical behaviors of batteries is critical to improve battery safety since mechanical failure may directly lead to short-circuits. Nevertheless, mechanical modeling of batteries is challenging since a cell usually contains multiple thin layers with drastically different material properties, and they exhibit different responses under different loading conditions. In this work, we developed a mechanical model for a large-format pouch cell, where the cell is represented by thick shell elements that are not only computationally efficient but also account for different thickness and material properties of individual components. Moreover, the mechanical properties of active materials in electrodes are described by a continuous surface cap model that can capture both compaction and shear deformation modes and can include strain rate effect and damage. Furthermore, to evaluate the model capabilities, we conducted abuse tests under various loading conditions (quasi-static compression, shear and impact). It is shown that the model prediction of load-displacement relationship and failure condition agree with experimental results, which demonstrates that the developed model can capture the mechanical behaviors of a cell in different abuse events. Details of element formulation, material parameters evaluation and test setup are presented. Capabilities, limitations and future directions of model development are also discussed.

25 ENERGY STORAGE↗

Analysis of the Source Physics Experiment Dry Alluvium Geology Ball Drop Sources

Two balls were dropped approximately 150 m down an open borehole as part of an investigation into the aftershocks from a 51 ton TNT-equivalent chemical explosion. The ball drop sources, a concrete-filled basketball and a bowling ball, were intended to mimic falling debris within an underground explosion borehole and cavity. Falling debris or sloughing of the borehole and cavity walls is thought to be one of the sources of explosion aftershocks. The signals from the ball drop sources were recorded by the same seismic network that monitored the aftershocks of the chemical explosion, so the ball drop recordings were used as templates to search through the continuous stream of aftershocks and detect correlated signals as a proportion of all aftershocks. The search resulted in only four similar event recordings out of the thousands of detected aftershocks. A synthetic test showed that the small, high-frequency ball drop templates were limited to producing highly correlated detections for events occurring in a small region around the impact location at 150 m depth. The high-frequency templates were necessary since the small ball drop signals were only above the noise at frequencies greater than 10 Hz. Unfortunately, the impact location is where the borehole was filled with sand in preparation for the subsequent chemical explosion in the test series, making it 150 m above the explosion created cavity centered at 300 m depth. This puts the ball drop templates 150 m away from the cavity, where many more events from falling debris would be expected. Further synthetic tests confirmed events emanating from the cavity 150 m below the impact site would have correlated with the lower frequency template and been detected had the template been usable below 10 Hz. Therefore, we conclude that the four detected events were most probably falling debris within the open borehole that impacted the floor at 150 m depth just as the ball drop sources had, and that this type of explosion aftershock mechanism comprises less than 1% of all explosion aftershocks.

58 GEOSCIENCES↗

The NOvA Test Beam Program

NOvA is a long-baseline oscillation neutrino experiment designed to study and measure a wide range of important topics for neutrino physics such as the neutrino mixing parameters, the neutrino mass hierarchy, and CP violation in the lepton sector. The NOvA Test Beam experiment uses a scaled-down detector of 30 tons to analyze tagged beamline particles. A new tertiary beamline deployed at Fermilab can select and identify electrons, muons, pions, kaons and protons with momenta from 0.2 to 2 GeV/c. Using these data, the Test Beam program will provide NOvA with a better understanding of the largest systematic uncertainties impacting the analyses, including the detector response, calibration, and hadronic and electromagnetic energy resolution. The status and future plans for the NOvA Test beam program, along with preliminary results, are presented in these Proceedings.

43 PARTICLE ACCELERATORS↗

Limitations of Hydrogen Detection After 150 Years of Research on Hydrogen Embrittlement

Hydrogen's significance in contemporary society lies in its remarkable energy density, yet its integration into the worldwide energy grid presents a substantial challenge. Exposing materials to hydrogen environments leads to degradation of mechanical properties, damage, and failure. While the current approach for assessing hydrogen's impact on materials involves mainly multiscale modeling and mechanical testing, there exists a significant deficiency in detecting the intricate interactions between hydrogen and materials at the nanoatomic scales and under in situ conditions. This perspective review highlights the experimental endeavors aimed at bridging this gap, pointing toward the imminent need for new experimental techniques that can detect and map hydrogen in materials’ microstructures and their site‐specific dependencies.

Tunes, Matheus A.↗

Efficacy and Costs of Restoring Wetland Breeding Habitat for Imperiled Amphibians in the Southeastern U.S.

Herbaceous isolated wetlands in the North American Southeastern Coastal Plain are important breeding sites for many imperiled amphibians. However, most are degraded from alterations to historic fire disturbance and hydrologic regimes. Without fire, encroaching woody vegetation can transition wetlands to more terrestrial conditions and negatively impact amphibian breeding habitat, yet few studies have experimentally tested the efficacy, cost, or temporal requirement of current methods to restore herbaceous wetland vegetation. Here, we tested the interaction of manipulating wetland canopy and leaf litter/duff to promote herbaceous vegetation within one year (i.e., one breeding season) in degraded herbaceous wetlands in South Carolina. We assessed plant response via herbaceous cover, composition, and species similarity to the wetland seed bank and then related treatment performance to treatment cost. Removing trees combined with burning, disturbing, or removing duff significantly increased herbaceous cover and proportions of wetland plants and graminoids. Removing trees alone did not improve herbaceous cover compared to closed-canopy controls, and manipulating duff alone had limited positive effects on plant cover and composition. The most expensive yet effective treatment was Tree Removal-Duff Removal, while Tree Removal-Duff Disturbance was the most cost-effective. At a minimum, we recommend removing trees and burning to kickstart herbaceous recovery. Promisingly, comparisons of our data with previous seed bank studies from these same wetlands indicate there was limited seed bank attrition during 30 years of woody encroachment. Results from this study should aid practitioners in choosing wetland restoration techniques to better conserve at-risk species in the Southeastern Coastal Plain.

54 ENVIRONMENTAL SCIENCES↗

Thermal energy storage in concrete: Review, testing, and simulation of thermal properties at relevant ranges of elevated temperature

This study examines the thermal performance of concrete used for thermal energy storage (TES) applications. The influence of concrete constituents (aggregates, cementitious materials, and fibers) on the thermal conductivity and specific heat are summarized based on literature and via experimentation at elevated temperatures. It is indicated that concrete with siliceous aggregate, low water/cement ratios, and steel fibers produces better overall thermal properties. The results of literature review and laboratory testing are used for numerical simulation to evaluate the impact of concrete thermal property variability on TES capabilities. The TES module consists of the heat exchanger and surrounding concrete as the storage media. Both idealized cases without heat loss and realistic cases with insulation and heat losses are considered. Furthermore, the result shows that conventional concrete mixes can be tailored to decrease the module charge/discharge durations and increase the amount of thermal energy storage.

25 ENERGY STORAGE↗

Visualization, understanding, and mitigation of process-induced-membrane irregularities in gas diffusion electrode-based polymer electrolyte membrane fuel cells

Polymer electrolyte membrane fuel cells (PEMFC) show substantial promise for their application in electric vehicles. For large-scale manufacturing of PEMFCs, roll-to-roll coated gas-diffusion-electrodes (GDE) offer certain advantages over other production pathways. Procedures including hot pressing and coating an ionomer overlayer may be necessary for this manufacturing pathway to enable a suitable catalyst layer/membrane interface. The same procedures may potentially introduce membrane irregularities, especially when thin membranes are used. Limited understanding exists regarding if and to what extent such irregularities impact PEMFC performance and lifetime, and therefore be considered defects. In this study, NREL's customized fuel cell hardware that enables quasi in-situ infrared (IR) thermography studies was utilized to visualize spatial hydrogen crossover and identify membrane irregularities that originated from the GDE-based MEA fabrication process. The structure of these membrane irregularities was investigated by scanning electron microscopy (SEM) and its impact on initial H2/air performance was determined. Accelerated stress testing (AST) revealed that these irregularities develop into failure point locations. These results were validated across many MEAs with identified process-induced membrane irregularities. By selecting specific gas diffusion media properties and by fine tuning the MEA hot pressing parameters, the formation of such membrane irregularities was mitigated.

08 HYDROGEN↗

Divertor characterization and access to dissipative divertor conditions in negative triangularity discharges in DIII-D

Reduced radial transport, short midplane-to-target parallel connection lengths, and a strong effect of cross-field drifts were responsible for the high densities required for detachment in strong negative triangularity (NT) configurations in DIII-D. Dissipative divertor conditions were achieved in NT discharges at different triangularity, injected power, plasma current, and toroidal field direction. Differences between negative and positive triangularity (PT) discharges are analyzed in this paper to understand the requirements for access to detached divertor conditions: power balance, geometry, radial transport and effect of cross-field particle drifts. Parametric dependencies of access to detachment on plasma current and power flowing into the scrape-off layer remained similar in negative and PT and impurity seeding was observed to reduce the density needed to detach by up to 30% at the expense of core impurity dilution. The impact of triangularity on core-edge integration was tested varying bottom triangularity at fixed top triangularity. The high density needed to detach was not intrinsic to the NT edge as shapes with positive lower triangularity and negative upper triangularity were able to detach at lower upstream densities while maintaining an ELM-free NT edge. Confinement degradation at deeper detachment levels was however observed in all NT shapes, often associated with radiation instabilities.

detachment↗