Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Focused Ion Beam analysis of non radioactive samples [PowerPoint]

The presentation includes various images to illustrate the analysis. Helios G4 Plasma FIB: Xe ion columns mills material 30 times faster than Ga; Options include: Energy Dispersive Spectroscopy (EDS), Wavelength Dispersive spectroscopy (WDS) Electron backscattered Diffraction (EBSD), Time of Flight Sims (ToF SIMS), Inert gas/vacuum sample transfer system; Excels at micromachining and collecting 3D datasets using various detection systems.

42 ENGINEERING↗

Weak shock compaction on granular salt

This study conducted integrated experiments and computational modeling to investigate the speeds of a developing shock within granular salt and analyzed the effect of various impact velocities up to 245 m/s. Experiments were conducted on table salt utilizing a novel setup with a considerable bore length for the sample, enabling visualization of a moving shock wave. Experimental analysis using particle image velocimetry enabled the characterization of shock velocity and particle velocity histories. Mesoscale simulations further enabled advanced analysis of the shock wave’s substructure. In simulations, the shock front’s precursor was shown to have a heterogeneous nature, which is usually modeled as uniform in continuum analyses. The presence of force chains results in a spread out of the shock precursor over a greater ramp distance. With increasing impact velocity, the shock front thickness reduces, and the precursor of the shock front becomes less heterogeneous. Furthermore, mesoscale modeling suggests the formation of force chains behind the shock front, even under the conditions of weak shock. This study presents novel mesoscale simulation results on salt corroborated with data from experiments, thereby characterizing the compaction front speeds in the weak shock regime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

First Images of the Protoplanetary Disk around PDS 201

Scattered light imaging has revealed nearly a dozen circumstellar disks around young Herbig Ae/Be stars—enabling studies of structures in the upper disk layers as potential signs of ongoing planet formation. We present the first images of the disk around the variable Herbig Ae star PDS 201 (V* V351 Ori) and an analysis of the images and spectral energy distribution through 3D Monte Carlo radiative transfer simulations and forward modeling. The disk is detected in three data sets with the Large Binocular Telescope Interferometer/Large Binocular Telescope mid-infrared camera at the Large Binocular Telescope, including direct observations in the Ks and L′ filters, and an L′ observation with the 360° vector apodizing phase plate coronagraph. The scattered light disk extends to a very large radius of ∼250 au, which places it among the largest of such disks. Exterior to the disk, we establish detection limits on substellar companions down to ∼5 M {sub Jup} at ≳1.″5 (≳500 au), assuming the Baraffe et al. models. The images show a radial gap extending to ∼0.″4 (∼140 au at a distance of 340 pc) that is also evident in the spectral energy distribution. The large gap is a possible signpost of multiple high-mass giant planets at orbital distances (∼60–100 au) that are unusually massive and widely separated compared to those of planet populations previously inferred from protoplanetary disk substructures.

79 ASTRONOMY AND ASTROPHYSICS↗

Pit depth analysis using automated software for three containers with complete imaging

The 3013 surveillance program is tasked with ensuring the long term safety of plutonium storage in 3013-compliant containers. One component of this task is to understand corrosion features found on the interior sidewall of the inner container closure weld region (ICCWR). To this end, three containers were selected to have laser confocal microscope (LCM) 20X imaging of the entire ICCWR. This report describes the analysis of the LCM pit depth data using the automated corrosion analysis software. The analysis included determining maximum pit depths and distributions of pit depths, volumes, and diameters for all pit features identified on the three containers. Results provided insight into possible corrosion mechanisms and were consistent with previous pit growth model predictions.

36 MATERIALS SCIENCE↗

Quantification and visualization of uncertainties in reconstructed penumbral images of implosions at Omega

Penumbral imaging is a technique used in plasma diagnostics in which a radiation source shines through one or more large apertures onto a detector. To interpret a penumbral image, one must reconstruct it to recover the original source. The inferred source always has some error due to noise in the image and uncertainty in the instrument geometry. Interpreting the inferred source thus requires quantification of that inference’s uncertainty. Markov chain Monte Carlo algorithms have been used to quantify uncertainty for similar problems but have never been used for the inference of the shape of an image. Because of this, there are no commonly accepted ways of visualizing uncertainty in two-dimensional data. This paper demonstrates the application of the Hamiltonian Monte Carlo algorithm to the reconstruction of penumbral images of fusion implosions and presents ways to visualize the uncertainty in the reconstructed source. This methodology enables more rigorous analysis of penumbral images than has been done in the past.

Instruments & Instrumentation↗

Advancing subsurface analysis: Integrating computer vision and deep learning for the near real-time interpretation of borehole image logs in the Illinois Basin-Decatur Project

The accurate quantification and mapping of subsurface natural fracture systems using borehole imaging logs are critical for the success of CO 2 sequestration in geologic formations, optimization of engineered geothermal systems, and hydrocarbon production enhancement. However, traditional interpretation processes suffer from time-consuming procedures and human bias. To address these challenges and expedite fracture analysis, we investigated the application of integrated computer vision and DL workflows to automate image log analysis. Specifically, the design of our workflow was crafted to swiftly detect fractures and baffles by using actual electrical resistivity of borehole wall from microresistivity imaging device alongside their binary representation. This novel approach significantly reduces computational time while providing invaluable insights. By incorporating conventional logging and microseismic data, we present a regional subsurface natural fracture mapping technique. Through the minimization of human bias in image log analysis, our automated workflow achieves reduced fracture interpretation time and costs while ensuring robust and reproducible results. We demonstrated the efficacy of our approach by applying the workflow to the Illinois Basin-Decatur Project site. The automated workflow successfully identified major fractured zones, multiple baffles, and an interbedded layer with a high resolution of 0.01 ft or 0.12 in. (0.3 cm) and can be upscaled to any desired resolution. Validation through microseismic and image log interpretations allows for accurate and near-real-time mapping of fractures and baffles, significantly enhancing CO 2 pressure forecasting and postinjection site care. Our approach stands out due to its robustness, consistency, and reduced computational cost compared with alternative feature extraction technologies. It presents exciting possibilities for advancing CO 2 sequestration and engineered geothermal efforts by offering comprehensive and efficient fracture mapping solutions. This technology can contribute significantly to the optimization of CO 2 sequestration projects, facilitating sustainable environmental practices, and combating climate change.

Geochemistry & Geophysics↗

LIvermore SEM image Tools

Scanning Electron Microscopy (SEM) images provide a variety of structural and morphological information for the characterization of the nanomaterials. This code offers automatic recognition and quantitative analysis of SEM images in a high-throughput manner using computer vision and machine learning techniques. The main function of this application is to extract particle size and morphology information of overlapping nanoparticles and core-shell nanostructures in a user friendly interface. The code is written in C++ with QT environment, and has been tested on MacOSX.

KIM, HYOJIN↗

Enhancing segmentation fairness through curriculum learning and progressive loss: a centralized and federated perspective on radiograph analysis

Bias in medical image segmentation can lead to unequal performance across demographic subgroups, raising concerns about fairness and reliability in clinical AI systems. While deep learning models have achieved high segmentation accuracy, ensuring equitable performance across race and gender remains a significant challenge, particularly in privacy-sensitive healthcare environments. This study investigates fairness-aware medical image segmentation for hip and knee radiographs using deep learning models evaluated in both centralized and Federated Learning (FL) settings. We introduce Curriculum Learning (CL) strategies and Progressive Loss (PL) functions to regulate sample difficulty during training. In addition, we propose two novel fairness-oriented federated learning algorithms, Federated Intersection over Union (FedIoU) and Federated Intersection over Union with Outlier Analysis (FedIoUoutlier). Experiments are conducted using multiple segmentation backbones and simulated multi-site data partitions derived from the Osteoarthritis Initiative dataset. Model performance is evaluated using Intersection over Union (IoU), IoU standard deviation, Skewed Error Ratio (SER), and Min-Max Disparity across race and gender subgroups. Statistical significance was verified using paired t-tests to compare per-sample IoU performance against baseline configurations. Across both hip and knee segmentation tasks, curriculum learning and progressive loss strategies consistently improved segmentation accuracy and reduced demographic performance disparities in centralized training. In federated settings, fairness-aware aggregation further enhanced performance. Notably, FedIoUoutlier combined with balanced curriculum learning and tiered progressive loss achieved the highest mean IoU while yielding the lowest SER and Min-Max Disparity, indicating improved fairness without sacrificing accuracy. In several configurations, federated models matched or exceeded the performance of optimized centralized models, with statistically significant improvements in per-sample IoU over baseline configurations. The results demonstrate that structured training strategies and fairness-aware federated aggregation can jointly improve accuracy, stability, and demographic fairness in medical image segmentation. By integrating curriculum learning, progressive loss, and novel FL algorithms, this work provides a practical pathway toward equitable and privacy-preserving AI systems for medical imaging.

97 MATHEMATICS AND COMPUTING↗

Artificial illumination identification from an unmanned aerial vehicle

Artificial illumination identification within images is a useful tool for many applications. Performing such identification allows for an estimation of the illumination source spectrum, which in turn can be used for additional applications ranging from spectral detection and exploitation to statistics about nighttime light usage. Illumination identification has been performed in laboratory settings but not from an unmanned aerial vehicle (UAV) platform. Here, we test the feasibility of using a UAV and commercial off-the-shelf multispectral imaging sensor to perform such artificial illumination identification through linear discriminant analysis using nighttime UAV images. The results are very promising, showing source classification accuracies of 83.3%, 92.3%, 100%, and 100% for the incandescent, light-emitting diode, high pressure sodium, and metal halide illumination sources, respectively. We show that the information gained from the source identification can be further used to inform additional analysis, such as spectral identification. The high resolution of UAV imaging techniques combined with the knowledge of the illumination source can lead to better exploitation of such nighttime data for many applications.

42 ENGINEERING↗

Evidence of an oxidation induced phase transformation for a delta phase plutonium-gallium alloy

The oxidation of an ~1.5 at% Ga plutonium metal alloy in dry air as a function of time was studied using a combination of FIB-SEM, AES, and XRD. Analysis of SEM images of FIB cross-sections of the oxide allowed for direct measurement of the oxide thickness as well as determination of heterogeneity in the extent of the oxide. AES analysis performed on cross-sections of the oxide allowed for quantitative analysis of the atomic composition and semi-quantitative analysis of the chemical composition. Initial preparation of the sample was found to induce a martensitic transformation to α' - Pu with an average thickness of 233 nm. Electropolishing was found to be sufficient to fully remove the α' layer with creation of only a minimum oxide layer. Growth of the oxide in dry air was found to initially follow parabolic kinetics, with a parabolic rate constant orders of magnitude higher than expected for δ-Pu but in-line with values extrapolated to room temperature for α-Pu. Following complete oxidation of the initial α` layer, further regions of plutonium metal depleted in gallium were observed to form at the oxide / metal interface. However, gallium, as Ga 2 O 3 , was found to be enriched at the surface and present in the oxide in an amount comparable to the relative Ga:Pu ratio of the bulk metal alloy. Finally, the results presented here serve to bridge a diverse array of previous experimental and theoretical data and provide the first comprehensive view of the fate of the δ-stabilizer during formation of an oxide.

36 MATERIALS SCIENCE↗

Our teams design high-resolution MeV x-ray radiography systems for National security missions [Poster]

The NNSS has been at the forefront of custom high-fidelity x-ray/gamma radiographic imaging solutions that serve our national security for over five decades. Our radiography team utilizes expertise in physics modeling and analysis, along with optical, mechanical, and electrical design, in close collaboration with our customers, to develop imaging methods and capabilities that go beyond their needs. Conceptual designs are developed through R&D efforts to provide solutions for the specific problem at hand. Field systems are designed and built in-house, then qualified utilizing a range of facilities across the National Security Enterprise. Radiographic imaging systems are deployed by our team in the most challenging environments. The NNSS has a strong math and programming team that provides novel on-site image analysis methods that extract crucial information from data returned in field tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of Transmission Electron Microscopy for Analysis of Aerosol Particles and Strategies for Imaging Fragile Particles

For over 25 years, transmission electron microscopy (TEM) has provided a method for the study of aerosol particles with sizes from below the optical diffraction limit to several microns, resolving the particles as well as smaller features. The wide use of this technique to study aerosol particles has contributed important insights about environmental aerosol particle samples and model atmospheric systems. TEM produces an image that is a 2D projection of aerosol particles that have been impacted onto grids and, through associated techniques and spectroscopies, can contribute additional information such as the determination of elemental composition, crystal structure, and 3D particle structures. Soot, mineral dust, and organic/inorganic particles have all been analyzed using TEM and spectroscopic techniques. TEM, however, has limitations that are important to understand when interpreting data including the ability of the electron beam to damage and thereby change the structure and shape of particles, especially in the case of particles composed of organic compounds and salts. In this paper, we concentrate on the breadth of studies that have used TEM as the primary analysis technique. Another focus is on common issues with TEM and cryogenic-TEM. Insights for new users on best practices for fragile particles, that is, particles that are easily susceptible to damage from the electron beam, with this technique are discussed. Tips for readers on interpreting and evaluating the quality and accuracy of TEM data in the literature are also provided and explained.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Small animal PET: a review of what we have done and where we are going

Abstract Small animal research is an essential tool in studying both pharmaceutical biodistribution and disease progression over time. Furthermore, through the rapid development of in vivo imaging technology over the last few decades, small animal imaging (also referred to as preclinical imaging) has become a mainstay for all fields of biologic research and a center point for most preclinical cancer research. Preclinical imaging modalities include optical, MRI and MRS, microCT, small animal PET, ultrasound, and photoacoustic, each with their individual strengths. The strong points of small animal PET are its translatability to the clinic; its quantitative imaging capabilities; its whole-body imaging ability to dynamically trace functional/biochemical processes; its ability to provide useful images with only nano- to pico- molar concentrations of administered compounds; and its ability to study animals serially over time. This review paper gives an overview of the development and evolution of small animal PET imaging. It provides an overview of detector designs; system configurations; multimodality PET imaging systems; image reconstruction and analysis tools; and an overview of research and commercially available small animal PET systems. It concludes with a look toward developing technologies/methodologies that will further enhance the impact of small animal PET imaging on medical research in the future.

Engineering↗

Quantitative and qualitative bone imaging: A review of synchrotron radiation microtomography analysis in bone research

All levels of the unique hierarchical structure of bone, consisting of collagen and hydroxyapatite crystals at the nanoscale to osteon/lamellae structures at the microscale, contribute to its characteristic toughness and material properties. Elements of bone's density and size contribute to bone quantity (or bone mass), whereas elements of bone's material composition, material properties, internal structure, and organization describe bone quality. Furthermore, bone quantity and quality can be degraded by factors such as aging, disease, treatments, and irradiation, compromising its ability to resist fracture and sustain loading. Accessing the morphology and architecture of bone at the microscale to quantify microstructural features and assess the degree of mineralization and path of crack propagation in bone provides crucial information on how these factors are influencing bone quantity and quality. Synchrotron radiation micro-computed tomography (SRμCT) was first used to assess bone structure at the end of the 1990's. One of the main advantages of the technique is that it enables accurate three-dimensional (3D), non-destructive quantification of structure while traditional histomorphometry on histological sections is inherantly destructive to the sample and two-dimensional (2D). Additionally, SRμCT uses monochromatic, high-flux X-ray beams to provide high-resolution and high-contrast imaging of bone samples. This allows the quantification of small microstructural features (e.g. osteocyte lacunae, canals, trabeculae, microcracks) and direct gray value compositional mapping (e.g. mineral quantification, cement lines) with greater speed and fidelity than lab-based micro-computed tomography. In this article, we review how SRμCT has been applied to bone research to elucidate the mechanisms by which bone aging, disease, and other factors affect bone fragility and resistance to fracture.

60 APPLIED LIFE SCIENCES↗

Photofragment imaging differentiates between one- and two-photon dissociation pathways in MgI+

The bond strength and photodissociation dynamics of MgI+ are determined by a combination of theory, photodissociation spectroscopy, and photofragment velocity map imaging. From 17 000 to 21 500 cm−1, the photodissociation spectrum of MgI+ is broad and unstructured; photofragment images in this region show perpendicular anisotropy, which is consistent with absorption to the repulsive wall of the (1) Ω = 1 or (2) Ω = 1 states followed by direct dissociation to ground state products Mg+ (2S) + I (2P3/2). Analysis of photofragment images taken at photon energies near the threshold gives a bond dissociation energy D0(Mg+-I) = 203.0 ± 1.8 kJ/mol (2.10 ± 0.02 eV; 17 000 ± 150 cm−1). At photon energies of 33 000–41 000 cm−1, exclusively I+ fragments are formed. Over most of this region, the formation of I+ is not energetically allowed via one-photon absorption from the ground state of MgI+. Images show the observed product is due to resonance enhanced two-photon dissociation. The photodissociation spectrum from 33 000 to 38 500 cm−1 shows vibrational structure, giving an average excited state vibrational spacing of 227 cm−1. This is consistent with absorption to the (3) Ω = 0+ state from ν = 0, 1 of the (1) Ω = 0+ ground state; from the (3) Ω = 0+ state, absorption of a second photon results in dissociation to Mg* (3P°J) + I+ (3PJ). From 38 500 to 41 000 cm−1, the spectrum is broad and unstructured. We attribute this region of the spectrum to one-photon dissociation of vibrationally hot MgI+ at low energy and ground state MgI+ at higher energy to form Mg (1S) + I+ (3PJ) products.

Chemistry↗

Interlaboratory Study of Digital Volume Correlation Error Due to X-Ray Computed Tomography Equipment and Scan Parameters: an Update from the DVC Challenge

Background: The quality of Digital Volume Correlation (DVC) full-field displacement measurements depends directly on the characteristics of the X-ray Computed Tomography (XCT) equipment, and scan procedures used to acquire the tomographic images. Objective: In this work, we seek to experimentally study the effects of XCT equipment and tomographic scan procedures on the quality of these images for DVC analysis, and to survey the level of DVC error that may be achieved using standard XCT operating procedures. Methods: Six participants in an interlaboratory study acquired high-quality XCT scans of a syntactic foam before and after rigid body motion. The resulting images were correlated using commercial DVC software to quantify error sources due to random image noise, reconstruction artifacts, as well as systematic spatial or temporal distortion. Results: In the absence of rigid body motion, the standard deviation of the displacement measurements ranged from 0.012 to 0.043 voxels using a moderate subvolume size, indicating that subvoxel measurement resolution could readily be achieved with a variety of XCT equipment and scan recipes. Comparison of consecutive scans without rigid body motion showed transient dilatational displacement gradients due to self-heating of the X-ray source and/or thermal expansion of the foam. Evaluation of the scans after rigid body motion showed significant, machine-specific spatial distortion in the displacement fields of up to 0.5 voxels; new approaches to remove this error need to be developed. Conclusions: Analysis of the scan protocols used in the interlaboratory study, as well as a complementary parametric sensitivity study, showed that the DVC error was strongly influenced by the XCT equipment, but could be mitigated by adjusting the total scan duration.

47 OTHER INSTRUMENTATION↗

Bayesian inference in band excitation scanning probe microscopy for optimal dynamic model selection in imaging

The universal tendency in scanning probe microscopy (SPM) over the last two decades is to transition from simple 2D imaging to complex detection and spectroscopic imaging modes. The emergence of complex SPM engines brings forth the challenge of reliable data interpretation, i.e., conversion from detected signals to descriptors specific to tip–surface interactions and subsequently to material’s properties. In this work, we implemented a Bayesian inference approach for the analysis of the image formation mechanisms in band excitation SPM. Compared to the point estimates in classical functional fit approaches, Bayesian inference allows for the incorporation of extant knowledge of materials and probe behavior in the form of corresponding prior distribution and return the information on the material functionality in the form of readily interpretable posterior distributions. We explore the nonlinear mechanical behaviors spatially in a classical ferroelectric material, PbTiO 3 . We observe the non-trivial evolution of the Duffing stiffness term and the nonlinearity of the sample surface, determine spatial clustering of the nonlinear response, and perform a Landau analysis on predicting the nonlinear coefficient, which indicates that ferroelectric behavior can be a cause of the observed results. These observations suggest that the spectrum of anomalous behaviors at the ferroelectric domain walls may be broader than previously believed and can extend to non-conventional mechanical properties in addition to static and microwave conductance.

36 MATERIALS SCIENCE↗

Understanding process-microstructure-property relationships in laser powder bed fusion of non-spherical Ti-6Al-4V powder

Powder feedstock is a major cost driver in metal additive manufacturing (AM). Replacing the spherical powder with the cost-efficient non-spherical one can reduce the feedstock cost up to 50% and attract more interest to adopt AM in production and new alloy development. Here, for this paper, a comprehensive study was conducted to understand process-microstructure-property relationships in laser powder bed fusion of hydride-dehydride Ti-6Al-4V powder. We demonstrated that variation of laser scan speed had a significant impact on the grain structure, pore evolution and properties compared to laser power. Dynamic X-ray radiography showed that with decreasing scan speed at a constant laser power, a transition from conduction to keyhole mode laser processing occurred, in which a deeper melt pool at lower scan speed intensified texture. In other words, an increase in laser scan speed resulted in formation of the refined prior β grains with shape factor of ~5, lowering the anisotropy. Furthermore, the degree of variant selection was evaluated based on the analyzed texture as a function of laser power and scan speed. With increasing laser scan speed, the dominant α/α boundary type was altered from type 2 to 4 and the degree of variant selection was noticeably decreased. On the other hand, increasing laser power left the morphology of prior β grains, their size, and the dominant α/α boundary (type 4) unchanged, while the texture and anisotropy were intensified, and the degree of variant selection was slightly decreased. Finally, dependency of surface roughness and microhardness were discussed as a function of laser processing parameters.

variant selection↗