Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ISOTOPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

SULFUR ISOTOPIC COMPOSITIONS OF SUBMICROMETER SiC GRAINS FROM THE MURCHISON METEORITE

We report C, Si, N, S, Mg-Al, and Ca-Ti isotopic compositions of presolar silicon carbide (SiC) grains from the SiC-rich KJE size fraction (0.5-0.8 μm) of the Murchison meteorite. One thousand one hundred thirteen SiC grains were identified based on their C and Si isotopic ratios. Mainstream, AB, C, X, Y, and Z subtypes of SiC, and X-type silicon nitride (Si{sub 3}N{sub 4}) account for 81.4%, 5.7%, 0.1%, 1.5%, 5.8%, 4.9%, and 0.4%, respectively. Twenty-five grains with unusual Si isotopic ratios, including one C grain, 16 X grains, 1 Y grain, 5 Z grains, and 2 X-type Si{sub 3}N{sub 4} grains were selected for N, S, Mg-Al, and Ca-Ti isotopic analysis. The C grain is highly enriched in {sup 29}Si and {sup 30}Si (δ{sup 29}Si = 1345‰ ± 19‰, δ{sup 30}Si = 1272‰ ± 19‰). It has a huge {sup 32}S excess, larger than any seen before, and larger than that predicted for the Si/S supernova (SN) zone, providing evidence against the elemental fractionation model by Hoppe et al. Two SN models investigated here present a more satisfying explanation in terms of a radiogenic origin of {sup 32}S from the decay of short-lived {sup 32}Si (τ{sub 1/2} = 153 yr). Silicon-32 as well as {sup 29}Si and {sup 30}Si can be produced in SNe by short neutron bursts; evidence for initial {sup 44}Ti (τ{sub 1/2} = 60 yr) in the C grain is additional evidence for an SN origin. The X grains have marginal {sup 32}S excesses, much smaller than expected from their large {sup 28}Si excesses. Similarly, the Y and Z grains do not show the S-isotopic anomalies expected from their large Si isotopic anomalies. Low intrinsic S contents and contamination with isotopically normal S are the most likely explanations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Isotope mass scaling and transport comparison between JET Deuterium and Tritium L-mode plasmas

The dimensionless isotope mass scaling experiment between pure Deuterium and pure Tritium plasmas with matched $\rho^*$, $\nu^*$ , β n , q and $T_e/T_i$ has been achieved in JET L-mode with dominant electron heating (NBI+ohmic) conditions. 28% higher scaled energy confinement time $B_t\tau_{E,\mathrm{th}}/A$ is found in favour of the Tritium plasma. This can be cast in the form of the dimensionless energy confinement scaling law as $\Omega_i \tau_{E,\mathrm{th}} \sim A^{0.48 \pm 0.16}$. This significant isotope mass scaling is consequently seen in the scaled one-fluid heat diffusion coefficient $A \chi_{\mathrm{eff}}/B_t$ which is around 50% lower in the Tritium plasma throughout the whole plasma radius. The isotope mass dependence in the particle transport channel is negligible, supported also by the perturbative particle transport analysis with gas puff modulation. The comparison of the edge particle fuelling or ionisation profiles from the EDGE2D-EIRENE simulations show that the absolute density differences that are necessary for the dimensionless match in the confined plasma dominate over any isotope mass dependencies of particle fuelling and ionization profiles at the plasma edge. Local GENE simulation results indicate a mild anti-gyroBohm effect at $\rho_\mathrm{tor}$ = 0.6 and thereby a small isotope mass dependence in favour of Tritium on heat transport and a negligible effect on particle transport. A significant fraction of the isotope scaling and reduced heat transport observed in the Tritium plasma is not captured in the GENE and ASTRA-TGLF-SAT2 simulations by simply changing the isotope mass for the same input profiles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Isotope shift in the sulfur electron affinity: Observation and theory

The sulfur electron affinities {sup e}A(S) are measured by photodetachment microscopy for the two isotopes {sup 32}S and {sup 34}S (16 752.975 3(41) and 16 752.977 6(85) cm{sup -1}, respectively). The isotope shift in the electron affinity is found to be more probably positive, {sup e}A({sup 34}S)- {sup e}A({sup 32}S) =+0.0023(70) cm{sup -1}, but the uncertainty allows for the possibility that it may be either ''normal''[{sup e}A({sup 34}S) > {sup e}A({sup 32}S)] or ''anomalous''[{sup e}A({sup 34}S) < {sup e}A({sup 32}S)]. The isotope shift is estimated theoretically using elaborate correlation models, monitoring the electron affinity and the mass polarization term expectation value. The theoretical analysis predicts a very large specific mass shift (SMS) that counterbalances the normal mass shift (NMS) and produces an anomalous isotope shift {sup e}A({sup 34}S)- {sup e}A({sup 32}S) =-0.0053(24) cm{sup -1}, field shift corrections included. The total isotope shift can always be written as the sum of the NMS (here +0.0169 cm{sup -1}) and a residual isotope shift (RIS). Since the NMS has nearly no uncertainty, the comparison between experimental and theoretical RIS is more fair. With respective values of -0.0146(70) cm{sup -1} and -0.0222(24) cm{sup -1}, these residual isotope shifts are found to agree within the estimated uncertainties.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-F-I-56: High-Precision Gamma-Ray Analysis of Medical Isotopes

Purpose: Advanced, time-resolved, Compton-suppressed gamma-ray spectroscopy with germanium detectors is implemented for assaying medical isotopes to study the radioactive decay process leading to a more accurate appraisal of the received dose and treatment planning. Lowell’s Array for Radiological Assay (LARA), a detector array that is comprised of six Compton-suppressed high-purity germanium detectors, is currently under development at UMass-Lowell which combines Compton-suppression and time-and-angle correlations to allow for highly efficient and highly sensitive measurements. Methods: Two isotopes produced Brookhaven Linac Isotope Producer (BLIP) were investigated. {sup 82}Sr which is the parent isotope for producing {sup 82}Rb is often used in cardiac PET. {sup 82}Sr gamma-ray spectrum is dominated by the 511keV photons from positron annihilation which prevent precise measurement of co-produced contaminant isotopes. A second project was to investigate the production of platinum isotopes. Natural platinum was bombarded with protons from 53MeV to 200MeV. The resulting spectrum was complicated due to the large number of stable platinum isotopes in the target, the variety of open reaction channels (p,xn), (p,pxn), (p,axn). Results: By using face-to-face NaI(Tl) counters 90-degrees to the Compton-suppressed germaniums to detect the 511keV photons, a much cleaner and more sensitive measurement of {sup 85}Sr and other contaminants was obtained. For the platinum target, we identified the production of {sup 188–189–191–195}Pt, {sup 191–192–193–194–195–196}Au and {sup 186–188–189–190–192–194–189–190–192–194}Ir. For example, at the lower energies (53 and 65MeV), we measured {sup 191}Pt production cross-sections of 144mb and 157mb. Considerable care was needed in following the process of dissolving and diluting the samples to get consistent results. The new LARA array will help us better ascertain the absolute efficiency of the counting system and more reliable production cross-sections. Conclusion: Modern HPGe spectroscopic techniques provide enhanced sensitivity, promising precise quantification of the quality of radioisotopes used in medical physics. Using new decay information may have non-trivial impact on treatment planning and dose-assessment.

07 ISOTOPE AND RADIATION SOURCES↗

Variation of lead isotopic composition and atomic weight in terrestrial materials (IUPAC Technical Report)

The isotopic composition and atomic weight of lead are variable in terrestrial materials because its three heaviest stable isotopes are stable end-products of the radioactive decay of uranium ( 238 U to 206 Pb; 235 U to 207 Pb) and thorium ( 232 Th to 208 Pb). The lightest stable isotope, 204 Pb, is primordial. These variations in isotope ratios and atomic weights provide useful information in many areas of science, including geochronology, archaeology, environmental studies, and forensic science. While elemental lead can serve as an abundant and homogeneous isotopic reference, deviations from the isotope ratios in other lead occurrences limit the accuracy with which a standard atomic weight can be given for lead. In a comprehensive review of several hundred publications and analyses of more than 8000 samples, published isotope data indicate that the lowest reported lead atomic weight of a normal terrestrial materials is 206.1462 ± 0.0028 (k = 2), determined for a growth of the phosphate mineral monazite around a garnet relic from an Archean high-grade metamorphic terrain in north-western Scotland, which contains mostly 206 Pb and almost no 204 Pb. The highest published lead atomic weight is 207.9351 ± 0.0005 (k = 2) for monazite from a micro-inclusion in a garnet relic, also from a high-grade metamorphic terrain in north-western Scotland, which contains almost pure radiogenic 208 Pb. When expressed as an interval, the lead atomic weight is [206.14, 207.94]. It is proposed that a value of 207.2 be adopted for the single lead atomic-weight value for education, commerce, and industry, corresponding to previously published conventional atomic-weight values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

California GAMA Special Study: Stable Isotopic Composition of Boron in Groundwater - San Diego County Domestic Well Data

The Groundwater Ambient Monitoring and Assessment (GAMA) Program is a comprehensive groundwater quality monitoring program for the state of California. Managed by the California State Water Resources Control Board (SWRCB), the goals of the Program are twofold: to improve statewide groundwater monitoring, and to increase the availability of groundwater quality information to the public. The Domestic Well Project has sampled 137 wells in San Diego County in an effort to assess the quality of these unregulated domestic use water sources. Lawrence Livermore National Laboratory (LLNL) performed isotopic analyses of domestic well water samples for the SWRCB; this study summarizes the results of measurements of the isotopic composition of dissolved boron in groundwater in 56 wells, and provides some interpretations regarding the significance of these findings. These data, in conjunction with water and nitrate isotopic composition data (Singleton et al., 2010), are useful for determining the source(s) of nitrate in potentially-contaminated San Diego County groundwater reservoirs. The isotopic composition of dissolved boron (δ 11 B) in sampled San Diego County groundwaters varies from -0.8 to +64.4 ‰. Most sampled groundwaters (44 of 56) have δ 11 B values between +20 and +50 ‰, within the isotopic composition range characteristic of animal manure. These samples tend to have high nitrate concentrations (>50 mg/L as NO 3 ) These results are consistent with isotopic composition of nitrogen in nitrate (δ 15 N) data from Singleton et al. (2010), indicating that animal manure is a primary source of nitrate in most groundwaters measured in this study. Seven samples have δ 11 B values less than +20 ‰, outside of the animal manure δ 11 B range. These groundwaters tend to have low nitrate concentrations(<10 mg/L as NO 3 ), although two have nitrate concentrations greater than 10 mg/L, suggesting that wastewater may partially contribute to their nitrate budget. No samples measured in this study have boron or nitrate isotopic compositions consistent with a mineral fertilizer nitrate source. Five sampled groundwaters have δ 11 B values greater than +50 ‰, significantly higher than any known anthropogenic boron source. More work is needed to assess the source of nitrate and boron in the greater than +50 ‰ groundwaters.

07 ISOTOPE AND RADIATION SOURCES↗

SRF Resonators for a bi-directional Energy Ramping Upgrade of the Isotope Production Facility Beamline at LANL

The LANL Isotope Production Facility (IPF) is one of the two high-current proton linear accelerators operated under the auspices of the DOE Office of Nuclear Physics Isotope Development and Production for Research Applications Program. The IPF beamline operates with a fixed 100-MeV energy proton beam, diverted from the LANSCE accelerator and guided towards the isotope production target station. The fixed beam energy limits the number of isotopes that can be produced at IPF, and adversely affects the purity of isotopes produced at non-optimal energies. In particular, the IPF program is receiving increasing numbers of requests for high purity isotopes such as Np-236 (national security applications) and Re-186 (medical therapy). These are typically produced via (p,n) and (p,2n) nuclear reactions, requiring very tight control of the incident energies on the production targets to ensure an end product with a high radionuclidic purity. It is well known that this level of energy control cannot be achieved when a 100 MeV beam of mono-energetic protons is degraded to the required energies, typically below 30 MeV, as too much energy spread is acquired. Operating the IPF beamline at lower, mono-energetic beam energies such as at 40 MeV will allow the required tight energy control in target assemblies to ensure a high purity product. In addition, NP has requested a LANL/BNL/ORNL collaboration focus on establishing a national large-scale production capability for the therapy isotope Ac-225. Recent nuclear cross section measurements done at LANL show that due to a steep rise in production cross section towards higher proton energies (See Figure 2), proton beams at energies substantially greater than 100 MeV will be highly beneficial for Ac-225 production [AC255]. Such higher-energy beams cannot be delivered to IPF at present. Lower-energy beams (70 MeV and 40 MeV) can be delivered but only in sole-use mode; all other LANSCE users must be offline during 70 MeV or 40 MeV operation.

07 ISOTOPE AND RADIATION SOURCES↗

Diffusion of Oxygen Isotopes in Thermally Evolving Planetesimals and Size Ranges of Presolar Silicate Grains

Presolar grains are small particles found in meteorites through their isotopic compositions, which are considerably different from those of materials in the solar system. If some isotopes in presolar grains diffused out beyond their grain sizes when they were embedded in parent bodies of meteorites, their isotopic compositions could be washed out, and hence the grains could no longer be identified as presolar grains. We explore this possibility for the first time by self-consistently simulating the thermal evolution of planetesimals and the diffusion length of {sup 18}O in presolar silicate grains. Our results show that presolar silicate grains smaller than ∼0.03 μ m cannot keep their original isotopic compositions even if the host planetesimals experienced a maximum temperature as low as 600 °C. Since this temperature corresponds to that experienced by petrologic type 3 chondrites, isotopic diffusion can constrain the size of presolar silicate grains discovered in such chondrites to be larger than ∼0.03 μ m. We also find that the diffusion length of {sup 18}O reaches ∼0.3–2 μ m in planetesimals that were heated up to 700–800°C. This indicates that, if the original size of presolar grains spans a range from ∼0.001 μ m to ∼0.3 μ m like that in the interstellar medium, then the isotopic records of the presolar grains may be almost completely lost in such highly thermalized parent bodies. We propose that isotopic diffusion could be a key process to control the size distribution and abundance of presolar grains in some types of chondrites.

79 ASTRONOMY AND ASTROPHYSICS↗

Ion implantation system and process for ultrasensitive determination of target isotopes

A system and process are disclosed for ultrasensitive determination of target isotopes of analytical interest in a sample. Target isotopes may be implanted in an implant area on a high-purity substrate to pre-concentrate the target isotopes free of contaminants. A known quantity of a tracer isotope may also be implanted. Target isotopes and tracer isotopes may be determined in a mass spectrometer. The present invention provides ultrasensitive determination of target isotopes in the sample.

07 ISOTOPE AND RADIATION SOURCES↗

LANL-IPF responses to isotopes workshop background information survey

Responses to the following are provided: (A) Which isotopes do you (company, agency, university, community) currently use in your activities or distribute (repackage) to end-users? (B) Describe generally what these isotopes are used for, i.e. the science or application. (C) Which isotope(s) do you anticipate may have significant future increase in demand. Identify the isotope(s), its priority, possible chemical form and for what purpose it would be used. (D) Are there other isotopes that you might use but are currently unavilable or not available in difficient quantities? If so, please identify this isotope, from whom have you tired to obtain it and for what prupose would it be used. (E) Do you have any specific issues with respect to the purity, availability, reliability of supply, etc. of isotopes at present?

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Origin of the isotopic composition of natural perchlorate: Experimental results for the impact of reaction pathway and initial ClO x reactant

Natural perchlorate (ClO 4 - ) exists in many places on Earth, in lunar regolith, meteorites, and on the surface of Mars. Terrestrial natural ClO 4 - has widely variable Cl and O stable isotopic compositions (δ 37 Cl, δ 18 O, Δ 17 O). The δ 18 O and Δ 17 O values of ClO 4 - from the most hyper-arid locations co-vary. ClO 4 - from less arid areas has relatively little 17 O excess and poor Δ 17 O-δ 18 O correlation. ClO 4 - from the Atacama Desert has unusually low δ 37 Cl (<-10‰) and exhibits a positive correlation between δ 37 Cl and δ 18 O, while the δ 37 Cl of ClO 4 - from all other locations varies between -5 and +7‰ with no δ 37 Cl-δ 18 O covariation. To evaluate the impact of different precursors (ClO x ) and reaction pathways on the isotopic composition of ClO 4 - , we measured the isotopic composition of ClO 4 - produced in the laboratory by UV or O 3 mediated aqueous oxidation of Cl-, OCl-, ClO2-, and ClO2° as well as O 3 mediated oxidation of dry NaCl. ClO x oxidation in aqueous or dry systems enriched in O 3 produced ClO 4 - with Δ 17 O values that generally increased with the number of O atoms required and included evidence that the site-specific 17 O anomaly in O 3 was preferentially transferred to ClO 4 - . Based on the inferred number of O atoms sourced from O 3 , and known Cl and O reaction pathways, it appears that ClO 2 ° and ClO 3 * were required intermediates in the production of ClO 4 - in the O 3 experiments. ClO x aqueous oxidation by UV irradiation produced ClO 4 - with a large range of δ 18 O values and little or no 17 O anomaly. ClO 3 - was produced to a much greater extent than ClO 4 - in all experiments except dry oxidation of NaCl by O 3 . The isotopic composition of ClO 3 - was distinct from that of ClO 4 - produced from the same initial reactants. Combined results of O 3 and UV mediated reactions largely bracketed the range of natural ClO 4 - δ 18 O and Δ 17 O values as well as δ 37 Cl values of non-Atacama natural samples, but no conditions produced the low δ 37 Cl values of Atacama ClO 4 - . Finally, our results indicate that variation in production mechanisms, possibly combined with isotopically variable precursors, could be responsible for much of the observed isotopic variation in natural ClO 4 - and ClO 3 - .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Power law behavior of the isotope yield distributions in the multifragmentation regime of heavy ion reactions

Isotope yield distributions in the multifragmentation regime were studied with high-quality isotope identification, focusing on the intermediate mass fragments (IMFs) produced in semiviolent collisions. The yields were analyzed within the framework of a modified Fisher model. Using the ratio of the mass-dependent symmetry energy coefficient relative to the temperature, a{sub sym}/T, extracted in previous work and that of the pairing term, a{sub p}/T, extracted from this work, and assuming that both reflect secondary decay processes, the experimentally observed isotope yields were corrected for these effects. For a given I=N-Z value, the corrected yields of isotopes relative to the yield of {sup 12}C show a power law distribution Y(N,Z)/Y({sup 12}C){approx}A{sup -}{tau} in the mass range 1{<=}A{<=}30, and the distributions are almost identical for the different reactions studied. The observed power law distributions change systematically when I of the isotopes changes and the extracted {tau} value decreases from 3.9 to 1.0 as I increases from -1 to 3. These observations are well reproduced by a simple deexcitation model, with which the power law distribution of the primary isotopes is determined to be {tau}{sup prim}=2.4{+-}0.2, suggesting that the disassembling system at the time of the fragment formation is indeed at, or very near, the critical point.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Stable Isotope Fractionation by Transport and Transformation

Of the 92 elements naturally present on modern Earth, only 21 are monotopic. The remainder are composed of multiple isotopes, many of which are either stable or decay over such extraordinarily long timescales that they may be considered effectively stable for appropriate applications. Additionally,these isotopes of a given element are distinguished by the number of neutrons within their nucleus, resulting in subtle differences in mass. Though most fundamental characteristics of the isotopes of a given element are the same (e.g., charge, atomic number), their relative distributions in natural environments are altered as they are subjected to a range of mass- dependent transport and transformation processes. Urey and colleagues first demonstrated this mass-dependent partitioning within a thermodynamic framework (Urey 1947). Decades later, these small differences in isotopic abundances serve as the foundation for a suite of powerful diagnostic tools applied broadly across the Earth Sciences, constituting essential capabilities within the disciplines of hydrology, oceanography, petrology, paleoclimate, planetary science, paleontology, ecology, and microbiology, among others. In the following chapter, we review multiple pathways of isotopic fractionation and their treatment within numerical reactive transport frameworks. We focus on near-surface hydrologic systems hosting a variety of water–rock–life interactions which reflect a fundamental balance between transport and transformation. Such conditions describe a wide variety of environments, ranging from the cycling of water through terrestrial ecosystems, to the burial of carbonates in marine sediments, to the metabolism of microbes. We begin with consideration of simple fractionation in the absence of transport, followed by sequential addition of common transport influences with an emphasis on the unique information contained within isotopic observations in these systems. Lastly, we turn to more ‘complex’ reactive pathways that are not easily described by single unidirectional conversions.

54 ENVIRONMENTAL SCIENCES↗

A Novel Framework for Quantifying past Methane Recycling by Sphagnum-Methanotroph Symbiosis Using Carbon and Hydrogen Isotope Ratios of Leaf Wax Biomarkers

The concentration of atmospheric methane is strongly linked to variations in Earth's climate. Currently, we can directly reconstruct the total atmospheric concentration of methane, but not individual terms of the methane cycle. Northern wetlands, dominated by Sphagnum, are an important contributor of atmospheric methane, and we seek to understand the methane cycle in these systems. We present a novel method for quantifying the proportion of carbon Sphagnum assimilates from its methanotrophic symbionts using stable isotope ratios of leaf-wax biomarkers. Carbon isotope ratios of Sphagnum compounds are determined by two competing influences, water content and the isotope ratio of source carbon. We disentangled these effects using a combined hydrogen and carbon isotope approach. We constrained Sphagnum water content using the contrast between the hydrogen isotope ratios of Sphagnum and vascular plant biomarkers. We then used Sphagnum water content to calculate the carbon isotope ratio of Sphagnum's carbon pool. Using a mass balance equation, we calculated the proportion of recycled methane contributed to the Sphagnum carbon pool, 'PRM.' We quantified PRM in peat monoliths from three microhabitats in the Mer Bleue peatland complex. Modern studies have shown that water table depth and vegetation have strong influences on the peatland methane cycle on instrumental time scales. With this new approach, delta C-13 of Sphagnum compounds are now a useful tool for investigating the relationships among hydrology, vegetation, and methanotrophy in Sphagnum peatlands over the time scales of entire peatland sediment records, vital to our understanding of the global carbon cycle through the Late Glacial and Holocene.

air pollution↗

Isotopic evidence for the infiltration of mantle and metamorphic CO2-H2O fluids from below in faulted rocks from the San Andreas Fault System

To characterize the origin of the fluids involved in the San Andreas Fault (SAF) system, we carried out an isotope study of exhumed faulted rocks from deformation zones, vein fillings and their hosts and the fluid inclusions associated with these materials. Samples were collected from segments along the SAF system selected to provide a depth profile from upper to lower crust. In all, 75 samples from various structures and lithologies from 13 localities were analyzed for noble gas, carbon, and oxygen isotope compositions. Fluid inclusions exhibit helium isotope ratios ({sup 3}He/{sup 4}He) of 0.1-2.5 times the ratio in air, indicating that past fluids percolating through the SAF system contained mantle helium contributions of at least 35%, similar to what has been measured in present-day ground waters associated with the fault (Kennedy et al., 1997). Calcite is the predominant vein mineral and is a common accessory mineral in deformation zones. A systematic variation of C- and O-isotope compositions of carbonates from veins, deformation zones and their hosts suggests percolation by external fluids of similar compositions and origin with the amount of fluid infiltration increasing from host rocks to vein to deformation zones. The isotopic trend observed for carbonates in veins and deformation zones follows that shown by carbonates in host limestones, marbles, and other host rocks, increasing with increasing contribution of deep metamorphic crustal volatiles. At each crustal level, the composition of the infiltrating fluids is thus buffered by deeper metamorphic sources. A negative correlation between calcite {delta}{sup 13}C and fluid inclusion {sup 3}He/{sup 4}He is consistent with a mantle origin for a fraction of the infiltrating CO{sub 2}. Noble gas and stable isotope systematics show consistent evidence for the involvement of mantle-derived fluids combined with infiltration of deep metamorphic H{sub 2}O and CO{sub 2} in faulting, supporting the involvement of deep fluids percolating through and perhaps weakening the fault zone. There is no clear evidence for a significant contribution from meteoric water, except for overprinting related to late weathering.

54 ENVIRONMENTAL SCIENCES↗

Stable Isotope Enrichment Capabilities at ORNL

The Oak Ridge National Laboratory (ORNL) and the US Department of Energy Nuclear Physics Program have built a high-resolution Electromagnetic Isotope Separator (EMIS) as a prototype for reestablishing a US based enrichment capability for stable isotopes. ORNL has over 60 years of experience providing enriched stable isotopes and related technical services to the international accelerator target community, as well as medical, research, industrial, national security, and other communities. ORNL is investigating the combined use of electromagnetic and gas centrifuge isotope separation technologies to provide research quantities (milligram to several kilograms) of enriched stable isotopes. In preparation for implementing a larger scale production facility, a 10 mA high-resolution EMIS prototype has been built and tested. Initial testing of the device has simultaneously collected greater than 98% enriched samples of all the molybdenum isotopes from natural abundance feedstock.

calutron↗

Isotope Enrichment Detection by Laser Ablation - Dual Tunable Diode Laser Absorption Spectrometry

The rapid global expansion of nuclear energy is motivating the expedited development of new safeguards technology to mitigate potential proliferation threats arising from monitoring gaps within the uranium enrichment process. Current onsite enrichment level monitoring methods are limited by poor sensitivity and accuracy performance. Offsite analysis has better performance, but this approach requires onsite hand sampling followed by time-consuming and costly post analysis. These limitations make it extremely difficult to implement comprehensive safeguards accounting measures that can effectively counter enrichment facility misuse. In addition, uranium enrichment by modern centrifugation leads to a significant proliferation threat, since the centrifuge cascades can quickly produce a significant quantity of highly enriched uranium (HEU). The Pacific Northwest National Laboratory is developing an engineered safeguards approach having continuous aerosol particulate collection and uranium isotope analysis to provide timely detection of HEU production in a low enriched uranium facility. This approach is based on laser vaporization of aerosol particulate samples, followed by wavelength tuned laser diode spectroscopy, to characterize the 235U/238U isotopic ratio by subtle differences in atomic absorption wavelengths arising from differences in each isotope’s nuclear mass, volume, and spin (hyperfine structure for 235U). Environmental sampling media is introduced into a small, reduced pressure chamber, where a focused pulsed laser vaporizes a 10 to 20-µm sample diameter. The ejected plasma forms a plume of atomic vapor. A plume for a sample containing uranium has atoms of the 235U and 238U isotopes present. Tunable diode lasers are directed through the plume to selectively excite each isotope and their presence is detected by monitoring absorbance signals on a shot-to-shot basis. Single-shot detection sensitivity approaching the femtogram range and abundance uncertainty less than 10% have been demonstrated with measurements on surrogate materials. In this paper we present measurement results on samples containing background materials (e.g., dust, minerals, soils) laced with micron-sized target particles having isotopic ratios ranging from 1 to 50%.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Kinetic isotope effects significantly influence intracellular metabolite 13 C labeling patterns and flux determination

Rigorous mathematical modeling of carbon-labeling experiments allows estimation of fluxes through the pathways of central carbon metabolism, yielding powerful information for basic scientific studies as well as for a wide range of applications. However, the mathematical models that have been developed for flux determination from 13 C labeling data have commonly neglected the influence of kinetic isotope effects on the distribution of 13 C label in intracellular metabolites, as these effects have often been assumed to be inconsequential. We have used measurements of the 13 C isotope effects on the pyruvate dehydrogenase enzyme from the literature to model isotopic fractionation at the pyruvate node and quantify the modeling errors expected to result from the assumption that isotope effects are negligible. We show that under some conditions kinetic isotope effects have a significant impact on the 13 C labeling patterns of intracellular metabolites, and the errors associated with neglecting isotope effects in 13 C-metabolic flux analysis models can be comparable in size to measurement errors associated with GC–MS. Thus, kinetic isotope effects must be considered in any rigorous assessment of errors in 13 C labeling data, goodness-of-fit between model and data, confidence intervals of estimated metabolic fluxes, and statistical significance of differences between estimated metabolic flux distributions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗