Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Computational Investigation of the Near-Field Plasma Plume in Ion-Ion Propulsion

A two-fluid numerical model of plasma flows was developed to investigate the plume of an ion-ion propulsion system. The densities of positive and negative ions, and the associated values of net charge, electric field, and electric potential were calculated as a function of time throughout the domain. The computational domain was chosen to be large enough (25 thruster diameters downstream of the exit plane) to allow for examining the neutralization of the plume. The resulting plasma electric potential and charge neutrality at the downstream end of the domain are shown and they indicate that it is possible to alternatively accelerate oppositely charged ions without the need for an electron-emitting neutralizer and without facing any electric potential hills that could cause stagnation. However, compared to existing literature on ion-ion plasma thrusters, the results from this simulation predict a longer length-scale for voltage decay.

Sankaran, K.↗

Ion Production and Transport in Atmospheric Pressure Ion Source Mass Spectrometers (Final Report)

This document is the final report on a project that focused in the general theme of atmospheric-pressure ion production and transport for mass spectrometry. Within that general theme there were two main projects: the fundamental study of the transport of elemental ions through the vacuum interface of an inductively coupled plasma mass spectrometer (ICPMS), and fundamental studies of the ionization mechanisms in ambient desorption/ionization (ADI) sources for molecular mass spectrometry. In both cases the goal was to generate fundamental understanding of key instrumental processes that would lead to the development of instruments that were more sensitive and more consistent in their performance. The emphasis on consistency derives from the need for instruments that have the same sensitivity, regardless of sample type. In the jargon of analytical chemistry, such instruments are said to be free from matrix effects. In the ICPMS work each stage of ion production and of ion transport from the atmospheric pressure to the high-vacuum mass analyzer was studied. Factors controlling ion transport efficiency and consistency were identified at each stage of pressure reduction. In the ADI work the interactions between an electrospray plume and a fluorescent sample on a surface were examined microscopically. A new mechanism for analyte ion production in desorption electrospray ionization (DESI) was proposed. Optical spectroscopy was used to track the production of reactive species in plasmas used as ADI sources. Experiments with mixed-gas plasmas demonstrated that the addition of a small amount of hydrogen to a helium ADI plasma could boost the sensitivity for some analytes by over an order of magnitude.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and Beam Dynamics Studies of a Multi-Ion Linac Injector for the JLEIC Ion Complex

The electron-ion collider (JLEIC) being proposed at JLab requires a new ion accelerator complex which includes a linac capable of delivering any ion beam from hydrogen to lead to the booster. We are currently developing a linac which consists of several ion sources, a normal conducting (NC) front end, up to 5 MeV/u, and a SC section for energies > 5 MeV/u. This design work is focused on the beam dynamics and electrodynamics studies performed to design efficient and cost-effective accelerating structures for both the NC and SC sections of the linac. Currently, we are considering two separate RFQs for the heavy-ion and light-ion beams including polarized beams, and different types of NC accelerating structures downstream of the RFQ. Quarter-wave and half-wave resonators can be effectively used in the SC section.

Ostroumov, P. N.↗

Anode for sodium-ion and potassium-ion batteries

A first method for fabricating an anode for use in sodium-ion and potassium-ion batteries includes mixing a conductive carbon material having a low surface area, a hard carbon material, and a binder material. A carbon-composite material is thus formed and coated on a conductive substrate. A second method for fabricating an anode for use in sodium-ion and potassium-ion batteries mixes a metal-containing material, a hard carbon material, and binder material. A carbon-composite material is thus formed and coated on a conductive substrate. A third method for fabricating an anode for use in sodium-ion and potassium-ion batteries provides a hard carbon material having a pyrolyzed polymer coating that is mixed with a binder material to form a carbon-composite material, which is coated on a conductive substrate. Descriptions of the anodes and batteries formed by the above-described methods are also provided.

25 ENERGY STORAGE↗

Electrically regenerated ion-exchange technology: Leveraging faradaic reactions and assessing the effect of co-ion sorption

Capacitive deionization (CDI) technologies have the potential to become cost-competitive alternatives to reverse osmosis for the treatment of brackish waters. In this study, we describe our findings on the effect of co-ion sorption and faradaic side reactions on our ion exchange resin functionalized desalination electrodes which passively capture salt and reject it upon charging. This system, which we previously reported on and refer to as electrically regenerated ion exchange (ERI), avoids the use of expensive ion exchange membranes in an effort to save costs. Surprisingly, we find that, compared to a reference CDI system, ERI electrodes capture salt most effectively at low applied voltages (0.5 mg/cm 3 at 0.8 V). Both CDI and ERI systems also seem to suffer from co-ion sorption effects which negatively impact salt adsorption. However, Faradaic side reactions at higher voltages (1 V and 1.2 V) which we track via pH measurements, serve as a detriment to CDI but seem to facilitate the functionality of ERI.

42 ENGINEERING↗

Laser ion source for heavy ion inertial fusion

The proposed heavy ion inertial fusion (HIF) scenarios require ampere class low charge state ion beams of heavy species. A laser ion source (LIS) is recognized as one of the promising candidates of ion beam providers, since it can deliver high brightness heavy ion beams to accelerators. A design of LIS for the HIF depends on the accelerator structure and accelerator complex following the source. In this article, we discuss the specifications and design of an appropriate LIS assuming two major types of the accelerators: radio frequency (RF) high quality factor cavity type and non-resonant induction core type. We believe that a properly designed LIS satisfies the requirements of both types, however some issues need to be verified experimentally.

43 PARTICLE ACCELERATORS↗

High-Capacity Aqueous Storage in Vanadate Cathodes Promoted by the Zn-Ion and Proton Intercalation and Conversion–Intercalation of Vanadyl Ions

Aqueous Zn-ion batteries (AZIBs) are promising alternatives to lithium-ion batteries in stationary storage. However, limited storage capacity and cyclic life impede their large-scale implementation. In this study, we report reversible electrochemical insertion of multi-ions into sodium vanadate (NaV 3 O 8 ) cathode materials for AZIBs, achieving a maximum storage capacity of 450 mAh g –1 at 0.05 A g –1 and a capacity retention of 82% after 500 cycles at 0.4 A g –1 . In addition to Zn 2+ and H + insertion, in situ X-ray diffraction (XRD) and X-ray absorption spectroscopy (XAS) collectively provide explicit evidence on vanadyl ions (VO 2+ ) conversion–intercalation at the NaV 3 O 8 cathode, showing the deintercalation of VO 2+ from NaV 3 O 8 and the consequent conversion of VO 2+ into V 2 O 5 on charging, and vice versa on discharging. Our study is the first to report on the cation conversion–intercalation mechanism in AZIBs. This reversible multi-ion storage mechanism provides a design principle for developing high-capacity aqueous electrode materials by engaging both the intercalation and conversion of charge carriers.

25 ENERGY STORAGE↗

Dynamic time-warping correction for shifts in ultrahigh resolving power ion mobility spectrometry and structures for lossless ion manipulations

Detection of arrival time shifts between ion mobility spectrometry (IMS) separations can limit achievable resolving power (Rp), particularly when multiple separations are summed or averaged, as commonly practiced. Such variations are more apparent in higher Rp measurements, and are particularly evident in long path length traveling wave structures for lossless ion manipulations (SLIM) IMS due to their typically much longer separation times. Here we explore the utility of a data processing approaches employing linear alignment (LA) and nonlinear dynamic time warping (DTW) of IMS separations to correct for variations between separations, such as due to pressure fluctuations. For multipass SLIM IMS separations, where narrow mobility range measurements have arrival times that can extend to several seconds, the LA approach effectively corrected for such variations, and significantly improvement Rp for summed separations. However, LA was much less effective for high Rp broad mobility range separations, such as obtained with multilevel SLIM IMS. Changes in IMS arrival times ions were observed to be correlated with small pressure changes, with approximately 0.6% relative arrival time shifts being common, sufficient to result in a loss of Rp for summed separations. Comparison of the approaches showed DTW alignment performed similarly to LA when used over a narrow mobility range, but was significantly better (providing narrower peaks and higher signal intensities) for wide mobility range data. We found the DTW approach increased Rp by as much as 115% for measurements in which 50 IMS separations over 2 seconds were summed, and leading to a large improvement in effective Rp. We conclude that DTW is superior to LA for ultrahigh resolution broad mobility range SLIM IMS separations, correcting for ion arrival time shifts regardless of the cause. Our tool is publicly available for use with universal ion mobility format (.UIMF) and text (.txt) files.

Data alignment, dynamic time warping, ion mobility↗

Development of a Kingdon ion trap system for trapping externally injected highly charged ions

We have developed a Kingdon ion trap system for the purpose of the laboratory observation of the x-ray forbidden transitions of highly charged ions (HCIs). Externally injected Ar{sup q+} (q = 5–7) with kinetic energies of 6q keV were successfully trapped in the ion trap. The energy distribution of trapped ions is discussed in detail on the basis of numerical simulations. The combination of the Kingdon ion trap and the time-of-flight mass spectrometer enabled us to measure precise trapping lifetimes of HCIs. As a performance test of the instrument, we measured trapping lifetimes of Ar{sup q+} (q = 5–7) under a constant number density of H₂ and determined the charge-transfer cross sections of Ar{sup q+}(q = 5, 6)-H₂ collision systems at binary collision energies of a few eV. It was confirmed that the present cross section data are consistent with previous data and the values estimated by some scaling formula.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Runaway of energetic test ions in a toroidal plasma

Ion runaway in the presence of a large-scale, reconnection-driven electric field has been conclusively measured in the Madison Symmetric Torus reversed-field pinch (RFP). Measurements of the acceleration of a beam of fast ions agree well with test particle and Fokker-Planck modeling of the runaway process. However, the runaway mechanism does not explain all measured ion heating in the RFP, particularly previous measurements of strong perpendicular heating. It is likely that multiple energization mechanisms occur simultaneously and with differing significance for magnetically coupled thermal ions and magnetically decoupled tail and beam ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Defocusing of an ion beam propagating in background plasma due to two-stream instability

The current and charge neutralization of charged particle beams by background plasma enable ballistic beam propagation and have a wide range of applications in inertial fusion and high energy density physics. However, the beam-plasma interaction can result in the development of collective instabilities that may have deleterious effects on ballistic propagation of an ion beam. In the case of fast, light-ion beams, non-linear fields created by instabilities can lead to significant defocusing of the beam. We study an ion beam pulse propagating in a background plasma, which is subjected to two-stream instability between the beam ions and plasma electrons, using PIC code LSP. The defocusing effects of the instability on the beam can be much more pronounced in small radius beams. We show through simulations that a beamlet produced from an ion beam passed through an aperture can be used as a diagnostic tool to identify the presence of the two-stream instability and quantify its defocusing effects. The effect can be observed on the Neutralized Drift Compression Experiment-II facility by measuring the spot size of the extracted beamlet propagating through several meters of plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Selective deuterium ion acceleration using the Vulcan petawatt laser

We report on the successful demonstration of selective acceleration of deuterium ions by target-normal sheath acceleration (TNSA) with a high-energy petawatt laser. TNSA typically produces a multi-species ion beam that originates from the intrinsic hydrocarbon and water vapor contaminants on the target surface. Using the method first developed by Morrison et al. [Phys. Plasmas 19, 030707 (2012)], an ion beam with >99% deuterium ions and peak energy 14 MeV/nucleon is produced with a 200 J, 700 fs, >10{sup 20}W/cm{sup 2} laser pulse by cryogenically freezing heavy water (D{sub 2}O) vapor onto the rear surface of the target prior to the shot. Within the range of our detectors (0°–8.5°), we find laser-to-deuterium-ion energy conversion efficiency of 4.3% above 0.7 MeV/nucleon while a conservative estimate of the total beam gives a conversion efficiency of 9.4%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a pepper-pot emittance meter for diagnostics of low-energy multiply charged heavy ion beams extracted from an ECR ion source

Several fluorescent materials were tested for use in the imaging screen of a pepper-pot emittance meter that is suitable for investigating the beam dynamics of multiply charged heavy ions extracted from an ECR ion source. SiO{sub 2} (quartz), KBr, Eu-doped CaF{sub 2}, and Tl-doped CsI crystals were first irradiated with 6.52-keV protons to determine the effects of radiation damage on their fluorescence emission properties. For such a low-energy proton beam, only the quartz was found to be a suitable fluorescent material, since the other materials suffered a decay in fluorescence intensity with irradiation time. Subsequently, quartz was irradiated with heavy {sup 12}C{sup 4+}, {sup 16}O{sup 4+}, and {sup 40}Ar{sup 11+} ions, but it was found that the fluorescence intensity decreased too rapidly to measure the emittance of these heavy-ion beams. These results suggest that a different energy loss mechanism occurs for heavier ions and for protons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrical-thermal-structural finite element simulation and experimental study of a plasma ion source for the production of radioactive ion beams

The production target and the ion source constitute the core of the selective production of exotic species (SPES) facility. In this complex experimental apparatus for the production of radioactive ion beams, a 40 MeV, 200 μA proton beam directly impinges a uranium carbide target, generating approximately 10{sup 13} fissions per second. The transfer line enables the unstable isotopes generated by the {sup 238}U fissions in the target to reach the ion source, where they can be ionized and finally accelerated to the subsequent areas of the facility. In this work, the plasma ion source currently adopted for the SPES facility is analyzed in detail by means of electrical, thermal, and structural numerical models. Next, theoretical results are compared with the electric potential difference, temperature, and displacement measurements. Experimental tests with stable ion beams are also presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distinct regions that control ion selectivity and calcium-dependent activation in the bestrophin ion channel

Cytoplasmic calcium (Ca 2+ ) activates the bestrophin anion channel, allowing chloride ions to flow down their electrochemical gradient. Mutations in bestrophin 1 (BEST1) cause macular degenerative disorders. Previously, we determined an X-ray structure of chicken BEST1 that revealed the architecture of the channel. Here, we present electrophysiological studies of purified wild-type and mutant BEST1 channels and an X-ray structure of a Ca 2+ -independent mutant. From these experiments, we identify regions of BEST1 responsible for Ca 2+ activation and ion selectivity. A “Ca 2+ clasp” within the channel’s intracellular region acts as a sensor of cytoplasmic Ca 2+ . Alanine substitutions within a hydrophobic “neck” of the pore, which widen it, cause the channel to be constitutively active, irrespective of Ca 2+ . We conclude that the primary function of the neck is as a “gate” that controls chloride permeation in a Ca 2+ -dependent manner. In contrast to what others have proposed, we find that the neck is not a major contributor to the channel’s ion selectivity. We find that mutation of a cytosolic “aperture” of the pore does not perturb the Ca 2+ dependence of the channel or its preference for anions over cations, but its mutation dramatically alters relative permeabilities among anions. The data suggest that the aperture functions as a size-selective filter that permits the passage of small entities such as partially dehydrated chloride ions while excluding larger molecules such as amino acids. Furthermore, unlike ion channels that have a single “selectivity filter,” in bestrophin, distinct regions of the pore govern anion-vs.-cation selectivity and the relative permeabilities among anions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dependence of ion-cyclotron range of frequencies instabilities on species mix and fast-ion distribution: I. Stability

Ion cyclotron emission (ICE) driven by fast ions has the potential to be a reactor relevant diagnostic of confined and escaping fast ions; moreover, controlled experiments in magnetic fusion devices can shed light on similar magnetospheric instabilities below and above the ion cyclotron frequency f ci . Dedicated DIII-D experiments studied instabilities below f ci and at cyclotron harmonics l f ci by injecting thirteen different neutral beam populations into plasmas with different thermal compositions of H, D, and 3He at five different values of toroidal field. High-frequency magnetic loops diagnose mode properties. Each beam type is individually injected for an approximate slowing-down time (~100 ms), resulting in a database of 2529 conditions that are analyzed in frequency bands corresponding to ICE harmonics and < f ci global Alfvén eigenmodes. The sub-cyclotron modes are more unstable at low field and in plasmas with large H concentration. For D injection, first harmonic ICE at f cD is more unstable in hydrogen plasmas but, for H injection, the converse is true (ICE at f cH is more unstable in D), suggesting that thermal same-species ions damp fundamental ICE. ICE stability also depends upon the pitch-angle anisotropy gradient and upon the ‘bump-on-tail’ gradient ∂f/∂v. Although the frequency of unstable ICE in these plasmas always occurs near the central cyclotron frequency, the precise value also depends on the Alfvén speed and beam direction, consistent with the idea that instability occurs for modes that simultaneously satisfy ω ≃ 2πlf ci , the magnetosonic dispersion relation, and the Doppler-shifted resonance condition.

electromagnetic ion cyclotron instabilities↗

Dipole-Phonon Quantum Logic with Trapped Polar Molecular Ions

The interaction between the electric dipole moment of a trapped molecular ion and the phonon modes of the confined Coulomb crystal couples the orientation of the molecule to its motion. We consider the practical feasibility of harnessing this interaction to initialize, process, and read out quantum information encoded in molecular ion qubits without ever optically illuminating the molecules. We present two schemes wherein a molecular ion can be entangled with a cotrapped atomic ion qubit, providing, among other things, a means for molecular state preparation and measurement. Here, we also show that virtual phonon exchange can significantly boost the range of the intermolecular dipole-dipole interaction, allowing strong coupling between widely separated molecular ion qubits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Divalent cation and chloride ion sites of chicken acid sensing ion channel 1a elucidated by x-ray crystallography

Acid sensing ion channels (ASICs) are proton-gated ion channels that are members of the degenerin/epithelial sodium channel superfamily and are expressed throughout central and peripheral nervous systems. ASICs have been implicated in multiple physiological processes and are subject to numerous forms of endogenous and exogenous regulation that include modulation by Ca 2+ and Cl - ions. However, the mapping of ion binding sites as well as a structure-based understanding of the mechanisms underlying ionic modulation of ASICs have remained elusive. Here we present ion binding sites of chicken ASIC1a in resting and desensitized states at high and low pH, respectively, determined by anomalous diffraction x-ray crystallography. The acidic pocket serves as a nexus for divalent cation binding at both low and high pH, while we observe divalent cation binding within the central vestibule on the resting channel at high pH only. Moreover, neutralization of residues positioned to coordinate divalent cations via individual and combined Glu to Gln substitutions reduced, but did not extinguish, modulation of proton-dependent gating by Ca 2+ . Additionally, we demonstrate that anion binding at the canonical thumb domain site is state-dependent and present a previously undetected anion site at the mouth of the extracellular fenestrations on the resting channel. Our results map anion and cation sites on ASICs across multiple functional states, informing possible mechanisms of modulation and providing a blueprint for the design of therapeutics targeting ASICs.

59 BASIC BIOLOGICAL SCIENCES↗