Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTEGRAL DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Effect of Translational and Rotational Errors on Complex Dose Distributions With Off-Line and On-Line Position Verification

Purpose: To investigate the influence of translational and rotational errors on prostate intensity-modulated radiotherapy (IMRT) with an integrated boost to the tumor and to evaluate the effect of the use of an on-line correction protocol. Methods and Materials: For 19 patients, who had been treated with prostate IMRT and fiducial marker-based position verification, highly inhomogeneous IMRT plans, including an integrated tumor boost, were made using varying margins (2, 4, 6, and 8 mm). The measured translational and rotational errors were used to calculate the dose using two positioning strategies: an off-line and an on-line protocol to correct the translational shifts. The estimated dose to the targets and the organs at risk was compared with the intended dose. Results: Residual deviations after off-line correction led to statistically significant, but very small, reductions in dose coverage. Even when a 2-mm margin was used, the average reduction in dose to 99% of the volume was 1.4 {+-} 1.9 Gy for the tumor, 1.5 {+-} 1.5 Gy for the prostate without seminal vesicles (boost volume), and 4.3 {+-} 4.6 Gy, including the seminal vesicles (clinical target volume). Patients with large systematic rotational errors demonstrated a substantial decrease in dose, especially for the clinical target volume. If an on-line correction protocol was used, the average mean dose and dose to 99% of the volume of the targets improved. However, the extensive dose reduction for patients with large rotational errors barely recovered with on-line correction. Conclusion: For complex prostate IMRT with an integrated tumor boost, the use of an on-line correction protocol yields little improvement without the correction of rotational errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Response of Waveguide-Integrated Germanium-on-Silicon p-i-n Photodiodes to Neutron Displacement Damage

The effects of 14-MeV neutron displacement damage (DD) on waveguide-integrated germanium-on-silicon p-i-n photodiodes (PDs) for silicon photonics have been investigated up to fluences of 7.5×1012 n/cm2 (14 MeV), or 1.4×1013 n1-MeVeq/cm2(Si). The study includes measurements of dark current-voltage characteristics across temperature from 150-375 K, measurements of PD junction capacitance, spectral response measurements from 1260 nm to 1360 nm, and frequency response measurements. The devices are found to be susceptible to DD-induced carrier removal effects; however, they also continue to operate without meaningful impact to performance for the DD dose levels examined. Since the PD test chips include silicon photonic integrated grating couplers and waveguides which carry the optical signal to the PD, some assessment of the impact of DD on these passive devices can also be inferred. Finally, this work does not examine the short-term annealing or transient behavior of the DD, and instead has only considered the lasting damage that remains after any initial period of room temperature annealing.

42 ENGINEERING↗

SU-F-BRD-08: Guaranteed Epsilon-Optimal Treatment Plans with Minimum Number of Beams for SBRT Using RayStation

Purpose: To efficiently find quality-guaranteed treatment plans with the minimum number of beams for stereotactic body radiation therapy using RayStation. Methods: For a pre-specified pool of candidate beams we use RayStation (a treatment planning software for clinical use) to identify the deliverable plan which uses all the beams with the minimum dose to organs at risk (OARs) and dose to the tumor and other structures in specified ranges. Then use the dose matrix information for the generated apertures from RayStation to solve a linear program to find the ideal plan with the same objective and constraints allowing use of all beams. Finally we solve a mixed integer programming formulation of the beam angle optimization problem (BAO) with the objective of minimizing the number of beams while remaining in a predetermined epsilon-optimality of the ideal plan with respect to the dose to OARs. Since the treatment plan optimization is a multicriteria optimization problem, the planner can exploit the multicriteria optimization capability of RayStation to navigate the ideal dose distribution Pareto surface and select a plan of desired target coverage versus OARs sparing, and then use the proposed technique to reduce the number of beams while guaranteeing quality. For the numerical experiments two liver cases and one lung case with 33 non-coplanar beams are considered. Results: The ideal plan uses an impractically large number of beams. The proposed technique reduces the number of beams to the range of practical application (5 to 9 beams) while remaining in the epsilon-optimal range of 1% to 5% optimality gap. Conclusion: The proposed method can be integrated into a general algorithm for fast navigation of the ideal dose distribution Pareto surface and finding the treatment plan with the minimum number of beams, which corresponds to the delivery time, in epsilon-optimality range of the desired ideal plan. The project was supported by the Federal Share of program income earned by Massachusetts General Hospital on C06 CA059267, Proton Therapy Research and Treatment Center and partially by RaySearch Laboratories.

60 APPLIED LIFE SCIENCES↗

Integration of Corticospinal Tractography Reduces Motor Complications After Radiosurgery

Purpose: To evaluate whether the use of diffusion-tensor tractography (DTT) of the corticospinal tract could reduce motor complications after stereotactic radiosurgery (SRS). Methods and Materials: Patients with arteriovenous malformation (AVM) in the deep frontal lobe, deep parietal lobe, basal ganglia, and thalamus who had undergone radiosurgery since 2000 and were followed up for more than 3 years were studied. DTT of the corticospinal tract had been integrated into treatment planning of SRS since 2004, and the maximum dose received by the corticospinal tract was attempted to be less than 20 Gy. Treatment outcomes before (28 patients, Group A) and after (24 patients, Group B) the introduction of this technique were compared. Results: There were no statistical differences between the two groups (Group A vs. Group B) in patients' age (34 years vs. 33 years, p = 0.76), percentage of patients with hemorrhagic events before treatment (50% vs. 29%, p = 0.12), or percentage of AVM involving the basal ganglia and thalamus (36% vs. 46%, p = 0.46). Obliteration rates were 69% and 76% at 4 years in Groups A and B, respectively (p = 0.68), which were not significantly different. Motor complications were observed in 5 patients in Group A (17.9%) but only in 1 patient in Group B (4.2%), which was significantly less frequent (p = 0.021). Conclusion: Integrating DTT of the corticospinal tract into treatment planning contributed to reduction of motor complications without compromising the obliteration rate for AVM adjacent to the corticospinal tract.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Room Temperature Total-Ionizing Dose Testing of Glenn Research Center (GRC) 500 °C Durable 4H-SiC JFET IC Technology

The purpose of this testing was to obtain total ionizing dose (TID) information about custom-built research prototype silicon carbide (SiC) junction field effect transistor (JFET) integrated circuits (ICs) capable of prolonged operation in extremely high-temperature (500 degrees Centigrade) environments. The circuits included ring oscillators and operational amplifiers as well as individual n-channel JFETs. This technology is being considered for use in high temperature, high pressure applications such as Long-Lives Surface System Explorer (LLISSE). These devices were developed at NASA Glenn Research Center (GRC). Testing occurred from July 9th-July 13th, 2018.

Radiation↗

SU-E-E-15: Design of a Water Calorimeter for Dual Use in An Integrated MRI-Linac and Gamma-Knife

Purpose: To design a water calorimeter for dual use in an integrated MRI-linac and Gamma-Knife. In calorimetry, dose to water is measured based on the assumption that energy absorbed in a sensitive volume is completely converted to temperature rise {sub (}ΔΤ{sub )} according to the specific heat capacity of the medium c: D=c*ΔT*k, where k is heat transfer correction factor and compensates for heat gain or loss at point of measurement due to conductive effects. Methods: A commercial finite element method software package was used to model four different water calorimeter designs. The long term (48 h) thermal stability of each design was accurately modeled, and the optimization of the final design was based on evaluation of the standard deviation of k for ten consecutive irradiation runs (lower standard deviation translates to greater thermal stability). Several insulator materials of varying thicknesses were investigated, and a sensitivity study of thermal stability to variations in ambient temperature fluctuations was undertaken. Specifically, we evaluated the effect of possible variations in coolant temperature circulating around the calorimeter tank in several scenarios (constant, slowly increasing, or fluctuating). Results: Due to MRI-compatibility requirements, the calorimeter is to be built entirely out of plastic. Among all insulation materials tested, solid state aerogel-based insulation resulted in least heat loss and thermal stability. The final design is cylindrical on top (to be used upright in MRI-linac) and semi-spherical at bottom (for use in GammaKnife). The range of k was found to be 1.002 ± 0.013 (k = 1), comparable with a k of 1.002 ± 0.014 for typical water calorimeters used in high energy beams. A long term stability of 0.36 µK/hr was evaluated. Conclusion: Optimization of a water calorimeter design for dual use in MRI-linac and Gamma-Knife has been completed and the device is currently in production. Supported by NSERC RGPIN 435608.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-774: Use of a Scintillator-Mirror-Camera System for the Measurement of MLC Leakage Radiation with the CyberKnife M6 System

Purpose: A technique using a scintillator-mirror-camera system to measure MLC leakage was developed to provide an efficient alternative to film dosimetry while maintaining high spatial resolution. This work describes the technique together with measurement uncertainties. Methods: Leakage measurements were made for the InCise™ MLC using the Logos XRV-2020A device. For each measurement approximately 170 leakage and background images were acquired using optimized camera settings. Average background was subtracted from each leakage frame before filtering the integrated leakage image to replace anomalous pixels. Pixel value to dose conversion was performed using a calibration image. Mean leakage was calculated within an ROI corresponding to the primary beam, and maximum leakage was determined by binning the image into overlapping 1mm x 1mm ROIs. 48 measurements were performed using 3 cameras and multiple MLC-linac combinations in varying beam orientations, with each compared to film dosimetry. Optical and environmental influences were also investigated. Results: Measurement time with the XRV-2020A was 8 minutes vs. 50 minutes using radiochromic film, and results were available immediately. Camera radiation exposure degraded measurement accuracy. With a relatively undamaged camera, mean leakage agreed with film measurement to ≤0.02% in 92% cases, ≤0.03% in 100% (for maximum leakage the values were 88% and 96%) relative to reference open field dose. The estimated camera lifetime over which this agreement is maintained is at least 150 measurements, and can be monitored using reference field exposures. A dependency on camera temperature was identified and a reduction in sensitivity with distance from image center due to optical distortion was characterized. Conclusion: With periodic monitoring of the degree of camera radiation damage, the XRV-2020A system can be used to measure MLC leakage. This represents a significant time saving when compared to the traditional film-based approach without any substantial reduction in accuracy.

60 APPLIED LIFE SCIENCES↗

Space Radiation Risk Assessment for Future Lunar Missions

For lunar exploration mission design, radiation risk assessments require the understanding of future space radiation environments in support of resource management decisions, operational planning, and a go/no-go decision. The future GCR flux was estimated as a function of interplanetary deceleration potential, which was coupled with the estimated neutron monitor rate from the Climax monitor using a statistical model. A probability distribution function for solar particle event (SPE) occurrence was formed from proton fluence measurements of SPEs occurred during the past 5 solar cycles (19-23). Large proton SPEs identified from impulsive nitrate enhancements in polar ice for which the fluences are greater than 2 10(exp 9) protons/sq cm for energies greater than 30 MeV, were also combined to extend the probability calculation for high level of proton fluences. The probability with which any given proton fluence level of a SPE will be exceeded during a space mission of defined duration was then calculated. Analytic energy spectra of SPEs at different ranks of the integral fluences were constructed over broad energy ranges extending out to GeV, and representative exposure levels were analyzed at those fluences. For the development of an integrated strategy for radiation protection on lunar exploration missions, effective doses at various points inside a spacecraft were calculated with detailed geometry models representing proposed transfer vehicle and habitat concepts. Preliminary radiation risk assessments from SPE and GCR were compared for various configuration concepts of radiation shelter in exploratory-class spacecrafts.

Kim, Myung-Hee Y.↗

Radiation Transport Calculations in Support of FRIB Target Building Local Shield Design - Paper 113

Construction of the Facility for Rare Isotope Beams (FRIB) began in March 2014 on the campus of Michigan State University (MSU). FRIB will use a 400 kW heavy-ion driver LINAC to accelerate stable ions to energies greater than 200 MeV/u. Rare-isotope beam production will occur via interaction of the heavy-ion primary beam with a rotating carbon production target at the beginning of the fragmentation pre-separator located in the target building. An integral component of the design process involves the quantification of dose equivalents received by both facility personnel and the general public that can be expected once the facility is operational. The MSU ALARA goal for radiation to the general public from FRIB is <10 mrem/y (from all sources). (authors)

43 PARTICLE ACCELERATORS↗

DEMOLISHING A COLD-WAR-ERA FUEL STORAGE BASIN SUPERSTRUCTURE LADEN WITH ASBESTOS

The K East (KE) Basin facilities are located near the north end of the Hanford Site's 100 K area. The facilities were built in 1950 as part of the KE Reactor complex and constructed within 400 meters of the Columbia River, which is the largest river in the Pacific Northwest and by volume the fourth largest river in the United States. The basin, located adjacent to the reactor, was used for the underwater storage of irradiated nuclear fuel discharged from the reactor. The basin was covered by a superstructure comprising steel columns and beams, concrete, and cement asbestos board (CAB) siding. The project's mission was to complete demolition of the structure over the K East basin within six months of tumover from facility deactivation activities. The demolition project team implemented open-air demolition techniques to demolish the facility to slab-on-grade. Several innovative techniques were used to control contamination and maintain contamination control within the confines of the demolition exclusion zone. The techniques, which focused on a defense-in-depth approach, included spraying fixatives on interior and exterior surfaces before demolition began; applying fixatives; misting using a fine spray of water during demolition; and demolishing the facility systematically. Another innovation that aided demolition was to demolish the building with the non-friable CAB remaining in place. The CAB siding covered the exterior of the building, portions of the interior walls, and was an integral part of the multiple layered roof. The project evaluated the risks involved in removing the CAB material in a radiologically contaminated environment and determined that radiological dose rates and exposure to radiological contamination and industrial hazards would be significantly reduced by removing the CAB during demolition using heavy equipment. The ability to perform this demolition safely and without spreading contamination (radiological or asbestos) demonstrates that similar open-air demolition ofcontaminated structures can be performed successfully.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Graves' disease radioiodine-therapy: Choosing target absorbed doses for therapy planning

Purpose: The precise determination of organ mass (m{sub th}) and total number of disintegrations within the thyroid gland (A{sup ~}) are essential for thyroid absorbed-dose calculations for radioiodine therapy. Nevertheless, these parameters may vary according to the method employed for their estimation, thus introducing uncertainty in the estimated thyroid absorbed dose and in any dose–response relationship derived using such estimates. In consideration of these points, thyroid absorbed doses for Graves’ disease (GD) treatment planning were calculated using different approaches to estimating the m{sub th} and the A{sup ~}. Methods: Fifty patients were included in the study. Thyroid{sup 131}I uptake measurements were performed at 2, 6, 24, 48, 96, and 220 h postadministration of a tracer activity in order to estimate the effective half-time (T{sub eff}) of {sup 131}I in the thyroid; the thyroid cumulated activity was then estimated using the T{sub eff} thus determined or, alternatively, calculated by numeric integration of the measured time-activity data. Thyroid mass was estimated by ultrasonography (USG) and scintigraphy (SCTG). Absorbed doses were calculated with the OLINDA/EXM software. The relationships between thyroid absorbed dose and therapy response were evaluated at 3 months and 1 year after therapy. Results: The average ratio (±1 standard deviation) betweenm{sub th} estimated by SCTG and USG was 1.74 (±0.64) and that between A{sup ~} obtained by T{sub eff} and the integration of measured activity in the gland was 1.71 (±0.14). These differences affect the calculated absorbed dose. Overall, therapeutic success, corresponding to induction of durable hypothyroidism or euthyroidism, was achieved in 72% of all patients at 3 months and in 90% at 1 year. A therapeutic success rate of at least 95% was found in the group of patients receiving doses of 200 Gy (p = 0.0483) and 330 Gy (p = 0.0131) when m{sub th} was measured by either USG or SCTG and A{sup ~} was determined by the integration of measured {sup 131}I activity in the thyroid gland and based on T{sub eff}, respectively. No statistically significant relationship was found between therapeutic response and patients’ age, administered {sup 131}I activity (MBq), 24-h thyroid {sup 131}I uptake (%) or T{sub eff} (p ≥ 0.064); nonetheless, a good relationship was found between the therapeutic response and m{sub th} (p ≤ 0.035). Conclusions: According to the results of this study, the most effective thyroid absorbed dose to be targeted in GD therapy should not be based on a fixed dose but rather should be individualized based on the patient'sm{sub th} and A{sup ~}. To achieve a therapeutic success (i.e., durable euthyroidism or hypothyroidism) rate of at least 95%, a thyroid absorbed dose of 200 or 330 Gy is required depending on the methodology used for estimating m{sub th} and A{sup ~}.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation-induced bowing of SiC/SiC composites under neutron flux gradients—integral experimental data for model validation

Here, the radiation-induced swelling of SiC and its composites, including strong dependencies on temperature and dose, can drive significant lateral bowing in the presence of temperature and/or dose gradients. In recent years, simulations have been performed to assess the extent of bowing in SiC composite light-water reactor (LWR) fuel cladding and boiling water reactor (BWR) channel boxes. However, to date, no integral experimental data exist to validate these models. This work provides the first experimental bowing evaluation of three ∼380 mm long SiC composite specimens irradiated under varying neutron dose gradients (∼50°C–60°C, 0.03–0.06 dpa): two tubes (∼9.8 mm diameter) and a miniature BWR channel box (∼30 mm square). The measured radiation-induced length swelling (∼0.3%–0.7% linear) was consistently 10%–21% higher than values obtained from 3D finite element structural analyses with inputs from 3D radiation transport calculations. This discrepancy could be at least partially explained by differences in dose rate (∼10 -8 dpa/s) compared to the literature data (∼10-6 dpa/s) used to establish the dose-to-swelling correlations in the model. Nevertheless, the modeled bowing magnitudes (<2 mm) obtained from finite element analyses and simple analytical equations were within the bounds of the experimental measurements for all specimens. With improved confidence in the ability to predict the structural response and measure the macroscopic deformations, future experiments will target transient bowing under neutron flux gradients at representative LWR temperatures and assess whether grid spacers can mitigate the tens of millimeters of bowing that would otherwise be expected in ∼4 m long LWR components.

bowing↗

Comparison of Likelihood Methods for Generalized Linear Mixed Models with Application to Quiet Supersonic Flights 2018 Data

Repeated measurement will be a feature of the survey data collected during the Quesst missionX-59 community response tests (CRT). Since each participant will report his or her categorical level of annoyance in response to multiple events, the responses from any single individual may be correlated with one another. Several models within the class of generalized linear mixed models (GLMM) are pertinent to the analysis of correlated categorical outcomes; the random intercept logistic regression model is one example. Both Bayesian and frequentist methods for fitting these models are available, with frequentist methods relying on some form of approximation (of either an integral or the integrand) that appears in the marginal likelihood function. Given several anticipated similarities of the X-59 CRT data to data collected during a past risk reduction, Quiet Supersonic Flights 2018 (QSF18), this short note is intended to create awareness. It documents an instance in which a reported population average dose-response relationship derived from QSF18 single event data was distorted by the integral approximation applied in likelihood-based methods. We review some of the available literature on the topic, compare the outputs of several different computational approaches implemented in available statistical software, and present simple corrective actions that may be useful during the Quesst mission.

dose-response model↗

Toward optimal organ at risk sparing in complex volumetric modulated arc therapy: An exponential trade-off with target volume dose homogeneity

Purpose: Conventional radiotherapy typically aims for homogenous dose in the planning target volume (PTV) while sparing organs at risk (OAR). The authors quantified and characterized the trade-off between PTV dose inhomogeneity (IH) and OAR sparing in complex head and neck volumetric modulated arc therapy plans. Methods: Thirteen simultaneous integrated boost plans were created per patient, for ten patients. PTV boost{sub (B)}/elective{sub (E)} optimization priorities were systematically increased. IH{sub B} and IH{sub E}, defined as (100% − V95%) + V107%, were evaluated against the average of the mean dose to the combined composite swallowing and combined salivary organs (D-OAR{sub comp}). To investigate the influence of OAR size and position with respect to PTV{sub B/E}, OAR dose was evaluated against a modified Euclidean distance (DM{sub B}/DM{sub E}) between OAR and PTV. Results: Although the achievable D-OAR{sub comp} for a given level of PTV IH differed between patients, excellent logarithmic fits described the D-OAR{sub comp}/IH{sub B} and IH{sub E} relationship in all patients (mean R{sup 2} of 0.98 and 0.97, respectively). Allowing an increase in average IH{sub B} and IH{sub E} over a clinically acceptable range, e.g., from 0.4% ± 0.5% to 2.0% ± 2.0% and 6.9% ± 2.8% to 14.8% ± 2.7%, respectively, corresponded to a decrease in average dose to the composite salivary and swallowing structures from 30.3 ± 6.5 to 23.6 ± 4.7 Gy and 32.5 ± 8.3 to 26.8 ± 9.3 Gy. The increase in PTV{sub E} IH was mainly accounted for by an increase in V107, by on average 5.9%, rather than a reduction in V95, which was on average only 2%. A linear correlation was found between the OAR dose to composite swallowing structures and contralateral parotid and submandibular gland, with DM{sub E} (R{sup 2} = 0.83, 0.88, 0.95). Only mean ipsilateral parotid dose correlated with DM{sub B} (R{sup 2} = 0.87). Conclusions: OAR sparing is highly dependent on the permitted PTV{sub B/E} IH. PTV{sub E} IH substantially influences OAR doses. These results are relevant for clinical practice and for future automated treatment-planning strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Whole-Brain Radiotherapy With Simultaneous Integrated Boost to Multiple Brain Metastases Using Volumetric Modulated Arc Therapy

Purpose: Volumetric modulated arc therapy (RapidArc [RA]; Varian Medical Systems, Palo Alto, CA) allows for the generation of intensity-modulated dose distributions by use of a single gantry rotation. We used RA to plan and deliver whole-brain radiotherapy (WBRT) with a simultaneous integrated boost in patients with multiple brain metastases. Methods and Materials: Composite RA plans were generated for 8 patients, consisting of WBRT (20 Gy in 5 fractions) with an integrated boost, also 20 Gy in 5 fractions, to Brain metastases, and clinically delivered in 3 patients. Summated gross tumor volumes were 1.0 to 37.5 cm{sup 3}. RA plans were measured in a solid water phantom by use of Gafchromic films (International Specialty Products, Wayne, NJ). Results: Composite RA plans could be generated within 1 hour. Two arcs were needed to deliver the mean of 1,600 monitor units with a mean 'beam-on' time of 180 seconds. RA plans showed excellent coverage of planning target volume for WBRT and planning target volume for the boost, with mean volumes receiving at least 95% of the prescribed dose of 100% and 99.8%, respectively. The mean conformity index was 1.36. Composite plans showed much steeper dose gradients outside Brain metastases than plans with a conventional summation of WBRT and radiosurgery. Comparison of calculated and measured doses showed a mean gamma for double-arc plans of 0.30, and the area with a gamma larger than 1 was 2%. In-room times for clinical RA sessions were approximately 20 minutes for each patient. Conclusions: RA treatment planning and delivery of integrated plans of WBRT and boosts to multiple brain metastases is a rapid and accurate technique that has a higher conformity index than conventional summation of WBRT and radiosurgery boost.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Weighted Radiographic Source-Spot Size

The spatial resolution of a flash radiograph is determined by the time-integrated size of the radiation source. Since the radiation pulse includes the beam head and tail, which may be substantially larger than the beam body, the radiation source is larger than the focused flattop of the electron beam pulse. Moreover, the radiation dose rate is weighted by both beam current and electron energy, and it is the radiation dose that forms the radiograph image. Therefore, in order to estimate radiographic resolution from computer simulations of a focused electron beam, one should use a dose weighted moment analysis of the radiation source distribution. This approach is used to show that, in the absence of beam effects other than space-charge and emittance, radiographic resolution for Scorpius exceeds requirements, regardless of reasonable timing options for current and gap-voltage pulses.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantitative Ultrasound Characterization of Cancer Radiotherapy Effects In Vitro

Purpose: Currently, no routinely used imaging modality is available to assess tumor responses to cancer treatment within hours to days after radiotherapy. In this study, we demonstrate the preclinical application of quantitative ultrasound methods to characterize the cellular responses to cancer radiotherapy in vitro. Methods and Materials: Three different cell lines were exposed to radiation doses of 2-8 Gy. Data were collected with an ultrasound scanner using frequencies of 10-30 MHz. As indicators of response, ultrasound integrated backscatter and spectral slope were determined from the cell samples. These parameters were corrected for ultrasonic attenuation by measuring the attenuation coefficient. Results: A significant increase in the ultrasound integrated backscatter of 4-7 dB (p < 0.001) was found for radiation-treated cells compared with viable cells at all radiation doses. The spectral slopes decreased in the cell samples that predominantly underwent mitotic arrest/catastrophe after radiotherapy, consistent with an increase in cell size. In contrast, the spectral slopes did not change significantly in the cell samples that underwent a mix of cell death (apoptosis and mitotic arrest), with no significant change in average cell size. Conclusion: The changes in ultrasound integrated backscatter and spectral slope were direct consequences of cell and nuclear morphologic changes associated with cell death. The results indicate that this combination of quantitative ultrasonic parameters has the potential to assess the cell responses to radiation, differentiate between different types of cell death, and provide a preclinical framework to monitor tumor responses in vivo.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-12A-01: Primary Vs. Scatter Contribution to Body CTDI: Experiment Results

Purpose: To quantify experimentally scatter contribution to CTDI in center and peripheral holes of the body (32-cm) phantom. Methods: All experiments were performed in Service Mode of 750CT-Discovery with both tube and table were in stationary position, and with large filter and 40- mm collimation. First, transmission through acrylic was measured using acrylic rods of various lengths (1-cm to 33-cm), at 80, 120, and 140 kVp. These data were utilized to obtain dose from primary beam at different depths of acrylic. Thus, scatter-to-primary ratio (SPR) was determined for center-hole by measuring exposure with a pencil chamber. For peripheral hole SPR, dose was measured at eight different tube angles from 0° to 180°. Change in primary dose with tube angle due to both shape of bowtie filter and distance from tube was measured in air; hence, dose from primary from each of the 8 phantom measurements was determined and SPR was calculated by integrating the fitted models for primary and scatter distributions as a function of distance from tube. Also, scatter contribution from different segments of phantom to center-hole dose was measured using a custom-built acrylic phantom, which had similar SPR at the center-hole to that of standard body phantom. Results: After correcting for stray radiation (off-focus, scatter from collimators, etc.) for primary measurements, preliminary results of SPRs in center-hole dose of the body phantom for 80, 120, and 140 kVp were 6.8, 6.2, and 6.0, respectively, and for peripheral hole were 1.45, 1.44, and 1.39. Forward-scatter and backscatter contributions to center dose, at any point during tube rotation, were respectively, 62% and 38% with 80 kVp, and 60% and 40% with 120 and 140 kVp. Conclusion: SPR in both center and peripheral holes of body CTDI phantom was determined experimentally. Also, distribution of contributing scatter to center hole was estimated.

60 APPLIED LIFE SCIENCES↗