At least 559 records · Page 31

Impacts of future nuclear power generation on the international monitoring system

Many countries are considering nuclear power as a means of reducing greenhouse gas emissions, and the IAEA (IAEA, 2022) has forecasted nuclear power growth rates up to 224% of the 2021 level by 2050. Nuclear power plants release trace quantities of radioxenon, an inert gas that is also monitored under international agreements as a signature of nuclear weapons tests. To better understand how nuclear energy growth (and resulting Xe emissions) could affect this global nonproliferation architecture, we modeled daily releases of radioxenon isotopes used for nuclear explosion detection in the International Monitoring System (IMS) that is part of the Comprehensive Nuclear Test-Ban Treaty: 131m Xe, 133 Xe, 133m Xe, and 135 Xe to examine the change in the number of radioxenon detections as compared to the 2021 detection levels. If a 40-station IMS network is used, the detections of 133 Xe in 2050 would range from 82% for the low-power scenario to 195% for the high-power scenario, compared to the detections in 2021. If an 80-station IMS network is used, the detections of 133 Xe in 2050 would range from 83% of the 2021 detection rate for the low-power scenario to 209% for the high-power scenario. Essentially no detections of 131m Xe and 133m Xe are expected. The high growth scenario could lead to a six-fold increase in 135 Xe detections, but the total number of detections is still small (on the order of 1 detection per day in the entire network).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Synthesis and characterization of mangenese(III) porphyrin supported on imidazole modified chloromethylated MIL-101(Cr): A heterogeneous and reusable catalyst for oxidation of hydrocarbons with sodium periodate

In the present work, chloromethylated MIL-101(Cr) modified with imidazole, Im-MIL-101, was applied as a support for immobilizing of tetraphenylporphyrinatomangenese(III) chloride. The imidazole-bound MIL-101, Im-MIL-101, not only used as support for immobilization of manganese porphyrin but also applied as a heterogeneous axial base. The Mn(TPP)Cl@Im-MIL-101 catalyst was characterized by UV–vis, FT-IR, X-ray diffraction (XRD), N{sub 2} adsorption, field emission scanning electron microscopy (FE-SEM), energy dispersive X-ray (EDX), elemental analysis and inductively coupled plasma (ICP) methods. The catalytic activity of this new catalytic system was investigated in the alkene epoxidation and alkane hydroxylation using NaIO{sub 4} as an oxidant in CH{sub 3}CN/H{sub 2}O at room temperature. This heterogeneous catalyst is highly efficient, stable and reusable in the oxidation of hydrocarbons. - Highlights: • MIL-101 was modified by covalent post synthetic modification. • Mn(TPP)Cl was anchored to imidazole modified MIL-101 by covalent attachment. • A heterogeneous catalyst was prepared. • The catalyst was used for epoxidation of alkenes and hydroxylation of alkanes. • The catalyst was reusable.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Carbonic anhydrase inhibition boosts the antitumor effects of Imatinib mesylate via potentiating the antiangiogenic and antimetastatic machineries

Carbonic anhydrase inhibitors have emerged in the past few years as an interesting candidate for the development of novel unconventional strategies. Despite their effect in tumor regression via inhibition of tumor acidification, their potential role is not yet fully elucidated. Herein, we investigated whether acetazolamide (AZ) could modulate imatinib (IM) anticancer activity, both in breast cancer cells (T47D) and in isolated tumor specimens of Ehrlich ascites carcinoma (EAC). The impact of this combination on angiogenesis was evidenced by decreasing PDGF-A expression and enhancing that of TSP-1. In the meantime, AZ significantly suppressed IM-induced attenuation of VEGF secretion in T47D cells, most probably due to NO inhibition. The combination also dramatically decreased the metastatic activity of T47D cells by mitigating the protein levels of MMP-2 and -9 and phosphorylation of p38 MAPK, while increasing the expression of TIMP-1 and -2. In addition, a strong proapoptotic effect was observed in T47D cells after combining AZ and IM in terms of increased caspase-9 and -3 activities. Interestingly, these results were confirmed by the reduction in the isolated tumor volume, MVD, Ki-67 and VEGF expression. Eventually, the study provides a new therapeutic strategy for treating cancer. - Highlights: • A novel combination of imatinib and a carbonic anhydrase was studied. • The impact was evaluated in T47D cells and EAC-bearing mice. • The interaction suppressed PDGF-A and VEGF while enhanced TSP-1. • MMPs and p38 MAPK phosphorylation were suppressed while TIMPs were enhanced. • The interaction triggered caspase-9 and -3 activation.

60 APPLIED LIFE SCIENCES↗

Use of an ion mobility spectrometer for detecting uranium compounds

The safeguards community currently lacks a method to rapidly determine the chemical form of radioactive and non-radioactive compounds in real time during inspection activities. Chemical speciation identification can provide important information on both the types of materials that are collected during environmental sampling and can inform inspectors as to where to focus efforts during inspections or complementary access visits. Ion Mobility Spectrometry (IMS) is an established field technique for the detection of explosives, narcotics, and other organic compounds. More recently, electrospray ionization (ESI) has been used to introduce inorganic compounds to IMS instruments for analysis. These techniques have shown the ability to supply chemical information about the compounds being analyzed. Although these laboratory based instruments use a liquid-based injection system, there is evidence in the literature of unaltered and intact pharmaceutical tablets being volatilized and ionized in open atmosphere using heat and a Ni-63 source. Lastly, this work determined that a commercial-off-the-shelf (COTS) IMS could be used for the identification of solid uranium compounds directly after sampling using a COTS sample swipe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Opening new paths for biological applications of ion mobility - Mass spectrometry using structures for lossless ion manipulations

Ion mobility separations coupled to mass spectrometry (IM-MS) have received much attention for their ability to provide complementary structural information to solution-phase-based separations, as well as to aid in the identification of unknown compounds. While IM-MS is an increasingly powerful analytical technique, significant bottlenecks related to the resolution and sensitivity of measurements have kept it from becoming broadly applied for biological analyses. Structures for Lossless Ion Manipulations (SLIM)-based IM separations have successfully overcome these aforementioned bottlenecks, addressing issues associated with resolution and sensitivity in the omics, and potentially opening the door to broader application.

Garimella, Venkata BS↗

Application of multiplexed ion mobility spectrometry towards the identification of host protein signatures of treatment effect in pulmonary tuberculosis

Rationale: The monitoring of TB treatments in clinical practice and clinical trials relies on traditional sputum-based culture status indicators at specific time points. Accurate, predictive, blood-based protein markers would provide a simpler and more informative view of patient health and response to treatment. Objective: We utilized sensitive, high throughput multiplexed ion mobility-mass spectrometry (IM-MS) to characterize the serum proteome of TB patients at the start of and at 8 weeks of rifamycin-based treatment. We sought to identify treatment specific signatures within patients as well as correlate the proteome signatures to various clinical markers of treatment efficacy. Methods: Serum samples were collected from 289 subjects enrolled in CDC TB Trials Consortium Study 29 at time of enrollment and at the end of the intensive phase (after 40 doses of TB treatment). Serum proteins were immunoafinity-depleted of high abundant components, digested to peptides and analyzed for data acquisition utilizing a unique liquid chromatography IM-MS platform (LC-IM-MS). Linear mixed models were utilized to identify serum protein changes in the host response to antibiotic treatment as well as correlations with culture status end points. Results: A total of 10,137 peptides corresponding to 872 proteins were identified, quantified, and used for statistical analysis across the longitudinal patient cohort. In response to TB treatment, 244 proteins were sig- ni?cantly altered. Pathway/network comparisons helped visualize the interconnected proteins, identifying up regulated (lipid transport, coagulation cascade, endopeptidase activity) and down regulated (acute phase) processes and pathways in addition to other cross regulated networks (inflammation, cell adhesion, extracellular matrix). Detection of possible lung injury serum proteins such as HPSE, significantly downregulated upon treatment. Analyses of microbiologic data over time identified a core set of serum proteins (TTHY, AFAM, CRP, RET4, SAA1, PGRP2) which change in response to treatment and also strongly correlate with culture status. A similar set of proteins at baseline were found to be predictive of week 6 and 8 culture status. Conclusion: A comprehensive host serum protein dataset reflective of TB treatment effect is defined. A repeating set of serum proteins (TTHY, AFAM, CRP, RET4, SAA1, PGRP2, among others) were found to change significantly in response to treatment, to strongly correlate with culture status, and at baseline to be predictive of future culture conversion. If validated in cohorts with long term follow-up to capture failure and relapse of TB, these protein markers could be developed for monitoring of treatment in clinical trials and in patient care.

Kedia, Komal↗

The new challenges of end-of-life tyres management systems: A Spanish case study

Highlights: ► Impact of the implementation of the Directive 2008/98/EC in Spain for end-of-life tyres. ► Characterization of the reverse supply chain for collecting, recovering, and treating end-of-life tyres. ► Identification of challenges to be coped and issues to be covered. ► Potential new applications for end-of-life tyres and development of new management related strategies. - Abstract: Directive 2008/98/EC released by the European Union represents a significant step forward in all relevant aspects of waste management. Under the already established, extended produced responsibility (EPR) principle, new policies have been enunciated to continuously achieve better overall environmental performance of key products throughout their life phases. This paper discusses how the directive is being articulated in Spain by the main integrated management system (IMS) for end-of-life (EOL) tyres since its creation in 2006. Focusing on the IMS technological, economic and legal aspects, the study provides a global perspective and evaluation of how the IMS is facing the current issues to resolve, the new challenges that have appeared and the management vision for the coming years.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion Mobility Separation of Isomeric Phosphopeptides from a Protein with Variant Modification of Adjacent Residues

Ion mobility spectrometry (IMS), and particularly differential IMS or field asymmetric waveform IMS (FAIMS), was recently shown capable of separating post-translationally modified peptides with variant PTM localization. However, that work was limited to a model peptide with serine phosphorylation on fairly distant alternative sites. Here, we demonstrate that FAIMS (coupled to ESI/MS) can broadly baseline-resolve variant phosphopeptides from a biologically modified human protein, including those involving phosphorylation of different residues and adjacent sites that existing MS/MS methods are most challenged to distinguish. Singly and doubly phosphorylated variants can be resolved equally well and identified without dissociation, based on accurate separation properties. The results are unchanged over a range of infusion solvent pH, hence present approach should work in conjunction with chromatographic separations using a mobile phase gradient.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental Evaluation and Optimization of Structures for Lossless Ion Manipulations for Ion Mobility Spectrometry with Time-of-Flight Mass Spectrometry

We report on the performance of Structures for Lossless Ion Manipulation (SLIM) devices as a means for transmitting ions and performing ion mobility separations (IMS). Ions were successfully transferred from an electrospray ionization (ESI) source to the TOF MS analyzer by means of a linear SLIM device and an alternative arrangement including a 90° turn. First, the linear geometry was optimized for radial confinement by tuning RF on the central ‘rung’ electrodes and potentials on the DC-only guard electrodes. Selecting an appropriate DC guard bias (2-6 V) and RF amplitude (≥160 Vp-p at 750 kHz) resulted in the greatest ion intensities. Close to ideal IMS resolving power was maintained over a range of applied voltages. Second, the 90° turn was optimized for radial confinement by tuning the RF on the rung electrodes and DC on the guard electrodes; however, both resolving power and ion transmission showed a dependence on these voltages and the best conditions for both were > 300 Vp-p RF (685 kHz) and 7-11 V guard DC bias. Both geometries provide IMS resolving powers at the theoretical limit (R~58), showing that the negative “racetrack” effect from turning around a corner can be successfully avoided, as well as the capability for essentially lossless ion transmission.

conveyor↗

Development of a Platform for High-Resolution Ion Mobility Separations Coupled with Messenger Tagging Infrared Spectroscopy for High-Precision Structural Characterizations

The ability to uniquely identify a compound requires highly precise and orthogonal measurements. Here we describe a newly developed analytical platform that integrates high resolution ion mobility and cryogenic vibrational ion spectroscopy for high-precision structural characterizations. This platform allows for the temporal separation of isomeric/isobaric ions and provides a highly sensitive description of the ion’s adopted geometry in the gas phase. The combination of these orthogonal structural measurements yields precise descriptors that can be used to resolve between and confidently identify highly similar ions. The unique benefits of our instrument, which integrates a structures for lossless ion manipulations ion mobility (SLIM IM) device with messenger tagging infrared spectroscopy, include the ability to perform high-resolution ion mobility separations and to record the IR spectra of all ions simultaneously. The SLIM IM device, with its 13 m separation path length, allows for multipass experiments to be performed for increased resolution as needed. It is integrated with an Agilent qTOF MS where the collision cell was replaced with a cryogenically held (30 K) TW-SLIM module. The cryo-SLIM is operated in a novel manner that allows ions to be streamed through the device and collisionally cooled to a temperature where they can form noncovalently bound N 2 complexes that are maintained as they exit the device and are detected by the TOF mass analyzer. The instrument can be operated in two modes: IMS+IR where the IR spectra for mobility-selected ions can be recorded and IR-only mode where the IR spectra for all mass-resolved ions can be recorded. In IR-only mode, IR spectra (400 cm –1 spectral range) can be recorded in as short as 2 s for high throughput measurements. Further, this work details the construction of the instrument and modes of operation. It provides initial benchmarking of CCS and IR measurements to demonstrate the utility of this instrument for targeted and untargeted approaches.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Squeezing of Ion Populations and Peaks in Traveling Wave Ion Mobility Separations and Structures for Lossless Ion Manipulations using Compression Ratio Ion Mobility Programming

In this work, we report an approach for spatial and temporal gas phase ion population manipulation, and demonstrate its application for the collapse of the ion distributions in ion mobility (IM) separations into tighter packets providing higher sensitivity measurements in conjunction with mass spectrometry (MS). We do this for ions moving from a conventionally traveling wave (TW)-driven region to a region where the TW is intermittently halted or ‘stuttered’. This approach causes the ion packets spanning a number of TW-created traveling traps (TT) to be redistributed into fewer TT, resulting in spatial compression. The degree of spatial compression is controllable and determined by the ratio of stationary time of the TW in the second region to its moving time. This compression ratio ion mobility programming (CRIMP) approach has been implemented using Structures for Lossless Ion Manipulations (SLIM) in conjunction with MS. CRIMP with the SLIM-MS platform is shown to provide increased peak intensities, reduced peak widths, and improved S/N ratios with MS detection. CRIMP also provides a foundation for extremely long path length and multi-pass IM separations in SLIM providing greatly enhanced IM resolution by reducing the detrimental effects of diffusional peak broadening due to increasing peak widths.

Environmental Molecular Sciences Laboratory↗

Ion Elevators and Escalators in Multilevel Structures for Lossless Ion Manipulations

We describe two approaches based upon ion ‘elevator’ and ‘escalator’ components that allow moving ions to different levels in structures for lossless ion manipulations (SLIM). Guided by ion motion simulations we designed elevator and escalator components providing essentially lossless transmission in multi-level designs based upon ion current measurements. The ion elevator design allowed ions to efficiently bridge a 4 mm gap between levels. The component was integrated in a SLIM and coupled to a QTOF mass spectrometer using an ion funnel interface to evaluate the m/z range transmitted as compared to transmission within a level (e.g. in a linear section). Mass spectra for singly-charged ions of m/z 600-2700 produced similar mass spectra for both elevator and straight (linear motion) components. In the ion escalator design, traveling waves (TW) were utilized to transport ions efficiently between two SLIM levels. Ion current measurements and ion mobility (IM) spectrometry analysis illustrated that ions can be transported between TW-SLIM levels with no significant loss of either ions or IM resolution. These developments provide a path for the development of multilevel designs providing e.g. much longer IM path lengths, more compact designs, and the implementation of much more complex SLIM devices in which e.g. different levels may operate at different temperatures or with different gases.

Environmental Molecular Sciences Laboratory↗

Compression Ratio Ion Mobility Programming (CRIMP) Accumulation and Compression of Billions of Ions for Ion Mobility-Mass Spectrometry Using Traveling Waves in Structures for Lossless Ion Manipulations (SLIM)

We report on the implementation of a traveling wave (TW) based compression ratio ion mobility programming (CRIMP) approach within Structures for Lossless Ion Manipulations (SLIM) that enables both greatly enlarged trapped ion charge capacities and also their subsequent efficient compression for use in ion mobility (IM) separations. Ion accumulation is conducted in a long serpentine path TW SLIM region after which CRIMP allows the large ion populations to be ‘squeezed’. The compression process occurs at an interface between two SLIM regions, one operating conventionally and the second having an intermittently pausing or ‘stuttering’ TW, allowing the contents of multiple bins of ions from the first region to be merged into a single bin in the second region. In this initial work stationary voltages in the second region were used to block ions from exiting the first (trapping) region, and the resumption of TWs in the second region allows ions to exit, and the population to also be compressed if CRIMP is applied. In our initial evaluation we show that the number of charges trapped for a 40 s accumulation period was ~5×109, more than two orders of magnitude greater than the previously reported charge capacity using an ion funnel trap. We also show that over 1×109 ions can be accumulated with high efficiency in the present device, and that the extent of subsequent compression is only limited by the space charge capacity of the trapping region. Lower compression ratios allow increased IM peak heights without significant loss of signal, while excessively large compression ratios can lead to ion losses and other artifacts. Importantly, we show that extended ion accumulation in conjunction with CRIMP and multiple passes provides the basis for a highly desirable combination of ultra-high sensitivity and ultra-high resolution IM separations using SLIM.

Environmental Molecular Sciences Laboratory↗

Traveling-Wave-Based Electrodynamic Switch for Concurrent Dual-Polarity Ion Manipulations in Structures for Lossless Ion Manipulations

In this work, we describe the development of a dual-polarity traveling-wave (TW) structures for lossless ion manipulations (SLIM) ion mobility spectrometry (IMS) device capable of switching both positive and negative ions that are traveling simultaneously along the same path to different regions of the SLIM. Through simulations, the routing efficiency of the SLIM TW switch was compared to a SLIM direct-current-based (DC) switch developed previously for IMS-MS. We also report on the initial experimental evaluation of a dual-polarity SLIM platform, which uses the TW-based ion switch to achieve higher resolution multipass serpentine ultralong path with extended routing (SUPER) IMS separations. Overall, these results show that the dual-polarity TW switch is not only as effective as DC switching in terms of routing efficiency but also is agnostic to the polarity of the ions being routed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of the Frequency and Diversity of 1,3-Dialkylimidazolium Ionic Liquids Appearing in the Literature

The hypothetical assertion that there are potentially millions of ionic liquids (ILs) can be validated using basic knowledge of IL precursors and simple calculations. While it is an interesting thought exercise to ponder the possibilities of ILs, it is important to investigate how many discrete ILs (i.e., unique cation and anion pairings) have actually been synthesized and reported in the literature. A complete analysis of all ILs is a daunting task, especially if the definition of what constitutes an IL is broad. Nonetheless, insight can be gained into the use of ILs over the past ~20 years from a focused analysis of systematically varied 1,3-dialkylimidazolium-based ILs (i.e., [R 1 R 2 im][X], where R 1 and R 2 are n-alkyl chains and X is either a halide or molecular anion). This family of ILs includes many of the most widely used and most thoroughly studied IL substances, including 1-butyl-3-methylimidazolium hexafluorophosphate ([C 4 mim][PF 6 ]) and 1-ethyl-3-methylimidazolium bistriflimide ([C 2 mim][Tf 2 N]). Using data retrieved from SciFinder searches, we analyzed the variety and frequency of 1,3-dialkylimidazolium-based ILs appearing in the literature. Our analysis reveals that there is a relatively large number of simple 1,3-dialkylimidazolium cations which have not yet been synthesized. Our findings indicate that despite the broad possibilities of IL structures available, there are but a handful of ILs that are commonly used and studied. Within the 1248 [R 1 R 2 im][X] ILs studied, there were only 12 cations extensively used, which included [R 1 R 2 im] + (R 1 = C 1 and R 2 = C 1 –C 12 ). Of the 16 anions studied, only 5, including [BF 4 ] – , [Cl] – , [PF 6 ] – , [Tf 2 N] – , and [Br] – , were used significantly. Thus, it appears that although ILs can be used as designer solvents with task-specific properties, there is a small default subset of ILs, which are “go-to” or “one-size-fits-all.” Here, we rationalize the current state of the IL landscape in terms of the historical perceptions (and misconceptions) around ILs, familiarity, availability and cost of starting materials, commercial availability of ILs, and the motivations from which researchers choose to synthesize and characterize new ILs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CO Displacement in an Oxidative Addition of Primary Silanes to Rhodium(I)

The rhodium dicarbonyl {PhB(Ox Me2 ) 2 Im Mes }Rh(CO) 2 (1) and primary silanes react by oxidative addition of a nonpolar Si–H bond and, uniquely, a thermal dissociation of CO. These reactions are reversible, and kinetic measurements model the approach to equilibrium. Thus, 1 and RSiH 3 react by oxidative addition at room temperature in the dark, even in CO-saturated solutions. The oxidative addition reaction is first-order in both 1 and RSiH 3 , with rate constants for oxidative addition of PhSiH 3 and PhSiD 3 revealing k H / k D ~ 1. The reverse reaction, reductive elimination of Si–H from {PhB(Ox Me 2 ) 2 Im Mes }RhH(SiH 2 R)CO (2), is also first-order in [2] and depends on [CO]. The equilibrium concentrations, determined over a 30 °C temperature range, provide Δ H ° = –5.5 ± 0.2 kcal/mol and Δ S ° = –16 ± 1 cal·mol –1 K –1 (for 1 ⇌ 2). The rate laws and activation parameters for oxidative addition (Δ H ‡ = 11 ± 1 kcal·mol –1 and Δ S ‡ = –26 ± 3 cal·mol –1 ·K –1 ) and reductive elimination (Δ H ‡ = 17 ± 1 kcal·mol –1 and Δ S ‡ = –10 ± 3 cal·mol –1 K –1 ), particularly the negative activation entropy for both forward and reverse reactions, suggest the transition state of the rate-determining step contains {PhB(Ox Me 2 ) 2 Im Mes }Rh(CO) 2 and RSiH 3 . Comparison of a series of primary silanes reveals that oxidative addition of arylsilanes is ca. 5× faster than alkylsilanes, whereas reductive elimination of Rh–Si/Rh–H from alkylsilyl and arylsilyl rhodium(III) occurs with similar rate constants. Furthermore, the equilibrium constant K e for oxidative addition of arylsilanes is >1, whereas reductive elimination is favored for alkylsilanes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Parallel Guanine Duplex and Cytosine Duplex DNA with Uninterrupted Spines of Ag I -Mediated Base Pairs

Here, hydrogen bonding between nucleobases produces diverse DNA structural motifs, including canonical duplexes, guanine (G) quadruplexes, and cytosine (C) i-motifs. Incorporating metal-mediated base pairs into nucleic acid structures can introduce new functionalities and enhanced stabilities. Here we demonstrate, using mass spectrometry (MS), ion mobility spectrometry (IMS), and fluorescence resonance energy transfer (FRET), that parallel-stranded structures consisting of up to 20 G–Ag I –G contiguous base pairs are formed when natural DNA sequences are mixed with silver cations in aqueous solution. FRET indicates that duplexes formed by poly(cytosine) strands with 20 contiguous C–Ag I –C base pairs are also parallel. Silver-mediated G-duplexes form preferentially over G-quadruplexes, and the ability of Ag + to convert G-quadruplexes into silver-paired duplexes may provide a new route to manipulating these biologically relevant structures. IMS indicates that G-duplexes are linear and more rigid than B-DNA. DFT calculations were used to propose structures compatible with the IMS experiments. Such inexpensive, defect-free, and soluble DNA-based nanowires open new directions in the design of novel metal-mediated DNA nanotechnology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comprehensive Fe-ligand vibration identification in {FeNO} 6 Hemes

Oriented single-crystal nuclear resonance vibrational spectroscopy (NRVS) has been used to obtain all iron vibrations in two {FeNO} 6 porphyrinate complexes, five-coordinate [Fe(OEP)(NO)]ClO 4 and six-coordinate [Fe(OEP)(2-MeHIm)(NO)]ClO 4 . A new crystal structure was required for measurements of [Fe(OEP)(2-MeHIm)(NO)]ClO 4 , and the new structure is reported herein. Single crystals of both complexes were oriented to be either parallel or perpendicular to the porphyrin plane and/or axial imidazole ligand plane. Thus, the FeNO bending and stretching modes can now be unambiguously assigned; the pattern of shifts in frequency as a function of coordination number can also be determined. The pattern is quite distinct from those found for CO or {FeNO} 7 heme species. This is the result of unchanging Fe–N NO bonding interactions in the {FeNO} 6 species, in distinct contrast to the other diatomic ligand species. DFT calculations were also used to obtain detailed predictions of vibrational modes. Predictions were consistent with the intensity and character found in the experimental spectra. The NRVS data allow the assignment and observation of the challenging to obtain Fe–Im stretch in six-coordinate heme derivatives. Furthermore, NRVS data for this and related six-coordinate hemes with the diatomic ligands CO, NO, and O 2 reveal a strong correlation between the Fe–Im stretch and Fe–N Im bond distance that is detailed for the first time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗