Modified Isotherm Modeling to Predict Cs Exchange with Crystalline Silicotitanate in Tank Waste Simulants

The U.S. Department of Energy is working to expedite processing of Hanford tank waste supernate at the Hanford Waste Treatment and Immobilization Plant. To support this goal, Washington River Protection Solutions is designing a Tank Side Cesium Removal (TSCR) system for suspended solids and cesium (Cs/ 137 Cs) removal from Hanford tank waste supernate. The ion exchange media selected for Cs removal at TSCR is crystalline silicotitanate (CST) that is manufactured in a nearly spherical form by Honeywell UOP LLC (UOP; Des Plaines, IL) as product IONSIV® R9140-B (Na form). The Zheng Anthony Miller (ZAM) isotherm model (Zheng et al. 1997) is a multicomponent ion exchange model used to predict the exchange of Group I metals onto CST. The ZAM isotherm has historically been used to predict Cs distribution values from Hanford and Savannah River Site (SRS) tank waste simulants. Figure S.1 summarizes model predictions from the ZAM isotherm that indicate poor prediction of Cs distribution values for simple and complex simulants with the engineered form of CST, IONSIV® R9140-B, and IONSIV® R9120-B where the solid line indicates a perfect fit by the model. The dotted lines indicate ±20% error. Batch contact testing with Hanford tank waste complex and simple simulants was used in conjunction with SRS simulants to experimentally determine Cs distribution values using a modification to the original isotherm model. The experimentally determined maximum Cs capacity for IONSIV® R9140-B CST in both the simple and complex matrices was found to be 0.53±0.3 mmoles Cs/g of CST. This value is not drastically different from the maximum Cs capacity of 0.58 mmoles Cs/g TAM-5 reported by Zheng et al. (1997). However, it is important to note that TAM-5 (commercially IONSIV® IE-910) is a powder. Hamm et al. (2002) determined that a dilution factor was needed to account for the Zr(OH)2 binder in the engineered form of CST. Hamm et al. determined that a dilution factor of 0.68 was appropriate to account for binder contribution and correct overprediction of Cs exchange on the engineered form of CST in ZAM calculations. This reduced the total capacity from 0.58 mmol/g with TAM-5 to 0.39 mmol/g for the engineered form of CST (Hamm et al. 2002). Despite substituting the experimentally determined maximum Cs capacity of 0.55 mmoles Cs/g for the literature-reported capacity of 0.39 mmoles Cs/g, it was determined that additional modifications to the model’s equilibrium rate constants were necessary in refining the isotherm model. The modified model overpredicted K+ uptake by the CST when compared to digested CST results described by Campbell et al. (2019). The modified model was further revised to omit three of the five K+ exchange equilibrium reactions described by ZAM to reduce the additional K+ loading seen by the model. Figure S.2 summarizes the revised model isotherm predictions plotted against measured Kd values.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Control system for multi-system coordination via a single reference governor

This report describes the improvements to the Feasible Actuator Range Modifier (FARM) component of the RAVEN-based HYBRID framework for analysis of Integrated Energy Systems (IES). FARM supports the HERON plug-in that solves the power dispatch problem. The solution involves economically optimal dispatches that satisfy the limits on production variables and corresponding rates of variation (explicit constraints) as well as the limits on the process variables tied to the service life of equipment (implicit constraints). The problem can be addressed as a two-stage process, i.e., HERON power dispatcher estimates a solution that meets explicit constraints (low-resolution physics), whereas FARM uses the simulation outcomes of HYBRID high-fidelity model to capture the system dynamic response and enforce implicit constraints (high-resolution physics). The initial version of the code (FARM-Alpha) was released by Argonne National Laboratory in January 2021 followed by FARM-Beta (January 2022) and FARM-Gamma (April 2022).

42 ENGINEERING↗

Creating an Inter-Tribal Technical Assistance Network in the Northwest Arctic

The US Department of Energy-Office of Indian Energy's (DOE-IE) support for NANA's establishment of an Inter-Tribal Assistance Network in the Northwest Arctic was a ground-breaking effort that led to many individual community successes and a regional escalation of clean energy for our tribes. Before this grant award was initiated, high penetration renewable-diesel hybrid systems were primarily aspirational. Now, after five years of intensive technical assistance and multi-institution collaboration and funding, the NANA Region has three high penetration solar-wind-battery-diesel hybrid systems and one solar-battery-diesel hybrid system fully operational with diesel-off operation occurring regularly; another solar-battery-diesel hybrid system fully funded with an RFP for construction targeted for 2023; a current grant application that was awarded to begin the final design process for solar-battery-diesel hybrid systems for four other villages in the region; and initial funding to begin a high penetration wind-battery-diesel system for the remaining village in the region. Clearly, our goal to demonstrate and replicate high penetration renewable hybrid technology has been accomplished and is increasing in scale and pace.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

LLNL FY21 NCSP Overview [Slides]

This presentation details the impacts of the COVID-19 pandemic on LLNL in fiscal year 2021, as well as budget information and major accomplishments for the lab in IE, analytical methods, nuclear data, training and education, and IPD.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status Report 2: Advanced Nuclear Reactors Utilized for Synthetic Fuel Creation

Synthetic fuels (synfuels) are hydrocarbon fuels that source energy from electricity. Synfuels have the potential to significantly reduce greenhouse gas emissions throughout the transportation sector. To achieve this substantial reduction in greenhouse gas emissions, the electricity must be sourced from zero- or near-zero-carbon fuel sources such as solar, wind, hydroelectricity, and nuclear power. Synfuels are produced from a combination of carbon and hydrogen sources. Hydrogen can be sourced from water electrolysis with near-zero-carbon electricity and heat (e.g., nuclear), while carbon dioxide can be sourced from ethanol and ammonia plants. In the hydrocarbon fuel synthesis process, hydrogen and carbon dioxide can be reacted to produce carbon monoxide and water, via the so-called reverse watergas shift reaction. Carbon monoxide can then react with additional hydrogen to form hydrocarbons, with carbon chains ranging from C1–C30 in the reaction known as the Fischer-Tropsch (F-T) synthesis reaction. The synthesized hydrocarbon molecules can then be hydro-processed with additional hydrogen and distilled into different carbon chain lengths so as to be compatible with existing conventional gasoline, jet, and diesel fuels. Carbon-free synfuel production comes with a “green premium” over the manufacture of identical products via conventional fossil fuels. Reports from Argonne National Laboratory (ANL) reveal that hydrogen costs dominate the cost of carbon-free synfuel production. This suggests that for the cost of green synfuel to approach that of conventional petroleum fuel, the cost of hydrogen must be approximately $\$1$/kg. Of the primary low-carbon energy sources, only nuclear carries the potential to produce hydrogen at below $\$2$/kg. (Still a bit above the lofty $\$1$/kg goal, but perhaps manageable). To further identify the potential for creating low-cost synfuels capable of competing with legacy technologies, the Department of Energy Office of Nuclear Energy has funded a multi-program, multi-lab effort among ANL, Idaho National Laboratory (INL), the Integrated Energy Systems (IES) program, and the Light Water Reactor Sustainability (LWRS) program. This collaboration effort will determine the possibility of using current and next generation nuclear reactors to create low-cost carbon-free synfuels for sale in the U.S. energy and commodities market.

10 SYNTHETIC FUELS↗

Real-Time Optimization Workflow Status Update

Economically optimal and safe operation of integrated energy systems (IES) requires optimization at many different time scales. A real-time optimization (RTO) workflow will attempt to maximize revenue and minimize operational costs on a time scale of minutes to hours. Such a workflow requires the use of a digital twin (DT), which is a virtual representation of a physical system. The DT is updated using real-time data from the physical system, and serves as a model in an optimization framework. The optimization results are then sent back to the physical system to complete the loop. This report details the progress made in developing building blocks for a DT/RTO framework. The Risk Analysis Virtual Environment (RAVEN) platform within the Framework for Optimization of Resources and Economics (FORCE) tool suite can perform many of the tasks required for building a DT and performing RTO. The first item of this report details RAVEN enhancements that enable RAVEN workflows to be run in various environments. Data communication between the physical system and its DT is essential for successful RTO. This includes preprocessing real-time data, loading data into a data warehouse, and querying the stored data. The second section of this report describes the progress made in implementing an adapter in Python in order for Deep Lynx to handle the data communication. Typical dispatch optimization frameworks are built on linear programming (LP). The prototype RTO workflow developed in this report uses an LP problem as a part of a receding-horizon- or economic model predictive control (EMPC) based optimization. The third section of this report details the framework of an RTO workflow in which the system consists of a simple electrical storage device. A DT can be built from a reduced-order model (ROM). Integrating a ROM into a typical LP optimization framework has been challenging because most optimization packages require the user to write algebraic expressions for the system model. The final section of this report shows how an externally built RAVEN ROM can be integrated in an RTO framework by using the Python package Pyomo. This demonstrates the RTO workflow capability from a software-only perspective and is an important step in demonstrating the capability to implement an RTO workflow for a physical system.

97 MATHEMATICS AND COMPUTING↗

Production of Fischer-Tropsch Synfuels at Nuclear Plants

A case study analysis was performed to evaluate nuclear-powered synthetic fuel production in the midwestern United States (U.S.). A Fischer-Tropsch (FT) fuel synthesis plant design was used as the basis for the analysis. The FT plant design was configured to produce a product slate consisting of diesel fuel, jet fuel, and motor gasoline blend stocks from carbon dioxide (CO 2 ) and hydrogen (H 2 ) feedstocks. The CO 2 feedstock for the FT plant was assumed to be sourced from biorefineries in the region around a Midwest light water reactor (LWR) nuclear power plant (NPP). The analysis specifies that power from the LWR is used to produce H 2 via high-temperature steam electrolysis and to operate the FT synfuel production plant. Capital costs were estimated for the FT plant while capital costs for the electrolysis plant were based on previous Idaho National Laboratory (INL) studies. In addition to labor and maintenance costs for the FT and electrolysis plants, operating costs also include the costs for CO 2 feedstock transport. An analysis was performed to determine the cost of transporting CO 2 from the distributed biorefinery sources to the centralized fuel synthesis plant as a function of the synfuel plant capacity and corresponding CO 2 demand. The primary revenue streams are associated with sales of the synthetic fuel products. The synthetic fuel products will likely follow the same market trends as the conventional fuel products. The synfuel price data was thus based on projections made by the U.S. Energy Information Administration (EIA) 2021 Annual Energy Outlook (AEO) for conventional fuel products minus federal and state taxes, as well as marketing and distribution costs. The economic analysis also considered cases that included and excluded revenues from the 2022 Inflation Reduction Act (IRA) clean hydrogen production tax credit (PTC) of $\$ $3.00/kg for the first ten years of operation. The economic analysis calculated the net present value (NPV) for cases involving steady-state synfuel production for comparison with the NPV for a business-as-usual case in which NPP continues to sell only electric power to the grid. A synfuel production “Reference Case” was considered in addition to sensitivity cases in which the plant capacity, electricity price, and synthetic fuel product prices were perturbed. The synfuel production Reference Case considered a scenario in which the electrolysis and synfuel plants utilized a combined electrical load of 1000 megawatt electrical (MWe) from the LWR with the balance of the LWR power output being sold to the electric grid. The economic analysis suggests that the synfuel production Reference Case evaluated in this analysis would lead to considerable economic potential for near-term deployment of a nuclear-based synfuel production plant. Specifically, the economic analysis suggests that the deployment of a 1000 megawatt (MW) nuclear-powered synfuel plant could result in a NPV increase of approximately $\$ $1.7 billion for a case with no clean synfuel price premium relative to conventional petroleum fuels when accounting for the additional revenues from the 2022 IRA clean hydrogen PTCs of $\$ $3/kg. Sensitivity analysis was performed to evaluate the effect of perturbation of selected model input parameters on the NPV for the synfuel production Reference Case. The sensitivity analysis indicates that the plant capacity has the largest impact on the differential NPV, with a smaller synfuel production capacity resulting in a decrease in revenue when a larger fraction of the power from the NPP is sold to the grid and a smaller fraction of the power is used to produce synthetic fuel products. The synfuel product pricing has the next largest impact on the differential NPV, with lower synfuel prices resulting in decreased NPV from decreased synfuel sales revenue while higher synfuel prices result in increased NPV from increased synfuel sales revenue. Electricity pricing has a smaller effect on the NPV than the fuel sales price since, in the Reference Case, most of the energy from the NPP is used for synfuel production and a smaller amount of the system revenues are associated with electrical power sales. However, the electricity price sensitivity does indicate that the Synfuel Integrated Energy System (IES) would have a greater NPV than the business-as-usual case (e.g., grid power sales only) when electricity market prices are low, suggesting that synfuel production could provide a strategy for decreasing the economic risks to NPPs posed by a loss of revenues attributed to falling electricity market prices.

10 SYNTHETIC FUELS↗

Synthetic Electricity Market Data Generation and HERON Use Case Setup of Advanced Nuclear Reactors Coupled with Thermal Energy Storage Systems

This study evaluates and optimizes advanced nuclear reactors coupled with thermal energy storage (TES) systems in an Integrated Energy System (IES) architecture to enable advanced nuclear power plants (A NPP) to participate in multi-commodity markets, thus enhancing their economic competitiveness. Nuclear-TES coupling scenarios studied herein are designed attenuate the nuclear heat dynamics and defer energy delivery to a later time, enabling the nuclear reactor to continue operating at or near steady-state design conditions as usual while also enabling flexible generation. Three A-NPPs, namely, an advanced light-water reactor (A LWR), a high temperature gas-cooled reactor (HTGR) and a liquid-metal fast reactor (LMFR) were selected as the initial use cases for demonstrating the technoeconomic of thermally balanced energy storage coupling design for thermal power extraction. Each of the reactor technologies were evaluated in two different electricity markets. Stochastic optimization approach was adopted which included the evaluation of price signals from the Pennsylvania-New Jersey-Maryland (PJM) market, and Electric Reliability Council of Texas (ERCOT), using an autoregressive moving average (ARMA) model. Risk Analysis Virtual Environment (RAVEN) tool and its dispatch optimization plugin, the Holistic Energy Resource Optimization Network (HERON), were used to perform dispatch and capacity optimization, using the price data provided by the ARMA models. The results from the Nuclear-TES use cases will be used to design and characterize dynamic integrated system behavior and feedback.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Technoeconomic Evaluation of Solid Oxide Fuel Cell Hydrogen-Electricity Co-Generation Concepts

This report evaluates the cost and performance of several types of Integrated Energy Systems (IES) based on solid oxide fuel cells (SOFCs) to generate power and solid oxide electrolysis cells (SOECs) to produce hydrogen. All cases feature carbon capture at rates exceeding 97 percent. The report also describes the development of optimized steady state process models for each system. These are used to calculate overall electricity and hydrogen production costs using a consistent methodology that facilitates comparisons of these cases to one another and to prior NETL cost and performance estimates. The SOFC and SOEC costs and performance are based on nth-of-a-kind systems and include research and development and learning associated with mass-scale commercial deployment of the technology over the next decade required for commercial utility-scale systems.

08 HYDROGEN↗

HYBRID Modeling of DETAIL Experimental Facility

Idaho National Laboratory continues to be at the forefront of advanced reactor systems and integrated energy systems research. Through the Thermal Energy Distribution System (TEDS) and Microreactor Agile Non-nuclear Test Bed (MAGNET) experiments in the Dynamic Energy Transport and Innovation Laboratory (DETAIL) within the Engineering Systems Laboratory, a mix of digital and physical testing systems can explore the operation of thermally and electrically integrated systems. Modeling of these systems has been done using the HYBRID modeling repository of the Integrated Energy Systems program. DETAIL also contains high temperature steam electrolysis (HTSE) units to produce hydrogen and generate the load imposed on MAGNET and TEDS. The dynamic modeling capabilities within the IES program describe the DETAIL components as-built and can be used to evaluate controls, process flows, and overall system conditions.

08 HYDROGEN↗

Thermal Extraction Modeling within HYBRID: Nominal and Extraction Conditions in Advanced Reactor Systems

This document details continuing development of thermal extraction modeling within the HYBRID repository, the modeling repository of the Integrated Energy Systems program at Idaho National Laboratory. The focus of the thermal extraction work is setting up template energy conversion systems for advanced reactor systems. Based on these nominal conditions, the IES team is developing extraction capability maps that present the system thermal-to-electric efficiency of the remaining system and the mass extraction fraction capability of these systems when extracting steam at various pressures to send steam to applications at a lower given pressure. These curves are mapped on what has become termed “whale chart” due to the appearance of the results. Multiple advanced reactor systems are complete, and it is anticipated that all four of the main advanced reactor types: advanced light-water reactors, high temperature gas reactors, liquid metal fast reactors, and molten salt reactors, will be complete by the end of the fiscal year.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A portable ion-energy diagnostic for transformative ARPA-E Fusion R&D

The Princeton Plasma Physics Laboratory seeks to develop a diagnostic to measure the energy distribution of ions (IED) in innovative confinement concept devices being investigated under ARAP-E grants. The Princeton Field-Reversed Configuration (PFRC) fusion project aims to develop small, simple, and clean fusion power generators in the 1–10 MW “micro-reactor” class. The PFRC explores a new approach to fusion power-generation design, prioritizing low radioactivity and modular units of MEW-scale power output. The team’s proposed power plant design provides a small footprint for a compact, potentially transportable energy source that is fully deployable and emissions-free. A critical diagnostic to accomplish this mission and to test the theory of ion heating necessary for fusion in PFRC reactors is called a stripping-cell ion-energy analyzer (SC-IEA).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Digital Twin Development of FASTR

This work package is focused on creating a digital twin (DT) of the Facility to Alleviate Salt Technology Risks (FASTR) experiment. FASTR is a high-profile facility tasked with maturing molten salt applications such as liquid salt energy storage, concentrated solar power facilities, and molten salt cooling systems supporting other advanced reactor technologies, all of which may be incorporated as components within the Integrated Energy Systems (IES) program. As part of creating a digital twin (DT), verification and validation (V&V) has been performed for the physics-based model, and gaps have been identified. Additionally, a preliminary integration of the FASTR model has been completed with the existing physics-based model of the Thermal Energy Distribution System (TEDS)/Microreactor AGile Non-nuclear Experimental Testbed (MAGNET) facility at Idaho National Laboratory (INL). A Functional Mock-up Unit (FMU) of the physics-based system model and a reduced-order model (ROM) were both used to test for a preliminary hardware in the loop operation when the physical loop was offline. Future tasks could include improving the physics-based model to better match the available experimental data, improving the hardware in the loop integration, and improving the integration with the TEDS model.

14 SOLAR ENERGY↗

Signal Decomposition for Intrusion Detection in Reliability Assessment in Cyber Resilience (Summary Report)

The complexity of assuring cyber resilience for physical process interactions in connected systems such as energy grids increases dramatically as the coupling between processes becomes more direct and responsive. An example of this growing complexity is provided by Integrated Energy Systems (IES), in which various processes such as nuclear heat generation and commodity production are being directly coupled for increased responsiveness to highly variable signals such as market pricing or electricity demand. As such, the potential attack surface of the coupled processes is larger than the two processes independently. Securing these complex systems requires two-fold monitoring: cybersecure monitoring for potential malicious incursion, and physics monitoring for system tampering. Physics monitoring includes analyzing the behavior of the signals within the system for anomalous behavior. This analysis has been shown to be insufficient if approached by only data-driven machine learning and artificial intelligence (MLAI) techniques or only low-level model comparison. Previous efforts at Purdue University suggested combining high-fidelity models with MLAI algorithms as a basis for a software tool for detecting anomalies in physical processes. This work built on that suggestion, developing an advanced library for signal decomposition and analysis using both MLAI and high-fidelity physics algorithms for greatly improved anomaly detection, especially false data injection. This software can be used as part of a secure imbedded intelligence (SEI) system designed under Consequence-driven Cyber-informed Engineering (CCE) for complex coupled systems. This library established a foundation for online and posteriori analysis of digital signals for the purpose of detecting potential malicious tampering in digital signals representing physical processes. Demonstrations carried out throughout the development highlight the effective use of characterization algorithms to detect signal perturbations, particularly triangle attack-style perturbations, in three wide-ranging applications: seismic monitoring, nuclear thermal hydraulics system simulation, and custom manufacturing.

97 MATHEMATICS AND COMPUTING↗

Full Technical Report: High-Rate Carbide Growth by Evaporation

Boron carbide (B 4 C) is an attractive inertial confined fusion (ICF) ablator and a unique ultra-hard material with numerous current and potential applications. What makes B 4 C attractive as an ablator is its relatively high density and the ability to form a stable glassy phase combined with excellent chemical and mechanical stability. Despite these advantages, the fabrication of B 4 C ablators has remained a challenge. Magnetron sputtering, our current frontrunner approach for B 4 C deposition, exhibits low deposition rates (< 2 μm/h) and undesirable nodular defects within the film structure that are believed to generate from the dusty plasma around the sputtering source. The goals of this project were to (1) establish alternative plasma-free, electron beam evaporation (EBE) capabilities for the deposition of thin films that are needed in mission-critical programs and; (2) demonstrate the feasibility to deposit B 4 C films at high rates by EBE in a bottom-up geometry and characterize their stoichiometry. In this feasibility study, we initially developed the capability to convert a general-use vacuum chamber into an electron beam evaporator as needed, or on demand. Then, we successfully used this setup to deposit films made of boron carbide and various other materials. By adjusting the deposition parameters and the evaporation source material, we were able to demonstrate the feasibility of reaching deposition rates as high as 8 μm/h, which is about 4 times the maximum rates obtained through sputtering methods. We predict that these values can still be further improved by implementing enhanced thermal control measures for the target source and optimizing electron beam parameters (ie. current, sweeping and frequency) since ceramic materials with similar densities to B 4 C can exhibit deposition rates of about twice this value. We anticipate that the skills and capabilities developed throughout this project will prove relevant not only to the HED and ICF campaigns but also to numerous existing and prospective applications focused on the development of ultra-hard carbide coatings. The fresh set of tools here developed will also facilitate the preparation and research on future new target materials of interest beyond B 4 C.

36 MATERIALS SCIENCE↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report (DOE 2023) provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

42 ENGINEERING↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗