Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High Frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Method of measuring elastic strain distribution in specimens used for high frequency fatigue testing

A technique using a point contact piezoelectric detector has been developed which permits the displacement amplitude distributions over the entire length of high frequency fatigue specimens to be measured. Elastic strain distributions can be derived with a computer analysis that uses curve smoothing and numerical derivative methods. The equipment and techniques for measuring and processing the data are described, and displacement amplitudes, strain distributions, and magnification factors for straight rods and dumbbell-shaped specimens are obtained and shown to agree with theoretically predicted values. It is shown that the technique presented here can be used to design specimens with unusual displacement amplitudes and strain distributions.

Sirian, C. R.↗

Carbon nanotube Schottky diodes using Ti-Schottky and Pt-ohmic contacts for high frequency applications

We have demonstrated Schottky diodes using semiconducting single-walled nanotubes (s-SWNTs) with titanium Schottky and platinum Ohmic contacts for high-frequency applications. The diodes are fabricated using angled evaporation of dissimilar metal contacts over an s-SWNT. The devices demonstrate rectifying behavior with large reverse bias breakdown voltages of greater than 15 V. To decrease the series resistance, multiple SWNTs are grown in parallel in a single device, and the metallic tubes are burnt-out selectively. At low biases these diodes showed ideality factors in the range of 1.5 to 1.9. Modeling of these diodes as direct detectors at room temperature at 2.5 terahertz (THz) frequency indicates noise equivalent powers (NEP) potentially comparable to that of the state-of-the-art gallium arsenide solid-state Schottky diodes, in the range of 10-13 W(square root)xHz.

semiconducting↗

Magnetic and high frequency properties of nanogranular CoFe-TiO{sub 2} films

A series of soft magnetic nanogranular CoFe-TiO{sub 2} films with different thicknesses were fabricated on Si substrates by co-sputtering CoFe and TiO{sub 2}, and the magnetic and high frequency properties were studied in details. X-ray diffraction analysis confirmed that the films were nanocrystalline/amorphous composites. A saturation magnetization as high as 21 kGs and a ferromagnetic resonance (FMR) frequency above 3 GHz were obtained. It was found that the coercivity decreased steeply with the increase of film thickness and its minimum value was about 6 Oe. In addition, the variations of FMR peak broadness of the imaginary part and damping factor were also presented and discussed as functions of film thickness.

36 MATERIALS SCIENCE↗

Transversely driven coherent beam oscillations and specifications for high-frequency ESR dipole power supply current ripple

We study coherent transverse beam oscillations in the EIC electron storage ring (ESR), to specify the tolerance for high-frequency ripple of the dipole magnet power supplies. To avoid unacceptable proton emittance growth from the oscillating beam-beam kick from the electrons, the amplitude of these oscillations at the proton betatron frequency needs to be limited to about 1e-4 fraction of the beam size at the interaction point. We show that the oscillations potentially caused by the ESR magnet dipole power supply ripple could be substantial, but still tolerable, if we account for the eddy current shielding in the vacuum chamber.

43 PARTICLE ACCELERATORS↗

Investigation of potential driver modules and transmission lines for a high frequency power system on the space station

The objective was to assess the feasibility of using the Series Resonant inverter as the driver module for the high frequency power system on the Space Station. This study evaluates the performance of the Series Resonant driver when it was operated with a dc input voltage and run through a series of tests to determine its start-up performance, response to load changes, load regulation, and efficiency. Also, this study compares the Series Resonant driver to another kind of driver that uses a Power Transistor snubber. An investigation of the various types of transmission lines is initiated. In particular, a simplified approach is utilized to describe the optimal transmission line.

Brush, H. T.↗

Nonlinear evolution of high frequency R-mode waves excited by water group ions near comets - Computer experiments

An ion beam resonates with R-mode waves at a high-frequency RH mode and a low-frequency RL mode. The nonlinear evolution of ion beam-generated RH waves is studied here by one-dimensional hybrid computer experiments. Both wave-particle and subsequent wave-wave interactions are examined. The competing process among coexisting RH and RL mode beam instabilities and repeated decay instabilities triggered by the beam-excited RH mode waves is clarified. It is found that the quenching of the RH instability is not caused by a thermal spreading of the ion beam, but by the nonlinear wave-wave coupling process. The growing RH waves become unstable against the decay instability. This instability involves a backward-traveling RH electromagnetic wave and a forward-traveling longitudinal sound wave. The inverse cascading process is found to occur faster than the growth of the RL mode. Wave spectra decaying from the RH waves weaken as time elapses and the RL mode waves become dominant at the end of the computer experiment.

Kojima, H.↗

High frequency flow-structural interaction in dense subsonic fluids

Prediction of the detailed dynamic behavior in rocket propellant feed systems and engines and other such high-energy fluid systems requires precise analysis to assure structural performance. Designs sometimes require placement of bluff bodies in a flow passage. Additionally, there are flexibilities in ducts, liners, and piping systems. A design handbook and interactive data base have been developed for assessing flow/structural interactions to be used as a tool in design and development, to evaluate applicable geometries before problems develop, or to eliminate or minimize problems with existing hardware. This is a compilation of analytical/empirical data and techniques to evaluate detailed dynamic characteristics of both the fluid and structures. These techniques have direct applicability to rocket engine internal flow passages, hot gas drive systems, and vehicle propellant feed systems. Organization of the handbook is by basic geometries for estimating Strouhal numbers, added mass effects, mode shapes for various end constraints, critical onset flow conditions, and possible structural response amplitudes. Emphasis is on dense fluids and high structural loading potential for fatigue at low subsonic flow speeds where high-frequency excitations are possible. Avoidance and corrective measure illustrations are presented together with analytical curve fits for predictions compiled from a comprehensive data base.

Liu, Baw-Lin↗

Super-high-frequency shielding properties of excimer-laser-synthesized-single-wall-carbon-nanotubes/polyurethane nanocomposite films

Electromagnetic shielding attenuation (ESA) properties of carbon nanotubes/polymer nanocomposite films, in the super high frequency (SHF) X-band (7-12 GHz) domain are studied. The nanocomposite films consisted of thermoset polyurethane (PU) resin blended with single-walled carbon nanotubes (SWCNTs) mats, and deposited on fused quartz substrates. Two different approaches were used to achieve the nanocomposite films, namely (i) through the on-substrate ''all-laser'' growth approach of SWCNTs directly onto substrate, followed by their infiltration by the PU resin, and (ii) by appropriately dispersing the chemically-purified SWCNTs (in the soot form) into the PU matrix and their subsequent deposition onto quartz substrates by means of a solvent casting process. Characterizations of the ESA properties of the developed nanocomposite films show that they exhibit systematically a deep shielding band, centered at around 9.5 GHz, with an attenuation as high as |- 30| dB, recorded for SWCNT loads of 2.5 wt. % and above. A direct correlation is established between the electrical conductivity of the nanocomposite films and their electromagnetic shielding capacity. The SWCNTs/PU nanocomposites developed here are highly promising shielding materials as SHF notch filters, as their ESA capacity largely exceeds the target value of |- 20| dB generally requested for commercial applications.

36 MATERIALS SCIENCE↗

High frequency gravitational wave sensing with superconducting microwave cavities

A promising way to probe physics beyond the Standard Model is to search for gravitational wave (GW) signals at high frequencies where known astrophysical sources can not obscure the signal. Similar to the search for dark matter, microwave cavity resonators can be used to detect faint effects from GWs. We will report on the progress of our project to operate such a detector and highlight improvements we are planning in the future. This includes quantum enhancement techniques like vacuum squeezing which will allow future detectors to operate beyond the standard quantum limit.

Marconato, Giovanni [Hamburg U.]↗

High frequency atomic tunneling yields ultralow and glass-like thermal conductivity in chalcogenide single crystals

Crystalline solids exhibiting glass-like thermal conductivity have attracted substantial attention both for fundamental interest and applications such as thermoelectrics. In most crystals, the competition of phonon scattering by anharmonic interactions and crystalline imperfections leads to a non-monotonic trend of thermal conductivity with temperature. Defect-free crystals that exhibit the glassy trend of low thermal conductivity with a monotonic increase with temperature are desirable because they are intrinsically thermally insulating while retaining useful properties of perfect crystals. However, this behavior is rare, and its microscopic origin remains unclear. Here, we report the observation of ultralow and glass-like thermal conductivity in a hexagonal perovskite chalcogenide single crystal, BaTiS 3 , despite its highly symmetric and simple primitive cell. Elastic and inelastic scattering measurements reveal the quantum mechanical origin of this unusual trend. A two-level atomic tunneling system exists in a shallow double-well potential of the Ti atom and is of sufficiently high frequency to scatter heat-carrying phonons up to room temperature. While atomic tunneling has been invoked to explain the low-temperature thermal conductivity of solids for decades, our study establishes the presence of sub-THz frequency tunneling systems even in high-quality, electrically insulating single crystals, leading to anomalous transport properties well above cryogenic temperatures.

36 MATERIALS SCIENCE↗

A Schwarz generalized eigen-oscillation spectral element method (GeSEM) for 2-D high frequency electromagnetic scattering in dispersive inhomogeneous media

In this paper, we propose a parallel Schwarz generalized eigen-oscillation spectral element method (GeSEM) for 2-D complex Helmholtz equations in high frequency wave scattering in dispersive inhomogeneous media. This method is based on the spectral expansion of complex generalized eigen-oscillations for the electromagnetic fields and the Schwarz non-overlapping domain decomposition iteration method. The GeSEM takes advantages of a special real orthogonality property of the complex eigen-oscillations and a new radiation interface condition for the system of equations for the spectral expansion coefficients. Numerical results validate the high resolution and the flexibility of the method for various materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental evidence of high-frequency complete elastic bandgap in pillar-based phononic slabs

We present strong experimental evidence for the existence of a complete phononic bandgap, for Lamb waves, in the high frequency regime (i.e., 800 MHz) for a pillar-based phononic crystal (PnC) membrane with a triangular lattice of gold pillars on top. The membrane is composed of an aluminum nitride film stacked on thin molybdenum and silicon layers. Experimental characterization shows a large attenuation of at least 20 dB in the three major crystallographic directions of the PnC lattice in the frequency range of 760 MHz–820 MHz, which is in agreement with our finite element simulations of the PnC bandgap. The results of experiments are analyzed and the physics behind the attenuation in different spectral windows is explained methodically by assessing the type of Bloch modes and the in-plane symmetry of the displacement profile.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Parallel high-frequency magnetic sensing with an array of flux transformers and multi-channel optically pumped magnetometer for hand MRI application

Here, we investigate an approach for parallel high-frequency magnetic sensing based on a multi-channel radio frequency (RF) optically pumped magnetometer (OPM) coupled to multiple flux transformers (FTs) with a focus on hand magnetic resonance imaging (MRI) application at ultra-low field (ULF). Multiple RF OPM sensing channels are realized by using a single large-area alkali-metal vapor cell and two laser beams for pumping and probing, shared for all the channels. This design leads to significant cost reduction when multi-channel sensing is desirable, as in the case of ULF MRI. The FT, composed of two connected coils, serves as a transmitter of a target magnetic field to the OPM, while decoupling the OPM from untargeted magnetic fields in the sensing area that can limit the OPM performance. For hand MRI application, theoretical and numerical analysis is performed to determine an optimal geometry for the FT array that could improve signal-to-noise ratio (SNR) and sufficiently reduce crosstalk between FTs. We estimate that the optimized multi-channel FT-OPM sensor can achieve a magnetic field sensitivity of the order of 1 fT / Hz 1 / 2 above 100 kHz, which would be sufficient for 1 mm resolution MRI. In general, the multi-channel capability enables simultaneous magnetic measurements, thus reducing the sensing time and improving the SNR, and we anticipate many applications of the multi-channel FT-OPM sensor beyond the targeted here hand MRI: anatomical parallel ULF MRI of the human brain and other parts of the body, airport security screening, magnetic material imaging, and many others.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Energy Consumption for High-Frequency Switching of a Quantum-Dot Microdisk Laser

We have studied characteristics of a 23-μm-diameter microdisk laser operating in a regime of direct high-frequency modulation at a stabilized heat-sink temperature of 18°C. It is found that the minimum energy consumption in this regime amounts to ~1.6 pJ/bit and is achieved at a modulation frequency of 4.2 GHz. The maximum modulation frequency is 6.7 GHz, at which the minimum energy consumption is 3.3 pJ/bit.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-Frequency 3D Photoacoustic Computed Tomography Using an Optical Microring Resonator

3D photoacoustic computed tomography (3D-PACT) has made great advances in volumetric imaging of biological tissues, with high spatial-temporal resolutions and large penetration depth. The development of 3D-PACT requires high-performance acoustic sensors with a small size, large detection bandwidth, and high sensitivity. In this work, we present a new high-frequency 3D-PACT system that uses a microring resonator (MRR) as the acoustic sensor. The MRR sensor has a size of 80 μ m in diameter and was fabricated using the nanoimprint lithography technology. Using the MRR sensor, we have developed a transmission-mode 3D-PACT system that has achieved a detection bandwidth of ~23 MHz, an imaging depth of ~8 mm, a lateral resolution of 114 μ m, and an axial resolution of 57 μ m. We have demonstrated the 3D PACT’s performance on in vitro phantoms, ex vivo mouse brain, and in vivo mouse ear and tadpole. The MRR-based 3D-PACT system can be a promising tool for structural, functional, and molecular imaging of biological tissues at depths.

47 OTHER INSTRUMENTATION↗