Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HEAT repeats”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Development and Implementation of Aseptic Operations for the MOMA-Mass Spectrometer

The ExoMars 2020 Rover is a life detection mission, and is classified as Planetary Protection (PP) Mission Category IVb, the first IVb mission since the Viking missions. Mars Organic Molecule Analyzer Mass Spectrometer (MOMA-MS) is a life detection instrument for the rover. To meet the stringent bioburden requirement of 0.03 spore/m2, the MS is subjected to Dry Heat Microbial Reduction (DHMR) to decrease the bioburden from a measured 88 spores/m2 to 0.009 spores/m2. After DHMR, exposure of the sample path must be kept to an absolute minimum and requires aseptic operations. Aseptic operations include determining the safe exposure time based on the surface area of exposure and particle fallout expected in the aseptic ISO class 5 workspace, preparing an aseptic ISO class 5 workspace, and using sterile garments and tools. During the exposure activity the environment is monitored with active and passive fallout for bioburden and real time airborne particle counts. Sterile tools are handled by a two person team so the operator touches only the tool and not the exterior surfaces of the sterilization pouch, and a sterile operating field is established as a safe place to organize tools or parts during the aseptic operations. In cases where aseptic operations are not feasible, localized DHMR is used after exposure. Any breach in the PP cleanliness can necessitate repeating instrument level DHMR, which not only has significant cost and schedule implications, but also is a risk to hardware that is not rated for repeated long exposures to high temperatures.

Aseptic processing↗

Efforts to Reduce International Space Station Crew Maintenance for the Management of the Extravehicular Mobility Unit Transport Loop Water Quality

The EMU (Extravehicular Mobility Unit) contains a semi-closed-loop re-circulating water circuit (Transport Loop) to absorb heat into a LCVG (Liquid Coolant and Ventilation Garment) worn by the astronaut. A second, single-pass water circuit (Feed-water Loop) provides water to a cooling device (Sublimator) containing porous plates, and that water sublimates through the porous plates to space vacuum. The cooling effect from the sublimation of this water translates to a cooling of the LCVG water that circulates through the Sublimator. The quality of the EMU Transport Loop water is maintained through the use of a water processing kit (ALCLR Airlock Cooling Loop Remediation) that is used to periodically clean and disinfect the water circuit. Opportunities to reduce crew time associated with on-orbit ALCLR operations include a detailed review of the historical water quality data for evidence to support an extension to the implementation cycle. Furthermore, an EMU returned after 2-years of use on the ISS (International Space Station) is being used as a test bed to evaluate the results of extended and repeated ALCLR implementation cycles. Finally, design, use and on-orbit location enhancements to the ALCLR kit components are being considered to allow the implementation cycle to occur in parallel with other EMU maintenance and check-out activities, and to extend the life of the ALCLR kit components. These efforts are undertaken to reduce the crew-time and logistics burdens for the EMU, while ensuring the long-term health of the EMU water circuits for a post-Shuttle 6-year service life.

Steele, John W.↗

Wehnelt photoemission in an ultrafast electron microscope: Stability and usability

We tested and compared the stability and usability of three different cathode materials and configurations in a thermionic-based ultrafast electron microscope: (1) on-axis thermionic and photoemission from a custom 100 μm diameter LaB 6 source with a graphite guard ring, (2) off-axis photoemission from the Ni aperture surface of the Wehnelt electrode, and (3) on-axis thermionic and photoemission from a custom 200 μm diameter polycrystalline Ta source. For each cathode type and configuration, including the Ni Wehnelt aperture, we illustrate how the photoelectron beam-current stability is deleteriously impacted by simultaneous cooling of the source following thermionic heating. Furthermore, we demonstrate usability via collection of parallel- and convergent-beam electron diffraction patterns and by formation of the optimum probe size. We find that usability of the off-axis Ni Wehnelt-aperture photoemission is at least comparable to on-axis LaB 6 thermionic emission, as well as to on-axis photoemission [the heretofore conventional approach to ultrafast electron microscopy (UEM) in thermionic-based instruments]. However, the stability and achievable beam currents for off-axis photoemission from the Wehnelt aperture were superior to that of the other cathode types and configurations, regardless of the electron-emission mechanism. Beam-current stability for this configuration was found to be ±1% (one standard deviation from the mean) for 70 min (longest duration tested), and steady-state beam current was reached within the sampling-time resolution used here (~1 s) for 15 pA beam currents (i.e., 460 electrons per packet for a 200 kHz repetition rate). Repeatability and robustness of the steady-state condition were also found to be within ±1% of the mean. We discuss the implications of these findings for UEM imaging and diffraction experiments, for pulsed-beam damage measurements, and for practical switching between optimum conventional TEM and UEM operation within the same instrument.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Axon-like active signal transmission

Any electrical signal propagating in a metallic conductor loses amplitude due to the natural resistance of the metal. Compensating for such losses presently requires repeatedly breaking the conductor and interposing amplifiers that consume and regenerate the signal. This century-old primitive severely constrains the design and performance of modern interconnect-dense chips. Here we present a fundamentally different primitive based on semi-stable edge of chaos (EOC), a long-theorized but experimentally elusive regime that underlies active (self-amplifying) transmission in biological axons. By electrically accessing the spin crossover in LaCoO 3 , we isolate semi-stable EOC, characterized by small-signal negative resistance and amplification of perturbations. In a metallic line atop a medium biased at EOC, a signal input at one end exits the other end amplified, without passing through a separate amplifying component. While superficially resembling superconductivity, active transmission offers controllably amplified time-varying small-signal propagation at normal temperature and pressure, but requires an electrically energized EOC medium. Operando thermal mapping reveals the mechanism of amplification—bias energy of the EOC medium, instead of fully dissipating as heat, is partly used to amplify signals in the metallic line, thereby enabling spatially continuous active transmission, which could transform the design and performance of complex electronic chips.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and Joule-Thomson and Stirling cryocoolers to reduce heat load on the He tank supporting the ADRs. Resolve was designed with tunable cryocooler drive frequencies so that interference could be avoided. The cryocooler generated micro-vibration changes with drive frequency and that micro-vibration causes interference and degrades instrument performance. Poor drive frequency choices have been shown to dramatically impact ADR cooling power, temperature stability, detector noise, and degrading spectroscopic performance. However, some choices are free of these features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is critical to achieving peak instrument performance. The drive frequencies of the Joule-Thomson cooler, near 52 Hz, and the Stirling coolers, near 15 Hz, were adjusted in three scan sequences while measuring interference to narrow candidate frequency options. Choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. These scans were performed routinely during ground testing. Surprisingly though, the results were not repeatable after the Dewar was warmed and re-cooled but were repeatable when remeasured during the same test campaign. Since the good/bad drive frequencies change during Dewar warmup/cooldown, and possibly after vibration events, the drive frequencies could not be finalized before launch. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

XRISM↗

Development of a Device to Deploy Fluid Droplets in Microgravity

A free-floating droplet in microgravity is ideal for scientific observation since it is free of confounding factors such as wetting and nonsymmetrical heat transfer introduced by contact with surfaces. However, the technology to reliably deploy in microgravity has not yet been developed. In some recent fluid deployment experiments, droplets are either shaken off the dispenser or the dispenser is quickly retracted from the droplet. These solutions impart random residual motion to deployed droplet, which can be undesirable for certain investigations. In the present study, two new types of droplet injectors were built and tested. Testing of the droplet injectors consisted of neutral buoyancy tank tests, 5-sec drop tower tests at the NASA Lewis Zero Gravity Facility, and DC-9 tests. One type, the concentric injector, worked well in the neutral buoyancy tank but did not do well in low-gravity. However, it appeared that it makes a fine apparatus for constructing bubbles in low-gravity conditions. The other type, the T-injector, showed the most promise for future development. In both neutral buoyancy and DC-9 tests, water droplets were formed and deployed with some control and repeatability, although in low-gravity the residual velocities were higher than desirable. Based on our observations, further refinements are suggested for future development work.

Robinson, David W.↗

Novel Approach to Quantification of Telomere Length with Direct Nanopore Sequencing and PCR Amplification

The ends of human chromosomes contain telomeres, or tandem arrays of repeating DNA sequences capped by multiple associated proteins that protect chromosomal ends from degradation. Telomeres function to preserve genomic stability by preventing natural chromosomal ends from being recognized as broken DNA double-strand breaks and triggering inappropriate DNA damage responses. Mounting evidence shows telomere length is an inherited trait that decreases with cellular division and normal aging. In addition, telomere length also appears to be influenced by other factors such as cellular oxidative stress, radiation and mechanical unloading of tissues as in microgravity. To measure these potential effects of the space environment on telomere lengths and cellular aging and regenerative potential we developed a novel telomere measurement approach based on nanopore sequencing of PCR amplified bar-coded chromosome termini. Specifically, telomeres can be directly enriched using barcode sequences ligated to the end of a free end- repaired telomere using the WetLab-2 facility SmartCycler on ISS. Prior to the ligation and amplification protocol a proteinase K digestion of capping proteins followed by a single 95-degree C heat denaturation of the protease is included. After digestion and bar-code ligation, PCR amplification will initiate with the ligated barcoded sequence, suppressing amplification of intra-genomic fragments and resulting in long read barcoded telomere amplicons including the nanopore motor protein sequences. Purified PCR amplicons are then used for nanopore sequencing library generation by simple addition of motor proteins and sequencing library is loaded into the MinION nanopore DNA-sequencer. Amplicon sequence reads from the nanopore device can be base-called quickly on ISS due to barcoding ligation and subsequent PCR amplification enhancing the telomere sequence resolution. If successfully implemented on ISS this technique will provide a novel means of measuring regenerative ability of somatic stem cells in astronauts, and of determining whether spaceflight in microgravity alters their telomere lengths and causes premature cellular aging.

Ma, Kristin R.↗

Aseptic Handling of the MOMA Mass Spectrometer After Dry Heat Microbial Reduction

Mars Organic Molecule Analyzer Mass Spectrometer (MOMA-MS) is an instrument in the larger MOMA instrument suite for the European Space Agency (ESA) ExoMars 2020 Rover. As a life-detection instrument on a Mars landing mission, MOMA-MS has very stringent Planetary Protection (PP) bioburden requirements. Within the MOMA instrument suite, the hardware surfaces of the sample path must be cleaned to a level of 0.03 spore/sq m. To meet this requirement, a process called Dry Heat Microbial Reduction (DHMR) is used to decrease the number of viable spores by 4 orders of magnitude. Before DHMR, the hardware is handled using standard cleanroom practices, while after DHMR, all sample path surfaces must be handled aseptically when exposed. Aseptic handling of the sample path involves a number of strategies and protocols including working only in an aseptic ISO class 5 work space, limiting the amount of time of exposure, using sterile garmenting with sterile gloves, and using sterile tools. Before work begins, the aseptic workspace will be tested for bioburden and particle fallout, and all tools that will contact sample path surfaces must be sterilized. During the exposure activity, sterile garments will be worn, sterile tools will be handled in a 2 person set up so that the operator touches only the sterile tool and not the exterior surfaces of the sterile pouch, and the environment will be monitored with active and passive fallout for bioburden and particle levels. Any breach in the planetary protection cleanliness can necessitate repeating DHMR, which not only has significant cost and schedule implications, it also become a risk to hardware that is not rated for repeated long exposures to high temperatures.

Life Detection↗

Going Places No Infrared Temperature Devices Have Gone Before

Exergen's IRt/c is a self-powered sensor that matches a thermocouple within specified temperature ranges and provides a predictable and repeatable signal outside of this specified range. Possessing an extremely fast time constant, the infrared technology allows users to measure product temperature without touching the product. The IRt/c uses a device called a thermopile to measure temperature and generate current. Traditionally, these devices are not available in a size that would be compatible with the Exergen IRt/c, based on NASA s quarterinch specifications. After going through five circuit designs to find a thermopile that would suit the IRt/c design and match the signal needed for output, Exergen maintains that it developed a model that totaled just 20 percent of the volume of the previous smallest detector in the world. Following completion of the project with Glenn, Exergen continued development of the IRt/c for other customers, spinning off a new product line called the micro IRt/c. This latest development has broadened applications for industries that previously could not use infrared thermometers due to size constraints. The first commercial use of the micro IRt/c involved an original equipment manufacturer that makes laminating machinery consisting of heated rollers in very tight spots. Accurate temperature measurement for this application requires close proximity to the heated rollers. With the micro IRt/c s 50-millisecond time constant, the manufacturer is able to gain closer access to the intended temperature targets for exact readings, thereby increasing productivity and staying ahead of competition.In a separate application, the infrared temperature sensor is being utilized for avalanche warnings in Switzerland. The IRt/c is mounted about 5 meters above the ground to measure the snow cover throughout the mountainous regions of the country.

Source record↗

Software For Advanced Large-scale Analysis Of Magnetic Confinement For Numerical Design, Engineering & Research (salamander)

As magnetic confinement fusion energy gains traction internationally to enable abundant energy production, designing components for fusion systems is a pressing challenge. During the planned lifetime of a fusion device, components evolve in extreme environments and must withstand large, repeated thermal loads and bombardment by 14 MeV neutrons, plasma ions, and neutral particles (deuterium, tritium, and helium), corrosive conditions, etc. All these physical processes take place simultaneously, interact in intricate ways, and impose important constraints that can affect performance. Experimental data is rare and costly to obtain, making design particularly challenging. Predictive computational frameworks must be an integral part of an accelerated and cost-effective design process by modeling fusion system performance in simulated environments. To better understand component degradation and operational impacts on their performance, the Software for Advanced Large-scale Analysis of MAgnetic confinement for Numerical Design, Engineering & Research (SALAMANDER) is designed as an open-source, fully integrated, multiphysics, multiscale, NQA-1 compliant framework facilitating 3D, high-fidelity fusion system modeling. To that end, SALAMANDER is a MOOSE-based framework, and therefore leverages MOOSE upstream libraries such as PETSc and libMesh to deliver sophisticated finite element, finite volume, and nonlinear solver technology for fusion energy simulations. SALAMANDER couples MOOSE physics module capabilities—such as thermal hydraulics, heat conduction, Navier-Stokes, and thermomechanics—with tritium transport via TMAP8, neutronics via Cardinal, and nascent particle-in-cell capabilities. Direct simulation Monte Carlo methods will be used to address neutral transport near the walls. By coupling all these physics in an integrated application, SALAMANDER will enable high-fidelity modeling of irradiation levels and plasma exposure conditions of plasma facing components and their impact on heat and tritium distributions, as well as the resulting mechanical constraints experienced by the plasma facing components and performance of blanket systems. Furthermore, SALAMANDER will be particularly suited for engineering studies thanks to the stochastic tool module readily available in MOOSE, allowing for extended uncertainty quantification and risk analysis studies. It is also able to use computer-aided design (CAD) meshes to model complex geometries, which is indispensable for fusion systems. SALAMANDER therefore supports design, safety, engineering, and research projects for magnetic confinement fusion systems

Simon, Pierre-Clement [Idaho National Laboratory (↗

Materials Combustion Testing and Combustion Product Sensor Evaluations in FY12

NASA Centers continue to collaborate to characterize the chemical species and smoke particles generated by the combustion of current space-rated non-metallic materials including fluoropolymers. This paper describes the results of tests conducted February through September 2012 to identify optimal chemical markers both for augmenting particle-based fire detection methods and for monitoring the post-fire cleanup phase in human spacecraft. These studies follow up on testing conducted in August 2010 and reported at ICES 2011. The tests were conducted at the NASA White Sands Test Facility in a custom glove box designed for burning fractional gram quantities of materials under varying heating profiles. The 623 L chamber was heavily instrumented to quantify organics (gas chromatography/mass spectrometry), inorganics by water extraction followed by ion chromatography, and select species by various individual commercially-available sensors. Evaluating new technologies for measuring carbon monoxide, hydrogen cyanide, hydrogen fluoride, hydrogen chloride and other species of interest was a key objective of the test. Some of these sensors were located inside the glovebox near the fire source to avoid losses through the sampling lines; the rest were located just outside the glovebox. Instruments for smoke particle characterization included a Tapered Element Oscillating Microbalance Personal Dust Monitor (TEOM PDM) and a TSI Dust Trak DRX to measure particle mass concentration, a TSI PTrak for number concentration and a thermal precipitator for collection of particles for microscopic analysis. Materials studied included Nomex®, M22759 wire insulation, granulated circuit board, polyvinyl chloride (PVC), Polytetrafluoroethylene (PTFE), Kapton®, and mixtures of PTFE and Kapton®. Furnace temperatures ranged from 340o to 640o C, focusing on the smoldering regime. Of particular interest in these tests was confirming burn repeatability and production of acid gases with different fuel mixture compositions, as well as the dependence of aerosol concentrations on temperature.

Smoke↗

Influence of Carboxymethyl Cellulose as a Thickening Agent for Glauber’s Salt-Based Low Temperature PCM

This work is focused on a novel, promising low temperature phase change material (PCM), based on the eutectic Glauber’s salt composition. To allow phase transition within the refrigeration range of temperatures of +5 °C to +12 °C, combined with a high repeatability of melting–freezing processes, and minimized subcooling, the application of three variants of sodium carboxymethyl cellulose (Na-CMC) with distinct molecular weights (700,000, 250,000, and 90,000) is considered. The primary objective is to optimize the stabilization of this eutectic PCM formulation, while maintaining the desired enthalpy level. Preparation methods are refined to ensure repeatability in mixing components, thereby optimizing performance and stability. Additionally, the influence of Na-CMC molecular weight on stabilization is examined through differential scanning calorimetry (DSC), T-history, and rheology tests. The PCM formulation of interest builds upon prior research in which borax, ammonium chloride, and potassium chloride were used as additives to sodium sulfate decahydrate (Glauber’s salt), prioritizing environmentally responsible materials. The results reveal that CMC with molecular weights of 250 kg/mol and 90 kg/mol effectively stabilize the PCM without phase separation issues, slowing crystallization kinetics. Conversely, CMC of 700 kg/mol proved ineffective due to the disruption of gel formation at its low gel point, hindering higher concentrations. Calculations of ionic concentration indicate higher Na ion content in PCM stabilized with 90 kg/mol CMC, suggesting increased ionic interactions and gel strength. A tradeoff is discovered between the faster crystallization in lower molecular weight CMC and the higher concentration required, which increases the amount of inert material that does not participate in the phase transition. After thermal cycling, the best formulation had a latent heat of 130 J/g with no supercooling, demonstrating excellent performance. This work advances PCM’s reliability as a thermal energy storage solution for diverse applications and highlights the complex relationship between Na-CMC molecular weight and PCM stabilization.

25 ENERGY STORAGE↗

The History of Allan Hills 84001 Revised: Multiple Shock Events

The geologic history of Martian meteorite Allan Hills (ALH) 84001 is more complex than previously recognized, with evidence for four or five crater-forming impacts onto Mars. This history of repeated deformation and shock metamorphism appears to weaken some arguments that have been offered for and against the hypothesis of ancient Martian life in ALH 84001. Allan Hills 84001 formed originally from basaltic magma. Its first impact event (I1) is inferred from the deformation (D1) that produced the granular-textured bands ("crush zones") that transect the original igneous fabric. Deformation D1 is characterized by intense shear and may represent excavation or rebound flow of rock beneath a large impact crater. An intense thermal metamorphism followed D1 and may be related to it. The next impact (I2) produced fractures, (Fr2) in which carbonate "pancakes" were deposited and produced feldspathic glass from some of the igneous feldspars and silica. After I2, carbonate pancakes and globules were deposited in Fr2 fractures and replaced feldspathic glass and possibly crystalline silicates. Next, feldspars, feldspathic glass, and possibly some carbonates were mobilized and melted in the third impact (I3). Microfaulting, intense fracturing, and shear are also associated with 13. In the fourth impact (I4), the rock was fractured and deformed without significant heating, which permitted remnant magnetization directions to vary across fracture surfaces. Finally, ALH 84001 was ejected from Mars in event I5, which could be identical to I4. This history of multiple impacts is consistent with the photogeology of the Martian highlands and may help resolve some apparent contradictions among recent results on ALH 84001. For example, the submicron rounded magnetite grains in the carbonate globules could be contemporaneous with carbonate deposition, whereas the elongate magnetite grains, epitaxial on carbonates, could be ascribed to vapor-phase deposition during I3.

Treiman, Allan H.↗

Materials Combustion Testing and Combustion Product Sensor Evaluations in FY12

NASA Centers continue to collaborate to characterize the chemical species and smoke particles generated by the combustion of current space-rated non-metallic materials including fluoropolymers. This paper describes the results of tests conducted February through September 2012 to identify optimal chemical markers both for augmenting particle-based fire detection methods and for monitoring the post-fire cleanup phase in human spacecraft. These studies follow up on testing conducted in August 2010 and reported at ICES 2011. The tests were conducted at the NASA White Sands Test Facility in a custom glove box designed for burning fractional gram quantities of materials under varying heating profiles. The 623 L chamber was heavily instrumented to quantify organics (gas chromatography/mass spectrometry), inorganics by water extraction followed by ion chromatography, and select species by various individual commercially-available sensors. Evaluating new technologies for measuring carbon monoxide, hydrogen cyanide, hydrogen fluoride, hydrogen chloride and other species of interest was a key objective of the test. Some of these sensors were located inside the glovebox near the fire source to avoid losses through the sampling lines; the rest were located just outside the glovebox. Instruments for smoke particle characterization included a Tapered Element Oscillating Microbalance Personal Dust Monitor (TEOM PDM) and a TSI Dust Trak DRX to measure particle mass concentration, a TSI PTrak for number concentration and a thermal precipitator for collection of particles for microscopic analysis. Materials studied included Nomex(R), M22759 wire insulation, granulated circuit board, polyvinyl chloride (PVC), Polytetrafluoroethylene (PTFE), Kapton(R), and mixtures of PTFE and Kapton(R). Furnace temperatures ranged from 340 to 640 C, focusing on the smoldering regime. Of particular interest in these tests was confirming burn repeatability and production of acid gases with different fuel mixture compositions, as well as the dependence of aerosol concentrations on temperature.

Combustion↗

Microscale Mechanical‐Chemical Modeling of Granular Salt: Insights for Creep

Abstract Microscale numerical modeling is potentially an effective approach for understanding salt creep, but it is quite challenging because natural salt grain boundaries can have complex and evolving geometry, and because contacts between these deformable salt mineral grains are dynamic as a result of compaction, chemical reaction, fluid flow, and heat transfer. In this study, we have overcome these challenges and developed a new microscale mechanical‐chemical (MC) model to analyze creep of salt at the microscale, accounting for coupled deformation, dynamic contacts, and chemical reaction in granular systems with realistic geometric representations. The MC model was realized by linking a new microscale mechanical code based on the numerical manifold method (NMM) to a reactive transport code named Crunch. We simulated the processes of reorganization of the salt grains, microfracturing, and pressure solution that contribute to creep at larger scales. Based on this first quantitative microscale model, we found that sharp corners of mineral grains can dominate the contact dynamics, microfracturing, and pressure solution when salt is compacted, thus governing the structural changes and porosity loss of the system. We found that pressure solution, which preferentially dissolves sharp corners and edges, can lead to relatively high porosity loss in the system, thus playing an important role in the creep of salt. Our analysis shows that the dynamic changes of salt granular systems involving grain relocation and pressure solution can occur repeatedly and continuously, thus contributing to longer‐term creep of salt at larger scales.

58 GEOSCIENCES↗

Mechanical Properties of Permanent Foaming Fixatives for Deactivation and Decommissioning Activities

DOE-EM have identified an operational requirement for a fixative that can immobilize and/or encapsulate residual contamination in 3D void volumes (pipes, gloveboxes, waste containers, etc.) during D and D activities. Failure to safely and effectively immobilize residual contamination can: Put workers at risk, Contaminate the public and environment, Drive up operational costs. Commercial-off-the-shelf (COTS) polyurethane (PU) foams is one possible solution and is currently being investigated in collaboration with Savannah River National Lab (SRNL). Mechanical property testing will dictate how well PU foams can withstand physical stressors outlined in safety documents while immobilizing residual contamination. Results can provide a performance criteria for Section 5 of ASTM E3191: Standard Specification for Permanent Foaming Fixatives Used to Mitigate Spread of Radioactive Contamination. Polyurethanes consists of repeating units of urethanes which are produced from an exothermic reaction between a polyol (an alcohol with two or more hydroxyl groups in a molecule) and an isocyanate [2]. PUs consists of 3D cells that are formed by a blowing agent which is normally water. Water interacting with the isocyanate creates carbon dioxide and urea which contributes to cells' growth and expansion. The cross-linking between the polyol and isocyanate solidify the cell faces and walls. Micro scale properties that can influence mechanical properties include: Relative density (ratio between density of cellular material and density of the solid of which the cell walls are made of). Cells connectivity between edges and faces, and number of cells contact neighbors [3]. Whether a foam is open-celled or closed-celled. Closed-celled foams have a thin membrane that encloses each cell which can contribute to the stiffness of the foam. Incorporating fillers in the PU matrix like carbon-based nanoparticles in the form of expandable graphite (EG) can increase the thermal and mechanical performance [4]. When exposed to heat, EG produces a char layer that prevents heat and oxygen transfer which is known as intumescing. Mechanical performance is dependent on amount of EG loading since the cell sizes are linearly dependent on it. Overall, the rigid foams (I-R2) proved superior. SEM Analysis: I-R2 had the most consistent spherical sizes (average cell diameter: 489 μm), which enhance the relative density the most [5]. Tensile Testing Results: I-R2 experienced the largest breaking load (103.65 lbf) and stress (289.42 psi). I-R2 also had a higher Young's Modulus compared to R1 (2.99 ksi to 2.09 ksi). Compression Testing Results: I-R2 had the highest stress at 80% deflection (360.67 psi), load (1387.48 lbf) and modulus (3.92 ksi)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Anatomy of Continuous Mars SEIS and Pressure Data from Unsupervised Learning

The seismic noise recorded by the Interior Exploration using Seismic Investigations, Geodesy, and Heat Transport (InSight) seismometer (Seismic Experiment for Interior Structure [SEIS]) has a strong daily quasi-periodicity and numerous transient microevents, associated mostly with an active Martian environment with wind bursts, pressure drops, in addition to thermally induced lander and instrument cracks. That noise is far from the Earth’s microseismic noise. Quantifying the importance of nonstochasticity and identifying these microevents is mandatory for improving continuous data quality and noise analysis techniques, including autocorrelation. Cataloging these events has so far been made with specific algorithms and operator’s visual inspection. We investigate here the continuous data with an unsupervised deep-learning approach built on a deep scattering network. This leads to the successful detection and clustering of these microevents as well as better determination of daily cycles associated with changes in the intensity and color of the background noise. We first provide a description of our approach, and then present the learned clusters followed by a study of their origin and associated physical phenomena. We show that the clustering is robust over several Martian days, showing distinct types of glitches that repeat at a rate of several tens per sol with stable time differences. We show that the clustering and detection efficiency for pressure drops and glitches is comparable to or better than manual or targeted detection techniques proposed to date, noticeably with an unsupervised approach. Finally, here we discuss the origin of other clusters found, especially glitch sequences with stable time offsets that might generate artifacts in autocorrelation analyses. We conclude with presenting the potential of unsupervised learning for long-term space mission operations, in particular, for geophysical and environmental observatories.

58 GEOSCIENCES↗

ADDITIVE MANUFACTURING AND REGULATORY TESTING OF CANISTERS FOR SPENT NUCLEAR FUEL MANAGEMENT

The back end of the fuel cycle focuses on the interim storage, transportation, and final disposition of the spent nuclear fuel from nuclear reactors. Commercial light water nuclear power stations across the United States operate with fuel assemblies being irradiated for up to 6 years (planned) in the reactor pressure vessel. After their planned irradiation, the fuel assemblies are moved to a spent fuel pool within the facility complex. After the spent nuclear fuel is removed from the fuel pool, it is typically inserted into a welded metal canister that can be transferred between overpacks for storage, transportation and possibly disposal. Most dry storage systems being used by industry today use dual purpose canisters (DPCs), designed for use in storage and transportation overpacks, but not specifically designed for disposal. Triple purpose-canisters, designed for disposal in addition to storage and transportation, have also been researched. Traditional manufacturing methods for spent fuel canisters involve fusion welding along the length or circumference of the canister which results in high tensile residual stresses in the joint weld zone (WZ) and heat affected zone (HAZ). In this paper, spent fuel canister designs were printed by wire arc additive manufacturing (AM) using the 316L SS welding wire to demonstrate: 1. Feasibility of spent nuclear fuel canister fabrication using this advanced manufacturing method, 2. Dynamic response of the additive manufacture canister design when subjected to the federally mandated Normal Conditions of Transport (NCT) and Hypothetical Accident Conditions (HAC) physical tests for Type B packages. This paper will focus on the canister printing design and structural tests. The AM 3D printed design, regulatory testing, and post-test evaluation of the canister tested to the 10 CFR 71.71 and 10 CFR 71.73 requirements will be presented. One AM canister design was subjected to the penetration, free drop, and puncture test. Before and after the dynamic structural tests, the AM canister design was scanned with a handheld scanner to capture a 3D CAD geometry to compare to the 3D printed canister design in the deformed shape. The scanned geometry was sectioned in areas with deformation and the cross-section profile was measured to determine accurate and repeated results of the deformed shape of the AM canister design.

Martinez, Oscar↗