Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAUGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Gauge invariance, current conservation, and GIAO's

The well known relationship between gauge invariance and current conservation is exhibited within the usual quantum mechanical formalism. It is then shown that the use of gauge-invariant atomic orbitals (GIAO) does not necessarily lead to the expected current conservation. The reason is found to lie in the constrained nature of the gauge invariance which is provided by the use of GIAO's. It is concluded that this invariance is, of itself, no argument in favor of their use.

Epstein, S. T.↗

Gauge calibration by diffusion

Vacuum gage calibration by diffusing a known quantity of gas through a heated barrier into a gauge is examined. The gas flow raises the pressure in the gauge to known level and is then compared with the gauge's pressure reading.

Brock, F. J.↗

An improved thin-film gauge for shock-tube thermal studies.

An improved type of thin-film heat gauge has been developed and used to measure heat-transfer rates from a shock-heated plasma to the end wall of a shock tube. The gauge is a resistance thermometer consisting of a triple-layered sensor coated by a moderately thick film of SiO2. It was used to measure heat transfer from nonionized argon at temperatures of up to 16000 K. A marked increase in heat transfer at the onset of ionization near the wall indicates that the gauge can be used to obtain the contribution of free electrons to the thermal transport.

Willeke, K.↗

Gauge invariance, current conservation, and GIAO's.

The well-known relationship between gauge invariance and current conservation is exhibited within the usual quantum mechanical formalism. It is then shown that the use of Gauge Invariant Atomic Orbitals does not necessarily lead to the expected current conservation. The reason is found to lie in the constrained nature of the gauge invariance which is provided by the use of GIAO's. It is concluded that this invariance is, of itself, no argument in favor of their use.

Epstein, S. T.↗

Graphite ionization vacuum gauge

Triode gauge with electron source, electron collector, and positive ion collector made from either graphite or carbon material extends low-pressure ranges of existing gauges by changing only materials used in construction. Advantages of graphite gauge stem from physical properties of graphite (or carbon).

Beitel, G. A.↗

Design, development and manufacture of a breadboard radio frequency mass gauging system

The feasibility of the RF gauging mode, counting technique was demonstrated for gauging liquid hydrogen and liquid oxygen under all attitude conditions. With LH2, it was also demonstrated under dynamic fluid conditions, in which the fluid assumes ever changing positions within the tank, that the RF gauging technique on the average provides a very good indication of mass. It is significant that the distribution of the mode count data at each fill level during dynamic LH2 and LOX orientation testing does approach a statistical normal distribution. Multiple space-diversity probes provide better coupling to the resonant modes than utilization of a single probe element. The variable sweep rate generator technique provides a more uniform mode versus time distribution for processing.

Source record↗

Modified gauge for time-resolved skin-friction measurements

A new gauge for skin-friction measurements in turbulent flows involving a wire close to the surface and a second, flush-mounted film which serves as a constant temperature guard heater is described and evaluated. It is shown that a laminar calibration of the gauge applies to measurements in turbulent flow and that the frequency response of the gauge is appropriate for time-resolved data in such a flow. Initial results from a turbulent channel flow are presented.

Ajagu, C. O.↗

A simple example of a classical gauge transformation

Attention is given to the manner in which the interaction of a gravitational field with a diffusing gas is induced by a gauge transformation. Since the gas can be thought of as a field, the diffusion process may be represented by a Lagrangian density with the symmetry property of invariance under translation. While this property is lost when the field interacts with a static gravitational field, it is formally restored when an appropriate gauge transformation is performed. This ascription of field properties to a gas offers an illuminating illustration of the coupling of matter to a gauge field within the context of classical mechanics.

Whitten, R. C.↗

High temperature thermocouple and heat flux gauge using a unique thin film-hardware hot juncture

A special thin film-hardware material thermocouple (TC) and heat flux gauge concept for a reasonably high temperature and high flux flat plate heat transfer experiment was fabricated and tested to gauge temperatures of 911 K. This concept was developed for minimal disturbance of boundary layer temperature and flow over the plates and minimal disturbance of heat flux through the plates. Comparison of special heat flux gauge Stanton number output at steady-state conditions with benchmark literature data was good and agreement was within a calculated uncertainty of the measurement system. Also, good agreement of special TC and standard TC outputs was obtained and the results are encouraging. Oxidation of thin film thermoelements was a primary failure mode after about 5 of operation.

Liebert, C. H.↗

High-temperature thermocouple and heat flux gauge using a unique thin film-hardware hot junction

A special thin film-hardware material thermocouple (TC) and heat flux gauge concept for a reasonably high temperature and high flux flat plate heat transfer experiment was fabricated and tested to gauge temperatures of 911 K. This concept was developed for minimal disturbance of boundary layer temperature and flow over the plates and minimal disturbance of heat flux through the plates. Comparison of special heat flux gauge Stanton number output at steady-state conditions with benchmark literature data was good and agreement was within a calculated uncertainty of the measurement system. Also, good agreement of special TC and standard TC outputs was obtained and the results are encouraging. Oxidation of thin film thermoelements was a primary failure mode after about 5 of operation.

Liebert, C. H.↗

Origin of gauge invariance in string theory

A first quantization of the space-time embedding Chi exp mu and the world-sheet metric rho of the open bosonic string. The world-sheet metric rho decouples from S-matrix elements in 26 dimensions. This formulation of the theory naturally includes 26-dimensional gauge transformations. The gauge invariance of S-matrix elements is a direct consequence of the decoupling of rho. Second quantization leads to a string field Phi(Chi exp mu, rho) with a gauge-covariant equation of motion.

Horowitz, G. T.↗

Bonding Gauges To Carbon/Carbon Composites

Thermal-expansion properties modified to prevent bonds from failing. Proposed transition layer deposited between substrate and strain or temperature gauge to be bonded to substrate. Intended particularly for gauges that must operate at temperatures above 600 degrees F (320 degrees C) and substrates like fiber-reinforced carbon/carbon composites. Reduces stress caused by difference between thermal expansions of gauge and substrate materials. Without transition layer, stress often weakens or breaks bond.

Lemcoe, M. M.↗

Gauged Q-balls

Classical non-topological soliton configurations are considered within the theory of a complex scalar field with a gauged U symmetry. Their existence and stability against dispersion are demonstrated and some of their properties are investigated analytically and numerically. The soliton configuration is such that inside the soliton the local U symmetry is broken, the gauge field becomes massive and for a range of values of the coupling constants the soliton becomes a superconductor pushing the charge to the surface. Furthermore, because of the repulsive Coulomb force, there is a maximum size for these objects, making impossible the existence of Q-matter in bulk form. Also briefly discussed are solitons with fermions in a U gauge theory.

Lee, Kimyeong↗

More About High-Temperature Resistance Strain Gauges

Two reports present additional information on electrical-resistance strain gauges described in "High-Temperature Resistance Strain Gauges" (LEW-15379). For protection against oxidation at high temperatures, gauges covered, by flame spraying, with coats of alumina containing up to 1 weight percent of yttria or, perferably, containing 4 to 6 weight percent of zirconia.

Englund, D. R.↗

Rain rate duration statistics derived from the Mid-Atlantic coast rain gauge network

A rain gauge network comprised of 10 tipping bucket rain gauges located in the Mid-Atlantic coast of the United States has been in continuous operation since June 1, 1986. Rain rate distributions and estimated slant path fade distributions at 20 GHz and 30 GHz covering the first five year period were derived from the gauge network measurements, and these results were described by Goldhirsh. In this effort, rain rate time duration statistics are presented. The rain duration statistics are of interest for better understanding the physical nature of precipitation and to present a data base which may be used by modelers to convert to slant path fade duration statistics. Such statistics are important for better assessing optimal coding procedures over defined bandwidths.

Goldhirsh, Julius↗

Application of the Modular Automated Reconfigurable Assembly System (MARAS) concept to adaptable vision gauging and parts feeding

This paper presents the first phase results of a collaborative effort between university researchers and a flexible assembly systems integrator to implement a comprehensive modular approach to flexible assembly automation. This approach, named MARAS (Modular Automated Reconfigurable Assembly System), has been structured to support multiple levels of modularity in terms of both physical components and system control functions. The initial focus of the MARAS development has been on parts gauging and feeding operations for cylinder lock assembly. This phase is nearing completion and has resulted in the development of a highly configurable system for vision gauging functions on a wide range of small components (2 mm to 100 mm in size). The reconfigurable concepts implemented in this adaptive Vision Gauging Module (VGM) are now being extended to applicable aspects of the singulating, selecting, and orienting functions required for the flexible feeding of similar mechanical components and assemblies.

By, Andre Bernard↗

Can salt on an optical rain gauge lens affect performance?

The optical rain gauge (ORG) by ScTI is designed to be tolerant to reduction of infrared beam intensity due to a dirty lens. Recently there is interest in long term use of optical gauges onboard buoys at sea. Because of logistics, these systems are serviced infrequently, i.e., every several months. Due to the proximity of the gauges to the sea surface, salt can be expected to be deposited on the lens. To obtain an indication of the potential for dirty lens to affect the ORG calibration, two simple experiments were conducted. In the control experiment, a sample ORG was compared to three other ORG's during natural rain events. Next a translucent mask was placed on the transmitter lens of the sample ORG and again data were collected under natural rain conditions. The mask reduced the gain of the perturbed ORG by about 30%. The perturbed ORG operated rather well in that the mask only causes a change in the gain and does not cause data drop out at low rain rates. However, the reduced gain would seriously impact an assessment of rain statistics.

Bliven, Larry F.↗

Rain gauge calibration and testing

Prior to the Tropical Oceans Global Atmosphere-Coupled Ocean Atmosphere Response Experiment (TOGA-COARE), 42 Model 100 series optical gauges were tested in the rain simulator facility at Wallops Island before shipment to the field. Baseline measurements at several rain rates were made simultaneously with collector cans, tipping bucket, and a precision weighing gauge and held for post-COARE evaluation with a repeat set of measurements that were to be recorded after the instruments were returned. This was done as a means of detecting any calibration changes that might have occurred while deployed. Although it was known that the artificial rain in the simulator did not contain the required exponential distribution for accurate optical rain gauge rate measurements, use of the facility was necessary because it was the only means available for taking controlled observations with instruments that were received, tested, and shipped out in groups over a period of months. At that point, it was believed that these measurements would be adequately precise for detecting performance changes over time. However, analysis of the data by STI now indicates that this may not be true. Further study of the data will be undertaken to resolve this.

Wilkerson, John↗