Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Pipe Overpack Container Fire Testing: Phase II-B

The Pipe Overpack Container (POC) was developed at Rocky Flats to transport plutonium residues with higher levels of plutonium than standard transuranic (TRU) waste to the Waste Isolation Pilot Plant (WIPP) for disposal. In 1996 Sandia National Laboratories (SNL) conducted a series of tests to determine the degree of protection POCs provided during storage accident events. One of these tests exposed four of the POCs to a 30-minute engulfing pool fire. This test resulted in one of the POCs generating sufficient internal pressure to pop off its drum lid and expose the top of the pipe container (PC) to the fire environment. The initial contents of the POCs were inert materials that would not generate large internal pressure within the PC if heated. However, POCs are now being used to store combustible Transuranic (TRU) waste at Department of Energy (DOE) sites. At the request of DOE's Office of Environmental Management (EM) and National Nuclear Security Administration (NNSA), SNL started conducting a new series of fire tests in 2015 to examine whether PCs with combustibles would reach a temperature that could result in: (1) decomposition of inner contents and (2) subsequent generation of sufficient gas to cause the PC to over-pressurize and release its inner contents. In 2016, Phase II of the tests showed that POCs tested in a pool fire failed within 3 minutes of ignition with the POC lid ejecting. These POC lids were fitted with a NUCFIL-019DS filter and revealed that this specific filter did not relieve sufficient pressure to prevent lid ejection. In the Fall of 2017, Phase II-A was conducted to expose POCs to a 30-minute pool fire with similar configurations to those tested in Phase II, except that the POC lids were fitted with an UltraTech (UT) 9424S filter instead. That specific filter was chosen because of its design to help relieve internal pressure during the fire and thus prevent lid ejection. In Phase II-A, however, setups of two POCs stacked upon one another were never tested, which led to this phase of tests, Phase II-B. This report will describe the various tests conducted in Phase II-B, present results from these tests, and implications for the POCs based on the test results will be discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of a Nitrogen and Magnesium Oxide based Class A, B & D Suffocating Fire System (SFSS) for Gloveboxes

Testing related to the development and performance of a “Proof of Concept” Nitrogen/Magnesium Oxide Suffocating Fire System (SFSS) was conducted at Fire and Pump Service Group (FPSG) located in Rancho Dominguez, California. The SFSS Engineering Team (SFSSET), consisting of FPSG and Los Alamos National Laboratory (LANL) personnel researched, developed a prototype, and conducted testing to determine effective means to deliver magnesium oxide (MgO) sand into a glovebox (GB) in a class D fire event. The prototypes development also established the effective coverage area of a magnesium oxide suppression system as well as demonstrated that the GB inert atmosphere could be maintained during and after the release of the MgO sand to control Class A, B and D fires. Previous testing conducted on nitrogen based SFSS provided evidence that the nitrogen based SFSS controlled Class A and B fires (Ralph Clayton, Los Alamos National Laboratory, Brandon Troc and Frank Broidy, Fire and Pump Service Group 2020).Final testing was conducted within a mock GB capable of simulating an inert glovebox atmosphere. Testing demonstrated that the inert atmosphere can be maintained during and after discharge of the MgO sand over a coverage area.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Test and Validate Distributed Coaxial Cable Sensors for in situ Condition Monitoring of Coal-Fired Boiler Tubes

This project aims to test, validate, and advance the technology readiness level (from TRL5 to TRL7) of a novel low-cost distributed stainless-steel/ceramic coaxial cable sensing (SSC-CCS) technology for in situ monitoring of the boiler tube temperature in existing coal-fired power plants. The novel SSC-CCS sensing technology and associated condition-based monitoring (CBM) software to be demonstrated in this project will lead to an improved understanding of the boiler tube failure mechanisms and a prognostic system to improve the overall performance, reliability, and flexibility of the nation’s coal-fired power plant fleet. A boiler tube monitoring system with distributed coaxial cable temperature sensors and a sensor acquisition system was constructed. The high-temperature coaxial cable sensor with a length of 1.3m was made by using a quartz tube (1mm inner diameter (ID) and 6mm outer diameter (OD)) to concentrically separate a 304 stainless-steel (SS) rod (1mm OD) and SS tube (7.94mm OD and 6.16mm ID). The sensor acquisition system includes a vector network analyzer (VNA), a radio frequency (RF) power amplifier, multiple switches and a USB hub. The distributed stainless-steel quartz coaxial cable sensor (SSQ-CCS) had a linear response to temperature with a resolution uncertainty of σ = 0.77℃. To withstand the harsh conditions of 3,300 steam pressures and 800℃ high temperatures, the sensor was shielded by a protective tube made of the same material as the boiler tube. The protection tube had an OD of 1.5 inches and a thickness of 0.25 inches. In the laboratory tests, the sensor showed good sensitivity and fast response. The drift was bounded between +0.33% and -0.67% during a test at 600℃ for 350 hours, indicating good stability of the sensor. A field test was conducted where four sensors were welded on four superheat tubes (SH-Ts) at a coal-fired power station over 400 days. Conventional thermocouples were welded to the superheater tubes alongside the coaxial cable sensors for the purpose of comparison. Two sensors were capable of distributed sensing, with three multiplexed sensing sections. The other two sensors were single section. During the 400-day test period, the power plant experienced startups and shutdowns. At the steady state operations, the temperature of the boiler tube is about 600℃ (1112°F). The sensors recorded the entire coal-firing processes (start-up, steady state, and shut-down) and the glitch event. A GSM modem and a Watchdog were added to the system to ensure reliable data recording. The GSM modem sent daily messages to plant managers and Clemson team to inform the status of the sensor system. If the system was not normally working, the Watchdog would reboot the system automatically. The new coaxial cable based distributed sensing technology has been proven to be successful in both laboratory and field tests. A comprehensive four-stage multi-physics computational framework has been developed to assist the design, optimization, installation, and operation of SSQ-CCS. With the consideration of various operation conditions, we predict the distributions of flue gas temperatures within coal-fired boilers, the temperature correlation between the boiler tube and SSQ-CCS, and the safety of SSQ-CCS. A conditional-based monitoring system is implemented as well. The computational framework developed in this work can guide the future operation of coal-fired plants and other power plants for the safety prediction of boiler operations.

01 COAL, LIGNITE, AND PEAT↗

Dissection of Carbon and Nitrogen Cycling in Post-Fire Soil Environments using a Genome- Informed Experimental Community (Final Technical Report)

Wildfires are a natural part of many forest ecosystems, with globally important carbon (C) storage and nutrient cycling consequences, and they are increasing in frequency and severity in Western North America. Forest fires affect soil C stocks in complex ways; some C is released into the atmosphere through combustion, while a large percentage of the C is added to the soil in the form of pyrogenic organic matter. Worldwide, it is estimated that 16% of soil organic matter is pyrogenic, while locally, this number may be as high as 80%. Understanding how wildfires affect soil organic matter cycling requires understanding how microbes respond to pyrogenic organic matter and other post-fire soil conditions. However, our understanding of microbial interactions within post-fire soil was in its infancy at the time of our proposal. Outstanding questions included: Which microbes are capable of degrading pyrogenic organic matter? What are the relevant genes and metabolites associated with this degradation? What are the key interactions among post-fire microbes? Key highlights of outcomes supported by this grant included training eleven early-career scientists and two early-career PIs, publication of twelve peer-reviewed papers, cross-lab collaborations that empowered complex scientific approaches, the development of an open-source automated gas sampler to drive novel insights in C cycling, enhanced understanding of post-fire microbial community dynamics, and novel genetic and molecular insights into microbial responses to fire.

54 ENVIRONMENTAL SCIENCES↗

Hanford Site Post-Fire Vegetation Monitoring Report for Calendar Year 2022

The Hanford Site is comprised of an expanse of shrub-steppe habitats that provide exceptional value to plants and animals located on the Site and in the surrounding greater Columbia Basin. The greatest threat to this habitat is fire-related conversion to a cheatgrass-dominated monoculture. In order to decrease future fire risk and to disrupt the positive feedback cycle between cheatgrass and fire, land managers can make efforts to restore native vegetation following a fire. The goal of this report is to analyze vegetation recovery post-fire in both restored and unrestored areas to inform future post-fire response actions.

54 ENVIRONMENTAL SCIENCES↗

Hanford Site Post-Fire Vegetation Monitoring Report for Calendar Year 2021

The Hanford Site presents an expanse of shrub-steppe habitat that provides exceptional value to plants and animals located on the Site and in the surrounding greater Columbia Basin. The greatest threat to this habitat is fire-related conversion to a cheatgrass-dominated monoculture. In order to decrease future fire risk and to disrupt the positive feedback cycle between cheatgrass and fire, land managers can make efforts to restore native vegetation following a fire. The goal of this report is to analyze vegetation recovery post-fire in both restored and unrestored areas to inform future post-fire response actions.

54 ENVIRONMENTAL SCIENCES↗

Eucalyptus Are Unlikely to Escape Plantations and Invade Surrounding Forests Managed with Prescribed Fire in Southeastern US

Woody biomass production can increase through establishment of non-native tree species exhibiting greater growth potential than traditional native species. Interest in growing Eucalyptus in the southeastern US has raised concern over its potential spread and invasion, which could impact ecosystem properties and functions. Within the matrix of land use where Eucalyptus establishment is being considered in the southeastern US, surrounding pine forests managed with fire represent a likely pathway for invasion. We used greenhouse and field experiments to evaluate the potential invasion risk of Eucalyptus benthamii. We were specifically interested in determining if seeds could successfully germinate in fire-maintained pine forests and if fire-return intervals influenced germination through impacts on litter accumulation and light availability. The greenhouse experiment investigated the influence of light availability on germination success, whereas the field study investigated the influence of time since fire, and thus litter accumulation and light availability, on germination success. Percent germination was similar under non-shaded controls and moderate shade, but complete shade resulted in low germination rates. Germination was lower in the field compared to the greenhouse and was influenced by litter and light availability, which varied according to fire-return intervals. Litter increased, and light availability decreased, with time since burn. Germination was negatively related to litter depth and positively related to light availability, thereby decreasing with time since fire. Germination increased with litter removal but remained positively related to light availability after litter removal. Higher germination with litter removal suggests germination is influenced by litter, but higher germination with increased light availability, regardless of raking, suggests germination is also influenced by light availability. Despite these relationships, no seedlings persisted through the growing season. The low germination rates under a variety of field conditions coupled with the lack of persistence suggests establishment may be unlikely, regardless of the surrounding land matrix.

54 ENVIRONMENTAL SCIENCES↗

Radiative effects of interannually varying vs. interannually invariant aerosol emissions from fires

Abstract. Open-burning fires play an important role in the earth's climate system. In addition to contributing a substantial fraction of global emissions of carbon dioxide, they are a major source of atmospheric aerosols containing organic carbon, black carbon, and sulfate. These “fire aerosols” can influence the climate via direct and indirect radiative effects. In this study, we investigate these radiative effects and the hydrological fast response using the Community Atmosphere Model version 5 (CAM5). Emissions of fire aerosols exert a global mean net radiative effect of −1.0 W m−2, dominated by the cloud shortwave response to organic carbon aerosol. The net radiative effect is particularly strong over boreal regions. Conventionally, many climate modelling studies have used an interannually invariant monthly climatology of emissions of fire aerosols. However, by comparing simulations using interannually varying emissions vs. interannually invariant emissions, we find that ignoring the interannual variability of the emissions can lead to systematic overestimation of the strength of the net radiative effect of the fire aerosols. Globally, the overestimation is +23 % (−0.2 W m−2). Regionally, the overestimation can be substantially larger. For example, over Australia and New Zealand the overestimation is +58 % (−1.2 W m−2), while over Boreal Asia the overestimation is +43 % (−1.9 W m−2). The systematic overestimation of the net radiative effect of the fire aerosols is likely due to the non-linear influence of aerosols on clouds. However, ignoring interannual variability in the emissions does not appear to significantly impact the hydrological fast response. In order to improve understanding of the climate system, we need to take into account the interannual variability of aerosol emissions.

54 ENVIRONMENTAL SCIENCES↗

Investigation of short-term effective radiative forcing of fire aerosols over North America using nudged hindcast ensembles

Aerosols from fire emissions can potentially have large impact on clouds and radiation. However, fire aerosol sources are often intermittent, and their effect on weather and climate is difficult to quantify. Here we investigated the short-term effective radiative forcing of fire aerosols using the global aerosol–climate model Community Atmosphere Model version 5 (CAM5). Different from previous studies, we used nudged hindcast ensembles to quantify the forcing uncertainty due to the chaotic response to small perturbations in the atmosphere state. Daily mean emissions from three fire inventories were used to consider the uncertainty in emission strength and injection heights. The simulated aerosol optical depth (AOD) and mass concentrations were evaluated against in situ measurements and reanalysis data. Overall, the results show the model has reasonably good predicting skills. Short (10-day) nudged ensemble simulations were then performed with and without fire emissions to estimate the effective radiative forcing. Results show fire aerosols have large effects on both liquid and ice clouds over the two selected regions in April 2009. Ensemble mean results show strong negative shortwave cloud radiative effect (SCRE) over almost the entirety of southern Mexico, with a 10-day regional mean value of −3.0 W m −2 . Over the central US, the SCRE is positive in the north but negative in the south, and the regional mean SCRE is small (−0.56 W m −2 ). For the 10-day average, we found a large ensemble spread of regional mean shortwave cloud radiative effect over southern Mexico (15.6 % of the corresponding ensemble mean) and the central US (64.3 %), despite the regional mean AOD time series being almost indistinguishable during the 10-day period. Moreover, the ensemble spread is much larger when using daily averages instead of 10-day averages. This demonstrates the importance of using a large ensemble of simulations to estimate the short-term aerosol effective radiative forcing.

54 ENVIRONMENTAL SCIENCES↗

Aircraft Engine Sump Fire Mitigation

An investigation was performed of the conditions in which fires can result and be controlled within the bearing sump simulating that of a gas turbine engine; Esso 4040 Turbo Oil, Mobil Jet 2, and Monsanto MCS-2931 lubricants were used. Control variables include the oil inlet temperature, bearing temperature, oil inlet and scavenge rates, hot air inlet temperature and flow rate, and internal sump baffling. In addition to attempting spontaneous combustion, an electric spark and a rub (friction) mechanism were employed to ignite fires. Spontaneous combustion was not obtained; however, fires were readily ignited with the electric spark while using each of the three test lubricants. Fires were also ignited using the rub mechanism with the only test lubricant evaluated, Esso 4040. Major parameters controlling ignitions were: Sump configuration; Bearing and oil temperatures, hot air temperature and flow and bearing speed. Rubbing between stationary parts and rotating parts (eg. labyrinth seal and mating rub strip) is a very potent fire source suggesting that observed accidental fires in gas turbine sumps may well arise from this cause.

Rosenlieb, J. W.↗

Mapping a recent forest fire with ERTS-1 MSS data

Accurate fire boundary delineation provides essential information to forest managers in allocating suppression costs and planning regeneration efforts. The objective of this study was to test the capability of computer-aided analysis of ERTS-1 MSS data to accurately define the boundary of a recent forest fire and to discriminate spectral classes within the perimeter. Two frames of ERTS-1 MSS data were selected for analysis of the Moccasin Mesa Fire in Mesa Verde National Park. Data sets were collected one-half growing season and one full growing season after the fire. Results indicate that computer-aided analysis of ERTS-1 MSS data has the capability for accurately delineating fire boundaries and determining acreage of the burned area. Distinct spectral classes may also be defined within the fire perimeter.

Hitchcock, H. C.↗

Fire dynamics of modern aircraft from a materials point of view

A general approach for selecting polymers to increase fire safety in aircraft is described. It is shown that polymer flammability and thermal protection capability are related to the molecular structure of the polymer and its thermochemical properties. These criteria are used to develop advanced fire-resistant materials which can achieve increased survivability in both post-crash and in-flight fires. The degree of fire hardening of materials depends greatly on the available heat load and fire threat present. It is shown that improvements in fire safety can be achieved by the use of polymers possessing certain basic thermochemical parameters such as high char yield.

Parker, J. A.↗

An analysis of aircraft accidents involving fires

All U. S. Air Carrier accidents between 1963 and 1974 were studied to assess the extent of total personnel and aircraft damage which occurred in accidents and in accidents involving fire. Published accident reports and NTSB investigators' factual backup files were the primary sources of data. Although it was frequently not possible to assess the relative extent of fire-caused damage versus impact damage using the available data, the study established upper and lower bounds for deaths and damage due specifically to fire. In 12 years there were 122 accidents which involved airframe fires. Eighty-seven percent of the fires occurred after impact, and fuel leakage from ruptured tanks or severed lines was the most frequently cited cause. A cost analysis was performed for 300 serious accidents, including 92 serious accidents which involved fire. Personal injury costs were outside the scope of the cost analysis, but data on personnel injury judgements as well as settlements received from the CAB are included for reference.

Lucha, G. V.↗

Fire dynamics of modern aircraft from a materials point of view

A general approach for selecting polymers to increase fire safety in aircraft is described. It is shown that polymer flammability and thermal protection capability are related to the molecular structure of the polymer and its thermochemical properties. These criteria are used to develop advanced fire-resistant materials that can achieve increased survivability in both post-crash and in-flight fires. The degree of fire hardening of materials depends greatly on the available heat load and fire threat present. It is shown that improvements in fire safety can be achieved by the use of polymers possessing certain basic thermochemical parameters such as high char yield.

Parker, J. A.↗

Fire safety evaluation of aircraft lavatory and cargo compartments

A program of experimental fires has been carried out to assess fire containment and other fire hazards in lavatory and cargo compartments of wide-body jet aircraft by evaluation of ignition time, burn-through time, fire spread rate, smoke density, evolution of selected combustible and toxic gases, heat flux, and detector response. Two tests were conducted: one involving a standard Boeing 747 lavatory and one involving a simulated DC-10 cargo compartment. A production lavatory module was furnished with conventional materials and was installed in an enclosure. The ignition load was four polyethylene bags containing paper and plastic waste materials representive of a maximum flight cabin waste load. Standard aircraft ventilation conditions were utilized and the lavatory door was closed during the test. Lavatory wall and ceiling panels contained the fire spread during the 30-minute test. Smoke was driven into the enclosure primarily through the ventilation grille in the door and through the gaps between the bifold door and the jamb where the door distorted from the heat earlier in the test. The interior of the lavatory was almost completely destroyed by the fire.

Kourtides, D. A.↗

Flash fire propensity of materials

Flash fire test results on 86 materials, evaluated using the USF flash fire screening test, are presented. The materials which appear least prone to flash fires are PVC, polyphenylene oxide and sulfide, and polyether and polyaryl sulfone; these did not produce flash fires under these particular test conditions. The principal value of these screening tests at the present time is in identifying materials which appear prone to flash fires, and in identifying which formulations of a generic material are more or less prone to flash fires.

Hilado, C. J.↗

US Coast Guard lightweight fire-fighting module

The U.S. Coast Guard Fire-fighting Module developed for the purpose of fighting fires in harbors and on ships is described. The module can be lifted by a dockside crane or helicopter and placed on the deck of a patrol boat or cutter for transportation to the scene of the fire. At the fire the module can be set up and put in operation by a crew of two in approximately fifteen minutes. Once in operation the module will deliver water to two fire nozzles at a pressure of 150 psi and a flow rate of 2000 gpm. Sufficient fuel is carried in the module for three hours of continuous operation. A record of the development of the fire fighting module is also presented.

Source record↗

IGCC performance comparison for variations in gasifier type and gas turbine firing temperature

Performance estimates were made for a series of integrated coal gasification combined cycle (IGCC) power systems using three generic types of coal gasification subsystems. The objectives of this study were (1) to provide a self consistent comparison of IGCC systems using different types of gasifiers and different oxidants and (2) to use this framework of cases to evaluate the effect of a gas turbine firing temperature and cooling approach an overall system efficiency. The basic IGCC systems considered included both air and oxygen blown versions of a fluidized bed gasifier, represented by the Westinghouse design, and an entrained bed gasifier, represented by the Texaco design. Also considered were systems using an oxygen blown, fixed bed gasifier, represented by the British Gas Corporation (BGC) slagging gasifier. All of these gasifiers were integrated with a combined cycle using a gas turbine firing temperature of 1700 K (2600 F) and a compressor pressure ratio of 16:1. Steam turbine throttle conditions were chosen to be 16.6 MPa/811 K (2400 psia/1000 F) with a single reheat to 810 K (1000 F). Some of these cases were modified to allow the evaluation of the effect of gas turbine firing temperature. Turbine firing temperatures from state of the art 1365 K (2000 F) to an advanced technology 1920 K (3000 F) were analyzed. A turbine cooling technology that maintains metal temperatures below acceptable limits was assumed for each level of firing temperature. System performance comparisons were made using three advanced turbine cooling technologies for the 1920 K (3000 F) firing temperature. The results indicate that the IGCC using the BGC gasifier had the highest net system efficiency (42.1 percent) of the five gasification cases considered.

Stochl, R. J.↗