Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fatigue testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Research on Graphite Reinforced Glass Matrix Composites

This report contains the results obtained in the first twelve months of research under NASA Langley Contract NAS1-14346 for the origination of graphite-fiber reinforced glass matrix composites. Included in the report is a summary of the research by other investigators in this area. The method selected to form the composites consisted of pulling the graphite fiber through a slurry containing powdered glass, winding up the graphite fiber and the glass it picks up on a drum, drying, cutting into segments, loading the tape segment into a graphite die, and hot pressing. During the course of the work, composites were made with a variety of graphite fibers in a C.G.W. 7740 (Pyrex) glass matrix. The graphite fibers used included Hercules HMS, Hercules HTS, Thornel 300S, and Celanese DG-102 and, of these, the Hercules HMS and Celanese DG-102 graphite fibers in C.G.W. 7740 gave the most interesting but widely different results. Hercules HMS fiber in C.G.W. 7740 glass (Pyrex) showed an average four-point flexural strength of 848 MPa or 127,300 psi. As the test temperature was raised from room temperature to 560 C in argon or vacuum, the strength was higher by 50 percent. However, in air, similar tests at 560 C gave a severe loss in strength. These composites also have good thermal cycle properties in argon or vacuum, greatly increased toughness compared to glass, and no loss in strength in a 100 cycle fatigue test. Celanese DG-102 fiber in C.G.W. 7740 glass (Pyrex) had a much lower flexural strength but did not suffer any loss in this strength when samples were heated to 560 C in air for 4 hrs.

Bacon, J. F.↗

Small Crack Growth and Fatigue Life Predictions for High-Strength Aluminium Alloys: Experimental and Fracture Mechanics Analysis - Part 1

The small crack effect was investigated in two high-strength aluminium alloys: 7075-T6 bare and LC9cs clad alloy. Both experimental and analytical investigations were conducted to study crack initiation and growth of small cracks. In the experimental program, fatigue tests, small crack and large crack tests A,ere conducted under constant amplitude and Mini-TWIST spectrum loading conditions. A pronounced small crack effect was observed in both materials, especially for the negative stress ratios. For all loading conditions, most of the fatigue life of the SENT specimens was shown to be crack propagation from initial material defects or from the cladding layer. In the analysis program, three-dimensional finite element and A weight function methods were used to determine stress intensity factors and to develop SIF equations for surface and corner cracks at the notch in the SENT specimens. A plastisity-induced crack-closure model was used to correlate small and large crack data, and to make fatigue life predictions, Predicted crack-growth rates and fatigue lives agreed well with experiments. A total fatigue life prediction method for the aluminum alloys was developed and demonstrated using the crack-closure model.

Wu, X. R.↗

Evaluation of CBS 600 carburized steel as a gear material

Gear endurance tests were conducted with one lot of consumable-electrode vacuum-melted (CVM) AISI 9310 gears and one lot of air-melt CBS 600 gears. The gears were 8 pitch with a pitch diameter of 8.89 centimeters (3.5 in.). Bench-type rolling-element fatigue tests were also conducted with one lot of CVM AISI 9310, three lots of CVM CBS 600, and one of air-melt CBS 600 material. The rolling-element bars were 0.952 centimeter (0.375 in.) in diameter. The CBS 600 material exhibited pitting fatigue lives in both rolling-element specimens and gears at least equivalent to that of CVM AISI 9310. Tooth fracture failure occurred with the CBS 600 gears after overrunning a fatigue spall, but it did not occur with the CVM AISI 9310 gears. Tooth fracture in the CBS 600 was attributed to excessive carbon content in the case, excessive case depth, and a higher than normal core hardness.

Townsend, D. P.↗

Threshold Assessment of Gear Diagnostic Tools on Flight and Test Rig Data

A method for defining thresholds for vibration-based algorithms that provides the minimum number of false alarms while maintaining sensitivity to gear damage was developed. This analysis focused on two vibration based gear damage detection algorithms, FM4 and MSA. This method was developed using vibration data collected during surface fatigue tests performed in a spur gearbox rig. The thresholds were defined based on damage progression during tests with damage. The thresholds false alarm rates were then evaluated on spur gear tests without damage. Next, the same thresholds were applied to flight data from an OH-58 helicopter transmission. Results showed that thresholds defined in test rigs can be used to define thresholds in flight to correctly classify the transmission operation as normal.

Dempsey, Paula J.↗

In situ indentation and high cycle tapping deformation responses in a nanolaminate crystalline/amorphous metal composite

The incorporation of nanostructured and amorphous metals into modern applications is reliant on the understanding of deformation and failure modes in constrained conditions. To study this, a 105 nm crystalline Cu/160 nm amorphous Cu 45 Zr 55 (at.%) multilayer structure was fabricated with the two crystalline layers sputter deposited between the top-middle-bottom amorphous layers and prepared to electron transparency. The multilayer was then in situ indented either under a single load to a depth of ~ 100 nm (max load of ~ 100 μN) or held at 20 μN and then repeatedly indented with an additional 5 μN up to 20,000 cycles in a transmission electron microscope to compare the deformation responses in the nanolaminate. For the single indentation test, the multilayer showed serrated load-displacement behavior upon initial indentation inductive of shear banding. Additionally, at an indentation depth of ~ 32 nm, the multilayer exhibited perfect plastic behavior and no strain hardening. Both indented and fatigue-indented films revealed diffraction contrast changes with deformation. Subsequent Automated Crystal Orientation Mapping (ACOM) measurements confirmed and quantified global texture changes in the crystalline layers with specifically identified grains revealing rotation. Using a finite element model, the in-plane displacement vectors under the indent mapped conditions where ACOM determined grain rotation was observed, indicating the stress flow induced grain rotation. Furthermore, the single indented Cu layers also exhibited evidence of deformation induced grain growth, which was not evident in the fatigue-indented Cu based multilayer. Finally, the single indented multilayer retained a significant plastic crater in the upper most amorphous layer that directly contacted the indenter; a negligible crater impression in the same region was observed in the fatigued tested multilayer. These differences are explained by the different loading methods, applied load, and deformation mechanisms experienced in the multilayers.

36 MATERIALS SCIENCE↗

Mechanical behavior of carbon-carbon composites

A general background, test plan, and some results of preliminary examinations of a carbon-carbon composite material are presented with emphasis on mechanical testing and inspection techniques. Experience with testing and evaluation was gained through tests of a low modulus carbon-carbon material, K-Karb C. The properties examined are the density - 1.55 g/cc; four point flexure strength in the warp - 137 MPa (19,800 psi) and the fill - 95.1 MPa (13,800 psi,) directions; and the warp interlaminar shear strength - 14.5 MPa (2100 psi). Radiographic evaluation revealed thickness variations and the thinner areas of the composite were scrapped. The ultrasonic C-scan showed attenuation variations, but these did not correspond to any of the physical and mechanical properties measured. Based on these initial tests and a survey of the literature, a plan has been devised to examine the effect of stress on the oxidation behavior, and the strength degradation of coated carbon-carbon composites. This plan will focus on static fatigue tests in the four point flexure mode in an elevated temperature, oxidizing environment.

Rozak, G. A.↗

Development of composite carrythrough bulkhead

A structural development program was recently completed in which the weight and fatigue advantages of an all composite major load carrying bulkhead was successfully demonstrated. Fabrication of a full scale article, including static and fatigue testing of the carry-through beam portion verified the producibility, strength and durability of this design, thereby presenting the opportunity for use on aircraft upgrades and new aircraft. A 15% weight saving is achievable and, more importantly, the fatigue problems that normally plague metal bulkheads are virtually eliminated.

Ehlen, R. J.↗

Advanced Face Gear Surface Durability Evaluations

The surface durability life of helical face gears and isotropic super-finished (ISF) face gears was investigated. Experimental fatigue tests were performed at the NASA Glenn Research Center. Endurance tests were performed on 10 sets of helical face gears in mesh with tapered involute helical pinions, and 10 sets of ISF-enhanced straight face gears in mesh with tapered involute spur pinions. The results were compared to previous tests on straight face gears. The life of the ISF configuration was slightly less than that of previous tests on straight face gears. The life of the ISF configuration was slightly greater than that of the helical configuration.

fatigue↗

Fatigue behavior of a single-crystal superalloy

A single-crystal superalloy, PWA 1480 is under consideration as a replacement material for the turbine blades of the high pressure fuel turbopump (HPFTP) of the space shuttle main engine (SSME). Three separate experimental programs were conducted to characterize the fatigue behavior of this alloy. Fatigue tests were conducted at room temperature (in air) and at 1000 F (in vacuum) on smooth specimens machined from both cast bars and slabs. The data from all of these programs are consolidated to provide a broader characterization of the fatigue behavior of the single crystal PWA 1480. The zero-mean-stress fatigue relationships are expressed in terms of stress range versus cyclic life lines on log-log plots. Characterization of the fatigue behavior of (001) oriented PWA 1480 single crystal under conditions of tensile mean stress was performed by using the unified approach proposed by Heidmann. In this approach the fatigue life is modified by a mean stress parameter so that a single life relationship can be used to represent both zero and tensile mean stress data.

Kalluri, Sreeramesh↗

Estimation of Slow Crack Growth Parameters for Constant Stress-Rate Test Data of Advanced Ceramics and Glass by the Individual Data and Arithmetic Mean Methods

The two estimation methods, individual data and arithmetic mean methods, were used to determine the slow crack growth (SCG) parameters (n and D) of advanced ceramics and glass from a large number of room- and elevated-temperature constant stress-rate ('dynamic fatigue') test data. For ceramic materials with Weibull modulus greater than 10, the difference in the SCG parameters between the two estimation methods was negligible; whereas, for glass specimens exhibiting Weibull modulus of about 3, the difference was amplified, resulting in a maximum difference of 16 and 13 %, respectively, in n and D. Of the two SCG parameters, the parameter n was more sensitive to the estimation method than the other. The coefficient of variation in n was found to be somewhat greater in the individual data method than in the arithmetic mean method.

Choi, Sung R.↗

Ultrasonic and optical evaluation of surgical implant materials and devices. A durability study of pericardial bioprostheses

Laser Doppler Anemometry (LDA) and accelerated fatigue testing were used in an attempt to assess the durability of two cardiac value bioprostheses. The LDA system was used to monitor the function of the cardiac valves over time. This was done through flow characterization in an aortic flow chamber, designed to closely simulate in vivo conditions, both in the near vicinity (sinuses of valsalva region) and also somewhat downstream (aortic region) from the values. The accelerated fatigue tester was operated by opening and closing the valves at a rate of 1300 R.P.M., about 18 x the normal rate. The results from the two test valves indicate a definite change in the flow characteristics downstream from the valve after certain accelerated test intervals. The high velocity cross-sectional flow area seems to increase over time in use, causing a decrease in the peak velocity. The tissue became more flaccid in certain areas, and tears were apparent at about 9.4 million cycles for the Ionescu-Shiley valve and at 24 million cycles for the Carpentier-Edwards valve. The use of Doppler ultrasound as a technique for monitoring the function of bioprostheses over time in vivo is also discussed.

Schuster, P. R.↗

Axial fatigue of /0, +30, and -30 deg/6s graphite/epoxy

Results are presented for an investigation carried out on a /0, +30, and -30 deg/6s graphite/epoxy angle-ply laminate in order to characterize the overall fatigue behavior, to evaluate strength/moduli degradation due to cyclic loading, and to identify the failure modes and mechanisms. The specimen life determined from fatigue tests is measured as a function of cyclic stress amplitude for various stress ratios. Fractured specimens are sectioned and examined by conventional metallography and SEM to reveal failure modes and mechanisms. It is shown that the laminate studied is susceptible to axial fatigue failures under cyclic loading which involves both tensile and compressive mean stresses. Fracture surface observations indicate the occurrence of complex failure modes. A variety of local failure mechanisms are identified.

Ramani, S. V.↗

The Influence of Surface Coatings on Exo-Electron Emission During Fatigue

A survey of exo-electron emission literature has shown that the mechanism of exo-emission phenomena has yet to be ascertained. Also, there is probably no unique mechanism that will apply to all the exo-emission observations reported. For exo-emission to occur, trapping centers must first be formed to store electrons. Once such centers are formed, they can be made to give up their trapped electrons by the stimulation of light or oxygen. Future investigations will employ light-transparent films for collecting exo-electrons. Also, a carefully controlled experiment is necessary to detect the emission of exo-electrons from the surface of fatiguing metals. Investigations will include high-vacuum fatigue tests, autoradiography, and solid state collector experiments, and will provide a basis for future research on semiconductor layer collection.

COATING↗

The application of 'strain range partitioning method' to torsional creep-fatigue interaction

The method of strain range partitioning was applied to a series of torsional fatigue tests conducted on tubular 304 stainless steel specimens at 1200 F (649 C). Creep strain was superimposed on cycling strain, and the resulting strain range was partitioned into four components; completely reversed plastic shear strain followed by creep strain, creep strain followed by plastic strain and completely reversed creep strain. Each strain component was related to the cyclic life of the material. The paper describes the experimental procedure used to achieve strain partitioning and the torsional test results are compared to those obtained from axial tests. The damaging effects of the individual strain components were expressed by a linear life fraction rule. The shear strain plastic component showed the least detrimental factor when compared to creep strain reversal by plastic strain. In the latter case, a reduction of torsional fatigue life in the order of magnitude of 1.5 was observed.

Zamrik, S. Y.↗

Structural dynamic testing of composite propfan blades for a cruise missile wind tunnel model

The Naval Weapons Center at China Lake, California is currently evaluating a counter rotating propfan system as a means of propulsion for the next generation of cruise missiles. The details and results of a structural dynamic test program are presented for scale model graphite-epoxy composite propfan blades. These blades are intended for use on a cruise missile wind tunnel model. Both dynamic characteristics and strain operating limits of the blades are presented. Complications associated with high strain level fatigue testing methods are also discussed.

Elgin, Stephen D.↗

Debonding characteristics of adhesively bonded woven Kevlar composites

The fatigue damage mechanism of an adhesively bonded joint between fabric reinforced composite adherends was investigated with cracked-lap-shear specimens. Two bonded systems were studied: fabric Kevlar 49/5208 epoxy adherends bonded together with either EC 3445 or FM-300 adhesive. For each bonded system, two specimen geometries were tested. In all specimens tested, fatigue damage occurred in the form of cyclic debonding; however, the woven Kevlar specimens gave significantly slower debond growth rates and higher fracture toughness than previously found in the nonwoven adherend specimens. The surfaces for the woven adherends were not smooth; rather, they had regular crests (high spots) and troughs (low spots) due to the weave pattern. Radiographs of the specimens and examination of their failure surfaces revealed that fiber bridging occurred between the crests of the two adherends in the debonded region. The observed improvements in debond growth resistance and static fracture toughness are attributed to this bridging.

Mall, S.↗

Mechanical characterization of unnotched SCS6/Ti-15-3 metal matrix composites at room temperature

The Ti-15-3 metal matrix composites containing silicon-carbide (SCS6) fibers, in five different lay-ups, have been tested at room temperature to determine static strengths and mechanical properties. Experimental data and predicted values of the laminate properties and strengths showed good correlation. The off-axis laminate plies (that is, 90 and 45 deg) suffered fiber/matrix interface failures at stress levels as low as 20 ksi, thus significantly affecting the mechanical properties of the laminate. Edge replicas were used to verify the fiber/matrix separations. Microscopic examinations determined that the fiber/matrix failures were occurring in the titanium/silicon reaction layer. Fatigue tests were performed on unnotched specimens to determine the number of cycles to failure versus cyclic stress level. It was found that the stress in the 0 deg fiber could be used to correlate the fatigue life of different laminates containing 0 deg plies.

Johnson, W. S.↗