Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electron cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Radiant heating tests of several liquid metal heat-pipe sandwich panels

Integral heat-pipe sandwich panels, which synergistically combine the thermal efficiency of heat pipes and the structural efficiency of honeycomb sandwich construction, were conceived as a means of alleviating thermal stress problems in the Langley Scramjet Engine. Test panels which utilized two different wickable honeycomb cores, facesheets with screen mesh sintered to the internal surfaces, and a liquid metal working fluid (either sodium or potassium) were tested by radiant heating at various heat-load levels. The heat-pipe panels reduced maximum temperature differences by 31 percent with sodium working fluid and 45 percent with potassium working fluid. Results indicate that a heat-pipe sandwich panel is a potential, simple solution to the engine thermal stress problem. Other interesting applications of the concept include: cold plates for electronic component and circuit card cooling, radiators for large space platforms, low-distortion large area structures (e.g., space antennas) and laser mirrors.

Camarda, C. J.↗

A numerical study of the stability of radiative shocks

Attention is given to the oscillatory instability of optically thin radiative shocks in time-dependent numerical calculations of accretion flows onto degenerate dwarfs. The present nonlinear calculations yield good quantitative agreement with the linear results obtained for oscillation frequencies, damping rates, and critical alpha-values. The fundamental mode and the first overtone in the shock radius and luminosity variations can be clearly identified, and evidence is sometimes seen for the second overtone. Time-dependent calculations are also performed which include additional physics relevant to degenerate dwarf accretion, such as electron thermal conduction, unequal electron and ion temperatures, Compton cooling, and relativistic corrections to the bremsstrahlung cooling law. All oscillatory modes are found to be damped, and hence stable, in the case of a 1-solar mass white dwarf accreting in spherical symmetry.

Imamura, J. N.↗

Loop interaction in the visible emission corona: Morphological details

Coronagraph observations of two post flare loop systems, recorded photographically in the emissions of Fe 14 (5303 A) and Fe 10 (6374 A), show occasional enhancements at the intersections of some loops. The brightness of such enhancements in the green line gradually increases to a maximum value several times greater than that of the legs of the loops and then declines with a typical lifetime approx. 30 to 60 min. In red line emission the loop systems are usually very faint, but show the same overall type of enhancement, with a lag in maximum brightness relative to that of the green line approx. 10 min. The electron density, derived from the cooling time, is approx. 10 to the 12th power/cu cm.

Smartt, Raymond N.↗

Integration and use of Microgravity Research Facility: Lessons learned by the crystals by vapor transport experiment and Space Experiments Facility programs

The Crystals by Vapor Transport Experiment (CVTE) and Space Experiments Facility (SEF) are materials processing facilities designed and built for use on the Space Shuttle mid deck. The CVTE was built as a commercial facility owned by the Boeing Company. The SEF was built under contract to the UAH Center for Commercial Development of Space (CCDS). Both facilities include up to three furnaces capable of reaching 850 C minimum, stand-alone electronics and software, and independent cooling control. In addition, the CVTE includes a dedicated stowage locker for cameras, a laptop computer, and other ancillary equipment. Both systems are designed to fly in a Middeck Accommodations Rack (MAR), though the SEF is currently being integrated into a Spacehab rack. The CVTE hardware includes two transparent furnaces capable of achieving temperatures in the 850 to 870 C range. The transparent feature allows scientists/astronauts to directly observe and affect crystal growth both on the ground and in space. Cameras mounted to the rack provide photodocumentation of the crystal growth. The basic design of the furnace allows for modification to accommodate techniques other than vapor crystal growth. Early in the CVTE program, the decision was made to assign a principal scientist to develop the experiment plan, affect the hardware/software design, run the ground and flight research effort, and interface with the scientific community. The principal scientist is responsible to the program manager and is a critical member of the engineering development team. As a result of this decision, the hardware/experiment requirements were established in such a way as to balance the engineering and science demands on the equipment. Program schedules for hardware development, experiment definition and material selection, flight operations development and crew training, both ground support and astronauts, were all planned and carried out with the understanding that the success of the program science was as important as the hardware functionality. How the CVTE payload was designed and what it is capable of, the philosophy of including the scientists in design and operations decisions, and the lessons learned during the integration process are descussed.

Heizer, Barbara L.↗

Temperature, N2, and N density profiles of Triton's atmosphere - Observations and model

Improved analysis of the Voyager Ultraviolet Spectrometer observations of the solar occultation by Triton yields the isothermal temperature and N2 number densities in the altitude range 475-675 km. The signature of atomic nitrogen in the occultation spectra is identified, its density profile is derived, and an experimental value of the escape rate of N atoms is given. The one-dimensional thermal conductivity equation for a spherical atmosphere is solved, taking into account CO heating and cooling and heating by precipitating electrons, solar radiation, and chemical effects. Finally, profiles of number densities of N, H2, and H are calculated.

Krasnopolsky, V. A.↗

A Multiwavelength Study of the Extreme AGN J2310-437

We present new X-ray, radio, and optical data for the unusual galaxy/cluster system J2310-437. Our results confirm the presence of an active nucleus and suggest an interpretation as an anomalous BL Lac object of bulk relativistic Doppler factor <2, with an optically deficient radio to X-ray spectrum. The radio, optical, and soft X-ray flux densities could lie along a single power-law function, lacking the curvature typical of BL Lac objects. Compared with other known sources that may have comparable multi-frequency spectra, J2310-437 is the most extreme. Its low isotropic optical/Ultraviolet (UV) radiation is consistent with the intensity of external photons governing the electron spectral break through Compton cooling; in this source the external photon density would be too low to produce a spectral break below the X-ray.

Worrall, D. M.↗

A Materials Compatibility and Thermal Stability Analysis of Common Hydrocarbon Fuels

A materials compatibility and thermal stability investigation was conducted using five common liquid hydrocarbon fuels and two structural materials. The tests were performed at the NASA Glenn Research Center Heated Tube Facility under environmental conditions similar to those encountered in regeneratively cooled rocket engines. Scanning-electron microscopic analysis in conjunction with energy dispersive spectroscopy (EDS) was utilized to characterize the condition of the tube inner wall surface and any carbon deposition or corrosion that was formed during selected runs. Results show that the carbon deposition process in stainless steel tubes was relatively insensitive to fuel type or test condition. The deposition rates were comparable for all fuels and none of the stainless steel test pieces showed any signs of corrosion. For tests conducted with copper tubing, the sulfur content of the fuel had a significant impact on both the condition of the tube wall and carbon deposition rates. Carbon deposition rates for the lowest sulfur fuels (2 ppm) were slightly higher than those recorded in the stainless steel tubes with no corrosion observed on the inner wall surface. For slightly higher sulfur content (25 ppm) fuels, nodules that intruded into the flow area were observed to form on the inner wall surface. These nodules induced moderate tube pressure drop increases. The highest sulfur content fuels (400 ppm) produced extensive wall pitting and dendritic copper sulfide growth that was continuous along the entire tube wall surface. The result of this tube degradation was the inability to maintain flow rate due to rapidly increasing test section pressure drops. Accompanying this corrosion were carbon deposition rates an order of magnitude greater than those observed in comparable stainless steel tests. The results of this investigation indicate that trace impurities in fuels (i.e. sulfur) can significantly impact the carbon deposition process and produce unacceptable corrosion levels in copper based structural materials.

Meyer, M. L.↗

First Results from NuSTAR Observations of Mkn 421

Mkn 421 is a nearby active galactic nucleus dominated at all wavelengths by a very broad nonthermal continuum thought to arise from a relativistic jet seen at a small angle to the line of sight. Its spectral energy distribution peaks in the X-ray and TeV gamma-ray bands, where the energy output is dominated by cooling of high-energy electrons in the jet. In order to study the electron distribution and its evolution, we carried out a dedicated multi-wavelength campaign, including extensive observations by the recently launched highly sensitive hard X-ray telescope NuSTAR, between December 2012 and May 2013. Here we present some intial results based on NuSTAR data from January through March 2013, as well as calibration observations conducted in 2012. Although the observations cover some of the faintest hard X-ray flux states ever observed for Mkn 421, the sensitivity is high enough to resolve intra-day spectral variability. We find that in this low state the dominant f ux variations are smooth on timescales of hours, with typical intra-hour variations of approximately less than 5%. We do not find evidence for either a cutoff in the hard X-ray spectrum, or a rise towards a high-energy component, but rather that at low flux the spectrum assumes a power law shape with a photon index of approximately 3. The spectrum is found to harden with increasing brightness.

active galactic nuclei (AGN)↗

A 4 x 4 SiPM Sensor Array with Fast Preamplified Output Engineered for the PWO Detectors of the EIC EEEMCAL

The PbWO4 scintillation detectors for the Electron-Ion Collider Electron Endcap Electromagnetic Calorimeter (EEEMCAL) cannot use vacuum photomultipler tubes due to the high magnetic field environment. We are presenting a readout solution with a 4 x 4 SiPM array directly coupled to a preamplification and summing stage. A second amplification stage with variable gain and offset adjustments is also included in the compact electronics module. The integrated power supply feeds the signal processing chain and the adjustable bias control. The parameter settings are saved locally on a EEPROM and are adjustable via the integrated communication interface through USB or RS485. The design was optimized to maximize signal collection energy resolution, for fast timing and wide dynamic range while keeping a small footprint with low power consumption and heat dissipation. The output response is fast enough to meet the 100 ? 200 ns digitization gate requirements for the detector. The electronics assembly requires no active cooling and includes a temperature sensor and a gain compensation of thermal variations which are important features for stable operation in large scale detector structures. A detector prototype was constructed with 20 mm x 20 mm x 200 mm PWO crystals affixed with individual SiPM array readouts and arranged in a 3 x 3 array. This detector was tested at the Thomas Jefferson National Accelerator Facility with 5GeV positrons. We will present the results of these detector characterization measurements.

Philip, O.↗

First Detection of 120 GeV Protons with Superconducting Nanowire Detectors

We report the test results for a 120 GeV proton beam incident on superconducting nanowire particle detectors of various wire sizes. NbN devices with the same sensitive area were fabricated with different wire widths and tested at a temperature of 3 K. The relative detection efficiency was extracted from bias current scans for each device. The results demonstrate efficient detection of high energy protons for wire widths less than 400 nm. These results are particularly relevant for novel applications at accelerator facilities, such as the Electron-Ion Collider, where cryogenic cooling is readily available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Functionalized carbon nanotubes for thermionic emission and cooling applications

Barium strontium oxide-coated carbon nanotubes (CNTs) were implemented as a work function lowering and field enhancing functional coating on a coiled tungsten filament to create a new thermionic cathode. This cathode resembles conventional oxide cathodes in structure. It has the same coiled tungsten filament as a conventional oxide cathode but uses barium strontium oxide-coated CNTs instead of the traditional barium strontium calcium oxide powder mixture as an emissive coating. The cathode produces a strong thermionic emission. At 1395 K and 2.5 V/μm, the thermionic emission current of 0.87 A or current density of 2.9 A/cm 2 was obtained from this oxide-coated CNT cathode. This level of emission is about three times as large as a conventional oxide cathode operating at similar temperature and field strength. Strong thermionic emissions from the cathode also lead to a large thermionic cooling effect. Temperature reduction as large as 90° was observed from the cathode surface when it was emitting electrons. Strong thermionic emission and a large cooling effect obtained are the result of the combination of the low work function of barium strontium oxide (1.6 eV) and the large field effect induced by the CNTs. Plasma enhanced chemical vapor deposition was used to grow CNTs, and magnetron sputtering deposition was used to deposit the barium strontium oxide functional coating; details of the cathode fabrication are presented to illustrate both the versatility of the processing techniques and the adaptability of barium strontium oxide-coated CNTs as a functional coating. Finally, measurements on thermionic emission and thermionic cooling of the cathode are also presented.

36 MATERIALS SCIENCE↗

Passive Thermal Control of the Primordial Inflation Polarization Explorer (PIPER) Flight Electronics

The scientific balloon program at NASA offers an exciting and open area of opportunity for testing new technologies and for conducting meaningful experimentation at a fraction of the cost of a space mission. This paper outlines a simple thermal model developed and employed for the Primordial Inflation Polarization ExplorER (PIPER). The sub-orbital environment that PIPER operates in hosts an interesting mix of atmospheric and space thermal challenges. The work done was to mitigate thermal loads and passively cool the payload's exterior mounted electronics at an altitude of 36.6 km. This was done by characterizing the thermal environment and then designing solutions for the heat loads through a combined radiation and conduction passive cooling radiator system thermal model. Despite the simplicity and subsequent limitations of the model, as well as some unexpected payload operational events, the model produced results between 0.31% and 11.8% difference between the predicted values and measured average temperatures. From these results, the model was able to successfully provide estimates for the electronics temperatures. Additional flights will be needed to eliminate unknowns encountered in this flight in order to further refine the model for higher accuracy.

Walts, Alexander R.↗

Experiments On A Conduction Cooled Superconducting Radio Frequency Cavity With Field Emission Cathode

To achieve Ampere-class electron beam accelerators the pulse delivery rate need to be much higher than the typical photo injector repetition rate of the order of a few kilohertz. We propose here an injector which can, in principle, generate electron bunches at the same rate as the operating RF frequency. A conduction-cooled superconducting radio frequency (SRF) cavity operating in the CW mode and housing a field emission element at its region of high axial electric field can be a viable method of generating high-repetition-rate electron bunches. In this paper, we report the development and experiments on a conduction-cooled Nb3Sn cavity with a niobium rod intended as a field emitter support. The initial experiments demonstrate 0.4 MV/m average accelerating gradient, which is equivalent of peak gradient of 3.2 MV/m. The measured RF cavity quality factor is 1.4 x 10$^8$ slightly above our goal. The achieved field gradient is limited by the relatively low input RF power and by the poor coupling between the external power supply and the RF cavity. With ideal coupling the field gradient can be as high as 0.6 MV/m still below our goal of about 1 MV/m.

43 PARTICLE ACCELERATORS↗

A Simplified Model of VIPER Thermal Management System. Part II: Integrated Vehicle

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) thermal management system (TMS) relies on four loop heat pipes (LHPs) to transport electronic waste heat to the vehicle cooling radiative surface and avoid overheating. The TMS has also ten constant conductance heat pipes (CCHPs) dedicated to balance the thermal load within the internal environment where the avionics boxes are mounted, also called warm electronic box (WEB), and to transport the heat from two of the science payload instruments. The TMS also uses two thermal straps to thermally link the batteries to the WEB. These thermal components, in addition to heaters, thermostat, multi-layer insulation (MLIs), and isolators forms the core of the VIPER TMS. The complex heat transport balance managed by the TMS is challenging to characterize and model. The more fidelity and granularity of a model, the more costly the computational resources needed and the longer the simulation and modeling time. When the priority is to provide quick but reliable assessments of the thermal performance or real time thermal feedback for training of console operators, simplified modeling tools are needed. To satisfy that need, this paper describes the effort to develop and correlate a model of VIPER TMS based on control volume approach. The correlation effort in particular focuses on hibernation, cold thermal balance, and hot thermal balance data from the integrated vehicle thermal vacuum (TVAC) test. Thus, the correlated model captures the heat leaks during hibernations and the performance at two extremes, bounding, operating scenarios.

Loop Heat Pipe↗

A Simplified Model of VIPER Thermal Management System. Part II: Integrated Vehicle

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) thermal management system (TMS) relies on four loop heat pipes (LHPs) to transport electronic waste heat to the vehicle cooling radiative surface and avoid overheating. The TMS has also ten constant conductance heat pipes (CCHPs) dedicated to balance the thermal load within the internal environment where the avionics boxes are mounted, also called warm electronic box (WEB), and to transport the heat from two of the science payload instruments. The TMS also uses two thermal straps to thermally link the batteries to the WEB. These thermal components, in addition to heaters, thermostat, multi-layer insulation (MLIs), and isolators forms the core of the VIPER TMS. The complex heat transport balance managed by the TMS is challenging to characterize and model. The more fidelity and granularity of a model, the more costly the computational resources needed and the longer the simulation and modeling time. When the priority is to provide quick but reliable assessments of the thermal performance or real time thermal feedback for training of console operators, simplified modeling tools are needed. To satisfy that need, this paper describes the effort to develop and correlate a model of VIPER TMS based on control volume approach. The correlation effort in particular focuses on hibernation, cold thermal balance, and hot thermal balance data from the integrated vehicle thermal vacuum (TVAC) test. Thus, the correlated model captures the heat leaks during hibernations and the performance at two extremes, bounding, operating scenarios.

Thermal Modeling↗

Luminosity and beam-induced background studies for the Cool Copper Collider

A high-energy electron-positron collider has been widely recognized by the particle physics community to be the next crucial step for detailed studies of the Higgs boson and other fundamental particles and processes. Several proposals for such colliders, either linear or circular, are currently under evaluation. Any such collider will be required to reach high lumimosities, in order to collect enough data at a reasonable time scale, while at the same time coping with high rates of background particles produced from beam-beam interactions during the collisions. In this paper, we analyze the luminosity and beam-beam interaction characteristics of the Cool Copper Collider ( C 3 ) and perform a comparison with other linear collider proposals. We conclude that C 3 can reach the same or higher collision rates as the other proposals, without having to cope with higher beam-induced background fluxes. Thus, C 3 emerges as an attractive option for a future electron-positron collider, benefiting from the collective advancements in beam delivery and final focus system technologies developed by other linear collider initiatives. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Estimates of Damped Energy Spread and Emittance in a Two Energy Storage Ring Cooler

In this paper we provide estimates of the damped energy spread and emittance in a two-energy storage ring cooler. Two energy storage rings have two loops at markedly different energies, one at low energy and the other at high energy. In a cooling application the low energy ring has a cooling section to cool the ion beam and the high energy ring may have a wiggler section to enhance the damping effect on electron beam. The linear optics in the cooling section is designed to attain the maximum cooling of ion beams. Similarly, the linear optics in the wiggler section is designed to attained the required equilibrium emittance and energy spread. Hence, the radiation events in these two rings are different and independent. Since the values of damped energy spread and emittance depend on a range of parameters related to lattice design and rings energies, we present analytical calculations along with simulation results to estimate the values of damped energy spread and emittance in a two energy storage ring cooler.

Dhital, B.↗