Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EXIT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Simulation of a non-equilibrium helium plasma bullet emerging into oxygen at high pressure (250–760 Torr) and interacting with a substrate

A two-dimensional computational study of a plasma bullet emanating from a helium gas jet in oxygen ambient at high pressure (250–760 Torr) was performed, with emphasis on the bullet interaction with a substrate. Power was applied in the form of a trapezoidal +5 kV pulse lasting 150 ns. A neutral gas transport model was employed to predict the concentration distributions of helium and oxygen in the system. These were then used in a plasma dynamics model to investigate the characteristics of the plasma bullet during its propagation and interaction with a substrate. Upon ignition, the discharge first propagated as a surface wave along the inner wall of the containing tube, and then exited the tube with a well-defined ionization front (streamer or plasma bullet). The plasma bullet evolved from a hollow (donut-shaped) feature to one where the maximum of ionization was on axis. The bullet propagated in the gap between the tube exit and the substrate with an average speed of ~2 × 10 5 m/s. Upon encountering a metal substrate, the bullet formed a conductive channel to the substrate. Upon encountering a dielectric substrate, the bullet turned into an ionization wave propagating radially along the substrate surface. For a conductive substrate, the radial species fluxes to the surface peaked on the symmetry axis. For a dielectric substrate, a ring-shaped flux distribution was observed. The “footprint” of plasma-surface interaction increased either by decreasing the gap between tube exit and substrate, decreasing the relative permittivity of an insulating substrate, or decreasing pressure. As the system pressure was lowered from 760 to 250 Torr, the discharge was initiated earlier, and the plasma bullet propagation speed increased. A reverse electric field developed during the late stages of the ramp-down of the pulse, which accelerated electrons forming a brief backward discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Brome isotope selective control of CF{sub 3}Br molecule clustering by IR laser radiation in gas-dynamic expansion of CF{sub 3}Br – Ar mixture

We report the results of research on the experimental control of CF{sub 3}Br molecule clustering under gas-dynamic expansion of the CF{sub 3}Br – Ar mixture at a nozzle exit by using IR laser radiation. A cw CO{sub 2} laser is used for exciting molecules and clusters in the beam and a time-of-flight mass-spectrometer with laser UV ionisation of particles for their detection. The parameters of the gas above the nozzle are determined (compositions and pressure) at which intensive molecule clustering occurs. It is found that in the case of the CF{sub 3}Br gas without carrier when the pressure P{sub 0} above the nozzle does not exceed 4 atm, molecular clusters actually are not generated in the beam. If the gas mixture of CF{sub 3}Br with argon is used at a pressure ratio 1 : N, where N ⩾ 3, and the total pressure above the nozzle is P{sub 0} ⩾ 2 atm, then there occurs molecule clustering. We study the dependences of the efficiency of suppressing the molecule clustering on parameters of the exciting pulse, gas parameters above the nozzle, and on a distance of the molecule irradiation zone from the nozzle exit section. It is shown that in the case of resonant vibrational excitation of gas-dynamically cooled CF{sub 3}Br molecules at the nozzle exit one can realise isotope-selective suppression of molecule clustering with respect to bromine isotopes. With the CF{sub 3}Br – Ar mixtures having the pressure ratio 1 : 3 and 1 : 15, the enrichment factors obtained with respect to bromine isotopes are k{sub enr} ≈ 1.05 ± 0.005 and k{sub enr} ≈ 1.06 ± 0.007, respectively, under jet irradiation by laser emission in the 9R(30) line (1084.635 cm{sup −1}). The results obtained let us assume that this method can be used to control clustering of molecules comprising heavy element isotopes, which have a small isotopic shift in IR absorption spectra. (paper)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Suppression of clustering of CF{sub 3}Br molecules with argon atoms by CO{sub 2} laser radiation in gas-dynamic expansion of a CF{sub 3}Br–Ar mixture: bromine isotope selectivity

We present the study of suppressing the clustering of CF{sub 3}Br molecules with argon atoms under gas-dynamic expansion of the CF{sub 3}Br–Ar mixture at a nozzle exit by a cw CO{sub 2} laser. The main attention is paid to the analysis of possibility of implementing the selective control of bromine isotope clustering. The method relies on the vibrational excitation of molecules with the laser radiation, which leads to the suppression of their clustering with argon atoms. The experimental setup and the method of study are briefly described. The results of evaluation of the efficiency and selectivity of suppression of molecular–atomic clustering for different compositions of the gas above the nozzle and separations between the irradiation zone and the nozzle exit section are presented. It is shown that under the resonance vibrational excitation of gas-dynamically cooled CF{sub 3}Br molecules at the nozzle exit one can implement bromine isotope selective suppression of clustering of molecules with argon atoms. It is found that by controlling the clustering of CF{sub 3}Br molecules with argon atoms one can implement considerably higher enrichment and selectivity factors than in the case of controlling the clustering of CF{sub 3}Br molecules with each other. Thus, using the CF{sub 3}Br–Ar mixture (the ratio of pressures 1 : 100 and 1 : 200) the enrichment factors for the bromine isotopes K{sub enr}({sup 81}Br) = 1.50 ± 0.13 and 1.30 ± 0.09, respectively, were obtained under the conditions of irradiating the jet at the 9R(30) line of the laser (ν = 1084.635 cm{sup −1}). The selectivity α of the suppression of clustering of CF{sub 3}Br molecules with argon atoms, achieved in this case, amounted to 4.02 ± 0.19 and 2.31 ± 0.11, respectively. The results show that the method allows one to selectively control the clustering of molecules, comprising isotopes of heavy elements that possess a small isotopic shift in the IR absorption spectra. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multiphysics Analyses of the Bottom Components of the 3D Printed Transformational Challenge Reactor

This research presents multi-physics analyses on the bottom components of the Transformational Challenge Reactor (TCR) facility. These components include the bottom axial reflector and the steel exit cone. The bottom axial reflector is made of pure silicon carbide elements hosting helium cooling channels These elements are 3D printed and therefore can host any arbitrary shape of the helium cooling channels. The design of the bottom reflector considers the neutronics and thermo-fluid dynamics performances as well as the manufacturing process optimization. More precisely, the best design of the bottom reflector reduces neutron leakage by avoiding straight cylindrical helium channels that facilitate neutron leakage, minimizes the helium flow pressure drop, and reduces the number of 3D printed silicon carbide pieces. The exit cone steel structure collects the hot helium from the bottom fuel assemblies and channels the cold helium to the top of the fuel assemblies. The steel simultaneous contact with hot and cold helium flows sets a large thermal gradient. Different designs of the exit cone are proposed to reduce the steel equivalent stress from the helium thermal load. The multi-physics analyses have been performed using Ansys Fluent, Ansys Mechanical, STAR-CCM+, and Serpent computer programs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Accuracy of volumetric flow rate inflow/outflow measurement by integrating PIV velocity fields

In this paper, the usefulness of planar Particle Image Velocimetry (PIV) measurements to determine the volumetric flow rate from a rectangular or round jet exit is assessed. Both two-component PIV (2C–PIV) and through-plane three-component (3C) stereo PIV (SPIV) data sets were acquired at the exit of a turbulent, rectangular nozzle and a round nozzle with Reynolds numbers between 10 000 and 100 000. The PIV data sets were processed using a variety of algorithms. The time-averaged results were then spatially integrated across the jet exits and compared to a calibrated flow meter. Recommendations for each method are developed and discussed with potential drawbacks. The accuracy of the measurement was found to be a weak function of the Reynolds number of the flow. Furthermore, two-component PIV was found to underestimate the volumetric flow rate by 1%–4% depending on the integration scheme and SPIV underestimated volumetric flow rate by 2%.

47 OTHER INSTRUMENTATION↗

Numerical evaluation of the bispectrum in multiple field inflation—the transport approach with code

We present a complete framework for numerical calculation of the power spectrum and bispectrum in canonical inflation with an arbitrary number of light or heavy fields. Our method includes all relevant effects at tree-level in the loop expansion, including (i) interference between growing and decaying modes near horizon exit; (ii) correlation and coupling between species near horizon exit and on superhorizon scales; (iii) contributions from mass terms; and (iv) all contributions from coupling to gravity. We track the evolution of each correlation function from the vacuum state through horizon exit and the superhorizon regime, with no need to match quantum and classical parts of the calculation; when integrated, our approach corresponds exactly with the tree-level Schwinger or 'in-in' formulation of quantum field theory. In this paper we give the equations necessary to evolve all two- and three-point correlation functions together with suitable initial conditions. The final formalism is suitable to compute the amplitude, shape, and scale dependence of the bispectrum in models with | f {sub NL}| of order unity or less, which are a target for future galaxy surveys such as Euclid, DESI and LSST. As an illustration we apply our framework to a number of examples, obtaining quantitatively accurate predictions for their bispectra for the first time. Two accompanying reports describe publicly-available software packages that implement the method.

79 ASTRONOMY AND ASTROPHYSICS↗

Determination of muon momentum in the MicroBooNE LArTPC using an improved model of multiple Coulomb scattering

Here, we discuss a technique for measuring a charged particle's momentum by means of multiple Coulomb scattering (MCS) in the MicroBooNE liquid argon time projection chamber (LArTPC). This method does not require the full particle ionization track to be contained inside of the detector volume as other track momentum reconstruction methods do (range-based momentum reconstruction and calorimetric momentum reconstruction). We motivate use of this technique, describe a tuning of the underlying phenomenological formula, quantify its performance on fully contained beam-neutrino-induced muon tracks both in simulation and in data, and quantify its performance on exiting muon tracks in simulation. Using simulation, we have shown that the standard Highland formula should be re-tuned specifically for scattering in liquid argon, which significantly improves the bias and resolution of the momentum measurement. With the tuned formula, we find agreement between data and simulation for contained tracks, with a small bias in the momentum reconstruction and with resolutions that vary as a function of track length, improving from about 10% for the shortest (one meter long) tracks to 5% for longer (several meter) tracks. For simulated exiting muons with at least one meter of track contained, we find a similarly small bias, and a resolution which is less than 15% for muons with momentum below 2 GeV/c. Above 2 GeV/c, results are given as a first estimate of the MCS momentum measurement capabilities of MicroBooNE for high momentum exiting tracks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of reactions for the production of {sup 258,257}Db: {sup 208}Pb({sup 51}V,xn) and {sup 209}Bi({sup 50}Ti,xn)

Excitation functions for the 1n and 2n exit channels of the {sup 208}Pb({sup 51}V,xn){sup 259-x}Db reaction were measured. A maximum cross section of the 1n exit channel of 2070{sub -760}{sup +1100} pb was measured at an excitation energy of 16.0 {+-} 1.8 MeV. For the 2n exit channel, a maximum cross section of 1660{sub -370}{sup +450} pb was measured at 22.0 {+-} 1.8 MeV excitation energy. The 1n excitation function for the {sup 209}Bi({sup 50}Ti,n){sup 258}Db reaction was remeasured, resulting in a cross section of 5480{sub -1370}{sup +1730} pb at an excitation energy of 16.0 {+-} 1.6 MeV, in agreement with previous values [F. P. Hessberger et al., Eur. Phys. J. A 12, 57 (2001)]. Differences in cross section maxima are discussed in terms of the fusion probability below the barrier.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CMB quadrupole depression produced by early fast-roll inflation: Monte Carlo Markov chains analysis of WMAP and SDSS data

Generically, the classical evolution of the inflaton has a brief fast-roll stage that precedes the slow-roll regime. The fast-roll stage leads to a purely attractive potential in the wave equations of curvature and tensor perturbations (while the potential is purely repulsive in the slow-roll stage). This attractive potential leads to a depression of the CMB quadrupole moment for the curvature and B-mode angular power spectra. A single new parameter emerges in this way in the early universe model: the comoving wave number k{sub 1} characteristic scale of this attractive potential. This mode k{sub 1} happens to exit the horizon precisely at the transition from the fast-roll to the slow-roll stage. The fast-roll stage dynamically modifies the initial power spectrum by a transfer function D(k). We compute D(k) by solving the inflaton evolution equations. D(k) effectively suppresses the primordial power for k<k{sub 1} and possesses the scaling property D(k)={psi}(k/k{sub 1}) where {psi}(x) is a universal function. We perform a Monte Carlo Markov chain analysis of the WMAP and SDSS data including the fast-roll stage and find the value k{sub 1}=0.266 Gpc{sup -1}. The quadrupole mode k{sub Q}=0.242 Gpc{sup -1} exits the horizon earlier than k{sub 1}, about one-tenth of an e-fold before the end of fast roll. We compare the fast-roll fit with a fit without fast roll but including a sharp lower cutoff on the primordial power. Fast roll provides a slightly better fit than a sharp cutoff for the temperature-temperature, temperature-E modes, and E modes-E modes. Moreover, our fits provide nonzero lower bounds for r, while the values of the other cosmological parameters are essentially those of the pure {lambda}CDM model. We display the real space two point C{sup TT}({theta}) correlator. The fact that k{sub Q} exits the horizon before the slow-roll stage implies an upper bound in the total number of e-folds N{sub tot} during inflation. Combining this with estimates during the radiation dominated era we obtain N{sub tot}{approx}66, with the bounds 62<N{sub tot}<82. We repeated the same analysis with the WMAP-5, ACBAR-2007, and SDSS data confirming the overall picture.

79 ASTRONOMY AND ASTROPHYSICS↗

A Quasi-Periodic Linear Feeder for the Impurity Granular Injection on DIII-D

Injection of solid nonfuel pellets has been actively used as a tool for pacing and mitigation of edge localized modes (ELMs). In DIII-D, effective ELM pacing has been demonstrated by the high-frequency injection of lithium and carbon submillimeter spheres, using the impurity granule injector (IGI). This device injects granules into the plasma at speeds up to 150 m/s, through impact with a rotating impeller. In the IGI, high-frequency granule delivery was accomplished through a vibrational granule dropper, in which high time-average rates are obtained at the cost of lack of period control. Here, we present a new in-line granule feeder, capable of delivering granules of size 0.2-2 mm with no restriction of material properties, at quasi-periodic rates of up to 150 Hz, for 0.7-mm diameter lithium granules (600 Hz using 0.3-mm granules). The new dropper mechanism combines two piezo-in-line units; one which feeds the impeller and one which circulates granules that are filtered out of the feeder path. A remotely adjustable filter eliminates granules that are stacked, oversized, or side by side allowing the formation of a single moving granule injection line. The granules fall off the in-line feeder exit one at a time, achieving a quasi-periodic delivery rate proportional to the exit speed. At higher rates, the periodicity deteriorates. This behavior was studied using high-speed cameras and electrostatic measurements, and it was found that at drop rates <60 Hz, the granule delivery period has a variation of ±25% which appears to be caused by gaps which develop in the last centimeter of the injection line, as granules exit off the moving track. The linear feeder concept is robust against bridge instabilities and clogging issues, thanks to the simple diverter filter and constant recirculation of granules. Furthermore, the open-top design of the device facilitates refilling the device from separate reservoirs and has easy access for directly monitoring operation and adjustment. This paper describes the details of the in-line feeder design, along with several design iterations. The goal is a robust in-vacuum mechanism that can deliver granule flow ranging from a single particle to a line of particles at 150 per second, using different sizes and materials from the same apparatus.

42 ENGINEERING↗

X-Ray Phase Contrast Imaging of Liquid Film and Spray Development Inside an Aircraft Engine Swirler

Modern aircraft engines combine liquid fuel and air using an intricate flow device with many fuel and air flow passages. To date, the process by which the fuel atomizes within this swirler set has not been examined directly due to optical access limitations. In this work, high-speed X-ray phase-contrast imaging of a liquid spray inside a gas turbine engine swirler geometry is presented. Measurements were carried out at the 7-BM beamline of the Advanced Photon Source at Argonne National Laboratory using the high-energy broadband X-ray beam. The synchrotron X-ray source provides the necessary photon energy and flux to capture time-resolved fluid phenomena within the confines of the relevant geometry while liquid and air are flowing. Spray nozzle hardware and geometries were provided by the National Jet Fuels Combustion Program (NJFCP), allowing for characterization of the spray using a commercially relevant configuration. Modified swirlers were three-dimensional printed with acrylic to improve imaging access while maintaining influential internal features. Water was used as a surrogate fluid for these studies to demonstrate the visualization capabilities. The experiments were conducted at atmospheric exit pressure conditions with a pressure drop of 6% across the swirler. High-speed imaging of the pilot spray cone revealed sheet breakup several millimeters downstream of the orifice exit, upon interaction with the radial assist air flow. These droplets and ligaments were observed to impinge on the inner filming surface of the swirler and flow toward the exit while developing a tangential flow. Under these conditions, the liquid film grows up to several hundred microns in thickness on the filming surface, and subsequently forms ligaments up to several millimeters in length before breaking up. This work demonstrates the capability of X-ray diagnostics in visualizing liquid flows within solid geometries of technical relevance. Furthermore, the spatial quantification of filming flows and liquid interaction with the swirler air provides validation data for modeling of the multiphase flows and surface interactions within the swirler.

Sforzo, Brandon A.↗

Experimental Investigation of Sweeping Jet Film Cooling in a Transonic Turbine Cascade

Abstract The sweeping jet (SJ) film cooling hole has shown promising cooling performance compared to the standard shaped hole in low-speed conditions. The present work demonstrates the first attempt of SJ film cooling at an engine relevant Mach number. An experimental investigation was conducted to study the SJ film cooling on a nozzle guide vane suction surface. A well-established additive manufacturing technique commonly known as stereolithography (SLA) was utilized to design a transonic, engine representative vane geometry in which a row of SJ holes was used on the vane suction surface. Experiments were performed in a linear transonic cascade at an exit Mach number of 0.8 and blowing ratios of BR = 0.25–2.23. The measurement of heat transfer was conducted with the transient IR method, and the convective heat transfer coefficient (HTC) and adiabatic film cooling effectiveness were estimated using a dual linear regression technique (DLRT). Aerodynamic loss measurements were also performed with a total pressure Kiel probe at 0.25Cax downstream of the exit plane of the vane cascade. Experiments were also conducted for a baseline-shaped hole (777-hole) for a direct comparison. Results showed that the SJ hole has a wider coolant spreading in the lateral direction near the hole exit due to its sweeping motion that improves the overall cooling performance particularly at high blowing ratios (BR > 1). Aerodynamic loss measurement suggested that the SJ hole has a comparable total pressure loss to the 777-shaped hole.

Engineering↗

Large-Eddy Simulation Study of Flow and Combustion Dynamics in a Full-Scale Hydrogen–Air Rotating Detonation Combustor-Stator Integrated System

In the present work, a first-of-its-kind three-dimensional (3D) large-eddy simulation (LES) study is conducted to numerically investigate the combustion dynamics as well as aero-thermal phenomena in a full-scale nonpremixed hydrogen–air rotating detonation engine (RDE) (with a diverging-shaped lower-end wall), when integrated with nozzle guide vanes (NGV) acting as the turbine stator. The wall-modeled LES framework incorporates hydrogen–air detailed chemical kinetics and adaptive mesh refinement (AMR). A comparative analysis is carried out for two operating conditions with different fuel/air mass flow rates but global equivalence ratio of unity, and considering RDE configurations without and with stator. The LES model is validated against available experimental data for the low mass flux condition with respect to detonation wave speed/height, wave dynamics, and axial static pressure distribution. Numerical results indicate significant deflagrative combustion occurring in the fill region near the inner wall due to formation of recirculation zones in the injection near-field driven by the backward facing step. The leading detonation wave is found to be trailed by an azimuthal reflected-shock combustion (ARSC) wave, consistent with experimental observations, which consumes unburned vitiated reactants that leak through the main detonation wave. The main detonation wave characteristics, such as detonation wave speed/height and combustion efficiency, do not change appreciably with the presence of NGV. A novel combustion diagnostic technique based on chemical explosive mode analysis (CEMA) is employed to quantify the fraction of heat release occurring in the detonative mode versus deflagrative mode for the simulated conditions. The exit flow is found to be nearly fully subsonic and supersonic for the low and high mass flux conditions, respectively. Further analysis of the exit flow profiles shows that the presence of NGV renders the flow more axial and significantly impacts the exit Mach number and total pressure, while the total temperature shows negligible change. In addition, the low mass flux operating point, despite exhibiting more deflagrative losses within the combustor, yields overall lower pressure drop from plenum to exhaust, which is mainly attributed to lower pressure drop across the injectors. Lastly, the rotating detonation engine-nozzle guide vanes (RDE-NGV) configuration exhibits higher total pressure loss compared to rotating detonation engine (RDE) without stator across both the mass flux conditions. In conclusion, this study extends the state-of-the-art in numerical modeling of pressure gain combustion (PGC) systems by demonstrating high-fidelity 3D reacting LES of full-scale RDE-NGV systems relevant to RDE-turbine integration for stationary power generation.

Combustion↗

Hybrid method simulations of a soft x-ray beamline

A wavefront propagation analysis of a soft X-ray beamline using the HYBRID method is reported. All elements of the beamline: the energy dependence of the insertion device emission, the beamline mirrors and their measured figure errors, the variable-line-spacing grating and its measured figure error, and several exit slit settings, are included in the simulations. The analysis of the propagated undulator radiation through the beamline at two slightly different deflection parameter values demonstrates that, within the beamline angular acceptance and when the monochromator is tuned to the same energy, the flux is higher when the undulator is tuned to slightly higher energy than that of the monochromator. The energy resolution determined from the FWHM of the energy bandwidth transmitted through the exit slit is narrower when the undulator is tuned to higher energy than the monochromator. This is not the case when the resolution is based on the standard deviation of the transmitted energy band. The diffraction effects due to the exit slit size and their consequence on the spot size at the sample position are investigated for a few photon energies.

beamline↗

Treatment head disassembly to improve the accuracy of large electron field simulation

Purpose: The purposes of this study are to improve the accuracy of source and geometry parameters used in the simulation of large electron fields from a clinical linear accelerator and to evaluate improvement in the accuracy of the calculated dose distributions. Methods: The monitor chamber and scattering foils of a clinical machine not in clinical service were removed for direct measurement of component geometry. Dose distributions were measured at various stages of reassembly, reducing the number of geometry variables in the simulation. The measured spot position and beam angle were found to vary with the beam energy. A magnetic field from the bending magnet was found between the exit window and the secondary collimators of sufficient strength to deflect electrons 1 cm off the beam axis at 100 cm from the exit window. The exit window was 0.05 cm thicker than manufacturer's specification, with over half of the increased thickness due to water pressure in the channel used to cool the window. Dose distributions were calculated with Monte Carlo simulation of the treatment head and water phantom using EGSnrc, a code benchmarked at radiotherapy energies for electron scatter and bremsstrahlung production, both critical to the simulation. The secondary scattering foil and monitor chamber offset from the collimator rotation axis were allowed to vary with the beam energy in the simulation to accommodate the deflection of the beam by the magnetic field, which was not simulated. Results: The energy varied linearly with bending magnet current to within 1.4% from 6.7 to 19.6 MeV, the bending magnet beginning to saturate at the highest beam energy. The range in secondary foil offset used to account for the magnetic field was 0.09 cm crossplane and 0.15 cm inplane, the range in monitor chamber offset was 0.14 cm crossplane and 0.07 cm inplane. A 1.5%/0.09 cm match or better was obtained to measured depth dose curves. Profiles measured at the depth of maximum dose matched the simulated profiles to 2.6% or better at doses of 80% or more of the dose on the central axis. The profiles along the direction of MLC motion agreed to within 0.16 cm at the edge of the field. There remained a mismatch for the lower beam energies at the edge of the profile that ran parallel to the direction of jaw motion of up to 1.4 cm for the 6 MeV beam, attributed to the MLC support block at the periphery of the field left out of the simulation and to beam deflection by the magnetic field. The possibility of using these results to perform accurate simulation without disassembly is discussed. Phase-space files were made available for benchmarking beam models and other purposes. Conclusions: The match to measured large field dose distributions from clinical electron beams with Monte Carlo simulation was improved with more accurate source details and geometry details closer to manufacturer's specification than previously achieved.

61 RADIATION PROTECTION AND DOSIMETRY↗

Technical Note: Spatial resolution of proton tomography: Impact of air gap between patient and detector

Purpose: Proton radiography and tomography were investigated since the early 1970s because of its low radiation dose, high density resolution, and ability to image directly proton stopping power. However, spatial resolution is still a limiting factor. In this note, preliminary results of the impact of an air gap between detector system and patient on spatial resolution are presented. Methods: Spatial resolution of proton radiography and tomography is governed by multiple Coulomb scattering (MCS) of the protons in the patient. In this note, the authors employ Monte Carlo simulations of protons traversing a 20 cm thick water box. Entrance and exit proton coordinate measurements were simulated for improved spatial resolution. The simulations were performed with and without a 5 cm air gap in front of and behind the patient. Loss of spatial resolution due to the air gap was studied for protons with different initial angular confusion. Results: It was found that spatial resolution is significantly deteriorated when a 5 cm air gap between the position sensitive detector and the patient is included. For a perfect parallel beam spatial resolution worsens by about 40%. Spatial resolution is getting worse with increasing angular confusion and can reach 80%. Conclusions: When proton radiographies are produced by measuring the entrance and exit coordinates of the protons in front of and behind the patient the air gap between the detector and the patient can significantly deteriorate the spatial resolution of the system by up to 80%. An alternative would be to measure in addition to the coordinates also the exit and entrance angles of each proton. In principle, using the air gap size and proton angle, images can be reconstructed with the same spatial resolution than without air gap.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-441: Comparison of Dose Distributions for Spot-Scanned Pencil-Beam and Scattered-Beam Proton Treatments of Ocular Tumors

Purpose: To study the cross-field and depth dose profiles of spot-scanned pencil beam configurations for the treatment of ocular tumors and to compare their performance to a simulated scattered beam. Methods: Dose distributions in a cubic water phantom were compared for beams that passed through a final 24mm diameter aperture to deposit maximum dose at 2.4cm depth. The pencil-beam spots formed a hexagonally-packed ring with a center-to-center spacing of 4mm. The protons exited the nozzle with energy 95.5MeV, traversed a 4.5cm water-equivalent range shifter, and travelled either 42.5cm or 100cm to the phantom surface. The aperture-to-phantom distance (APD) was 5.7cm to allow room for eye-tracking hardware. A configuration with APD=0 was also tested. The scattered beam was generated with energy 159MeV, passed through 127mm of Lexan, exited the final aperture, and travelled 5.7cm to the phantom surface. This latter configuration is comparable to the MGH single scattered beamline. All beams were modelled with TOPAS1.0-beta6 compiled with GEANT4.9.6p2. Results: The modeled scattered beam produced a distal fall-off along the central axis of zd90%-zd10%=3.6mm. For the pencil beam, the zd90%-zd10% was 1.6mm in all configurations. The scattered beam's cross-field penumbra at depth of maximum dose was r90%- r10%=1.9mm. For the spot-scanned configuration with the range-shifter-tophantom distance (RsPD) of 100cm, similar cross-field profiles were achieved with r90%-r10%=2.0mm. At shorter RsPD of 42.5cm, the crossfield penumbras were 5.6mm and 7.7mm for APD=0cm and APD=5.7cm, respectively. Conclusion: For proton treatments employing a range shifter, the cross-field and central axis dose profiles depend on the quality of the original beam, the size of the range shifter, the distance from the range shifter exit to the patient, and the distance from the final aperture to the patient. A spot-scanned pencil beam configuration can achieve cross-field penumbras equal to a scattered beam and superior distal gradients.

60 APPLIED LIFE SCIENCES↗

SU-E-T-609: Evaluation of Transit Dosimetry Software Using Heterogeneous Phantom

Purpose: The purpose of this work was to evaluate limits and capabilities in the transit dosimetry software for use with the TomoTherapy system by irradiating a heterogeneous phantom. Methods: Helical TomoTherapy plan was created using CIRS phantom (model 062M) with nine various tissue equivalent inserts (lung inhale 0.2 g/cm{sup 3}, lung exhale 0.5 g/cm{sup 3}, adipose 0.96 g/cm{sup 3}, breast 0.99 g/cm{sup 3}, water 1.01 g/cm{sup 3}, muscle 1.06 g/cm{sup 3}, liver 1.07 g/cm{sup 3}, trabecular bone 1.16 g/cm{sup 3}, and dense bone 1.53 g/cm{sup 3}). Targets were contoured within every insert. The phantom was scanned with a 50 cm field of view and 3 mm slice width. Images were imported into the TomoTherapy TPS. A plan was generated to deliver 20 Gy to every insert (2 Gy per fraction) with a jaw width of 2.5 cm, a pitch of 0.430 and an actual modulation factor of 2.621. After the radiation delivery the planning CT, the RT structure, the RT plan, and the RT dose (DICOM format) as well as the exit detector sinogram were imported into the Dosimetry Check software (Math Resolutions, LLC). The 3D delivered doses were reconstructed from the exit detector data by correcting for phantom and couch attenuation. The resulting dose distribution were compared with the TPS planned dose using gamma index. Results: Using the clinical gamma criteria, 3% and 3 mm, all tissue equivalent inserts had a passing percentage of 100% except for 0.2 g/cm{sup 3} and 0.5 g/cm{sup 3} density inserts (gamma value of 81.67% and 99.18% respectively). Conclusion: The evaluated transit dosimetry software provides an independent verification of helical TomoTherapy plans giving additional confidence in the treatment delivery, however, an overestimation of the reconstructed dose in low density materials has been revealed. Implementation of Monte Carlo algorithm for exit dose reconstruction should improve dosimetric accuracy in heterogeneous patient tissues. Agreement with Math Resolutions.

60 APPLIED LIFE SCIENCES↗