Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Disassembly”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Coiled spring makes self-locking device for threaded fasteners

Coiled spring device provides both easy self-locking and disassembly for screw-threaded fasteners. When the fastener turns in one direction the spring grips one of the fastener threads and releases when the fastener turns in the opposite direction.

Source record↗

Electric arc heater is self starting

Remote method initiates an electric arc over a large range of gaps between two water-cooled electrodes of an arc-heated wind tunnel without disassembling the arc unit. This type of starting system can be used on both three-phase ac arc heaters and dc arc heaters.

Brown, R. D.↗

Hand tool permits shrink sizing of assembled tubing

Portable tool sizes tubing ends without disassembling the tubing installation. The shrink sizing tool is clamped to the tubing and operated by a ratchet wrench. A gear train forces the tubing end against an appropriate die or mandrel to effect the sizing.

Millett, A.↗

Connector acts as quick coupling in coaxial cable application

Quick-coupling connector whose inner shells are threaded to the cable ends and whose outer shells have tracks that register in channels machined in the inner shells are rotated 45 deg to effect a locking of the coupling. This connector faithfully reproduces excellent electrical characteristics no matter how frequently assembled and disassembled.

Brejcha, A. G., Jr.↗

Clamp provides efficient connection for high-density currents

Electrical connector clamp /bus bar/ gives high contact-surface efficiency for providing a high current to thin wall stainless steel tubing containing hydrogen gas. It uses lead solder film to provide the electrical equivalent of a fusion bond without degrading the grain structure, permitting disassembly and reuse of the components.

Mc Carthy, J. R.↗

Web belt load measuring instrument has excellent stability

Web belt system measures belt or strap load. It is partially disassembled and installed on an existing belt without cutting or re-threading the belt. A strain gage, installed on one of the support beams, eliminates errors due to uneven loading.

Walker, R. R.↗

Abrasion and resistant discharge valve developed

Discharge valve capable of withstanding intense radiation and high abrasion was developed for use in a fluidized bed reactor. The valve which employs a replaceable Teflon seal, has only one moving part and is designed for remote assembly and disassembly.

Gottwald, W. L.↗

Technique for in-place welding of aluminum backed up by a combustible material

Welding external aluminum jacket, tightly wrapped around inner layer of wood composition fiberboard, in oxygen free environment prevents combustion and subsequent damage to underlying fiberboard. Technique also applies to metal cutting in similar assemblies without disassembly to remove combustible materials from welding heat proximity.

Spagnuolo, A. C.↗

Liquid-fuel valve with precise throttling control

Prototype liquid-fuel valve performs on-off and throttling functions in vacuum without component cold-welding or excessive leakage. Valve design enables simple and rapid disassembly and parts replacement and operates with short working stroke, providing maximum throttling sensitivity commensurate with good control.

Mcdougal, A. R.↗

Micro regulating ball valve

Ball valve of simple, rugged configuration overcomes leakage because there are no critical wear areas. Design has stable and precise calibration. Device can be assembled or disassembled in seconds and needs no lubrication.

Hawkins, J. W.↗

Positive fast sealing union connections

Union connections are designed for connecting high pressure flexible hoses from gas storage manifolds to gas transport trailers. Connection uses O ring seals which can be quickly assembled and disassembled without use of wrenches, and which do not twist hose. Worn or damaged O rings are easily replaced.

Kleber, C. M.↗

Experimental system for the control of surgically induced infections

The results are presented of the development tests performed on the experimental system for the control of surgically induced infections. Tests were performed on the portable clean room to demonstrate assembly, collapsability, portability and storage. Collapsing, relocating and storing within the surgery room can be accomplished in 12 minutes. The storage envelope dimensions are 1.64 m x 4.24 m x 2.62 m high. The disassembly transfer to another room, and reassembly were demonstrated. The laminar air flow velocity profile within the enclosure was measured. In the undisturbed area of the enclosure the air flow met the Federal Standard 209a requirements of 27.45 meters per minute + or - 6.10 meters per minute. Smoke tests with simulated surgery equipment and personnel in the enclosure did not indicate any detrimental air flow patterns. It is concluded that the system as designed will perform the functions required for its intended use.

Source record↗

Shock and vibration tests of a SNAP-8 NaK pump

The pump used for reactor cooling in the SNAP 8 space power system was subjected to the expected vehicle launch vibration, and shock loading in accordance with the SNAP 8 environmental specification. Subsequent disassembly revealed damage to the thrust bearing pins, which should be redesigned and strengthened. The unit was operational, however, when run in a test loop after reassembly.

Stromquist, A. J.↗

Experimental system for the control of surgically induced infections, operating and maintenance instructions D203613-004

An experimental portable system used to control surgically induced infections is described. The system consists of a portable clean room comprised of a laminar flow filter system consistent with Federal standards; a helmet-shoulder pad assembly; a communication system; a helmet ventilation system; a transparent walled enclosure; and surgical gowns. Guidelines for the set up and operation of such equipment are given along with corrective steps to use in case of system malfunctions. Cleaning procedures, maintenance requirements, and disassembly and transfer particulars are included.

Tevebaugh, M. D.↗

A technique for making clean holes in metallic piping and components

Testing was conducted to develop a technique of providing clean holes in process piping or in a metal surface accessible from one side only without disassembling the system. The method was performed on sample pieces of piping and worked successfully with no contaminants being found on the inside of the pipe. The materials tested were Inconel 600, 304 stainless steel, Hastelloy X, and ASTM-A53 black steel. The technique was developed such that it could be done in the field with hand-held power tools and a portable tungsten inert gas welding machine.

Hecker, T. P.↗

Surveyor 3: Bacterium isolated from lunar retrieved television camera

Microbial analysis was the first of several studies of the retrieved camera and was performed immediately after the camera was opened. The emphasis of the analysis was placed upon isolating microorganisms that could be potentially pathogenic for man. Every step in the retrieval of the Surveyor 3 television camera was analyzed for possible contamination sources, including camera contact by the astronauts, ingassing in the lunar and command module during the mission or at splashdown, and handling during quarantine, disassembly, and analysis at the Lunar Receiving Laboratory

Mitchell, F. J.↗