Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

The Neutrino: A Better Understanding Through Astrophysics: Final Report

The final report for the award "The Neutrino: A Better Understanding Through Astrophysics" is given. The goals of the work were the following: to construct new theoretical approaches to the problem of neutrino propagation in media including where neutrino-neutrino interactions are important; to pioneer the use of new approaches, including super-scattering operators, for the evolution of neutrino thermal and statistical ensembles; to implement these new approaches in computer codes to study neutrino evolution in supernovae and other hot, dense environments; to increase the realism of simulated signals of a Galactic supernovae neutrino burst in current and future neutrino detectors; to study the simulated signals to determine the ability to extract information on the missing neutrino mixing parameters and the dynamics of the supernova explosion; and to study sterile neutrinos and non-standard interactions of neutrinos in supernovae and their effect upon the signal. Accomplishments made in these areas are described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of Beam Ion Loss from the Compact Helical System

Beam ion loss from the Compact Helical System (CHS) has been measured with a scintillator-type probe. The total loss to the probe, and the pitch angle and gyroradius distributions of that loss, have been measured as various plasma parameters were scanned. Three classes of beam ion loss were observed at the probe position: passing ions with pitch angles within 10o of those of transition orbits, ions on transition orbits, and ions on trapped orbits, typically 15o or more from transition orbits. Some orbit calculations in this geometry have been performed in order to understand the characteristics of the loss. Simulation of the detector signal based upon the following of orbits from realistic beam deposition profiles is not able to reproduce the pitch angle distribution of the losses measured. Consequently it is inferred that internal plasma processes, whether magnetohydrodynamic modes, radial electric fields, or plasma turbulence, move previously confined beam ions to transition orbits, resulting in their loss.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutrino factory for both large and small {theta}{sub 13}

An analysis of the neutrino oscillation physics capability of a low-energy neutrino factory is presented, including a first simulation of the detector efficiency and event energy threshold. The sensitivity of the physics reach to the presence of backgrounds is also studied. We consider a representative baseline of 1480 km, we use muons with 4.12 GeV energy and we exploit a very conservative estimate of the energy resolution of the detector. Our analysis suggests an impressive physics reach for this setup, which can eliminate degenerate solutions, for both large and small values of the mixing angle {theta}{sub 13}, and can determine leptonic CP violation and the neutrino mass hierarchy with extraordinary sensitivity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulations of X-Ray Telescopes for eROSITA and IXO

We report on the development of a generic X-ray instrument simulator to be used in simulations of future X-ray missions. Based on a Monte Carlo approach the code generates photon events for sources in an X-ray source catalogue such as the ROSAT all sky survey or the XMM-Newton slew surveys and then models the imaging and detection process based on the available calibration files (e.g., point spread functions for the imaging). The output of the program are event lists, which can be analysed using standard software such as xselect. Due to its modular concept the simulation software can be easily adapted to different concepts of imaging detectors.As examples for the potential use of the simulation we present our studies for eROSITA and show results of simulations of the detector performance for the High Time Resolution Spectrometer and the Wide Field Imager on the International X-ray Observatory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Primary track recovery in high-definition gas time projection chambers

Abstract We develop and validate a new algorithm called primary track recovery () that effectively deconvolves known physics and detector effects from nuclear recoil tracks in gas time projection chambers (TPCs) with high-resolution readout. This gives access to the primary track charge, length, and vector direction (helping to resolve the “head-tail” ambiguity). Additionally, provides a measurement of the transverse and longitudinal diffusion widths, which can be used to determine the absolute position of tracks in the drift direction for detector fiducialization. Using simulated helium recoils in an atmospheric pressure TPC with a 70:30 mixture of $$\hbox {He:CO}_2$$ He:CO 2 we compare the performance of to traditional methods for all key track variables. We find that the algorithm reduces reconstruction errors, including those caused by charge integration, for tracks with mean length-to-width ratios 1.4 and above, corresponding to recoil energies of 20 keV and above in the studied TPCs. We show that improves on existing methods for head-tail disambiguation, particularly for highly inclined tracks, and improves the determination of the absolute position of recoils on the drift axis via transverse diffusion. We find that can partially recover charge structure integrated out by the detector in the z direction, but that its determination of energy and length have worse resolution compared to existing methods. We use experimental data to qualitatively verify these findings and discuss implications for future directional detectors at the low-energy frontier.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optical design of Argonne/KICP detectors for CMB polarization.

We present simulations and measurements of a new optical coupling scheme for bolometric detectors for cosmic microwave background (CMB) polarization under development by Argonne National Labs and the University of Chicago. We show simulations of the performance and a tolerance analysis of this device along with measurements that validate its performance. Optical measurements of a prototype point to a 90% coupling efficiency with a cross-polarization below -20 dB.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-purity germanium semiconductor modeling in the detector response function toolkit

In this study, we have extended the detector response function toolkit (DRiFT) to provide modeling capabilities of semiconductor sensors. DRiFT provides realistic nuclear instrumentation response by post-processing Monte-Carlo N-particle (MCNP®) radiation transport outputs. MCNP® is capable of modeling radiation transport in complex environments, but has limited detector physics and readout electronics modeling capabilities. Semiconductor detector response can be calculated with a high-fidelity for a flexible range of environments by utilizing MCNP® to simulate radiation interactions inside of detector volumes, and then using DRiFT to model charge transport and signal formation in the semiconductor, as well as the readout electronics. DRiFT models charge transport in the semiconductor, the preamplifier, shaping amplifier, pulse pile-up, and electronic noise to generate detector response. The semiconductor application in DRiFT can model a range of semiconductor materials, shapes, and sizes; and is demonstrated here for a large volume coaxial high-purity germanium (HPGe) detector. Here, we compare detector response functions of a coaxial HPGe detector with measurement of 60 Co, 133 Ba, and 137 Cs at varying count rates, and we conduct a parameter study to demonstrate the effect of changing parameters in the DRiFT simulation. The HPGe detector response function shows excellent agreement with measurements of difference sources with varying dead times and count rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring and monitoring KIPT Neutron Source Facility Reactivity

Argonne National Laboratory (ANL) of USA and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have been collaborating on developing and constructing a neutron source facility at Kharkov, Ukraine. The facility consists of an accelerator-driven subcritical system. The accelerator has a 100 kW electron beam using 100 MeV electrons. The subcritical assembly has k eff less than 0.98. To ensure the safe operation of this neutron source facility, the reactivity of the subcritical core has to be accurately determined and continuously monitored. A technique which combines the area-ratio method and the flux-to-current ratio method is purposed to determine the reactivity of the KIPT subcritical assembly at various conditions. In particular, the area-ratio method can determine the absolute reactivity of the subcritical assembly in units of dollars by performing pulsed-neutron experiments. It provides reference reactivities for the flux-to-current ratio method to track and monitor the reactivity deviations from the reference state while the facility is at other operation modes. Monte Carlo simulations are performed to simulate both methods using the numerical model of the KIPT subcritical assembly. It is found that the reactivities obtained from both the area-ratio method and the flux-to-current ratio method are spatially dependent on the neutron detector locations and types. Numerical simulations also suggest optimal neutron detector locations to minimize the spatial effects in the flux-to-current ratio method. The spatial correction factors are calculated using Monte Carlo methods for both measuring methods at the selected neutron detector locations. Monte Carlo simulations are also performed to verify the accuracy of the flux-to-current ratio method in monitoring the reactivity swing during a fuel burnup cycle.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design and R&D of RICH detectors for EIC experiments

An Electron-Ion Collider (EIC) has been proposed to further explore the strong force and QCD, focusing on the structure and the interaction of gluon-dominated matter. A generic detector R& D program (EIC PID consortium) for the particle identification in EIC experiments was formed to explore technologically advanced solutions in this scope. In this context two Ring Imaging Cherenkov (RICH) counters have been proposed: a modular RICH detector which consists of an aerogel radiator, a Fresnel lens, a mirrored box, and pixelated photon sensor; a dual-radiator RICH, consisting of an aerogel radiator and C 2 F 6 gas in a mirror-focused configuration. We present the simulations of the two detectors and their estimated performance.

electron-ion collider↗

A COMPARISON OF GADRAS SIMULATED AND MEASURED GAMMA RAY SPECTRA

Gamma-ray radiation detection systems are continuously being developed and improved for detecting the presence of radioactive material and for identifying isotopes present. Gamma-ray spectra, from many different isotopes and in different types and thicknesses of attenuation material and matrixes, are needed to evaluate the performance of these devices. Recently, a test and evaluation exercise was performed by the Savannah River National Laboratory that required a large number of gamma-ray spectra. Simulated spectra were used for a major portion of the testing in order to provide a pool of data large enough for the results to be statistically significant. The test data set was comprised of two types of data, measured and simulated. The measured data were acquired with a hand-held Radioisotope Identification Device (RIID) and simulated spectra were created using Gamma Detector Response and Analysis Software (GADRAS, Mitchell and Mattingly, Sandia National Laboratory). GADRAS uses a one-dimensional discrete ordinate calculation to simulate gamma-ray spectra. The measured and simulated spectra have been analyzed and compared. This paper will discuss the results of the comparison and offer explanations for spectral differences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inclusive Search for the SM Higgs Boson in the H{yields}{gamma}{gamma} channel at the LHC

A prospective for the inclusive search of the Standard Model Higgs boson in the decay channel H{yields}{gamma}{gamma} is presented with the CMS experiment at the LHC. The analysis relies on a strategy to determine the background characteristics and systematics from data. The strategy is applied to a Monte Model of the QCD background, with full simulation of the detector response. The discrimination between signal and background exploits information on photon isolation and kinematics. The resolution for the reconstructed Higgs boson mass profits from the excellent energy resolution of the CMS crystal calorimeter. A discovery significance above 5 sigma is expected at integrated LHC luminosities below 30 fb{sup -1} for Higgs boson masses below 140 GeV/c{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

R-matrix analysis of the {sup 236}U(n,{gamma}) reaction in the resolved resonance energy region

The neutron capture cross section of {sup 236}U was measured in the neutron energy range from 1 eV to 10 keV by the neutron time-of-flight method at the GELINA white pulsed neutron source of the Institute for Reference Materials and Measurements (IRMM) in Geel (Belgium). The gamma rays originating from neutron capture events were detected by two C{sub 6}D{sub 6}-based liquid scintillators using the pulse height weighting technique. The weighting function has been derived from Monte-Carlo simulations of the detector response to monoenergetic gamma rays.The sample under investigation with a total amount of 338 mg of {sup 236}U was located in the neutron beam at a distance of 28.6 m from the source. The shape of the neutron flux was determined by a {sup 10}B neutron counter, placed approximately 60 cm upstream in the neutron beam line.The neutron capture yield in the resolved resonance region up to 1 keV has been derived from time-of-flight spectra.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

RE-EVALUATION OF THE NEUTRON EMISSION FROM THE SOLAR FLARE OF 2005 SEPTEMBER 7, DETECTED BY THE SOLAR NEUTRON TELESCOPE AT SIERRA NEGRA

The X17.0 solar flare of 2005 September 7 released high-energy neutrons that were detected by the Solar Neutron Telescope (SNT) at Sierra Negra, Mexico. In three separate and independent studies of this solar neutron event, several of its unique characteristics were studied; in particular, a power-law energy spectra was estimated. In this paper, we present an alternative analysis, based on improved numerical simulations of the detector using GEANT4, and a different technique for processing the SNT data. The results indicate that the spectral index that best fits the neutron flux is around 3, in agreement with previous works. Based on the numerically calculated neutron energy deposition on the SNT, we confirm that the detected neutrons might have reached an energy of 1 GeV, which implies that 10 GeV protons were probably produced; these could not be observed at Earth, as their parent flare was an east limb event.

79 ASTRONOMY AND ASTROPHYSICS↗

Implementing a newly proposed Monte Carlo based small field dosimetry formalism for a comprehensive set of diode detectors

Purpose: The goal of this work was to implement a recently proposed small field dosimetry formalism [Alfonso et al., Med. Phys. 35(12), 5179-5186 (2008)] for a comprehensive set of diode detectors and provide the required Monte Carlo generated factors to correct measurement. Methods: Jaw collimated square small field sizes of side 0.5, 0.6, 0.7, 0.8, 0.9, 1.0, and 3.0 cm normalized to a reference field of 5.0 cm x 5.0 cm were used throughout this study. Initial linac modeling was performed with electron source parameters at 6.0, 6.1, and 6.2 MeV with the Gaussian FWHM decreased in steps of 0.010 cm from 0.150 to 0.100 cm. DOSRZnrc was used to develop models of the IBA stereotactic field diode (SFD) as well as the PTW T60008, T60012, T60016, and T60017 field diodes. Simulations were run and isocentric, detector specific, output ratios (OR{sub det}) calculated at depths of 1.5, 5.0, and 10.0 cm. This was performed using the following source parameter subset: 6.1 and 6.2 MeV with a FWHM = 0.100, 0.110, and 0.120 cm. The source parameters were finalized by comparing experimental detector specific output ratios with simulation. Simulations were then run with the active volume and surrounding materials set to water and the replacement correction factors calculated according to the newly proposed formalism. Results: In all cases, the experimental field size widths (at the 50% level) were found to be smaller than the nominal, and therefore, the simulated field sizes were adjusted accordingly. At a FWHM = 0.150 cm simulation produced penumbral widths that were too broad. The fit improved as the FWHM was decreased, yet for all but the smallest field size worsened again at a FWHM = 0.100 cm. The simulated OR{sub det} were found to be greater than, equivalent to and less than experiment for spot size FWHM = 0.100, 0.110, and 0.120 cm, respectively. This is due to the change in source occlusion as a function of FWHM and field size. The corrections required for the 0.5 cm field size were 0.95 ({+-}1.0%) for the SFD, T60012 and T60017 diodes and 0.90 ({+-}1.0%) for the T60008 and T60016 diodes--indicating measured output ratios to be 5% and 10% high, respectively. Our results also revealed the correction factors to be the same within statistical variation at all depths considered. Conclusions: A number of general conclusions are evident: (1) small field OR{sub det} are very sensitive to the simulated source parameters, and therefore, rigorous Monte Carlo linac model commissioning, with respect to measurement, must be pursued prior to use, (2) backscattered dose to the monitor chamber should be included in simulated OR{sub det} calculations, (3) the corrections required for diode detectors are design dependent and therefore detailed detector modeling is required, and (4) the reported detector specific correction factors may be applied to experimental small field OR{sub det} consistent with those presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computed Tomography of Dry Cask Storage for Used Fuel

The demand for dry cask storage for used nuclear fuel is on the rise due to the continuous operation of currently existing nuclear plants which are reaching or have reached the capacity of their used fuel pools. Dry cask storage allows used fuel that has already been cooled in the used fuel pool for at least five years to be surrounded by an inert gas inside a specially designed and licensed cask. Currently, 75 of the 78 U.S.A reactor sites either have or are pursuing an independent spent fuel storage installation (ISFSI) for dry cask fuel storage with over 2,000 casks already loaded. Cask loading will only continue to increase until a final repository solution is operational or the U.S. begins to recycle fuel. The challenge of monitoring the condition of the used fuel inside the cask without exposing the used fuel has been apparent since the 1980's. The objective of the University of Florida (UF) project is ultimately to investigate the feasibility of imaging the used fuel assemblies' location and evaluating the inner structural condition using emission source computed tomography (CT). A combination of radiation transport models will be used to simulate gamma-rays and neutrons traversing through the used fuel, structure, and cask body materials. In the simulations, multiple linear detector arrays will record the radiation outside the cask wall and will be placed at various angles in order to model rotating a linear detector array around the entire cask. The combination of data from all the detectors will give the planar radiation projection onto the detectors, more commonly called the Radon transform, of the structure of used fuel assemblies. This project can be processed with filtered back projection or other more advanced reconstructive imaging algorithms to recreate the fuel structures. A majority of the historical work done for used fuel has been on verification, diversion detection, and burnup credit validation in order to meet regulatory guidelines. One of the more commonly used systems for single assembly verification is the Fork Detector developed at Los Alamos National Laboratory in 1988. A group at the Idaho National Laboratory developed a Compton Dry-Cask Imaging Scanner that has the ability to detect empty vs full storage positions but it suffered a setback when transported to the Doel Nuclear Power Plant near Antwerp, Belgium; the system was unable to detect full energy peaks because of the additional scattering caused by a thick ballistic steel shield. As detectors, computational power, and modeling improves, a few groups have leveraged these advancements and started to investigate CT hoping, that despite the difficulties, the technique can give information on fuel condition. So far the groups have mostly limited the tomographic work to a per assembly basis , rather than the full dry cask as the University of Florida plans to investigate. The downsides of CT versus simpler verification and validation are the amount of data required and the time it takes to acquire that data. Given that dry casks are intended to sit undistributed for up to 60 years, a scanning time of several weeks to several months is not unreasonable if such systems do not require human operators beyond the initial setup. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Neural MUSE Analysis

Researchers at Oak Ridge National Laboratory (ORNL) created data as part of the MUSE (Multi-Agency Urban Search Experiment Detector and Algorithm Test Bed) project simulating illicit nuclear materials located in various buildings along a road. In the simulation, a truck containing a radiation detector drives down the road gathering listmode data (counting the and energy of incident gamma radiation). Building materials, source shielding, driving speed, truck direction, truck location on the road, source type, and source placement are all varied between runs of the data set. This data was created using deterministic neutron transport and Monte Carlo methods through a combination of SCALE, MAVRIC, MCNP, and GADRAS. As part of a follow-on NA-22 project, two Kaggle competitions were created to determine the best algorithms for finding and identifying gamma sources in this simulated urban environment. The winning algorithm was neural network-based and had a test accuracy of 76.4% accuracy for source identification. This work seeks to build upon this work and improve the results through the application of novel machine learning techniques. As a first step, the data was classified by a simple Convolutional Neural Network (CNN) To accomplish this, the data was first preprocessed into “waterfall plots.” These plots are composed of energy vs count plots that are stacked vertically to show progression in time. The horizontal axis indicating the particle energy incorporated user defined bin spacing with options for in linear-, logarithmic-, square root-, and user-spaced bins. The z or color dimension showed the number of counts corresponding the energy-time combination. This data was then used to generate more data, by generating a local estimate of the mean of the distribution for a bin and then randomly re-sampling that bin from a Poisson distribution. Once all of this data was generated, it was fed into a well-known CNN architecture, ResNet50. The output layer of this model was removed and replaced with layers corresponding to the shape desired isotope outputs. The provided training data was used to train the classifier and the remaining testing data was used to evaluate the model. Results are soon to be forthcoming.

61 RADIATION PROTECTION AND DOSIMETRY↗

Simulation study of a 'fission electron-collection' neutron detector

In this work, a 'fission electron-collection' neutron detector was studied using the Monte Carlo method. The detector consists of two metal electrodes mounted in a vacuum, named coated and collection electrodes, respectively. The first electrode is coated with triuranium octoxide. The detector uses the 'fission electron-collection' technique, which does not need an intermediate material but directly collects electrons from the coating. Such a detector can realize a flat energy response and a fast time response, both of which are important in the fluence measurement of pulsed neutron sources. In this paper, the physical processes of detection are presented, as well as Monte Carlo simulation studies using the Geant4 toolkit. From the results, the sensitivity of the detector is approximately 1.5 x 10{sup -21} [C/(n/cm{sup 2})], and the FWHM of response function is 2.5 nanoseconds. Additionally, the characterization of escaping electrons is also presented, and the sensitivity of the detector is determined for various coating thicknesses. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗