Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector grounding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

The HEXITEC Hard X-Ray Pixelated CdTe Imager for Fast Solar Observations

There is an increasing demand in solar and astrophysics for high resolution X-ray spectroscopic imaging. Such observations would present ground breaking opportunities to study the poorly understood high energy processes in our solar system and beyond, such as solar flares, X-ray binaries, and active galactic nuclei. However, such observations require a new breed of solid state detectors sensitive to high energy X-rays with fine independent pixels to sub-sample the point spread function (PSF) of the X-ray optics. For solar observations in particular, they must also be capable of handling very high count rates as photon fluxes from solar flares often cause pile up and saturation in present generation detectors. The Rutherford Appleton Laboratory (RAL) has recently developed a new cadmium telluride (CdTe) detector system, called HEXITEC (High Energy X-ray Imaging Technology). It is an 80 x 80 array of 250 micron independent pixels sensitive in the 2-200 keV band and capable of a high full frame read out rate of 10 kHz. HEXITEC provides the smallest independently read out CdTe pixels currently available, and are well matched to the few arcsecond PSF produced by current and next generation hard X-ray focusing optics. NASA's Goddard and Marshall Space Flight Centers are collaborating with RAL to develop these detectors for use on future space borne hard X-ray focusing telescopes. We show the latest results on HEXITEC's imaging capability, energy resolution, high read out rate, and reveal it to be ideal for such future instruments.

Baumgartner, Wayne H.↗

Bolometric Array Detectors for Space-Borne Astronomy

Funding from the NASA Innovative Research Grant was used to develop bolometric detectors. As described in the proposal, silicon nitride micromesh ('spider-web') absorbers had been demonstrated at U.C. Berkeley but not developed to be flight-worthy devices. We proceeded to first fabricate bolometers with Neutron Transmutation Doped (NTD) Ge thermistors that demonstrated high optical coupling (Church et al. 1996) and were developed for a ground-based millimeter-wave receiver (Mauskopf et al. 1997). The next generation of devices used In bump-bonded thermistors to achieve devices with performance product NEP*sqrt(tau) = 3e - 18 j at 300 mK, demonstrating a full order of magnitude improvement over pervious devices. These devices achieved an NEP = 1e-18 W/rtHz (Murray et al. 1996) as promised in the proposal. Sensitivities as good as 1e - 19 W/rtHz appear achievable with the silicon nitride architecture (Bock et al. 1997). Finally, arrays of micromesh bolometers were shown to be feasible in the last year of the program by etching a large number of devices on a single silicon wafer (75 mm). Full arrays were subsequently demonstrated for selection on the ESA/NASA Far-Infrared Space Telescope (FIRST) in competition with detectors provided by CEA in France and GSFC in the US Micromesh bolometer arrays are now baselined for both the ESA/NASA Planck and FIRST missions.

Lange, Andrew E.↗

Solid-State 2-Micron Laser Transmitter Advancement for Wind and Carbon Dioxide Measurements From Ground, Airborne, and Space-Based Lidar Systems

NASA Langley Research Center has been developing 2-micron lidar technologies over a decade for wind measurements, utilizing coherent Doppler wind lidar technique and carbon dioxide measurements, utilizing Differential Absorption Lidar (DIAL) technique. Significant advancements have been made towards developing state-of-the-art technologies towards laser transmitters, detectors, and receiver systems. These efforts have led to the development of solid-state lasers with high pulse energy, tunablility, wavelength-stability, and double-pulsed operation. This paper will present a review of these technological developments along with examples of high resolution wind and high precision CO2 DIAL measurements in the atmosphere. Plans for the development of compact high power lasers for applications in airborne and future space platforms for wind and regional to global scale measurement of atmospheric CO2 will also be discussed.

Singh, Upendra N.↗

A rocket ozonesonde for geophysical research and satellite intercomparison

The in-situ rocketsonde for ozone profile measurements developed and flown for geophysical research and satellite comparison is reviewed. The measurement principle involves the chemiluminescence caused by ambient ozone striking a detector and passive pumping as a means of sampling the atmosphere as the sonde descends through the atmosphere on a parachute. The sonde is flown on a meteorological sounding rocket, and flight data are telemetered via the standard meteorological GMD ground receiving system. The payload operation, sensor performance, and calibration procedures simulating flight conditions are described. An error analysis indicated an absolute accuracy of about 12 percent and a precision of about 8 percent. These are combined to give a measurement error of 14 percent.

Hilsenrath, E.↗

Cross-Sensor Validation of the Optical Transient Detector (OTD)

Lightning data from the U.S. National Lightning Detection Network (NLDN) is used to perform preliminary validation of the satellite-based Optical Transient Detector (OTD). Sensor precision, accuracy, detection efficiency and biases of the deployed instrument are considered. We estimate the sensor to have, on average, better than 30 km spatial and 100 ms temporal accuracy. The detection efficiency for cloud-to-ground lightning is about 45-70%, slightly higher for intracloud lightning. There are only marginal day/night biases in the dataset, although 55 day averaging is required to remove sampling-based diurnal lightning cycle biases. The sensor detects statistically significant differences in the optical characteristics of intracloud, negative cloud-to-ground and positive cloud-to-ground lightning, although it cannot a priori determine flash types.

Boccippio, D. J.↗

Lightning Activity within a Tornadic Thunderstorm Observed by the Optical Transient Detector (OTD)

The first storm-scale, total lightning observations during tornadogenesis from space are presented. The NASA (National Aeronautics and Space Administration) OTD (Optical Transient Detector) overpass of an Oklahoma supercell, just minutes prior to tornado touchdown on 17 April 1995, detected a lightning flash rate of 45 flashes/ min. The total lighting activity was at least 15 times greater than the cloud-to-ground lightning activity detected by the National Lightning Detection Network (NLDN), indicating most of the lightning was intracloud. Total lightning rates were decreasing rapidly prior to tornadic touchdown. These observations are consistent with the limited results from recent ground based measurements of total lightning activity in tornadic storms, suggesting significant intracloud lightning and rapidly decreasing flash rates prior to tornado touchdown.

Buechler, D. E.↗

Numerical Filtering of Spurious Transients in a Satellite Scanning Radiometer: Application to CERES

The Clouds and Earth Radiant Energy System (CERES) scanning, radiometer was designed to provide high accuracy measurements of the radiances from the earth. Calibration testing of the instruments showed the presence of all undesired slow transient in the measurements of all channels at 1% to 2% of the signal. Analysis of the data showed that the transient consists of a single linear mode. The characteristic time of this mode is 0.3 to 0.4 s and is much greater than that the 8-10-ms response time of the detector, so that it is well separated from the detector response. A numerical filter was designed for the removal of this transient from the measurements. Results show no trace remaining of the transient after application of the numerical filter. The characterization of the slow mode on the basis of ground calibration data is discussed and flight results are shown for the CERES instruments aboard the Tropical Rainfall Measurement Mission and Terra spacecraft. The primary influence of the slow mode is in the calibration of the instrument and the in-flight validation of the calibration. This method may be applicable to other radiometers that are striving for high accuracy and encounter a slow spurious mode regardless of the underlying physics.

Smith, G. Louis↗

Verification of Dosimetry Measurements with Timepix Pixel Detectors for Space Applications

The current capabilities of modern pixel-detector technology has provided the possibility to design a new generation of radiation monitors. Timepix detectors are semiconductor pixel detectors based on a hybrid configuration. As such, the read-out chip can be used with different types and thicknesses of sensors. For space radiation dosimetry applications, Timepix devices with 300 and 500 microns thick silicon sensors have been used by a collaboration between NASA and University of Houston to explore their performance. For that purpose, an extensive evaluation of the response of Timepix for such applications has been performed. Timepix-based devices were tested in many different environments both at ground-based accelerator facilities such as HIMAC (Heavy Ion Medical Accelerator in Chiba, Japan), and at NSRL (NASA Space Radiation Laboratory at Brookhaven National Laboratory in Upton, NY), as well as in space on board of the International Space Station (ISS). These tests have included a wide range of the particle types and energies, from protons through iron nuclei. The results have been compared both with other devices and theoretical values. This effort has demonstrated that Timepix-based detectors are exceptionally capable at providing accurate dosimetry measurements in this application as verified by the confirming correspondence with the other accepted techniques.

Kroupa, M.↗

Long-period cosmic ray variations and their altitude dependence

Long-period variations were studied from the data of ground-based cosmic ray (CR) observations. In spite of a large value of an 2-year variation, it is more difficult to obtain its spectrum than the spectrum of a solar diurnal variation. Serious obstacles are caused by changes in individual detectors and in the whole world wide network of CR detectors, by the absence of continuity and uniformity of data series, by various apparatus variations. In discrimination and investigation of long-period variations an important and determining point is preparation and preliminary analysis of data.

Belov, A. V.↗

Surface texture characterization by angular distributions of scattered light

Work at the National Bureau of Standards to develop an on-line optical measurement device and attendant algorithms for automated optical scattering measurements of machined metal surfaces are described. The surfaces could be milled, ground or lapped, and the system is intended to categorize the resulting surface characteristics. The optical device consists of a He-Ne laser which is shone on a surface. The scattered light is captured by a semicircular array of 87 detector elements rotated over the scanned area. The light signals are processed through a digital voltmeter and then an A/D converter. The signals are then stored for later comparisons with optical scattering data obtained by optical instruments used with stylus instruments for characterizing surface topographies. A theoretical model has been defined which relates light scattering and the characteristics of the surface roughness. Initial experimental results with a sinusoidal surface have indicated that although the system can follow the trend of the roughness, the roughness amplitude is as yet uncertainly defined and the computations require excessive time.

Gilsinn, D. E.↗

Cockpit display of hazardous wind shear information

Information on cockpit display of wind shear information is given in viewgraph form. Based on the current status of windshear sensors and candidate data dissemination systems, the near-term capabilities for windshear avoidance will most likely include: (1) Ground-based detection: TDWR (Terminal Doppler Weather Radar), LLWAS (Low-Level Windshear Alert System), Automated PIREPS; (2) Ground-Air datalinks: Air traffic control voice channels, Mode-S digital datalink, ACARS alphanumeric datalink. The possible datapaths for integration of these systems are illustrated in a diagram. In the future, airborne windshear detection systems such as lidars, passive IR detectors, or airborne Doppler radars may also become available. Possible future datalinks include satellite downlink and specialized en route weather channels.

Wanke, Craig↗

TEM Study of Precipitation in a NiAl-3Ti-0.5Hf Single-Crystal Alloy

Samples for transmission electron microscopy (TEM) were prepared from 3 mm diameter cylinders electro-discharge machined from the heat-treated ingots. Slices sectioned from the cylinders were mechanically ground and electrochemically thinned in a twinjet Tenupol-3 polisher. Microstructural and energy-dispersive X-ray spectroscopy (EDXS) studies were conducted in a Philips 400T TEM equipped with a double tilt goniometer and a KEVEX Si/Li X-ray detector.

Garg, A.↗

The Nuclear Spectroscopic Telescope Array (NuSTAR)

The Nuclear Spectroscopic Telescope Array (NuSTAR) is a NASA Small Explorer mission that will carry the first focusing hard X-ray (5 - 80 keV) telescope to orbit. NuSTAR will offer a factor 50 - 100 sensitivity improvement compared to previous collimated or coded mask imagers that have operated in this energy band. In addition, NuSTAR provides sub-arcminute imaging with good spectral resolution over a 12-arcminute field of view. After launch, NuSTAR will carry out a two-year primary science mission that focuses on four key programs: studying the evolution of massive black holes through surveys carried out in fields with excellent multiwavelength coverage, understanding the population of compact objects and the nature of the massive black hole in the center of the Milky Way, constraining explosion dynamics and nucleosynthesis in supernovae, and probing the nature of particle acceleration in relativistic jets in active galactic nuclei. A number of additional observations will be included in the primary mission, and a. guest observer program will be proposed for an extended mission to expand the range of scientific targets. The payload consists of two co-aligned depth-graded multilayer coated grazing incidence optics focused onto solid state CdZnTe pixel detectors. To be launched in early 2012 on a Pegasus rocket into a low-inclination Earth orbit. NuSTAR largely avoids SAA passages, and will therefore have low and stable detector backgrounds. The telescope achieves a 10.15-meter focal length through on-orbit deployment of all mast. An aspect and alignment metrology system enable reconstruction of the absolute aspect and variations in the telescope alignment resulting from mast flexure during ground data processing. Data will be publicly available at GSFC's High Energy Astrophysics Science Archive Research Center (HEASARC) following validation at the science operations center located at Caltech.

Harrison, Fiona A.↗

Monocular Ranging for Small Unmanned Aerial Systems in the Far-Field

Recent proliferation of small Unmanned Aerial Systems (sUAS) applications requires onboard collision avoidance systems to mitigate the risk of collision with non-cooperative aircraft and manned aircraft, which may not see sUAS in time to perform an avoidance maneuver. An attractive avenue for onboard collision avoidance is the utilization of machine vision cameras due to their low size, weight and power (SWaP) requirements. In this paper, we characterize the range performance of a machine vision system developed in-house and mounted onto an sUAS. The technique was designed to estimate the performance of a sense-and-avoid system to ensure that the sensing components meet the well-clear requirements for the chosen platform and avoidance strategy. Experimental flight-test data was acquired from test-flights flown along multiple collision geometries for two intruders: a general Aviation (GA) aircraft and a fixed-wing sUAS. The ownship and both intruders were instrumented with inertial navigation systems (INS) recording position and attitude information. The range at first detection, 𝑹𝟎, was extracted from in-flight imagery of head-on collision course geometry synchronized with INS data from both aircraft and ground-truth values extracted from the raw imagery. This initial detection distance, 𝑹𝟎, scales with atmospheric attenuation. Therefore, under clear sky conditions, the derived 𝑹𝟎 value represents the upper bound on the detection range achievable by the test configuration of the detector. Results indicate that the maximum initial detection distance for a 4k resolution action camera fitted with a 41º Field of View (FOV) lens is 2.763 ± 0.037 km for a GA aircraft and 0.881 ± 0.061 km for a fixed-wing sUAS, respectively. The in results this study suggest that a vision-based detect and track system may be analyzed using the sensor characterization and contextualized within aircraft well-clear volumes.

Chester V. Dolph↗

New Generation Lidar Technology and Applications

Lidar has been a tool for atmospheric research for several decades. Until recently routine operational use of lidar was not known. Problems have involved a lack of appropriate technology rather than a lack of applications. Within the last few years, lidar based on a new generation of solid state lasers and detectors have changed the situation. Operational applications for cloud and aerosol research applications are now well established. In these research applications, the direct height profiling capability of lidar is typically an adjunct to other types of sensing, both passive and active. Compact eye safe lidar with the sensitivity for ground based monitoring of all significant cloud and aerosol structure and the reliability to operate full time for several years is now in routine use. The approach is known as micro pulse lidar (MPL). For MPL the laser pulse repetition rate is in the kilohertz range and the pulse energies are in the micro-Joule range. The low pulse energy permits the systems to be eye safe and reliable with solid state lasers. A number of MPL systems have been deployed since 1992 at atmospheric research sites at a variety of global locations. Accurate monitoring of cloud and aerosol vertical distribution is a critical measurement for atmospheric radiation. An airborne application of lidar cloud and aerosol profiling is retrievals of parameters from combined lidar and passive sensing involving visible, infrared and microwave frequencies. A lidar based on a large pulse, solid state diode pumped ND:YAG laser has been deployed on the NASA ER-2 high altitude research aircraft along with multi-spectral visible/IR and microwave imaging radiometers since 1993. The system has shown high reliability in an extensive series of experimental projects for cloud remote sensing. The retrieval of cirrus radiation parameters is an effective application for combined lidar and passive sensing. An approved NASA mission will soon begin long term lidar observation of atmospheric structure from space. The Geoscience Laser Altimeter System (GLAS) of the Earth Observing System is scheduled for deployment in the 2001 time frame. GLAS is both a cloud and aerosol lidar and a surface altimeter, principally for monitoring of polar ice sheets. The GLAS instrument is based on all solid state lasers operating at 40 Hz and high efficiency, solid state detectors. The design lifetime is three to five years. Data from the GLAS mission is expected to revolutionize some aspects of our understanding of the global distribution of cloud and aerosols for global climate prediction.

Spinhirne, James D.↗

Multispectral atmospheric mapping sensor of mesoscale water vapor features

The Multispectral atmospheric mapping sensor was checked out for specified spectral response and detector noise performance in the eight visible and three infrared (6.7, 11.2, 12.7 micron) spectral bands. A calibration algorithm was implemented for the infrared detectors. Engineering checkout flights on board the ER-2 produced imagery at 50 m resolution in which water vapor features in the 6.7 micron spectral band are most striking. These images were analyzed on the Man computer Interactive Data Access System (McIDAS). Ground truth and ancillary data was accessed to verify the calibration.

Menzel, P.↗

Photon statistical limitations for daytime optical tracking

Tracking of interplanetary spacecraft equipped with optical communication systems by using astrometric instruments is being investigated by JPL. Existing instruments are designed to work at night and, for bright sources, are limited by tropospheric errors. To provide full coverage of the solar system, astrometric tracking instruments must either be capable of daytime operation or be space-based. The integration times necessary for the ground-based daytime photon statistical errors to reach a given accuracy level (5 to 50 nanoradians) were computed for an ideal astrometric instrument. The required photon statistical integration times are found to be shorter than the tropospheric integrations times for the ideal detector. Since the astrometric need not be limited by photon statistics even under daytime conditions, it may be fruitful to investigate instruments for daytime optical tracking.

Folkner, W. M.↗

SWIFT BAT Loop Heat Pipe Thermal System Characteristics and Ground/Flight Operation Procedure

The SWIFT Burst Alert Telescope (BAT) Detector Array has a total power dissipation of 208 W. To meet the stringent temperature gradient and thermal stability requirements in the normal operational mode, and heater power budget in both the normal operational and safehold modes, the Detector Array is thermally well coupled to eight constant conductance heat pipes (CCHPs) embedded in the Detector Array Plate (DAP), and two loop heat pipes (LHPs) transport heat fiom the CCHPs to a radiator. The CCHPs have ammonia as the working fluid and the LHPs have propylene as the working fluid. Precision heater controllers, which have adjustable set points in flight, are used to control the LHP compensation chamber and Detector Array XA1 ASIC temperatures. The radiator has the AZ-Tek AZW-LA-II low-alpha white paint as the thermal coating and is located on the anti-sun side of the spacecraft. This paper presents the characteristics, ground operation and flight operation procedures of the LHP thermal system.

Choi, Michael K.↗