Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Response of a high-pressure 4 He scintillation detector to nuclear recoils up to 9 MeV

Helium-4-based scintillation detector technology is emerging as a strong alternative to pulse-shape discrimination-capable organic scintillators for fast neutron detection and spectroscopy, particularly in extreme gamma-ray environments. The 4 He detector is intrinsically insensitive to gamma radiation, as it has a relatively low cross-section for gamma-ray interactions, and the stopping power of electrons in the 4 He medium is low compared to that of 4 He recoil nuclei. Consequently, gamma rays can be discriminated by simple energy deposition thresholding instead of the more complex pulse shape analysis. The energy resolution of 4 He scintillation detectors has not yet been well-characterized over a broad range of energy depositions, which limits the ability to deconvolve the source spectra. In this work, an experiment was performed to characterize the response of an Arktis S670 4 He detector to nuclear recoils up to 9 MeV. The 4 He detector was positioned in the center of a semicircular array of organic scintillation detectors operated in coincidence. Deuterium–deuterium and deuterium–tritium neutron generators provided monoenergetic neutrons, yielding geometrically constrained nuclear recoils ranging from 0.0925 to 8.87 MeV. The detector response provides evidence for scintillation linearity beyond the previously reported energy range. Finally, the measured response was used to develop an energy resolution function applicable to this energy range for use in high-fidelity detector simulations needed by future applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced readout methods for superheated emulsion detectors

Superheated emulsions develop visible vapor bubbles when exposed to ionizing radiation. They consist in droplets of a metastable liquid, emulsified in an inert matrix. The formation of a bubble cavity is accompanied by sound waves. Evaporated bubbles also exhibit a lower refractive index, compared to the inert gel matrix. These two physical phenomena have been exploited to count the number of evaporated bubbles and thus measure the interacting radiation flux. Systems based on piezoelectric transducers have been traditionally used to acquire the acoustic (pressure) signals generated by bubble evaporation. Such systems can operate at ambient noise levels exceeding 100 dB; however, they are affected by a significant dead time (>10 ms). An optical readout technique relying on the scattering of light by neutron-induced bubbles has been recently improved in order to minimize measurement dead time and ambient noise sensitivity. Beams of infra-red light from light-emitting diode (LED) sources cross the active area of the detector and are deflected by evaporated bubbles. The scattered light correlates with bubble density. Planar photodiodes are affixed along the detector length in optimized positions, allowing the detection of scattered light from the bubbles and minimizing the detection of direct light from the LEDs. A low-noise signal-conditioning stage has been designed and realized to amplify the current induced in the photodiodes by scattered light and to subtract the background signal due to intrinsic scattering within the detector matrix. The proposed amplification architecture maximizes the measurement signal-to-noise ratio, yielding a readout uncertainty of 6% (±1 SD), with 1000 evaporated bubbles in a detector active volume of 150 ml (6 cm detector diameter). In this work, we prove that the intensity of scattered light also relates to the bubble size, which can be controlled by applying an external pressure to the detector emulsion. This effect can be exploited during the readout procedure to minimize shadowing effects between bubbles, which become severe when the latter are several thousands. The detector we used in this work is based on superheated C-318 (octafluorocyclobutane), emulsified in 100 μm ± 10% (1 SD) diameter drops in an inert matrix of approximately 150 ml. The detector was operated at room temperature and ambient pressure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The construction of the phase-1 upgrade of the CMS pixel detector

The innermost layers of the original CMS tracker were built out of pixel detectors arranged in three barrel layers and two forward disks in each endcap. The original CMS detector was designed for the nominal instantaneous LHC luminosity of 1×10 34 cm -2 s -1 . Under the conditions expected in the coming years, which will see an increase of a factor two of the instantaneous luminosity, the CMS pixel detector would have seen a dynamic inefficiency caused by data losses due to buffer overflows. For this reason the CMS collaboration has installed a replacement pixel detector during the recent extended end of year shutdown. The phase-1 upgrade of the CMS pixel detector will operate at high efficiency at an instantaneous luminosity of 2×10 34 cm -2 s -1 with increased detector acceptance and additional redundancy for the tracking, while at the same time reducing the material budget. These goals are achieved using a new read-out chip and modified powering and read-out schemes, one additional tracking layer both in the barrel and in the disks, and new detector supports including a CO 2 based evaporative cooling system, that contribute to the reduction of the material in the tracking volume. This contribution will review the design and technological choices of the phase-1 detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MeV-scale performance of water-based and pure liquid scintillator detectors

This paper presents studies of the performance of water-based liquid scintillators (WbLS) in both 1-kt and 50-kt detectors. In this work, performance is evaluated in comparison to both pure water Cherenkov detectors and a nominal model for pure scintillator detectors. Performance metrics include energy, vertex, and angular resolution, along with a metric for the ability to separate the Cherenkov from the scintillation signal as being representative of various particle identification capabilities that depend on the Cherenkov/scintillation ratio. We also modify the time profile of scintillation light to study the same performance metrics as a function of rise and decay time. We go on to interpret these results in terms of their impact on certain physics goals, such as solar neutrinos and the search for Majorana neutrinos. This work supports and validates previous results, and the assumptions made therein, and serves as a significant stepping stone to complete detector design studies by using a more detailed detector model and full reconstruction, with a primarily data-driven optical model, and fewer model assumptions. With this model, a high-coverage 50-kt detector achieves better than 10 (1)% precision on the flux of neutrinos from the Carbon-Nitrogen-Oxygen cycle with a water-based liquid scintillator (pure LS) target in five years of data taking. A 1-kt LS detector, with a conservative 50% fiducial volume of 0.5 kt, can achieve better than 5% detection. A liquid scintillator detector has sensitivity into the normal hierarchy region for Majorana neutrinos with half-life sensitivity of $T^{0νββ}_{1/2}$ > 1.4 × 10 28 years at 90% C.L. for 10 years of data taking with a Te-loaded target.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-F-T-561: Energy Dependence of a Scintillation Detector

Purpose: To investigate the response and dose rate dependence of a scintillation detector over a wide energy range. Methods: The energy dependence of W1 scintillation detector was tested with: 1) 50–225 keV beams generated by an animal irradiator, 2) a Leksell Gamma Knife Perfexion Co-60 source, 3) 6MV, 6FFF, 10FFF and 15MV photon beams, and 4) 6–20MeV electron beams from a linac. Calibrated linac beams were used to deliver 100 cGy to the detector at dmax in water under reference conditions. The gamma-knife measurement was performed in solid water (100 cGy with 16mm collimator). The low energy beams were calibrated with an ion chamber in air (TG-61), and the scintillation detector was placed at the same location as the ionization chamber during calibration. For the linac photon and electron beams, dose rate dependence was tested for 100–2400 and 100–800 MU/min. Results: The scintillation detector demonstrated strong energy dependence in the range of 50–225keV. The measured values were lower than the delivered dose and increased as the energy increased. Therapeutic photon beams showed energy independence with variations less than 1%. Therapeutic electron beams displayed the same sensitivity of ∼2–3% at their corresponding dmax depths. The change in dose-rate of photon and electron beams within the therapeutic energy range did not affect detector output (<0.5%). Measurements acquired with the gamma knife showed that the output data agreed with the delivered dose up to 3%. Conclusion: W1 scintillation detector output has a strong energy dependence in the diagnostic and orthovoltage energy range. Therapeutic photon beams exhibited energy independence with no observable dose-rate dependence. This study may aid in the implementation of a scintillation detector in QA programs by providing energy calibration factors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-CD-207B-05: Measurement of CT Bow-Tie Profiles Using a Linear Array Detector

Purpose: To accurately measure CT bow-tie profiles from various manufacturers and to provide non-proprietary information for CT system modeling. Methods: A GOS-based linear detector (0.8 mm per pixel and 51.2 cm in length) with a fast data sampling speed (0.24 ms/sample) was used to measure the relative profiles of bow-tie filters from a collection of eight CT scanners by three different vendors, GE (LS Xtra, LS VCT, Discovery HD750), Siemens (Sensation 64, Edge, Flash, Force), and Philips (iBrilliance 256). The linear detector was first calibrated for its energy response within typical CT beam quality ranges and compared with an ion chamber and analytical modeling (SPECTRA and TASMIP). A geometrical calibration process was developed to determine key parameters including the distance from the focal spot to the linear detector, the angular increment of the gantry at each data sampling, the location of the central x-ray on the linear detector, and the angular response of the detector pixel. Measurements were performed under axial-scan modes for most representative bow-tie filters and kV selections from each scanner. Bow-tie profiles were determined by re-binning the measured rotational data with an angular accuracy of 0.1 degree using the calibrated geometrical parameters. Results: The linear detector demonstrated an energy response as a solid state detector, which is close to the CT imaging detector. The geometrical calibration was proven to be sufficiently accurate (< 1mm in error for distances >550 mm) and the bow-tie profiles measured from rotational mode matched closely to those from the gantry-stationary mode. Accurate profiles were determined for a total of 21 bow-tie filters and 83 filter/kV combinations from the abovementioned scanner models. Conclusion: A new improved approach of CT bow-tie measurement was proposed and accurate bow-tie profiles were provided for a broad list of CT scanner models.

60 APPLIED LIFE SCIENCES↗

Characterization of a spectroscopic detector for application in x-ray computed tomography

Recent advances in cadmium telluride (CdTe) energy-discriminating pixelated detectors have enabled the possibility of Multi-Spectral X-ray Computed Tomography (MSXCT) to incorporate spectroscopic information into CT. MultiX ME 100 V2 is a CdTe-based spectroscopic x-ray detector array capable of recording energies from 20 to 160 keV in 1.1 keV energy bin increments. Hardware and software have been designed to perform radiographic and computed tomography tasks with this spectroscopic detector. Energy calibration is examined using the end-point energy of a bremsstrahlung spectrum and radioisotope spectral lines. When measuring the spectrum from Am-241 across 500 detector elements, the standard deviation of the peak-location and FWHM measurements are ±0.4 and ±0.6 keV, respectively. As these values are within the energy bin size (1.1 keV), detector elements are consistent with each other. The count rate is characterized, using a nonparalyzable model with a dead time of 64 ± 5 ns. This is consistent with the manufacturer’s quoted per detector-element linear-deviation at 2 Mpps (million photons per sec) of 8.9% (typical) and 12% (max). When comparing measured and simulated spectra, a low-energy tail is visible in the measured data due to the spectral response of the detector. If no valid photon detections are expected in the low-energy tail, then a background subtraction may be applied to allow for a possible first-order correction. If photons are expected in the low-energy tail, a detailed model must be implemented. A radiograph of an aluminum step wedge with a maximum height of about 20 mm shows an underestimation of attenuation by about 10% at 60 keV. This error is due to partial energy deposition from higher-energy (> 60 keV) photons into a lower-energy (~60 keV) bin, reducing the apparent attenuation. A radiograph of a PTFE cylinder taken using a bremsstrahlung spectrum from an x-ray voltage of 100 kV filtered by 1.3 mm Cu is reconstructed using Abel inversion. As no counts are expected in the low energy tail, a first order background correction is applied to the spectrum. The measured linear attenuation coefficient (LAC) is within 10% of the expected value in the 60 to 100 keV range. Below 60 keV, low counts in the corrected spectrum and partial energy deposition from incident photons of energy greater than 60 keV into energy bins below 60 keV impact the LAC measurements. This report ends with a demonstration of the tomographic capability of the system. The quantitative understanding of the detector developed in this report will enable further study in evaluating the system for characterization of an object’s chemical make-up for industrial and security purposes.

36 MATERIALS SCIENCE↗

Cryogenic Detector Development for SuperCDMS

The dark matter (DM) problem is currently one of the most pressing issues facing physics. This thesis presents some of my work and contributions to the detectors employed by the Super Cryogenic Dark Matter Search (SuperCDMS), one of the many experiments currently investigating DM. First, we present an overview of astrophysical and cosmological observations to give insight into our current understanding of DM and its role in the universe. Some potential particle DM candidates are also discussed. Then we describe the SuperCDMS experiment and relevant detector technologies. We go into particular detail in discussing the phonon sensors, deriving the relationships that define their fundamental working principles and describing their practical deployment. We also discuss the main noise contributions to the phonon sensors which can limit experimental sensitivity. We then present some work related to reconstruction of event position in the detectors, including new analysis techniques and a n ovel cryogenic calibration source mover we have developed and tested. We also present tests of improving experimental scalability by increasing individual detector masses using the largest-diameter cryogenic Si detectors yet operated. We present first experimental results from the novel use of $(n,\gamma)$ processes to calibrate the low energy nuclear recoil energy scale. This work is essential to understand how DM-nuclear interactions will manifest in semiconductor detectors. We also take a short look at the newest, most sensitive detectors currently operated by SuperCDMS and discuss how they are allowing new insights into critical physics processes in all SuperCDMS detectors. Finally, we demonstrate how some of the various improvements discussed in this work can improve the experimental reach of the next generation of SuperCDMS at SNOLAB.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Designing the Neutron Detector for the NEXUS Test Facility

The SuperCDMS dark matter experiment is commissioning a new test facility at Fermilab, NEXUS, capable of testing a new suite of detectors that promise to push to lower dark matter masses than has previously been achieved. These detectors use silicon and germanium, cooled to tens of mK, to measure small vibrations in the crystal lattice caused by very tiny energy deposits. A core capability of NEXUS test facility is to use a commercial neutron generator, coupled to an array of detectors behind the test facility, to calibrate the nuclear recoil energy scale of these detectors through neutron scattering. The response of silicon and germanium to nuclear recoils below 1 keV energy transfer is largely unknown. For dark matter models which are primarily interacting with the nucleus, calibration of this response will completely determine the dark matter sensitivity of the experiment. In this context, the proper design of the neutron tagging detector to be used in the test facility needs to be found. This work will include simulation of the detector behavior and work towards an optimization of the detector geometry based on measurement resolution and detection rate. In addition, prototype scintillators and photodetectors will be studied as candidate detector elements.

47 OTHER INSTRUMENTATION↗

Modeling the Ex-core Detector Response into a Production Option in MPACT

In the past few years, the Consortium for Advanced Simulation of Light Water Reactors (CASL) has overseen a successful activity to extend the radiation transport capability from the reactor in-core geometry to the ex-core geometry by coupling the deterministic neutronics code MPACT, with the Monte Carlo code Shift. However, transient problems such as RIAs require an efficient prediction of the ex-core detector response to determine the timeframe for a reactor trip. Therefore, in addition to the high-fidelity MPACT-Shift coupled calculation, separate efforts have been made to explore simplified methods for ex-core detector response with MPACT standalone calculation. In a previous milestone L3_RTM.MCH.P17.06, several simplified methods for ex-core detector response were developed in MPACT. In particular, the double kernel method is based on the default MPACT core geometry, so extensive modeling or transport calculation with full reflector and ex-core details are not needed in this method. Since the 1-D diffusion and neutron streaming kernels are used for extended ex-core calculations, the extra computational efforts are very small. The work implemented in the current milestone provides a fully integrated option for MPACT to approximately calculate the ex-core detector response using the double kernel method. To overcome the difficulty of obtaining the consistent diffusion coefficients (these were obtained through separate CMFD calculation and edits), the 1-D diffusion solver is replaced by a 1-D Sn transport solver to compute the neutron flux at the vessel outer surface. The new VERA inputs for ex-core detector are processed in MPACT. The detector signals are linked to the SCRAM logic as an option to trip the core during transient calculation. Two sets of 3-D quarter core problems are run with MPACT standalone and VeraShift to verify the radial and axial effects on detector response by varying the moderator density and control rod position. For the cases with moderator density changes, the detector responses from MPACT are within 2 sigma error of VeraShift. For the cases at different control rod positions, the axial offsets computed from MPACT are within 2% error of VeraShift results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Near Detector Selection for Neutral Current Disappearance Search at the Short-Baseline Neutrino Program

Various short baseline neutrino experiments observe anomalies that challenge the three-flavor neutrino oscillation model, consistent with a hypothetical “sterile” neutrino that does not interact via the weak force. This poster presents a near detector event selection at the Short-Baseline Near Detector (SBND), developed for the first search for neutral current (NC) disappearance at short-baseline experiments. NC disappearance provides ``smoking gun” insight into the sterile neutrino question because NC interactions are equally sensitive to all three active neutrinos, meaning any change in the NC interaction rate between near and far detectors cannot be explained by oscillations among known flavor states. This analysis focuses on the NC1p topology, the most common NC interaction type at the Short-Baseline Neutrino (SBN) Program. NC topologies are inherently challenging due to their low light yield and the absence of an outgoing charged lepton, which complicates identification and leads to poor energy reconstruction as the outgoing neutrino carries away a large portion of the neutrino’s initial energy. This work presents an NC1p event selection at the near detector, highlighting SBND’s impressive detector capabilities, including trigger efficiency studies. Combined with a novel kinematic energy reconstruction technique leveraging the detector’s outstanding hadronic detail, this analysis establishes a robust near detector foundation to target an NC disappearance measurement consistent with the 3$+$1 sterile neutrino model. This SBND selection will soon be combined with the far detector to conduct an NC disappearance search, providing unique insight and complementary information to traditional charged current searches and advancing the SBN Program’s goal to resolve the sterile neutrino question, including 3$+$1 searches and beyond.

Nicole Pallat, Nicole Pallat [Minnesota U.] (ORCID↗

A bismuth germanate-shielded mercuric iodide X-ray detector for space applications

The development of HgI2 for solid state X-ray detector applications over the past decade was carried out in connection with the ability of the crystal to operate as a detector at room temperature. In order to achieve the lowest background possible for HgI2 detectors in a space-like environment (balloon and/or satellite altitudes), attention was given to the design of a shielding system which actively vetoes nonaperture events such as gamma rays and charged particles that can mimic signal X-rays by partial deposition of energy in the main detector. The detector system consists of two HgI2 detectors mounted back to back and operated in anticoincidence. The two detectors are placed inside a bismuth germanate scintillating shield along with two hybrid charge-sensitive preamps. Monte Carlo simulations of detector performance are discussed.

Vallerga, J. V.↗

ISO/LWS: Detector status

The aim of the long wavelength spectrometer (LWS) of the Infrared Space Observatory is to perform spectrometry in the wavelength range 45 to 200 microns using two resolution modes. The resolution will be around 200 in the medium resolution mode while it will reach 10(exp 4) in the high resolution mode. The sensitivity of this instrument will be close to 10(exp -18) W/sq. root Hz. A schematic view of the focal plane unit is presented. The detectors divide the wavelength range into ten spectral channels. The spectral range and position of each detector is indicated. Each detector will cover approximately a spectral bandwidth sufficient to allow for a 50 percent redundancy in the case of detector failure. There are three types of detectors. SW1 is a Ge:Be photoconductor covering the 45 to 55 micron region. LW1, SW2, SW3, SW4, SW5 are unstressed Ge:Ga photoconductors which cover the 50 to 120 micron region. LW2, LW3, LW4, LW5 are uniaxially stressed Ge:GA photoconductors covering the range from 100 to 200 microns. The stress applied to each detector will be adjusted in order to get the peak response in the corresponding wavelength range, and to minimize the dark current of the shorter wavelength stressed detectors. Stressed and unstressed detectors are located alternatively in order to receive the first and second order of the diffracted beam.

Lenaour, C.↗

Effects of ionizing radiation on cryogenic infrared detectors

The Diffuse Infrared Background Experiment (DIRBE) is one of three experiments to be carried aboard the Cosmic Background Explorer (COBE) satellite scheduled to be launched by NASA on a Delta rocket in 1989. The DIRBE is a cryogenic absolute photometer operating in a liquid helium dewar at 1.5 K. Photometric stability is a principal requirement for achieving the scientific objectives of this experiment. The Infrared Astronomy Satellite (IRAS), launched in 1983, which used detectors similar to those in DIRBE, revealed substantial changes in detector responsivity following exposure to ionizing radiation encountered on passage through the South Atlantic Anomaly (SAA). Since the COBE will use the same 900 Km sun-synchronous orbit as IRAS, ionizing radiation-induced performance changes in the detectors were a major concern. Here, ionizing radiation tests carried out on all the DIRBE photodetectors are reported. Responsivity changes following exposure to gamma rays, protons, and alpha particle are discussed. The detector performance was monitored following a simulated entire mission life dose. In addition, the response of the detectors to individual particle interactions was measured. The InSb photovoltaic detectors and the Blocked Impurity Band (BIB) detectors revealed no significant change in responsivity following radiation exposure. The Ge:Ga detectors show large effects which were greatly reduced by proper thermal annealing.

Moseley, S. H.↗

Proton-induced radiation damage in germanium detectors

High-purity germanium (HPGe) detectors will be used in future space missions for gamma-ray measurements and will be subject to interactions with energetic particles. To simulate this process, several large-volume n-type HPGe detectors were incrementally exposed to a particle fluence of up to 10 to the 8th protons/sq cm (proton energy: 1.5 GeV) at different operating temperatures (90 to 120 K) to induce radiation damage. Basic scientific and engineering data on detector performance were collected. During the incremental irradiation, the peak shape produced by the detectors showed a significant change from a Gaussian shape to a broad complex structure. After the irradiation, all detectors were thoroughly characterized by measuring many parameters. To remove the accumulated radiation damage, the detectors were stepwise-annealed at temperatures below 110 C, while kept in their specially designed cryostats. This study shows that n-type HPGe detectors can be used in charged-particle environments as high-energy resolution devices until a certain level of radiation damage is accumulated and that the damage can be removed at moderate annealing temperatures and the detector returned to operating condition.

Brueckner, J.↗

The Zero-Degree Detector System

We will report on a detector system used for accelerator measurement of nuclear fragmentation cross sections. This system consists of two detector planes, each carrying a ring of 8 detectors. Each detector has 64 pads. These two detector planes are arranged facing each other so that the matching detector pads on each plane form a two element charged particle telescope. Each of these telescopes is capable of determining the elemental identity of nuclear fragments passing through it. The system is used to measure light fragment production in the presence of heavier fragments. We will present a detailed discussion of the 64-pad detector design, the substrate design. The front-end electronics used to read out the signals is based on a custom VLSI chip developed for the Advanced Thin Ionization Calorimeter experiment which has been flown successfully twice in Antarctica. Each of these chips has 16 channels and each channel consists of a charge-sensitive preamplifier followed by a shaping amplifier and a track-and-hold circuit. The track-and-hold circuits are connected via a multiplexer to an output line driver. This allows the held signals to be presented, one-by-one via a common data line to a analog-to-digital converter. Because the output line driver can be placed in a high input impedance state when not in use, it is possible to daisy-change many chips on the same common data line. The front-end electronics and data readout scheme will be discussed in detail. The Zero Degree Detector has been used in several accelerator experiments conducted at the NASA Space Radiation Laboratory and the Alternating Gradient Synchrotron at Brookhaven National Laboratory as well as at the HIMAC accelerator in Japan. We will show examples of data taken at these accelerator runs to demonstrate how the system works.

Adams, James H.↗

X-Ray Detector Research at MSFC for Space Applications

NASA's Vision for Space Exploration has specific goals aimed at exploring the Solar System. This vision, under presidential mandate includes landing humans on the moon before the end of the next decade, paving the way for eventual journeys to Mars and beyond. The first missions to the moon will be in the form of both Orbiters and Landers, with the goal of paving the way for human return. One of the instruments we are currently working on,in collaboration with Brookhaven National Laboratory, is a lunar orbiter fluorescent x-ray spectrometer to finely map the light elements (down to Carbon) on surface of the moon. Funded NASA s Planetary Instrument Definition and Development Program the instrument is based on silicon drift detector arrays read out by custom ASICs. These offer the promise of high spectral resolution, necessary for resolving weak lines against a strong background continuum, and very low power requirements, necessary for large areas (greater than 500 square centimeters) required for future lunar missions. Further, the inherent radiation hardness of these detectors makes them ideal candidates for exploring the Jovian system, where the harsh radiation environment from Jupiter s radiation belts creates unfavorable detector conditions. Looking beyond our solar system, in the hard x-ray regime (20-80keV.), we are studying Cadmium-Zinc-Telluride pixilated detectors as feasible candidates for focal plane detectors of a hard x-ray telescope. This energy region bridges the gap between thermal and non-thermal x-ray emission from astronomical sources, will allow us to better understand supernovae nucleosynthesis (such as through the Ti-44 lines at 68keV and 78keV), Active Galactic Nuclei and other compact objects, more completely. The detectors that we are characterizing are 2mm in thickness and are pixilated with a 16x16 array of 300 micrometer pitch pixels (50micometer gap). These detectors are designed at Rutherford Appleton Laboratory, material is from eV Products, and polymer flip-chip assembly was performed by a commercial vendor. An energy resolution of 2.0% at 60keV (or better) should allow us to sufficiently distinguish lines of interest from background continuum, and the detector spatial resolution should be fine enough to over-sample the focal spot from the x-ray focusing optics by about a factor of two. Full technical details of these developments will be presented.

Gaskin, Jessica↗

Space Radiation Detector with Spherical Geometry

A particle detector is provided, the particle detector including a spherical Cherenkov detector, and at least one pair of detector stacks. In an embodiment of the invention, the Cherenkov detector includes a sphere of ultraviolet transparent material, coated by an ultraviolet reflecting material that has at least one open port. The Cherenkov detector further includes at least one photodetector configured to detect ultraviolet light emitted from a particle within the sphere. In an embodiment of the invention, each detector stack includes one or more detectors configured to detect a particle traversing the sphere.

Wrbanek, John D.↗