Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DIPOLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Reverberation effects on directionality and response of stationary monopole and dipole sources in a wind tunnel

Analytical solutions for the three dimensional inhomogeneous wave equation with flow in a hardwall rectangular wind tunnel and in the free field are presented for a stationary monopole noise source. Dipole noise sources are calculated by combining two monopoles 180 deg out of phase. Numerical calculations for the modal content, spectral response and directivity for both monopole and dipole sources are presented. In addition, the effect of tunnel alterations, such as the addition of a mounting plate, on the tunnels reverberant response are considered. In the frequency range of practical importance for the turboprop response, important features of the free field directivity can be approximated in a hardwall wind tunnel with flow if the major lobe of the noise source is not directed upstream. However, for an omnidirectional source, such as a monopole, the hardwall wind tunnel and free field response are not comparable.

Baumeister, K. J.↗

Theoretical study of the dipole moments of selected alkaline-earth halides

Ab initio calculations at the self-consistent-field (SCF), singles-plus-doubles configuration-interaction (SDCI), and coupled-pair functional (CPF) level, are reported for the dipole moments and dipole derivatives of the X2Sigma(+) ground states of BeF, BeCl, MgF, MgCl, CaF, CaCl, and SrF. For comparison, analogous calculations are performed for the X1Sigma(+) state of KCl. The CPF results are found to be in remarkably better agreement with experiment than are the SCF and SDCI results. Apparently higher excitations are required to properly describe the radial extent along the bond axis of the remaining valence electron on the alkaline-earth metal.

Langhoff, S. R.↗

Theoretical study of the electric dipole moment function of the ClO molecule

The potential energy function and electric dipole moment function (EDMF) are computed for ClO X 2Pi using several different techniques to include electron correlation. The EDMF is used to compute Einstein coefficients, vibrational lifetimes, and dipole moments in higher vibrational levels. The band strength of the 1-0 fundamental transition is computed to be 12 + or - 2 per sq cm atm determined from infrared heterodyne spectroscopy. The theoretical methods used include SCF, CASSCF, multireference singles plus doubles configuration interaction (MRCI) and contracted CI, coupled pair functional (CPF), and a modified version of the CPF method. The results obtained using the different methods are critically compared.

Pettersson, L. G. M.↗

Dipole moments and transition probabilities of the a 3Sigma(+)g - b 3Sigma(+)u system of molecular hydrogen

Multiconfiguration variational calculations of the electronic wave functions of the a 3Sigma(+)g and b 3Sigma(+)u states of molecular hydrogen are presented, and the electric dipole transition moment between them (of interest in connection with stellar atmospheres and the UV spectrum of the Jovian planets) is obtained. The dipole moment is used to calculate the probabilities of radiative transitions from the discrete vibrational levels of the a 3Sigma(+)g state to the vibrational continuum of the repulsive b 3Sigma(+)u state as functions of the wavelength of the emitted photons. The total transition probabilities and radiative lifetimes of the levels v prime = 0-20 are presented.

Guberman, S.↗

Satellite sweeping in offset, tilted dipole fields

The paper presents a theory for the longitudinally averaged satellite sweeping rate in an offset, tilted dipole magnetic field. It includes the reductions in the sweeping rate when the moon radius is not large compared to the gyroradius or the azimuthal drift distance during a bounce period. With a large tilt angle between the magnetic and rotation axes, moons make large excursions in dipole L value, and more than one moon can sweep at a given L. The sweeping rate peaks at the minimum L for each moon. If the gyroradius is large, additional peaks can occur when the particle mirrors near the moon latitude. To illustrate the theory, sweeping rates are evaluated for parameters relevant to the observations at Uranus by the Voyager 2 Low Energy Charged Particles Experiment. Calculated sweeping rates for ions and electrons are typically two or three orders of magnitude less than the strong-diffusion loss rate. The observation of sweeping signatures at Uranus would imply that pitch-angle scattering there occurs at a rate far below the strong-diffusion limit, contrasting with the situation for energetic ions in the inner Jovian magnetosphere.

Paonessa, Mark T.↗

Differential oscillator strengths and dipole polarizabilities for transitions of the helium sequence

The dipole radial integral for an initial discrete 1s state and a final continuum state has been calculated under the screened hydrogenic model. In this model, single-electron hydrogenic wave functions are employed, and the initial and the final states are treated by two different effective-charge parameters. Numerical values of differential oscillator strengths for transitions from 1s2 1S to the continuum for the helium sequence ions are obtained. Also calculated are the dipole polarizabilities, which are found to be in excellent agreement with the results of other authors.

Khan, F.↗

Theoretical study of the dipole moment function of OH(X2Pi)

A theoretical study of the sensitivity of the dipole moment function (DMF) of the X2Pi ground state of OH to basis-set saturation and to refinements in the correlation treatment is presented. Emphasis is placed on determining the slope of the DMF at r(e) and the r value at which the maximum occurs. Consideration is given to the effect of oxygen polarization functions up through h type, expansion of the active orbital space to include the O 3d-delta orbital, the effect of higher excitations using the averaged coupled-pair functional method, and the effect of evaluating the dipole moment as an energy derivative rather than as an expectation value. The theoretical DMFs obtained here, which should be the most accurate to date, differ markedly from an empirical DMF of Turnbull and Lowe that is based on experimentally derived intensity ratios. The theoretical DMFs agree better with a recently published DMF of Nelson et al., but suggest that this empirical DMF is also inaccurate for r greater than 2.3 a0.

Langhoff, Stephen R.↗

Electric dipole moment of the electron and of the neutron

It is shown that if Higgs-boson exchange mediates CP violation a significant electric dipole moment for the electron can result. Analogous effects can contribute to the neutron's electric dipole moment at a level competitive with Weinberg's three-gluon operator.

Barr, S. M.↗

Model of Jovian F region ionosphere (Saturnian ionosphere in offset dipole approximation)

Researchers investigated the offset effect of Saturn's dipole on its ionosphere. The magnetic field of Saturn is primarily that of a dipole closely aligned to the rotational axis, but displaced northward from the center by a distance approximately equal to 0.05 R sub S, R sub S being the reference radius of Saturn. This offset effect would manifest itself most prominently between the ionospheric profiles in the Northern and Southern Hemispheres of Saturn.

Tan, A.↗

Inclusion of Theta(12) dependence in the Coulomb-dipole theory of the ionization threshold

The Coulomb-dipole (CD) theory of the electron-atom impact-ionization threshold law is extended to include the full electronic repulsion. It is found that the threshold law is altered to a form in contrast to the previous angular-independent model. A second energy regime, is also identified wherein the 'threshold' law reverts to its angle-independent form. In the final part of the paper the dipole parameter is estimated to be about 28. This yields numerical estimates of E(a) = about 0.0003 and E(b) = about 0.25 eV.

Srivastava, M. K.↗

Dipole moments and transition probabilities of the i 3Pi sub g-b 3Sigma(+) sub u, c 3Pi sub u-a 3Sigma(+) sub g, and i 3Pi sub g-c 3Pi sub u systems of molecular hydrogen

Bonn-Oppenheimer-based ab initio calculations of dipole moments from the i 3Pi sub g-b 3Sigma(+) sub u, c 3Pi sub u-a 3Sigma(+) sub g, and i 3Pi sub g-c 3Pi sub u transitions of H2 have been conducted, to yield a tabulation of the dipole transition probabilities and Franck-Condon factors. These factors are given for transitions originating in the lowest vibrational level of the ground X 1Sigma(+) sub g state.

Guberman, Steven L.↗

Double dipole antenna SIS receivers at 100 and 400 GHz

Antenna patterns were measured between 95 and 120 GHz for a double dipole antenna / ellipsoidal lens combination. The structure produces a non-astigmatic beam with low side lobe levels over that whole band. A heterodyne SIS receiver based on this concept gave a best noise temperature of 145 K DSB at 98 GHz. Measurements were also made with a 400 GHz heterodyne SIS receiver, using a double dipole antenna in conjunction with a hyperhemispherical lens. The best noise temperature was 220 K DSB at 402 GHz. On-chip stubs were used to tune out the SIS junction capacitance.

Skalare, A.↗

Bond length, dipole moment, and harmonic frequency of CO

A detailed comparison of some properties of CO is given, at the modified coupled-pair functional, single and double excitation coupled-cluster (CCSD), and CCSD(T) levels of theory (including a perturbational estimate for connected triple excitations), using a variety of basis sets. With very large one-particle basis sets, the CCSD(T) method gives excellent results for the bond distance, dipole moment, and harmonic frequency of CO. In a (6s 5p 4d 3f 2g 1h) + (1s 1p 1d) basis set, the bond distance is about 0.005a0 too large, the dipole moment about 0.005 a.u. too small, and the frequency about 6/cm too small, when compared with experimental results.

Barnes, Leslie A.↗

Waves in space plasma dipole antenna subsystem

The Waves In Space Plasma (WISP) flight experiment requires a 50-meter-long deployable dipole antenna subsystem (DASS) to radiate radio frequencies from the STS Orbiter cargo bay. The transmissions are to excite outer ionospheric plasma between the dipole and a free-flying receiver (Spartan) for scientific purposes. This report describes the singular DASS design requirements and how the resulting design satisfies them. A jettison latch is described in some detail. The latch releases the antenna in case of any problems which might prevent the bay doors from closing for re-entry and landing of the Orbiter.

Thomson, Mark↗

Imaging the effect of dipole tilt on magetotail boundaries

Eight years of Interplanetary Monitoring Platform (IMP) 8, four years of International Sun Earth Explorer (ISEE) 2, and one year of IMP 7 magnetometer data have been combined to produce an 'image' of the average magnetic field for a YZ cross section (aberrated GSM) of the magnetotail at a downtail distance of 25 R(sub E). The shape of the neutral sheet and magnetopause boundaries can be observed directly from the images. A fitting function that qualitatively matches the observed boundary shape can then be chosen. This approach improves on previous fits to possible unsuitable functional forms specified independently of the data. In addition, as a refinement of previous studies, we have corrected for varying solar wind dynamic pressure and the effects of tail flaring. We find the magnetopause is displaced above the XY plane with increasing dipole tilt. The neutral sheet is found to curve slightly more than the model of Fairlfield (1980) during times of large dipole tilt and near the flanks appears to differ substantially from the neutral sheet shape given by the analytic model of Voigt (1984), the more recent neutral sheet model of Dandouras (1988) based on the Voigt model, and the semi-empirical model of Tsyganenko (1989).

Hammond, C. Max↗

Kinetic and thermodynamic properties of a convecting plasma in a two-dimensional dipole field

Charged particle guiding center motion is considered in the magnetic field of a two-dimensional ('line') dipole on which is superimposed a small, static, perpendicular electric field. The parallel equation of motion is that of a simple harmonic oscillator for cos theta, the cosine of magnetic colatitude theta. Equations for the perpendicular electric and magnetic drifts are derived as well as their bounce-averaged forms. The latter are solved to yield a bounce-averaged guiding center trajectory, which is the same as that obtained from conversation of magnetic moment mu, longitudinal invariant J, and total (kinetic plus electrostatic) energy K. The algebraic simplicity of the trajectory equations is also manifest in the forms of the invariants. An interesting result is that guiding centers drift in such a way that they preserve the values of their equatorial pitch angles and (equivalently) mirror latitudes. The most general Maxwellian form of the equilibrium one-particle distribution function f is constructed from the invariants, and spatially varying density and pressure moments, parallel and perpendicular to the magnetic field, are identified. Much of the paper deals with the more restricted problem in which f is specified as a bi-Maxwellian over a straight line of finite length in the equatorial plane of the dipole and perpendicular to field lines. This might be thought of as specifying a cross-tail ion injection source; our formalism then describes the subsequent spatial development. The distribution away from the source is a scaled bi-Maxwellian but one that is cut off at large and small kinetic energies, which depend on position. Density and pressure components are reduced from the values they would have if the total content of individual flux tubes convected intact. The equatorial and meridional variations of density and pressure components are examined and compared systematically for the isotropic and highly anisotropic situations. There appears to be little qualitative difference due to anisotropy. An anisotropy measure is defined, and its spatial variation determined as a signature of possible MHD instability. Extreme values are found, larger than at the source, but the plasma beta in such regions is probably so low as to render the effect inconsequential energetically. Finally, the possible consequence of 'nonadia- batic' pressure profiles on electrostatic interchanges is considered, and a boundary delineating stabilizing and destabilizing regions determined.

Huang, T. S.↗

Studying Room Acoustics using a Monopole-Dipole Microphone Array

The use of a soundfield microphone for examining the directional nature of a room impulse response was reported recently. By cross-correlating monopole and co-located dipole microphone signals aligned with left-right, up-down, and front-back axes, a sense of signal direction of arrival is revealed. The current study is concerned with the array's ability to detect individual reflections and directions of arrival, as a function of the cross-correlation window duration. If is window is too long, weak reflections are overlooked; if too short, spurious detections result. Guidelines are presented for setting the window width according to perceptual criteria. Formulas are presented describing the accuracy with which direction of arrival can be estimated as a function of room specifics and measurement noise. The direction of arrival of early reflections is more accurately determined than that of later reflections which are quieter and more numerous. The transition from a fairly directional sound field at the beginning of the room impulse response to a uni-directional diffuse field is examined. Finally, it is shown that measurements from additional dipole orientations can significantly improve the ability to detect reflections and estimate their directions of arrival.

Begault, Durand R.↗

Equivalent Dipole Vector Analysis for Detecting Pulmonary Hypertension

Various 12-lead ECG criteria have been established to detect right ventricular hypertrophy as a marker of pulmonary hypertension (PH). While some criteria offer good specificity they lack sensitivity because of a low prevalence of positive findings in the PH population. We hypothesized that three-dimensional equivalent dipole (ED) model could serve as a better detection tool of PH. We enrolled: 1) 17 patients (12 female, 5 male, mean age 57 years, range 19-79 years) with echocardiographically detected PH (systolic pulmonary arterial pressure greater than 35 mmHg) and no significant left ventricular disease; and 2) 19 healthy controls (7 female, 12 male, mean age 44, range 31-53 years) with no known heart disease. In each subject we recorded a 5-minute high-resolution 12-lead conventional ECG and constructed principal signals using singular value decomposition. Assuming a standard thorax dimension of an adult person with homogenous and isotropic distribution of thorax conductance, we determined moving equivalent dipoles (ED), characterized by the 3D location in the thorax, dipolar strength and the spatial orientation, in time intervals of 5 ms. We used the sum of all ED vectors in the second half of the QRS complex to derive the amplitude of the right-sided ED vector (RV), if the orientation of ED was to the right side of the thorax, and in the first half the QRS to derive the amplitude of the left-sided vector (LV), if the orientation was leftward. Finally, the parameter RV/LV ratio was determined over an average of 256 complexes. The groups differed in age and gender to some extent. There was a non-significant trend toward higher RV in patients with PH (438 units 284) than in controls (280 plus or minus 140) (p = 0.066) but the overlap was such that RV alone was not a good predictor of PH. On the other hand, the RV/LV ratio was a better predictor of PH, with 11/17 (64.7%) of PH patients but only in 1/19 (5.3%) control subjects having RV/LV ratio greater than or equal to 0.70 (p less than 0.001). The use of ED for evaluating PH shows good specificity at a reasonable sensitivity. The results are limited due to the small study groups and differences in age and gender, but further investigations are warranted, including of ED's diagnostic accuracy for PH versus that of other proposed ECG and VCG criteria.

Harlander, Matevz↗