Optimization of lithium-glass fibers with lithium depleted coating for neutron detection
Neutron-detecting scintillating glass uses 6 Li to capture thermal neutrons to produce an a and triton particle, which have $a$ range of 6 $µm$ and 36 $µm$, respectively. Captures on the surface of the glass can cause one of the particles to not deposit their energy in the glass causing the neutron to not be detected. This effect can be mitigated in lithium glass scintillators by coating lithium- glass fibers with lithium depleted scintillating glass. Thus, the scintillator’s efficiency will be increased. Results from this work show that a 20-60% increase in neutron efficiency depending on core size can be achieved with scintillating glass coatings.