Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Correlation analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

A Summary of Test Results from a NASA Lift + Cruise eVTOL Crash Test

On November 9, 2022, the National Aeronautics and Space Administration (NASA) conducted a full-scale crash test of the NASA Lift+Cruise (LPC) reference vehicle at the NASA Langley Research Center Landing and Impact Research Facility (LandIR) under combined vertical and horizontal impact conditions to simulate a severe but survivable crash. The LPC test article is a carbon-composite skin/frame structure design, developed and fabricated for the cabin section only. The test utilized various configurations of seats and Anthropomorphic Test Devices (ATDs, a.k.a. crash test dummies) intended to encompass a variety of occupant conditions. In addition, an in-house developed energy absorbing subfloor was utilized for the evaluation of load attenuation. Overhead mass was simulated using attached lifting hardware and other systems were simulated using ballast mass. The test article impacted the ground with velocities of 38.1 ft/s horizontal and 31.4 ft/s vertical. During the first approximately 38 milliseconds (ms), the cabin section experienced a large amount of acceleration on the belly which was attenuated by the subfloor structures and seats. Over the next approximately 160 ms, the test article experienced failure in the a-, b- and c-pillars, leading to a partial collapse of the overhead structure. Test data was collected on the belly, floors, seats, overhead mass, and tail. In addition, there was high speed full-field digital image correlation analysis data collected on the port side skin surface. Collected ATD data showed that the ATDs seated in the energy absorbing seats experienced loads at limits below the those in current regulations. Even without an energy absorbing seat, the energy absorbing subfloors crushed as intended, and limited the load on the large 95 th percentile ATD to 10% over suggested limits. The collapse of the roof did affect the 95 th percentile ATD, which showed high neck loading values due to head contact, whereas survivable volume was maintained for the other ATDs. While the energy absorbing subfloor and energy absorbing seats both contributed to occupant load attenuation, further optimization is suggested to increase their robustness.

evtol↗

The Correlation Between Arctic Sea Ice, Cloud Phase and Radiation Using A-Train Satellites

Climate warming has a stronger impact on Arctic climate and sea ice cover (SIC) decline than previously thought. Better understanding and characterization of the relationship between sea ice and clouds and the implications for surface radiation is key to improving our confidence in Arctic climate projections. Here we analyze the relationship between sea ice, cloud phase and surface radiation over the Arctic, defined as north of 60° N, using active- and passive-sensor satellite observations from three different datasets. We find that all datasets agree on the climatology of and seasonal variability in total and liquid-bearing (liquid and mixed-phase) cloud covers. Similarly, our results show a robust relationship between decreased SIC and increased liquid-bearing clouds in the lowest levels (below 3 km) for all seasons (strongest in winter) but summer, while increased SIC and ice clouds are positively correlated in two of the three datasets. A refined map correlation analysis indicates that the relationship between SIC and liquid-bearing clouds can change sign over the Bering, Barents and Laptev seas, likely because of intrusions of warm air from low latitudes during winter and spring. Finally, the increase in liquid clouds resulting from decreasing SIC is associated with enhanced radiative cooling at the surface. Our findings indicate that the newly formed liquid clouds reflect more shortwave (SW) radiation back to space compared to the surface, generating a cooling effect of the surface, while their downward longwave (LW) radiation is similar to the upward LW surface emission, which has a negligible radiative impact on the surface. This overall cooling effect should contribute to dampening future Arctic surface warming as SIC continues to decline.

Arctic climate↗

Lowering Barriers to Science and Space Weather Research at the Community Coordinated Modeling Center (CCMC)

The Space Weather and Heliophysics research and modeling community has been pushing the limits of our ability to understand and predict space weather events. The Community Coordinated Modeling Center (CCMC, https://ccmc.gsfc.nasa.gov) supports the community by providing a convenient collaborative platform hosting space weather models, model simulation data, curated datasets of solar events, and associated value-added services. Using these services, researchers and other end-users may exercise, evaluate, and intercompare contributed models, triage designated R2O models, as well as collaborate on a continuously updated archive of model run results. We will focus on CCMC’s ongoing commitment to the principles and guidelines of the Open Science initiative. Particularly, we will discuss our work towards making our services more transparent and our library of model simulations more accessible, open, and reproducible. We will introduce our recent tools for data discovery and correlative analysis designed to further increase the value of the user-generated data and metadata. We will also present our recent work on making heliophysical models more accessible and open to the community, particularly through simplified user experience and expert domain support. We will report on our progress in establishing an inter-center infrastructure with the ESA Virtual Space Weather Modelling Centre (VSWMC), designed to cross organizational boundaries and provide streamlined access to a joint palette of the models.

space weather↗

Exploring Flooded Fraction Prediction through Machine Learning Models Focusing on Medical Infrastructure in the Southeast U.S. Coastal Areas

Rising sea levels due to climate change increasingly threaten medical infrastructure through flooding. This study develops machine learning models to predict flood exposure for 11,508 medical facilities in the southeastern coastal regions of the United States by integrating datasets including meteorological, hydrological, topographic, and geological data, the Natural Risk Index, and historical flood records from NASA, HIFLD, and FEMA. Six regression models, namely Linear Regression, Support Vector Regression, Random Forest, k-Nearest Neighbors, XGBoost, and Artificial Neural Networks, are trained using 16 explanatory variables identified through literature review and correlation analysis. Data preprocessing employs the SMOGN for class imbalance and Winsorization for outliers. Model performance is evaluated using MAE, MSE, and RMSE, with Random Forest and XGBoost models achieving the highest performance (MSE of 2.58e-5 and 3.69e-5, respectively). This multifactorial approach allows the models to capture complex flood-influencing relationships, enhancing adaptability and performance across geographic regions. Future work focuses on expanding across the U.S. and developing a near real-time flood monitoring system.

Jihoon Chung↗

AGC-4 Experiment Irradiation Monitoring Data Qualification Final Report

The Graphite Technology Development Program ran a series of six experiments to quantify the effects of irradiation on nuclear grade graphite. This report focuses on the fourth experiment, Advanced Graphite Creep 4 (AGC 4). The Advanced Reactor Development (ARD) Technology Development Office (TDO) Program for research and development activities require documentation of qualified monitoring data to design and license the first high-temperature reactor nuclear plant. Qualified data meets the requirements for use as described in the experiment planning and quality assurance documents. Failed data do not meet the requirements and provide no useable information. Trend data may not meet all requirements but still provide some useable information. Use of Trend data requires assessment of how any deficiencies affect a particular use of the data. AGC-4 began with Advanced Test Reactor (ATR) Cycle 157D on May 30, 2015. After irradiating the graphite for two cycles, the capsule was removed from the reactor after ATR Cycle 158A, which ended on January 2, 2016, due to interference with another experiment. Irradiation was resumed with Cycle 162A on October 7, 2017 after the interfering experiment was removed from the reactor. AGC-4 irradiation completed by the end of Cycle 166B on January 10, 2020. Between Cycles 162A and 166B, AGC-4 capsule was removed from the reactor core during two Powered Axial Locator Mechanism (PALM) Cycles 163A and 165A to avoid overheating. All thermocouples (TCs) have functioned throughout the AGC-4 experiment. A total of 9,256,184 out of all 11,167,213 temperature records (or 82.9%) are Qualified for use by the ARD Program and 1,911,029 missing values are Failed. Argon, helium, and total gas flow data were within expected ranges, except only eight out-of-range values occurred during outages. A total of 21,240,627 out of all 22,288,5103 gas flow rates (or 92.8%) are Qualified for use by the ARD Program and 1,644,476 are Failed records mostly due to missing values. Discharge gas line moisture values were consistently low during full ATR power, except for 162B, when moisture content was increasing to more than 200 ppmv by the end of this cycle. During outages, moisture content reached as high as 700 ppmv. 1,089,941 out of a total of 1,107,331 moisture values (or 98.4%) are within the measurement range of the instrument and are Qualified for use by the ARD Program and 17,390 missing moisture values are Failed. Graphite creep specimens were subjected to one of three loads: 393, 491, or 589 lbf. For a brief period during Cycle 157D between 12:19 on June 2, 2015, and 08:23 on June 11, 2015, the load cells were wired incorrectly, resulting in missing stack load data. Missing stack loads were estimated from measured ram pressures using regression equations developed from the existing data from Cycle 157D. Estimated stack loads during this period are considered to be an accurate representation of actual load applied to the stacks. These loads deviate slightly from the planned loads. This deviation does not prevent the data from being Qualified for use but must be taken into account when analyzing the effect of load on creep. 6,095,728 out of a total of 6,403,985 moisture values (or 95.2%) are within the measurement range of the instrument and are Qualified for use by the ARD Program and 308,257 missing load values are Failed. Stack displacement increased consistently throughout the eight cycles, with total displacement reached highest value of 2.4 in by the end of irradiation. During ATR outages, a set of pneumatic rams raised the stacks of graphite creep specimens to ensure the specimens were not stuck within the test train. This stack raising was performed seven times throughout irradiation. All stacks were raised successfully each time. 4,744,974 out of a total of 6,094,513 displacement values (or 77.9%) are within the measurement range of the instrument and are Qualified for use by the ARD Program and 1,349,539 displacement values are Failed mostly due to missing values. Analyses were conducted on correlations between TCs to look for trends and step changes that might indicate instrument degradation or failure. Correlation analysis was used to identify instances when TCs form short circuits, referred to as virtual junctions, which result in TCs reporting temperatures from some location in the capsule other than the location where they were intended to read. No evidence of virtual junctions was found. Analyses were also conducted on control charts of temperature differences of between two TCs, which are expected to behave consistently throughout the entire irradiation period. Upward or downward trend over time indicates at least one TC in the pair was drifted. Examining control charts for all 66 possible pairs out of twelve TCs installed in the AGC-4 capsules reveal no clear drift failures occurred, except unstable behavior of two TCs in Zone 3, TC-7 and TC-8, over irradiation time. In conclus

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Challenges and Lessons Learned from fabrication, testing and analysis of eight MQXFA Low Beta Quadrupole magnets for HL-LHC

By the end of October 2022, the US HL-LHC Accelerator Upgrade Project (AUP) had completed fabrication of ten MQXFA magnets and tested eight of them. The MQXFA magnets are the low beta quadrupole magnets to be used in the Q1 and Q3 Inner Triplet elements of the High Luminosity LHC. This AUP effort is shared by BNL, Fermilab, and LBNL, with strand verification tests at NHMFL. An important step of the AUP QA plan is the testing of MQXFA magnets in a vertical cryostat at BNL. The acceptance criteria that could be tested at BNL were all met by the first four production magnets (MQXFA03-MQXFA06). Subsequently, two magnets (MQXFA07 and MQXFA08) did not meet some criteria and were disassembled. Lessons learned during the disassembly of MQXFA07 caused a revision to the assembly specifications that were used for MQXFA10 and subsequent magnets. In this paper, we present a summary of: 1) the fabrication and test data of all the MQXFA magnets; 2) the analysis of MQXFA07/A08 test results with characterization of the limiting mechanism; 3) the outcome of the investigation, including the lessons learned during MQXFA07 disassembly; and 4) the finite element analysis correlating observations with test performance.

43 PARTICLE ACCELERATORS↗

HDG-1 Experiment Irradiation Monitoring Data Qualification Final Report

SUMMARY The U.S. Department of Energy (DOE) Advanced Reactor Technologies (ART) Graphite Research and Development (GRD) Program is conducting a series of six experiments to quantify the effects of irradiation on nuclear-grade graphite. This report documents the qualification of irradiation monitoring data for the fifth experiment, High Dose Graphite-1 (HDG-1). Qualified monitoring data are required by the ART program to support the design and licensing of the first high-temperature reactor (HTR) nuclear plant. Data are classified as Qualified if they meet the usage requirements described in the experiment planning and quality assurance (QA) documents, Failed if they do not meet those requirements and provide no usable information, or Trend if they do not fully meet all requirements but still provide useful information subject to an assessment of how any deficiencies may affect a particular use of the data. HDG-1 irradiation began with Advanced Test Reactor (ATR) Cycle 168B on August 24, 2020, and concluded after Cycle 173C on January 27, 2025. The HDG-1 capsule was removed from the reactor core twice—during core internal change (CIC) Cycle 170A and powered axial locator mechanism (PALM) Cycle 172A—to prevent overheating of the graphite specimens during high-power PALM cycles. The capsule was therefore irradiated during a total of seven normal ATR cycles: 168B, 169A, 171A, 171B, 173A, 173B, and 173C. Irradiation monitoring data evaluated in this report include thermocouple (TC) temperature, gas flow rate, gas moisture, gas pressure, specimen load, and graphite stack displacement. Temperature. A total of 14,508,065 TC temperature records were captured. Of these, 13,901,785 (95.8%) are Qualified and 606,280 (4.2%) are Failed. The principal source of failed temperature data was the instrument failure of TC-9 (Zone 2) on June 24, 2024, and TC-10 (Zone 1) on July 5, 2024, near the end of Cycle 173A, which resulted in 595,554 Failed readings. An additional 379 missing values and 10,347 slightly negative values from TC-13 during ATR outages are also Failed. Neither TC-9 nor TC-10 was used as a temperature-control TC, and their failures did not compromise capsule condition monitoring. Correlation analysis of all 13 TCs found no evidence of virtual junction formation. Control chart analysis revealed clear downward drift of approximately 80°C for TC-6 (Zone 3) relative to other stable TCs, and possible downward drift of approximately 60°C for TC-13 relative to the Zone 5 control TC (TC-1), though TC-13 remained consistent with the Zone 2 control TC (TC-12). Gas flow. A total of 20,088,090 gas flow rate records were captured. Of these, 19,941,463 (99.3%) are Qualified and 146,627 (0.7%) are Failed due to missing values. All argon, helium, and total gas flow data were within expected ranges throughout the irradiation. Gas moisture. A total of 1,116,005 outlet gas moisture values were captured. Of these, 1,101,421 (98.7%) are Qualified and 14,584 (1.3%) are Failed, comprising 14,556 out-of-range values and 28 missing values. The out-of-range moisture values exceeded 22,000 ppmv for approximately 1 week at the beginning of Cycle 173A, when accumulated moisture evaporated after the capsule was retrieved from water storage during PALM Cycle 172A and reinserted into the east flux trap. Moisture levels returned to below 25 ppmv for the remaining three cycles, and the transient high-moisture event did not affect the integrity of specimen irradiation. Gas pressure. A total of 7,812,035 gas pressure values were captured. Of these, 6,642,048 (85.0%) are Qualified and 1,169,987 (15.0%) outlet pressure values are Failed, comprising 718,537 zero outlet pressure values due to sensor failure from Cycle 168B through Cycle 171B, 54,550 missing values, and 396,900 too-low outlet pressure values, ranging from 1.1 to 1.6 psia after sensor replacement during Cycle 173A. Load. A total of 6,696,030 load values were captured. Of these, 6,694,580 (99.98%) are Qualified and 1,450 (0.02%) are Failed due to missing values. Applied loads to the six specimen stacks were stable throughout the irradiation. Stack displacement. A total of 6,696,030 displacement values were captured. Of these, 5,713,297 (85.32%) are Qualified and 3,781 (0.06%) are Failed due to missing values. Stack displacement increased consistently throughout the irradiation, reaching approximately 3.08 in. for Channels 5 and 6 by the end of irradiation. 978,952 (14.62%) substantially elevated displacements observed for Channel 6 beginning in Cycle 171A and for Channel 5 beginning in Cycle 173A are assigned Trend status. Raising pressure. A total of 1,115,999 raising pressure values were captured. Of these, 1,115,430 (99.95%) are Qualified and 569 (0.05%) are Failed due to missing values. Ram pressure. A total of 6,696,030 ram pressure values were captured. Of these, 6,692,249 (99.95%) are Qualified and 3,484 (0.05%) are Failed due to missing values. Stack raising was perf

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermally induced damage in composite space structure: Predictive methodology and experimental correlation

A general analysis method is presented to predict matrix cracks in all plies of a composite laminate, and resulting degraded laminate properties, as functions of temperature or thermal cycles. A shear lag solution of the stresses in the vicinity of cracks and a fracture mechanics crack formation criteria are used to predict cracks. Damage is modeled incrementally, which allows the inclusion of the effects of temperature dependent material properties and softening of the laminate due to previous cracking. The analysis is incorporated into an easy-to-use computer program. The analysis is correlated with experimentally measured crack densities in a variety of laminates exposed to monotonically decreasing temperatures. Crack densities are measured at the edges of specimens by microscopic inspection, and throughout the specimen volumes by x-ray and sanding down of the edges. Correlation between the analytical results and the crack densities in the interiors of the specimens was quite good. Crack densities measured at specimen edges did not agree with internal crack densities (or analyses) in some cases. A free-edge stress analysis clarified the reasons for these discrepancies.

Park, Cecelia↗

Detailed analysis and test correlation of a stiffened composite wing panel

Nonlinear finite element analysis techniques are evaluated by applying them to a realistic aircraft structural component. A wing panel from the V-22 tiltrotor aircraft is chosen because it is a typical modern aircraft structural component for which there is experimental data for comparison of results. From blueprints and drawings supplied by the Bell Helicopter Textron Corporation, a very detailed finite element model containing 2284 9-node Assumed Natural-Coordinate Strain (ANS) elements was generated. A novel solution strategy which accounts for geometric nonlinearity through the use of corotating element reference frames and nonlinear strain displacements relations is used to analyze this detailed model. Results from linear analyses using the same finite element model are presented in order to illustrate the advantages and costs of the nonlinear analysis as compared with the more traditional linear analysis. Strain predictions from both the linear and nonlinear stress analyses are shown to compare well with experimental data up through the Design Ultimate Load (DUL) of the panel. However, due to the extreme nonlinear response of the panel, the linear analysis was not accurate at loads above the DUL. The nonlinear analysis more accurately predicted the strain at high values of applied load, and even predicted complicated nonlinear response characteristics, such as load reversals, at the observed failure load of the test panel. In order to understand the failure mechanism of the panel, buckling and first ply failure analyses were performed. The buckling load was 17 percent above the observed failure load while first ply failure analyses indicated significant material damage at and below the observed failure load.

Davis, D. Dale, Jr.↗

Detailed analysis and test correlation of a stiffened composite wing panel

New finite element analysis methods are examined by application to a complicated composite wing panel from the V-22 rotorcraft. A detailed FEM model with a relatively coarse mesh of 9-node elements was generated, and linear and nonlinear stress analyses, first-ply failure analyses, and buckling analyses were conducted. At low values of applied load, i.e., up to the design ultimate load of the panel, the linear stress analysis accurately predicted the strains and structural response characteristics of the panel.

Davis, D. D., Jr.↗

Buckling analysis and test correlation of high temperature structural panels

This paper focuses on the design, analysis, and test of a high temperature structural panel, constructed of Ti-6-4, subjected to a variety of thermal and mechanical load conditions. A follow-on panel, constructed of TMC, is also discussed in less detail. The design constraints and test set-up are discussed, as well as the test methods that were used: the grid shadow moire method and a single gage force stiffness method. The agreement between the test data and analysis for this test program provides confidence in the methods that are currently being used to design structures for hypersonic vehicles. The agreement also suggests that postbuckled strength may potentially be used to reduce the vehicle weight.

Teare, Wendy P.↗

Model Correlation and Thermal Analysis of xEMU Boot at Lunar South Pole Temperatures

The National Aeronautics and Space Administration (NASA) Artemis program plans to send astronauts to the lunar south pole, a region of the moon that is colder than previous lunar missions and low earth orbit operations. The spacesuit boots that will be used on these missions will be directly impacted by these extremely cold temperatures (down to ~50 K). To assess the performance of the Exploration Extravehicular Mobility Unit (xEMU) lunar boot in these extreme temperatures, the boot was tested at the Jet Propulsion Lab (JPL) in the Cryogenic Ice Transfer, Acquisition Development, and Excavation Laboratory (CITADEL) thermal vacuum (TVAC) chamber. This data was used to correlate thermal models to predict operational performance of the boots on the lunar south pole. This paper documents the data analysis, thermal boot model correlation, and operational predictions conducted using data from the xEMU TVAC test. Data from the test series was used to determine expected thermal conductances within the boot and between the boot and environment. These conductances were used to correlate a Thermal Desktop model of the xEMU boot across 10 different test points which varied external temperature, internal boot ventilation flowrate, and contact pressure. The correlated model was then used to predict operational performance in the lunar south pole. While the predictions indicate promising evidence for performance of the boots at the 100K test point, there is still substantial uncertainty in performance, particularly at the 48K test point. The results of this test series and model correlation stress the importance of improved testing for characterizing the expected thermal resistance between the outside of the boot and the lunar surface.

thermal analysis↗

Model Correlation and Thermal Analysis of xEMU Boot at Lunar South Pole Temperatures

The National Aeronautics and Space Administration (NASA) Artemis program plans to send astronauts to the lunar south pole, a region of the moon that is colder than previous lunar missions and low earth orbit operations. The spacesuit boots that will be used on these missions will be directly impacted by these extremely cold temperatures (down to ~50 K). To assess the performance of the Exploration Extravehicular Mobility Unit (xEMU) lunar boot in these extreme temperatures, the boot was tested at the Jet Propulsion Lab (JPL) in the Cryogenic Ice Transfer, Acquisition Development, and Excavation Laboratory (CITADEL) thermal vacuum (TVAC) chamber. This data was used to correlate thermal models to predict operational performance of the boots on the lunar south pole. This paper documents the data analysis, thermal boot model correlation, and operational predictions conducted using data from the xEMU TVAC test. Data from the test series was used to determine expected thermal conductances within the boot and between the boot and environment. These conductances were used to correlate a Thermal Desktop model of the xEMU boot across 10 different test points which varied external temperature, internal boot ventilation flowrate, and contact pressure. The correlated model was then used to predict operational performance in the lunar south pole. While the predictions indicate promising evidence for performance of the boots at the 100K test point, there is still substantial uncertainty in performance, particularly at the 48K test point. The results of this test series and model correlation stress the importance of improved testing for characterizing the expected thermal resistance between the outside of the boot and the lunar surface.

xEMU↗

Correlating the EMC analysis and testing methods for space systems in MIL-STD-1541A

A study was conducted to improve the correlation between the electromagnetic compatibility (EMC) analysis models stated in MIL-STD-1541A and the suggested testing methods used for space systems. The test and analysis methods outlined in MIL-STD-1541A are described, and a comparative assessment of testing and analysis techniques as they relate to several EMC areas is presented. Suggestions on present analysis and test methods are introduced to harmonize and bring the analysis and testing tools in MIL-STD-1541A into closer agreement. It is suggested that test procedures in MIL-STD-1541A must be improved by providing alternatives to the present use of shielded enclosures as the primary site for such tests. In addition, the alternate use of anechoic chambers and open field test sites must be considered.

Perez, Reinaldo J.↗

Buckling analysis and test correlation of hat stiffened panels for hypersonic vehicles

The paper discusses the design, analysis, and test of hat stiffened panels subjected to a variety of thermal and mechanical load conditions. The panels were designed using data from structural optimization computer codes and finite element analysis. Test methods included the grid shadow moire method and a single gage force stiffness method. The agreement between the test data and analysis provides confidence in the methods that are currently being used to design structures for hypersonic vehicles. The agreement also indicates that post buckled strength may potentially be used to reduce the vehicle weight.

Percy, Wendy C.↗

An accurate nonlinear finite element analysis and test correlation of a stiffened composite wing panel

State-of-the-art nonlinear finite element analysis techniques are evaluated by applying them to a realistic aircraft structural component. A wing panel from the V-22 tiltrotor aircraft is chosen because it is a typical modern aircraft structural component for which there is experimental data for comparison of results. From blueprints and drawings, a very detailed finite element model containing 2284 9-node Assumed Natural-Coordinate Strain elements was generated. A novel solution strategy which accounts for geometric nonlinearity through the use of corotating element reference frames and nonlinear strain-displacement relations is used to analyze this detailed model. Results from linear analyses using the same finite element model are presented in order to illustrate the advantages and costs of the nonlinear analysis as compared with the more traditional linear analysis.

Davis, D. D., Jr.↗

Modal Analysis and Model Correlation of the Mir Space Station

This paper will discuss on-orbit dynamic tests, modal analysis, and model refinement studies performed as part of the Mir Structural Dynamics Experiment (MiSDE). Mir is the Russian permanently manned Space Station whose construction first started in 1986. The MiSDE was sponsored by the NASA International Space Station (ISS) Phase 1 Office and was part of the Shuttle-Mir Risk Mitigation Experiment (RME). One of the main objectives for MiSDE is to demonstrate the feasibility of performing on-orbit modal testing on large space structures to extract modal parameters that will be used to correlate mathematical models. The experiment was performed over a one-year span on the Mir-alone and Mir with a Shuttle docked. A total of 45 test sessions were performed including: Shuttle and Mir thruster firings, Shuttle-Mir and Progress-Mir dockings, crew exercise and pushoffs, and ambient noise during night-to-day and day-to-night orbital transitions. Test data were recorded with a variety of existing and new instrumentation systems that included: the MiSDE Mir Auxiliary Sensor Unit (MASU), the Space Acceleration Measurement System (SAMS), the Russian Mir Structural Dynamic Measurement System (SDMS), the Mir and Shuttle Inertial Measurement Units (IMUs), and the Shuttle payload bay video cameras. Modal analysis was performed on the collected test data to extract modal parameters, i.e. frequencies, damping factors, and mode shapes. A special time-domain modal identification procedure was used on free-decay structural responses. The results from this study show that modal testing and analysis of large space structures is feasible within operational constraints. Model refinements were performed on both the Mir alone and the Shuttle-Mir mated configurations. The design sensitivity approach was used for refinement, which adjusts structural properties in order to match analytical and test modal parameters. To verify the refinement results, the analytical responses calculated using original and refined math models were compared with the measured responses. The results from this study show that the refined models predict more accurately the dynamics of the actual structure. The MiSDE test and analysis results provided the information and experience on test design, flight testing, and data analysis for the ISS and other future spacecraft, which are critical to the verification of analytical models and structural loads.

Kim, Hyoung M.↗