Open-Source Architecture for Multi-Party Update Verification for Data Acquisition Devices

Power grids are integral parts of modern daily life and are increasingly under cyberattack. Common software update processes for grid control devices rely on only one organization to provide verification. This paper roposes a multi-signature software update process to help better secure data acquisition devices from malicious actions by using standard cryptosystems such as TLS. A prototype system build on Linux and off-the-shelf hardware has shown successful update and attack prevention with our customized multi-party update software.

Newberg, Benjamin↗

Utility-Scale Operational Consequences for Solar Grid Services

This report delves into the critical aspects of grid services provided by solar inverter-based resources (IBRs), with an emphasis on the evolving landscape of microgrids, virtual power plants (VPPs), aggregators, and distributed energy resource management systems (DERMS). As the energy sector undergoes a transformative shift towards more decentralized and resilient grid architectures, understanding the multifaceted risks associated with these technologies becomes paramount. The report categorizes these risks into organizational, technical, and procedural domains, providing a thorough risk assessment framework that stakeholders can utilize to anticipate and mitigate potential issues. In addressing the increasing complexity of grid interconnections, the report highlights the importance of Cyber-Informed Engineering (CIE). By embedding engineering controls and cybersecurity measures into the early stages of system design, this approach aims to fortify grid infrastructure against emerging cyber threats. The analysis includes an exploration of best practices and strategies for integrating CIE principles to enhance grid security and resilience. To provide practical insights, the report conducts a detailed consequence analysis of various grid services and cyber mitigations that can be applied through the interconnection process. This analysis evaluates the potential impacts of different failure modes and vulnerabilities, offering a clear understanding of the consequences that could arise from disruptions within the energy grid. The findings are further enriched by a series of case studies that illustrate real-world scenarios and lessons learned from past incidents. Through this comprehensive examination of grid services and their criticality, the report aims to prepare industry professionals with the knowledge and tools necessary to navigate the complexities of modern energy systems. By providing a comprehensive approach that includes risk assessment, cybersecurity, and consequence analysis, solar stakeholders can more effectively guarantee the reliability, efficiency, and security of the energy grid.

14 SOLAR ENERGY↗

Manned maneuvering unit mission definition study. Volume 1: MMU applications analysis and performance requirements

Applications of Manned Maneuvering Units (MMU'S) to the space shuttle program are identified and described. The applications analyses included studies of the shuttle orbiter, orbiter subsystems, and both Sortie and Automated Payloads. Based on practicable MMU applications, general performance and control requirements for shuttle supporting maneuvering units are defined and compared to units evaluated on Skylab. The results of the MMU applications analyses and the general MMU performance and control requirements are presented. To describe a versatile utility-type maneuvering unit, conceptual designs of MMU support subsystems and ancillary equipment were prepared. Concepts for attaching and securing the MMU crewman to various vehicles, structure configurations, and rescue systems were developed. Concepts for ancillary provisions are reported.

Source record↗

Systems integration for the Kennedy Space Center (KSC) Robotics Applications Development Laboratory (RADL)

A laboratory for developing robotics technology for hazardous and repetitive Shuttle and payload processing activities is discussed. An overview of the computer hardware and software responsible for integrating the laboratory systems is given. The center's anthropomorphic robot is placed on a track allowing it to be moved to different stations. Various aspects of the laboratory equipment are described, including industrial robot arm control, smart systems integration, the supervisory computer, programmable process controller, real-time tracking controller, image processing hardware, and control display graphics. Topics of research include: automated loading and unloading of hypergolics for space vehicles and payloads; the use of mobile robotics for security, fire fighting, and hazardous spill operations; nondestructive testing for SRB joint and seal verification; Shuttle Orbiter radiator damage inspection; and Orbiter contour measurements. The possibility of expanding the laboratory in the future is examined.

Davis, V. Leon↗

Approach for Autonomous Control of Unmanned Aerial Vehicle Using Intelligent Agents for Knowledge Creation

This paper describes the development of a planned approach for Autonomous operation of an Unmanned Aerial Vehicle (UAV). A Hybrid approach will seek to provide Knowledge Generation through the application of Artificial Intelligence (AI) and Intelligent Agents (IA) for UAV control. The applications of several different types of AI techniques for flight are explored during this research effort. The research concentration is directed to the application of different AI methods within the UAV arena. By evaluating AI and biological system approaches. which include Expert Systems, Neural Networks. Intelligent Agents, Fuzzy Logic, and Complex Adaptive Systems, a new insight may be gained into the benefits of AI and CAS techniques applied to achieving true autonomous operation of these systems. Although flight systems were explored, the benefits should apply to many Unmanned Vehicles such as: Rovers. Ocean Explorers, Robots, and autonomous operation systems. A portion of the flight system is broken down into control agents that represent the intelligent agent approach used in AI. After the completion of a successful approach, a framework for applying an intelligent agent is presented. The initial results from simulation of a security agent for communication are presented.

Dufrene, Warren R., Jr.↗

U.S. Department of Energy Office of Science Biological and Environmental Research (BER) Brochure

The Biological and Environmental Research (BER) program advances fundamental research and scientific user facilities to support Department of Energy (DOE) missions in scientific discovery and innovation, energy security, and environmental responsibility. BER seeks to understand the biological, biogeochemical, and physical principles needed to predict a continuum of processes occurring across scales, from molecular and genomics-controlled mechanisms at the smallest scales to environmental and Earth system change at the largest scales.

54 ENVIRONMENTAL SCIENCES↗

IMAGINE BioSecurity: Mesocosm-Based Methods to Evaluate Biocontainment Strategies and Impact of Industrial Microbes Upon Native Ecosystems

Project Goals: The Integrative Modeling and Genome-scale Engineering for Biosystems Security (IMAGINE BioSecurity) SFA project seeks to establish an understanding of the behavior of engineered microbes in controlled versus environmental conditions to predictively devise new strategies for responding to biological escape. To this end, the IMAGINE Team has established a plant-soil mesocosm platform to track and quantify the fate of industrial microbes in environmental systems and assess the efficacy of biocontainment constraints upon genetically engineered microbe escape frequency and the impact of industrial microbes upon native ecological microbiomes. Abstract Text: Genetically modified industrial production microbes and their associated bioproducts have emerged as an integral component of a sustainable bioeconomy. However, the rapid development of these innovative technologies raises biosecurity concerns, namely, the risk of environmental escape. Thus, the realization of a bioeconomy hinges not only on the development and deployment of microbial production hosts, but also on the development of secure biosystems and biocontainment designs. Current laboratory-based biocontainment testing systems do not accurately reflect complexities found in natural environments, necessitating an environmentally relevant analysis pipeline that allows for the detection of rare escapees, the effect of associated bio-products, and the impact on native ecologies. To this end, we have developed an approach that utilizes soil mesocosms and integrated systems analyses to evaluate the efficacy of novel biocontainment strategies and to assess the impact of production systems upon terrestrial microbiome dynamics. We demonstrate the utility of this approach by modeling a contamination with industrial microbial chasses versus their biocontained counterparts. Here we demonstrate the broad utility of this system by highlighting findings from both strains of Saccharomyces cerevisiae that are contained with an inducible toxin anti-toxin system, and stains of Escherichia coli that are contained via genomic recoding. The resultant data demonstrate that this system has broad utility across diverse microbial chassis and biocontainment strategies, enables us to track the fate of our contaminating microbe with high sensitivity in the soil, as well as monitor broader impacts of the perturbation on the underlying soil system. The findings presented here support the use of this mesocosm-based approach to assess the environmental impact of industrial microbes and to validate biocontainment strategies.

BASIC BIOLOGICAL SCIENCES,INORGANIC, ORGANIC, PHYS↗

Cyber Secure Sensor Network for Fossil Fuel Power Generation Assets Monitoring

The energy sector is undergoing digital transformation which is to say more and more power generation assets have become automated and connected to the internet. The connected sensors can tap into plants to monitor the health of assets and manage fleets remotely. These are just some of the benefits digitalization is bringing to the power industry. Within a power plant, control systems are no longer concerned with one system or one piece of equipment, but rather whole fleet of assets inter-connected with smart sensors which have the function of continuously monitoring and transmitting real-time operational data to operators. These connected systems will form a part of the industrial internet of things (IIoT). The big data scenarios provide benefits of performing system prognostics and optimization which is a key selling point of power plant digitalization.

20 FOSSIL-FUELED POWER PLANTS↗

Universal Utility Data Exchange (UUDEX) – Security and Administration: Cybersecurity of Energy Delivery Systems (CEDS) Research and Development

A critical component of the Universal Utility Data Exchange (UUDEX) approach is the integrated security contained within its processing. This document describes how that security is designed and expected to be implemented by UUDEX Implementations (U-Implementations), including the UUDEX Server (U-Server) and UUDEX Clients (U-Clients). The UUDEX security hierarchy consists of three levels: 1. The UUDEX Instance (U-Instance) itself, which sits at the top of the hierarchy and contains the U-Server, the UUDEX Identity Authority (U-Identity Authority), and the UUDEX Administrator (U-Administrator) functions; 2. A group of one or more UUDEX Participants (U-Participants) that present “organizations” that participate in the U-Instance and contains the UUDEX Administrator Participant (U-U-Administrator Participant) function; 3. A group of one or more UUDEX Endpoints (U-Endpoints) that represent the individual UUDEX Publish Clients (U-Publish Client) responsible for supplying data to the U-Instance that is consumed by UUDEX Subscriber Clients (U-Subscriber Clients). U-Endpoints can be either autonomous devices that publish and subscribe data such as data exchange servers found in supervisory control and data acquisition and energy management systems, or they can be tied to users of applications that, for example, submit DOE OE-417 disturbance reports. U-Participants and U-Endpoints can be organized into UUDEX Groups (U-Groups). Any number of U-Participants or U-Endpoints can be members of a U-Group. A given U-Participant or U-Endpoint can be a member of multiple U-Groups, but a U-Group cannot contain other U-Groups. For example, a U-Group could be created to contain all U-Participant Transmission Operators within the purview of a Reliability Coordinator, and another U-Group could be created to contain all U-Participant Generator Operators within the purview of a Reliability Coordinator. U-Participants that are both Transmission Operators and Generator Operators would be members of both U-Groups. U-Participants, U-Endpoints, and U-Groups are used in the access control structures to provide access to individual UUDEX Subjects (U-Subjects). U-Groups are created by the U-Administrator and are managed by the U-Administrator or the designated U-Group Managers. U-Endpoints can be assigned UUDEX Roles (U-Roles) that can be used to further restrict access. U-Roles are assigned to individual U-Endpoints. For example, a U-Role of “Security Analyst” could be used to restrict which U-Endpoints can publish or subscribe security incident reports and vulnerability notifications, while a U-Role of “Transmission Planner” can be used to restrict which U-Endpoints can publish power system model updates. U-Role definitions are created by the U-Administrator, but the U-Roles are assigned to U-Endpoints by their respective UUDEX Participant Administrators (U-Participant Administrator). Because all information required to make security decisions is either included within the U-Endpoint’s X.509 digital certificate or stored in a datastore on the U-Server, all security decisions are performed and enforced within the U-Server. This reduces the complexity of the U-Client code and minimizes the chance for compromise of the integrity of the UUDEX security features.

97 MATHEMATICS AND COMPUTING↗

Distributed Intrusion Detection System using Semantic-based Rules for SCADA in Smart Grid

Cyber-physical system (CPS) security for the smart grid enables secure communication for the SCADA and wide-area measurement system data. Power utilities world-wide use various SCADA protocols, namely DNP3, Modbus, and IEC 61850, for the data exchanges across substation field devices, remote terminal units (RTUs), and control center applications. Adversaries may exploit compromised SCADA protocols for the reconnaissance, data exfiltration, vulnerability assessment, and injection of stealthy cyberattacks to affect power system operation. In this paper, we propose an efficient algorithm to generate robust rule sets. We integrate the rule sets into an intrusion detection system (IDS), which continuously monitors the DNP3 data traffic at a substation network and detects intrusions and anomalies in real-time. To enable CPS-aware wide-area situational awareness, we integrated the methodology into an open-source distributed-IDS (D-IDS) framework. The D-IDS facilitates central monitoring of the detected anomalies from the geographically distributed substations and to the control center. The proposed algorithm provides an optimal solution to detect network intrusions and abnormal behavior. Different types of IDS rules based on packet payload, packet flow, and time threshold are generated. Further, IDS testing and evaluation is performed with a set of rules in different sequences. The detection time is measured for different IDS rules, and the results are plotted. All the experiments are conducted at Power Cyber Lab, Iowa State University, for multiple power grid models. After successful testing and evaluation, knowledge and implementation are transferred to field deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

End-to-end Analytics for Grid Arch Design & All-hazard Assessment

Resiliency, reliability, and security of the next-generation smart grid depend upon leveraging advanced communication and computing technologies, integrating them with physical power systems, and developing real-time, fast, data-based applications to help in wide-area monitoring and control of the grid. Using a high sampling data rate from phasor measurement units (PMUs) to develop applications has opened the door to achieving the next-generation grid requirements. The North American Synchrophasor Initiative Network (NASPlnet) was developed in 2007-09 to create a standard and guide for PMU data exchanges. With the advancement in both networking and grid requirements, it is necessary to evaluate the performance of different NASPInet versions and their impact on applications. Therefore, we need a cyber-power cosimulation framework that supports very large-scale co-simulation capable of running in parallel, high-performance computing platforms and capturing real-life network behavior. This work presents a cyber-physical co-simulation testbed using NS3 to model the communication network, GridPACK to model the power grid, and HELICS as a co-simulation engine. Comparative analysis of latency in synchrophasor networks and a performance evaluation of a power system stabilizer application based on PMU data in an Institute of Electrical and Electronics Engineers 39-bus test system is presented using this co-simulation testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Speciation Correlations between Uranium and Iodine

The National Nuclear Security Administration’s Office of Conversion has been supporting development of molybdenum-99 production methods utilizing non-highly enriched uranium targets. One of the novel methods being considered is the use of an aqueous homogeneous subcritical system. Concerns about controlling potentially volatile radioiodine have led to efforts to characterize the iodine species in this system. This report examined the potential to characterize the chemical species of the iodine by correlating it with analyses of uranium, which is more ubiquitous in the target material and suitable for on-line monitoring. Direct measurement of the iodine species would be infeasible due to the difficulty in performing analyses. The use of chemometric modeling utilizing spectral analyses is viable for the uranium measurements, however, a better understanding of the radiolytic effects of neutrons and the corresponding relationship between uranium and iodine is required to correlate any measurements to iodine speciation.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

User-Focused Tools to Enhance IT/OT Cyber Resilience within the Power Grid

The power grid is undergoing several changes that are increasing its complexity as nexuses between electric-gas, transmission-distribution, and energy-communications continue to become increasingly critical. This system is heavily dependent on communication infrastructure and controls, and it relies on humans in operational technology (OT) and information technology (IT) roles to manage the increasing breadth, depth, and speed of data. Many technical challenges have presented themselves and will need to be addressed to provide reliable grid operations. With increased reliance on distributed controls and communication infrastructure, cybersecurity becomes an inherent requirement. When considering current cyber-physical security solutions for the power grid, one can notice a clear divide between information technology and operation technology networks. However, in real-life applications, these networks are interdependent. This work presents results of interviews with key utility cybersecurity personnel, analyzes the results, and makes recommendations towards solution of existing technical and operational challenges realized. Existing workflows are presented, wireframe interviews are discussed, and tool requirements are described. The existence of easy-to-implement solutions, based on existing energy management systems, highlight the potential for real-life applications.

cybersecurity, resilience, user-centered design, p↗

Hamilton: Flexible, Open Source $10 Wireless Sensor System for Energy Efficient Building Operation

Sensors for improving building performance are rapidly populating the market, driven in part by the drive to reduce greenhouse gas emissions resulting from energy production as well as improve the interior environment for healthy and more productive spaces. UC Berkeley has led wireless sensor development over the past 25 years (e.g., Telos mote), with the Hamilton (named after Alexander Hamilton on the US $10 bill) as the most recent. The Hamilton sensor was designed as a low-cost high-performance sensor that is modular and interoperable. The objective of the Hamilton project was to create, evaluate and establish the technological foundations for secure and easy to deploy building energy efficiency applications utilizing pervasive, low-cost wireless sensors integrated with traditional Building Management Systems (BMS), consumer-sector building components, and powerful data analytics. The project included iterative hardware design, incorporating a high-performance database (BTrDb, http://btrdb.io/), creating and iterating the development of secure data middleware (BOSSwave, WAVE/WAVEMQ), working with and pushing the development of an open-source tiny operating system RiotOS, and implementing and improving protocols such as Thread/OpenThread and TCP/IP. The hardware benefited from careful design to drive down the cost; the design included a System-on-a-Chip (SoC), chip antenna, single crystal and five passive components. Careful design of the operating system created a low-power design to enable a long life with small batteries. The hardware included several sensors: temperature, radiant temperature, relative humidity, magnetometer, accelerometer, and light, with an optional occupancy (Passive InfraRed) sensor. The project was the basis of several applications, both internal to the research team and other researchers and professionals at other institutions. Several applications used the sensor hardware as the basis for other complex devices. Other applications used the sensors to improve building performance through interoperating with the building Heating Ventilation and Air-Conditioning (HVAC) system, such as using occupancy and/or distributed temperature sensing to reduce HVAC zone energy while still providing thermal comfort and to reduce peak loads in small commercial buildings. We demonstrated cloud-based energy analytics, implemented a schedule and a Model Predictive Controller in a small commercial building to optimize HVAC energy, occupancy and electricity price. Initial integration of these technological innovations was performed through the creation of execution containers containing the WAVE agent and various driver, proxy, or building system function logic. The research added to the understanding of efficient sensor hardware, secure middleware, time-series data management (high performance database), efficient communication protocols, and interoperating with applications and building systems. The project showed the technical effectiveness and economic feasibility of creating a low-cost, modular, and easy-to-deploy sensor. Through conversations with multiple end users, the research team discovered that many customers wanted data management and services in addition to the sensors. HamiltonIOT developed packages of sensors, border router, and data services to provide a seamless “plug-and-play” sensor deployment. Some customers were willing to pay for higher quality sensors (such as light); some customers wanted a robust enclosure (waterproof).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Attack Surface of Wind Energy Technologies in the United States

Low cost, reliable electrical energy production from wind relies upon automation and control systems, arguably more so than traditional thermal generation. These same systems, however, can serve as the target of adversaries’ cyber-attacks. Idaho National Laboratory (INL), at the request of the Department of Energy’s (DOE’s) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) and Energy Efficiency and Renewable Energy’s (EERE’s) Wind Energy Technologies Office (WETO), evaluated a generalized wind plant architecture to understand the classes of potential threat actors and the vectors that could enable a cyber-attack. This evaluation explores the attack surface of a representative wind plant, identifying potential methods and vectors that an adversary could leverage to conduct a cyber-attack. Included in this assessment are some recommended mitigations and approaches. Each recommendation requires a full security evaluation, cost/benefit analysis, and risk analysis by each owner and operator.

17 WIND ENERGY↗

Cybersecurity Framework Profile for Electric Vehicle Extreme Fast Charging Infrastructure

This document is the Cybersecurity Framework Profile (Profile) developed for the Electric Vehicle Extreme Fast Charging (EV/XFC) ecosystem, including the four domains that relies on the ecosystem (i) Electric Vehicles (EV); (ii) Extreme Fast Charging (XFC); (iii) XFC Cloud or Third-Party Operations; and (iv) Utility and Building Networks. This Profile utilizes the NIST Cybersecurity Framework Version 1.1 and provides voluntary guidance to help relevant parties develop Profiles specific to their organization to understand, assess, and communicate their cybersecurity posture as a part of their risk management process. The Profile is intended to supplement, not replace, an existing risk management program or cybersecurity standards, regulations, and industry guidelines that are in current use by the EV/XFC industry.

33 ADVANCED PROPULSION SYSTEMS↗

Robust adaptive regulation without persistent excitation

A globally convergent adaptive regulator for minimum or nonminimum phase systems subject to bounded distrubances and unmodeled dynamics is presented. The control strategy is designed for a particular input-output representation obtained from the state space representation of the system. The leading coefficient of the new representation is the product of the observability and controllability matrices of the system. The controller scheme uses a Least Squares identification algorithm with a dead zone. The dead zone is chosen to obtain convergence properties on the estimates and on the covariance matrix as well. This allows the definition of modified estimates which secure well-conditioned matrices in the adaptive control law. Explicit bounds on the plant output are given.

Lozano-Leal, Rogelio↗

Deep Space Network information system architecture study

The purpose of this article is to describe an architecture for the Deep Space Network (DSN) information system in the years 2000-2010 and to provide guidelines for its evolution during the 1990s. The study scope is defined to be from the front-end areas at the antennas to the end users (spacecraft teams, principal investigators, archival storage systems, and non-NASA partners). The architectural vision provides guidance for major DSN implementation efforts during the next decade. A strong motivation for the study is an expected dramatic improvement in information-systems technologies, such as the following: computer processing, automation technology (including knowledge-based systems), networking and data transport, software and hardware engineering, and human-interface technology. The proposed Ground Information System has the following major features: unified architecture from the front-end area to the end user; open-systems standards to achieve interoperability; DSN production of level 0 data; delivery of level 0 data from the Deep Space Communications Complex, if desired; dedicated telemetry processors for each receiver; security against unauthorized access and errors; and highly automated monitor and control.