Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Coupling turbulent flow with blade aeroelastics and control modules in large-eddy simulation of utility-scale wind turbines

We present a large-eddy simulation framework capable of control co-design of large wind turbines, coupling the turbulent flow environment with blade aeroelastics and turbine controllers. The geometry and aerodynamics of the rotor blades and the turbine nacelle are parameterized using an actuator surface model. The baseline collective pitch control and individual pitch control (IPC) algorithms, consisting of a single-input, single-output proportional–integral controller and two integral controllers, respectively, are incorporated into the simulation framework. Furthermore, a second-order model based on the Euler–Bernoulli beam theory is implemented to describe the blade deformation. Simulations are carried out to investigate the impact of collective and individual pitch control strategies on the deflection of turbine blades. Our results show that the IPC reduces the blade tip deflection fluctuations in the out-of-plane direction, while the fluctuations of the blade tip deflection along the in-plane direction are barely affected by the IPC. Furthermore, the blade out-of-plane deformation fluctuation is underestimated by the one-way coupling approach compared to the two-way coupling approach. Furthermore, the findings of this study reveal the importance of advanced control systems in reducing the dynamic loads on wind turbine blades and underscore the potential of control co-design to reduce the levelized cost of wind energy.

42 ENGINEERING↗

All-optical control of charge transfer and interlayer excitons in transition metal dichalcogenide heterostructures

An all-optical approach to control interlayer charge transfer and interlayer exciton dynamics is demonstrated using transition metal dichalcogenide heterostructures of MoSe 2 /MoS 2 and MoSe 2 /WS 2 as examples. In the three-pulse pump-probe experiments, a control pulse injects photocarriers and produces an electric field due to the interlayer charge separation. A pump pulse excites new carriers and their dynamics under the influence of the control-injected carriers and field is time-resolved by measuring differential reflectance of a third probe pulse. In MoSe 2 /MoS 2 , the interlayer electron transfer time from MoSe 2 to MoS 2 decreases with increasing the control-injected carrier density and electric field. The dipole moment of the interlayer excitons is reduced by the control pulse, which can be utilized for ultrafast and all-optical control of interlayer excitons. The recombination of the interlayer excitons is enhanced by the control pulse, which increases the spatial overlap of the electron and hole wave functions. The effect of the control pulse on the interlayer excitons is confirmed in the MoSe 2 /WS 2 heterostructure, although its effect on the electron transfer time is not resolvable. Furthermore, these results reveal useful information to understand and control interlayer charge transfer dynamics and provide tools for ultrafast manipulation of electrons in van der Waals heterostructures.

36 MATERIALS SCIENCE↗

A Model-Free Frequency Control Approach for Diesel-Wind Powered Microgrids

Islanded microgrids usually consist of diesel generators and renewable energy sources (RES) to reduce the operating cost. Such microgrids have shown values for powering remote locations, but introduced unique challenges for frequency control of the grid due to the variability of renewable energy as well as the decoupled design of converter interface in RES. So, supportive control in RES becomes mandatory in such networks. This paper proposes a new dynamic control strategy, based on model-free control (MFC) approach, to support the primary frequency control of such islanded microgrids. The practical values of MFC have been discussed in various domains due to its control capability without modeling procedure and its efficient computation. In particular, we consider the diesel-wind system and the proposed MFC strategy is utilized as an online controller, which computes supplementary control signals for the rotor-side converter of the available wind turbine generators (WTGs). The calculated input signals allow WTGs to respond to frequency variations and improve the frequency response of the system. The controller is implemented and verified using the modified IEEE 33-bus full nonlinear model of the three-phase diesel-wind system in Simulink. Simulation results show the enhanced frequency response from the MFC strategy.

Park, Byungkwon↗

Grid Forming Control of PMSG-based Wind Turbines under Fault Conditions

Grid-forming control is widely envisioned as core technology ensuring stable operation of future power systems with increasing deployment of converter-interfaced renewable generation. However, research on grid forming control of wind turbines, especially under faults, is still in its early stages. In this context, this paper augments dual-port grid-forming control for type IV wind turbines with auxiliary controls to enable reliable fault ride through capabilities. In particular, the proposed control does not require a dc chopper or mode switching to grid-following control. Instead, energy-balancing dual-port GFM control is augmented with active rotor speed damping control and threshold virtual impedance for current limiting during faults. Different operating conditions of wind turbines are considered in a detailed electromagnetic transient simulation study to validate the effectiveness of the proposed control.

Lyu, Xue↗

Cooperative Model Predictive Control Scheme for Dispersed Smart Inverters at the Grid Edge

Growing number of distributed energy resources (DERs) requires cutting-edge control schemes to ensure uniform but not identical involvement of DERs to address rapid fluctuations on voltage of the grid clusters. Designing such control schemes for a grid with high penetration of DERs connected various clusters is complex and depends on physical configuration of the clusters themselves. This paper proposes a two-layered cooperative model predictive control scheme for fleet of dispersed smart inverters connected to a three-phase grid cluster located at the edge of a grid cluster. The upper layer of the controller ensures cooperative operation of fleet of smart inverters to perform voltage regulation and address voltage fluctuations in the grid cluster; while the lower level controller guarantees each individual inverter obeys the dictated references for active/reactive powers by the upper layer controller. In addition, the proposed twolayered controller has low voltage ride through (LVRT) capability to support the grid clusters during voltage sags. By employing the proposed control approach, the smart inverters will inject desired active/reactive powers based on circumstance of the entire cluster while guaranteeing proper power curtailment among the generation units. The control scheme is verified by simulation.

Fard, Amin Y.↗

Hierarchical Model-Free Transactional Control of Building Loads to Support Grid Services

A transition from generation on demand to consumption on demand is one of the solutions to overcome the many limitations associated with the higher penetration of renewable energy sources. Such a transition, however, requires a considerable amount of load flexibility in the demand side. Demand response (DR) programs can reveal and utilize this demand flexibility by enabling the participation of a large number of grid-interactive efficient buildings (GEB). Existing approaches on DR require significant modelling or training efforts, are computationally expensive, and do not guarantee the satisfaction of end users. To address the aforementioned limitations, this software code considers a scalable hierarchical model-free transactional control approach that incorporates elements of virtual battery, game theory, and model-free control (MFC) mechanisms. The developed approach separates the control mechanism into upper and lower levels. The MFC modulates the flexible GEB in the lower level with guaranteed thermal comfort of end users in response to the optimal pricing and power signals determined in the upper layer using a Stackelberg game integrated with aggregate virtual battery constraints. Additionally, the usage of MFC necessitates less burdensome computational and communication requirements, thus, it is easily deployable even on small, embedded devices. This software code enables the use of residential and small-size commercial buildings to offer a potentially substantial source of ancillary grid services that are currently underutilized. A hierarchical, model-free transactive building control provides a smooth interface between the grid service requests of utilities and the reliable control required by participating buildings. Model-free control, which supports distributed control architecture, will be a more scalable solution that can be deployed in neighborhood-size systems as well as individual buildings. The proposed approach contributes to the body of knowledge on two main aspects. First, it couples the MFC with the game-theoretic control and proposes a scalable model-free transactive control approach. MFC does not require any modeling effort or model training for the various building loads. This is very beneficial since deriving an accurate model for every single unit participating in DR programs and obtaining all the parameters about the units (e.g., thermal coefficients, standby losses) are infeasible. Also, MFC is computationally efficient, easily deployable even on small, embedded devices, and can be implemented in real time. Second, it integrates the concept of virtual battery into DR via the Stackelberg game. The concept of virtual battery enables efficient coordination and aggregation of a large number of flexible GEB with guaranteed thermal comfort of end users.

Olama, Mohammed [Oak Ridge National Lab. (ORNL), O↗

Automatic Tuner for the Step Sizes of Gradient-Based RT-OPF DERMS Control Systems [SWR-22-50]

Gradient-based controllers have parameters called step sizes that determine how sensitive its control actions are to received inputs. Finding a practical setting for a step size is important. If it is too small, the controller is ineffective by not reacting in a significant manor to its received inputs. On the other hand, if it is too large, the actions implemented by the controller may be excessive and cause the controlled system to become unstable. The main objective of the Automatic Tuner for the Step Sizes of Gradient-Based RT-OPF DERMS Control Systems is to speed up the implementation of gradient-based control schemes by automatically tuning its step sizes instead of having a practitioner spend considerable time doing the task manually. Only simple adjustments need to be made to the code of each controller with a step size to allow the addition of an individual automatic tuner. This can be applied to any RT-OPF based control for DER management.

Comden, Joshua↗

BOPTest As a Platform for Building Controls and Grid-Interactive Buildings Workforce Training

Building automation and controls are becoming increasingly complex with the emergence of Grid Integrated Efficient Buildings (GEBs) as well as new highly efficient sequences of operation and data-driven control schemes. However, there remains a significant gap in hands-on training opportunities for building operators and technicians to gain practical experience with advanced control systems in a low-risk environment. This paper presents BOPTEST (Building Optimization Performance Test) as a suitable platform for workforce training in building controls and GEB technologies. BOPTEST provides a suite of standardized building simulation test cases with a REST API, real-time control interfaces through BACnet, semantic models connecting users to building data, and built-in calculation of control metrics and performance indicators. The platform enables trainees to interact with virtual buildings using industry-standard protocols while learning how to implement and innovate control strategies. The training platform is designed to offer a structured and interactive learning experience for building engineers, helping them effectively develop, learn, and retain skills in fault identification, troubleshooting, and correction. The workflow is divided into three main phases: 1) Setup, 2) Exercise, and 3) Review, each comprising specific activities performed by either the instructor or the student. Initial pilot training sessions have yielded positive feedback from instructors and participants and demonstrates that BOPTEST effectively fills an industry need for a low-risk training resource via simulation of real building control systems, allowing trainees to gain practical experience before working in the field. The platform's ability to provide immediate performance feedback while maintaining familiar industry interfaces makes it particularly suitable for workforce development programs. This work provides a replicable model for leveraging building simulation in control education and training.

Paul, Lazlo↗

Hardware-In-the-Loop Benchmarking Setup for Phasor Based Control Validation

Phasor Based Control is a novel approach to controlling Distributed Energy Resources that aims at relieving various constraints that arise in the distribution grid. It is a two-layer control system with a supervisory control that coordinates distributed controllers to reach voltage phasor targets. The distributed controllers use local synchrophasor measurements and operate as feedback controllers. This control method is currently under development with several algorithms being under consideration for both the central and ditributed components. In this paper, we present the experimental setup that was prepared to prototype a hardware implementation and validate the control method in Hardware-In-the-Loop.

Baudette, Maxime↗

Crossing the Finish Line: Integration of Data-Driven Process Control for Maximization of Energy and Resource Efficiency in Advanced Water Resource Recovery Facilities

Improvements in process monitoring and control at water resource recovery facilities (WRRFs) could result in reductions in electricity consumption, chemical inputs, and greenhouse gas emissions, as well as improved energy recovery. Many current WRRF data collection, monitoring, and control approaches use 20th century process monitoring and control systems, which require large design safety factors to ensure reliability in the absence of more advanced, precise controls. Implementation of more modern data-driven control tools could lead to more efficient operations that provide intrinsic reliability with better overall process performance at full-scale. This presentation provides an overview of a recently initiated project "Crossing the Finish Line: Integration of Data-Driven Process Control for Maximization of Energy and Resource Efficiency in Advanced Water Resource Recovery Facilities" which will (1) develop and demonstrate data-driven process controls at full-scale facilities for five promising WRRF Applications (i.e., process technologies) that provide whole-plant approaches and offer substantial energy and resource recovery benefits, and (2) create a toolbox of new process control approaches and an implementation guide including five examples for application at utilities. The presentation also provides a detailed overview of the research approach and progress being made on one of the five Applications, namely Application 2: Biological Nutrient Removal (BNR): ammonium-based aeration control (ABAC) / ammonia vs. NOx (AvN) + partial denitration with anammox (PdNA), which is being implemented at Hampton Roads Sanitation District. This project is a collaboration of work being conducted by DC Water, Hampton Roads Sanitation District, Metro Water Recovery, University of Michigan, Northwestern University, US Military Academy - West Point, Black & Veatch, and Oak Ridge National Laboratory. Research partner: U.S. Department of Energy.

54 ENVIRONMENTAL SCIENCES↗

BOPTEST as a Platform for Building Controls and Grid-Interactive Buildings Workforce Training

Building automation and controls are becoming increasingly complex with the emergence of Grid Integrated Efficient Buildings (GEBs) as well as new highly efficient sequences of operation and data-driven control schemes. However, there remains a significant gap in hands-on training opportunities for building operators and technicians to gain practical experience with advanced control systems in a low-risk environment. This paper presents BOPTEST (Building Optimization Performance Test) as a suitable platform for workforce training in building controls and GEB technologies. BOPTEST provides a suite of standardized building simulation test cases with a REST API, real-time control interfaces through BACnet, semantic models connecting users to building data, and built-in calculation of control metrics and performance indicators. The platform enables trainees to interact with virtual buildings using industry-standard protocols while learning how to implement and innovate control strategies. The training platform is designed to offer a structured and interactive learning experience for building engineers, helping them effectively develop, learn, and retain skills in fault identification, troubleshooting, and correction. The workflow is divided into three main phases: 1) Setup, 2) Exercise, and 3) Review, each comprising specific activities performed by either the instructor or the student. Initial pilot training sessions have yielded positive feedback from instructors and participants and demonstrates that BOPTEST effectively fills an industry need for a low-risk training resource via simulation of real building control systems, allowing trainees to gain practical experience before working in the field. The platform's ability to provide immediate performance feedback while maintaining familiar industry interfaces makes it particularly suitable for workforce development programs. This work provides a replicable model for leveraging building simulation in control education and training.

Paul, Lazlo↗

Developing and Implementing New Waste Chemistry Controls for Hanford's Double-Shell Tanks - 20041

Waste chemistry controls for the Hanford double-shell tanks (DSTs) were established in the 1980's in response to tank failures caused by stress corrosion cracking (SCC) at the Savannah River Site (SRS). The controls were established based on a combination of SRS chemistry limits and corrosion testing results. Conditions in the Hanford DSTs have changed over time, with the temperature in the majority of the DSTs dropping below 50 deg. C. Testing indicated that the original chemistry control specification and SCC testing performed in 2010 did not protect against pitting corrosion mechanisms - what is believed to have caused the failure of tank 241-AY-102. New waste chemistry controls are necessary to protect the DSTs from both SCC and pitting corrosion. Savannah River National Laboratory (SRNL), with input from the Tank Integrity Expert Panel (TIEP) Corrosion Subgroup (CSG), performed a statistically based investigation of nitrate and halide ion induced pitting corrosion. The investigation was intended to develop a comprehensive waste chemistry envelope that minimizes the risk of both SCC and pitting caused by halide and nitrate ions. The waste chemistry envelope needed to be robust enough to address future waste retrieval and process changes which could significantly change the waste composition of the DSTs. The experimental design allowed the statistically significant ions and their effect on pitting corrosion to be determined. SRNL developed the 'pitting factor' which is an empirical relationship between the statistically significant inhibitive species (hydroxide, and nitrite), and pitting inducing species (nitrate, chloride, and fluoride). The coefficients are weighted factors that show the degree of influence the species have on the propensity for pitting. New waste chemistry control limits were recommended by SRNL, and concurred with by the TIEP CSG, that incorporated the pitting factor along with other limits. The controls developed to reduce the risk of pitting corrosion were evaluated to determine if they also protected against SCC. Hundreds of test results were reviewed and compared against the proposed limits. With the exception of one test result, instances where cracking was observed corresponded to chemistry that was outside of the proposed limits - indicating that the chemistry controls developed for pitting also adequately addressed SCC concerns. Existing tank composition estimates were evaluated against the new chemistry controls - three current tank chemistries are suspect, and may not meet the new chemistry control requirements. These included the interstitial liquid (liquid associated with solids) of DSTs 241-AN-102, 241-AN-106, 241-AN-107, and 241-AY-101. Measures are ongoing to evaluate the tanks with the suspect chemistry. These include varying combinations of: performing additional evaluations (history of use, modeling); DST specific laboratory testing; and, pursuing core samples of the DSTs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Maximum-impact Adversary Design for Network-based Control System: A Case Study on Grid-interactive Efficient Buildings

The Internet of Things (IoT) technology has dramatically improved the efficiency of today's building operation and management. By connecting controllable devices into a communication network, control signals can be easily passed to the devices, and operating status can be acquired from measurable ends with minimal effort. However, this all-connected configuration could also expose the network-based control system (NBCS) to malicious actions, such as cyberattacks. One of the common NBCSs is the building automation system. With the promotion of grid-interactive efficient buildings (GEBs), there has been increasing attention on securing the buildings from the network perspective. This research proposes a maximum-impact adversary design framework so that the adversary can provide the most adversarial impact on the controlled system while remaining stealthy. The proposed framework is numerically demonstrated on a network-based building energy and control system. The building energy system is built in a Modelica-based simulation environment and controlled by the state-of-the-art ASHRAE Guideline 36 control sequences. The control commands at the supervisory level, generated from the Guideline 36 controller, are assumed to be sent to local devices through communication networks using the BACnet protocol. Simulation results show that the proposed maximum-impact adversary on such a system can stealthily affect the building system's performance to its maximum extent. It is anticipated that results can be used by researchers and practitioners in the building automation industry to design efficient and robust cyber-attack detection algorithms, especially for stealthy attacks.

Chu, Mengyuan↗

Multi-Pressure Rail System Design with Variable Pressure Control Strategy

This paper presents the design and the control method of a Multiple Pressure Rail system (MPR) with a variable pressure control logic that allows minimization of throttling loss, therefore, increasing the overall fluid power actuation efficiency. An MPR system allows controlling hydraulic actuators with a pressure control logic, as opposed to traditional flow control logics which are well established in mobile applications. A proper setting of the number of pressure rails and the pressure level in each rail permits optimizing the system efficiency of an MPR solution. MPR systems have been recently proposed with different purposes, but seldom adopt variable pressure control strategies to manage the pressure variations in the rails. Moreover, the related past work attempts to maximize the energy recovery during overrunning load conditions. This paper, instead, addresses the case of an MPR system that handles a multitude of hydraulic functions without significant overrunning loads, as it occurs in many mobile applications such as in agriculture. The paper first presents the design alternatives considered for the MPR system, including the supply, the control valves, and the controller. Second, a dedicated test rig is developed to support experimental activities and validations of a lumped parameter model developed within this research to develop the MPR control strategy. The results describe the operating features of the proposed MPR solution. By considering the case of a traditional LS system, the paper results also show how system efficiency can be highly improved, with energy savings in the order of 49%

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Simulation Modeling and Control of a Desiccant Assisted Direct-expansion Air Handling Unit

Desirable built environments demand simultaneous regulation of thermal comfort and indoor air quality (IAQ) with energy-efficient operation of heating, ventilation and air conditioning (HV AC) systems, which involves controls of temperature, humidity and airborne contaminants simultaneously. This paper presents the efforts of dynamic modeling and initial development control strategy for a desiccant-assisted multi-functional air handling unit (AHU) coupled with a direct-expansion rooftop unit (RTU) system, which aims to achieve multiple functions for indoor environment conditioning with energy efficient control. The RTU-AHU system includes a desiccant wheel for dehumidification and a conceptual direct air capture (DAC) filtering device for CO2 regulation. A Modelica-based dynamic model is developed for this conceptual system, and a simple decentralized control strategy is designed, which combines a differential-enthalpy based AHU return-air ratio control, a demand-controlled ventilation, and supply-air temperature humidity control via the RTU and DW controls. The proposed control method is evaluated with the Modelica simulation model for a selected set of scenarios

Pan, Chao↗

Robust constrained tension control for high-precision roll-to-roll processes

Tension control is critical for maintaining good product quality in most roll-to-roll (R2R) production systems. Previous work has primarily focused on improving the disturbance rejection performance of tension controllers. Here, a robust linear parameter-varying model predictive control (LPV-MPC) scheme is designed to enhance the tension tracking performance of a pilot R2R system for deposition of materials used in flexible thin film applications. The performance of a tension controller may degrade due to disturbances associated with model uncertainties and the slowly-changing dynamics in R2R systems. We introduce a method that separately treats these two sources of disturbance. The controller utilizes an incremental model to eliminate the errors caused by the mismatch between the nominal model and the actual system. A tube-based MPC formulation combined with scheduled parameters adequately updates models and corrects for the time-varying dynamics. Constraints on the rated motor torque are incorporated in the MPC to maintain the controller reliability and avoid machine failures. We illustrate the operation of our control algorithm through simulation of an actual R2R system. The controller outperforms the benchmarks in terms of fast transient response and offset-free tension tracking. Furthermore, it also demonstrates immunity from variations due to parametric uncertainties.

42 ENGINEERING↗

High-speed feedback control of an oscillating magnetic helicity injector using a graphics processing unit

A real-time control system has been developed to control the amplitude, phase, and offset of bulk plasma parameters inside an oscillating magnetic helicity injector. Control software running entirely on an Nvidia Tesla P40 graphical processing unit is able to receive digitizer inputs and send response patterns to a Pulse Width Modulation (PWM) controller with a minimum control loop period of 12.8μs. With an input digitization rate of 10 MS/s, a three-parameter proportional integral differential controller is shown to be sufficient to inform the PWM controller to drive the desired oscillating plasma waveform with a frequency of 16.6 kHz that is located near the resonance of a coupled RLC circuit. In particular, the temporal phase of the injector waveform is held within 10 degrees of the target value. Control is demonstrated over the toroidal modal structure of the imposed magnetic perturbations of the helicity injection system, allowing a new class of discharges to be studied.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Prevalence and scalable control of localized networks

The ability to control network dynamics is essential for ensuring desirable functionality of many technological, biological, and social systems. Such systems often consist of a large number of network elements, and controlling large-scale networks remains challenging because the computation and communication requirements increase prohibitively fast with network size. Here, we introduce a notion of network locality that can be exploited to make the control of networks scalable, even when the dynamics are nonlinear. We show that network locality is captured by an information metric and is almost universally observed across real and model networks. In localized networks, the optimal control actions and system responses are both shown to be necessarily concentrated in small neighborhoods induced by the information metric. This allows us to develop localized algorithms for determining network controllability and optimizing the placement of driver nodes. This also allows us to develop a localized algorithm for designing local feedback controllers that approach the performance of the corresponding best global controllers, while incurring a computational cost orders-of-magnitude lower. Here, we validate the locality, performance, and efficiency of the algorithms in Kuramoto oscillator networks, as well as three large empirical networks: synchronization dynamics in the Eastern US power grid, epidemic spreading mediated by the global air-transportation network, and Alzheimer’s disease dynamics in a human brain network. Taken together, our results establish that large networks can be controlled with computation and communication costs comparable to those for small networks.

42 ENGINEERING↗