Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Contracting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Dynamic response of Mach 2.5 axisymmetric inlet with 40 percent supersonic internal area contraction

Results of experimental tests conducted on a supersonic, mixed compression, axisymmetric inlet are presented. The inlet is designed for operation at Mach 2.5 with a turbofan engine (TF-30). The inlet was terminated with either a choked-orifice plate or a long pipe with variable area choked exit plug. Frequency responses were obtained for selected static pressures in the diffuser. These pressures were selected as potential control signals for terminal shock control. Frequency responses were obtained for the Mach 2 and 2.5 conditions for different terminations. Responses also were obtained with and without cowl bleed. Internal disturbances were produced by sinusoidally varying the inlet overboard bypass doors at frequencies out to 100 hertz.

Baumbick, R. J.↗

Contraction kinetics of ventricular muscle from hibernating and nonhibernating mammals.

Temperature-dependent studies of excitability and tension-production kinetics were made on isolated trabecular strips from hibernating hamsters (HH), nonhibernating hamsters (CH), and from rats (R). The strips were electrically driven and isometric tension along with its first time derivative (dP/dt) were recorded. Excitabilities of both hamster tissues were greater than that of rat tissue from 5 to 38 C with HH greater than CH. Peak tension production followed the order of HH greater than CH greater than R at all temperatures below 24 C. Rat preparations showed an optimum peak tension production at about 31 C while HH and CH showed optima between 17 and 24 C. Times to maximal rates of tension rise showed significant variation. In this respect, the order of sensitivity to decreasing temperature was HH greater than CH greater than R.

South, F. E.↗

Terminal-shock and restart control of a Mach 2.5, axisymmetric, mixed compression inlet with 40 percent internal contraction

Results of experimental tests conducted on a supersonic, mixed-compression, axisymmetric inlet are presented. The inlet is designed for operation at Mach 2.5 with a turbofan engine (TF-30). The inlet was coupled to either a choked orifice plate or a long duct which had a variable-area choked exit plug. Closed-loop frequency responses of selected diffuser static pressures used in the terminal-shock control system are presented. Results are shown for Mach 2.5 conditions with the inlet coupled to either the choked orifice plate or the long duct. Inlet unstart-restart traces are also presented. High-response inlet bypass doors were used to generate an internal disturbance and also to achieve terminal-shock control.

Baumbick, R. J.↗

Forward slanted slot throat stability bypass to increase the stable airflow range of a Mach 2.5 inlet with 60 percent internal contraction

The results of an experimental investigation to increase the stable airflow operating range of a supersonic mixed-compression inlet are presented. Two forward-slanted slot stability-bypass entrance configurations were tested. In terms of diffuser-exit corrected airflow, a large inlet stable airflow range of 18.5 percent was obtained with the superior configuration if a constant pressure was maintained in the bypass plenum. Limited unstart angle-of-attack data are presented.

Shaw, R. J.↗

Distributed educated throat stability bypass to increase the stable airflow range of a Mach 2.5 inlet with 60-percent internal contraction

The results of an experimental investigation to increase the stable airflow operating range of a supersonic mixed-compression inlet are presented. A distributed educated throat stability-bypass entrance configuration was tested. In terms of diffuser-exit corrected airflow, a large inlet stable airflow range of about 16.1 percent was obtained if a constant pressure was maintained in the bypass plenum. Limited unstart angle of attack data are presented.

Shaw, R. J.↗

Throat stability-by pass systems to increase the stable airflow range of a Mach 2.5 inlet with 60-percent internal contraction

The results of an experimental investigation to increase the stable airflow range (without unstart) of a supersonic mixed-compression inlet are presented. Various stability bypass entrances were located on the cowl side of the inlet throat. The types of entrance were distributed porous (normal holes), forward-slanted slot, and distributed educated slots. A large stable airflow range was obtained for each entrance type if a constant pressure was maintained in the stability bypass plenum. The distributed porous entrance provided the largest stable airflow range. Inlet unstart angle of attack was unaffected by the entrances.

Mitchell, G. A.↗

Pressure activated stability-bypass-control valves to increase the stable airflow range of a Mach 2.5 inlet with 40 percent internal contraction

The throat of a Mach 2.5 inlet with a coldpipe termination was fitted with a stability-bypass system. The inlet stable airflow range provided by various stability-bypass entrance configurations in alternate combination with several stability-bypass exit controls was determined for both steady-state conditions and internal transient pulses. Transient results were also obtained for the inlet with a choke point at the diffuser exit. Instart angles of attack were determined for the various stability-bypass entrance configurations. The response of the inlet-coldpipe system to internal and external oscillating disturbances was determined. Poppet valves at the stability-bypass exit provided an inlet stable airflow range of 28 percent or greater at all static and transient conditions.

Mitchell, G. A.↗

Instantaneous distortion in a Mach 2.5, 40-percent-internal-contraction inlet and its effect on turbojet stall margin

An experimental wind tunnel investigation was conducted to determine the effects of time-variant distortions produced in a supersonic inlet on a J85-GE-13 turbojet engine. Results are presented principally in terms of instantaneous distortion amplitudes and total-pressure contours measured through compressor stall. They indicate that, although a time-averaged distortion may be far from a stall-inducing value, corresponding instantaneous distortion amplitudes can approach or exceed this value. Seven engine stall events were studied. In six of these events instantaneous distortion peaks of sufficient magnitude to cause stall were observed in the time period shortly before stall was detected.

Burstadt, P. L.↗

Lunar sample contracts

The major scientific accomplishments through 1971 are reported for the particle track studies of lunar samples. Results are discussed of nuclear track measurements by optical and electron microscopy, thermoluminescence, X-ray diffraction, and differential thermal analysis.

Walker, R. M.↗

Transonic off-design drag and performance of an axisymmetric inlet with 40 percent internal contraction on design

An experimental investigation determined the drag and pressure performance of an axisymmetric supersonic inlet when operated in the transonic speed range. The inlet configuration was derived from a Mach 2.5 mixed compression inlet design with assumed variable geometry. At typical engine airflows the drag coefficient varied from 0.057 to 0.192 when the Mach number changed from 0.80 to 1.27. The presence of a wing simulator resulted in a sizable increase in total drag at Mach 1.2. This interference drag, which is roughly a 0.1 increase in drag coefficient, originates equally from an increase in both additive and cowl pressure drag.

Woollett, R. R.↗

Space shuttle SRM interim contract, part 2

The characteristics of the solid rocket propellant for use with the space shuttle rocket engine are discussed. Design ramifications have created different web thicknesses and motor operating pressures which have necessitated small changes in the required propellant burning rate at 1,000 psia. However, the SRM burning rate remains well within the range demonstrated in the Poseidon and Minuteman first stage motors. Any change in propellant burning rate can be accomplished readily by a slight modification in the oxidizer particle size distribution. The ballistic and mechanical properties of the propellant remain unchanged from the baseline (Configuration 0).

Source record↗

Effects of N2O narcosis on the contraction and repayment of an oxygen debt

The oxygen deficit, oxygen debt, and the difference between them were measured in five male and three female subjects during and after exercise while breathing either air or a normoxic mixture containing 33% N2O and nitrogen. With the exception of a higher respiratory quotient at rest in N2O, there were no statistically significant differences for oxygen consumption, carbon dioxide production, expired gas volume, heart rate or blood lactate while breathing N2O during rest, exercise, or recovery. An appreciably, but not statistically, greater mean oxygen deficit was found in N2O along with a significantly greater mean oxygen debt; deficit-debt difference was unaffected by N2O. It was speculated that N2O narcosis did not affect the ability to utilize oxygen but that the response to the greater oxygen need of exercise may have been slowed with perhaps a concomitant greater depletion of stored high energy compounds.

Schatte, C. L.↗

Distortion in a full-scale bicone inlet with internal focused compression and 45 percent internal contraction

The distortion characteristics were investigated at the subsonic diffuser exit of a full-scale, Mach 2.5, axisymmetric, mixed compression inlet. Performance and steady-state distortion characteristics were obtained at zero and maximum angle of attack and during an inlet unstart-restart sequence. For the configuration with no cowl bleed, steady-state distortion P(max)P(min)P(bar) ranged from 0.10 for critical inlet operation at 0 deg angle-of-attack to 0.306 for supercritical inlet operation at 6.84 deg angle-of-attack. Vortex generators provided a 50 percent reduction in steady-state distortion for critical operation. Bleed has a smaller effect on steady-stated distortion.

Wasserbauer, J. F.↗

Performance of vortex generators in a Mach 2.5 low-bleed full scale 45-percent-internal-contraction axisymmetric inlet

Steady-state and dynamic flow characteristics associated with two sets of vortex generators having different mixing criteria were determined. The inlet performance with and without these vortex generators is presented. The vortex generators were successful in eliminating separation, increasing area-weighted total pressure recovery, and decreasing distortion. Transmission times obtained from cross-correlations of the wall static pressures and the diffuser exit total pressure showed no effect of the upstream flow characteristics on the diffuser exit pressures when generators were used. Without generators, separation occurred and the upstream pressure characteristics had immediate effects on the diffuser exit pressure characteristics.

Neumann, H. E.↗