A New Distributed Optimization for Community Microgrids Scheduling

This paper proposes a distributed optimization model for community microgrids considering the building thermal dynamics and customer comfort preference. The microgrid central controller (MCC) minimizes the total cost of operating the community microgrid, including fuel cost, purchasing cost, battery degradation cost and voluntary load shedding cost based on the customers' consumption, while the building energy management systems (BEMS) minimize their electricity bills as well as the cost associated with customer discomfort due to room temperature deviation from the set point. The BEMSs and the MCC exchange information on energy consumption and prices. When the optimization converges, the distributed generation scheduling, energy storage charging/discharging and customers' consumption as well as the energy prices are determined. In particular, we integrate the detailed thermal dynamic characteristics of buildings into the proposed model. The heating, ventilation and air-conditioning (HVAC) systems can be scheduled intelligently to reduce the electricity cost while maintaining the indoor temperature in the comfort range set by customers. Numerical simulation results show the effectiveness of proposed model.

alternating direction method of multipliers (ADMM)↗

Field Investigation of an Air-Source Cold Climate Heat Pump

In the U.S., there are approximately 2.6 million dwellings that use electricity for heating in cold and very cold regions with an annual energy consumption of 0.16 quads (0.17 EJ). A high performance cold climate heat pump (CCHP) would result in significant savings over current technologies (greater than 60% compared to electric resistance heating). We developed an air-source cold climate heat pump, which uses tandem compressors, with a single compressor rated for the building design cooling load, and running two compressors to provide, at -13 F (-25 C), 75% of rated heating capacity. The tandem compressors were optimized for heating operation and are able to tolerate discharge temperatures up to 280 F (138 C). A field investigation was conducted in the winter of 2015, in an occupied home in Ohio, USA. During the heating season, the seasonal COP was measured at 3.16, and the heat pump was able to operate down to -13 F (-25 C) and eliminate resistance heat use. The heat pump maintained an acceptable comfort level throughout the heating season. In comparison to a previous single-speed heat pump in the home, the CCHP demonstrated more than 40% energy savings in the peak heating load month. This paper illustrates the measured field performance, including compressor run time, frost/defrosting operations, distributions of building heating load and capacity delivery, comfort level, field measured COPs, etc.

Cold Climate Heat Pump↗

Optimal Sizing of Energy Storage for Community Microgrids Considering Building Thermal Dynamics

This paper proposes an optimization model for the optimal sizing of energy storage in community microgrids considering the building thermal dynamics and customer comfort preference. The proposed model minimizes the annualized cost of the community microgrid, including energy storage investment, purchased energy cost, demand charge, energy storage degradation cost, voluntary load shedding cost and the cost associated with customer discomfort due to room temperature deviation. The decision variables are the power and energy capacity of invested energy storage. In particular, we assume the heating, ventilation and air-conditioning (HVAC) systems can be scheduled intelligently by the microgrid central controller while maintaining the indoor temperature in the comfort range set by customers. For this purpose, the detailed thermal dynamic characteristics of buildings have been integrated into the optimization model. Numerical simulation shows significant cost reduction by the proposed model. The impacts of various costs on the optimal solution are investigated by sensitivity analysis.

Liu, Guodong↗

Heat pipe augmented passive solar heating system

A heat pipe augmented passive solar space heating system modulates the temperature inside a building structure, particular during heating seasons when the ambient temperature is below levels customarily associated with adequate room comfort, and in some embodiments comprises a solar absorber, a heat pipe surrounding wholly or partially by insulation, the heat pipe having three main sections which are an evaporator at one end proximal to the solar absorber, a condenser at the other end proximal to an interior room being heated, and a rubber adiabatic section between those. Additional aspects such as a mechanical valve in the adiabatic section are disclosed to limit unwanted thermal gains when cooling is needed because the ambient temperatures already exceed room comfort.

14 SOLAR ENERGY↗

Stochastic Model Predictive Control for Demand Response in a Home Energy Management System: Preprint

This paper presents a chance constrained, model predictive control (MPC) algorithm for demand response (DR) in a home energy management system (HEMS). The HEMS optimally schedules controllable appliances given user preferences such as thermal comfort and energy cost sensitivity, and available residentially-owned power sources such as photovoltaic (PV) generation and home battery systems. The proposed control architecture ensures both the DR event and indoor thermal comfort are satisfied with a high probability given the uncertainty in available PV generation and the outdoor temperature forecast. The uncertainties are incorporated into the MPC formulation using probabilistic constraints instead of computationally limiting sampling-based approaches. Simulation results for various user preferences and probabilistic model parameters show the effectiveness of the HEMS algorithm response to DR requests.

47 OTHER INSTRUMENTATION↗

Smart Ventilation Controls Boost Energy Efficiency and Indoor Air Quality

The average American household spends more than $2,200 a year on energy, and heating, ventilating, and air conditioning (HVAC) costs comprise nearly half of the bill. This is one reason why home builders focus on tightening building envelopes to save energy. Yet, limiting the potential for air exchange can negatively impact indoor air quality (IAQ). When outdoor conditions are most extreme during occupied periods, there may be comfort implications from continuing high levels of ventilation during associated weather events. This is true even with heat recovery. To mitigate risks, the Florida Solar Energy Center developed and tested approaches for “smart” ventilation system controls that enable more reliable design, installation, and operation to achieve desired IAQ while also minimizing energy and comfort impacts.

Building America↗

Smart Ventilation Controls Boost Energy Efficiency and Indoor Air Quality

The average American household spends more than $2,200 a year on energy, and heating, ventilating, and air conditioning (HVAC) costs comprise nearly half of the bill. This is one reason why home builders focus on tightening building envelopes to save energy. Yet, limiting the potential for air exchange can negatively impact indoor air quality (IAQ). When outdoor conditions are most extreme during occupied periods, there may be comfort implications from continuing high levels of ventilation during associated weather events. This is true even with heat recovery. To mitigate risks, the Florida Solar Energy Center developed and tested approaches for “smart” ventilation system controls that enable more reliable design, installation, and operation to achieve desired IAQ while also minimizing energy and comfort impacts.

30 DIRECT ENERGY CONVERSION↗

Adaptive Control for Residential HVAC Systems to Support Grid Services

In this paper, we propose an adaptive control strategy for residential buildings' heating ventilation and air conditioning (HVAC) systems to support grid services. The proposed control strategy captures the time-varying characteristics of the building and weather environments. It assigns to each building a local controller to maintain the indoor temperature within a desired comfort level, while the load aggregator allocates the assigned reference power provided by the distribution system operator to support a specific grid service, such as demand peak reduction, balancing supply and demand, and consuming the solar photovoltaic (PV) power locally. Simulation results are presented to verify the performance of the proposed control strategy in terms of maintaining the indoor temperatures of several buildings within the desired comfort bands while tracking the reference power profile. Also, a comparison with a recently developed model-free control strategy is presented.

Wu, Tumin↗

Occupancy-Driven Stochastic Decision Framework for Ranking Commercial Building Loads

For effective integration of building operations into the evolving demand response programs of the power grid, real-time decisions concerning the use of building appliances for grid services must excel on multiple criteria, ranging from the added value to occupants' comfort to the quality of the grid services. In this paper, we present a data-driven stochastic decision-support framework to dynamically rank load control alternatives in a commercial building, addressing the needs of multiple decision criteria (e.g. occupant comfort, grid service quality) under uncertainties in occupancy patterns. We adopt a stochastic multi-criteria decision algorithm recently applied to prioritize residential on/off loads, and extend it to i) consider complex load control decisions (e.g. dimming of lights, changing zone temperature set-points) in a commercial building; and ii) systematically integrate zonal occupancy patterns to better identify short-term (and time-varying) opportunities for grid service participation. We evaluate the performance of the proposed framework for curtailment of air-conditioning, lighting, and plug-loads in a multi-zone commercial office building for a range of design choices. With the help of a prototype system that integrates an interactive \textit{Data Analytics and Visualization} frontend we demonstrate a way for the building operators to monitor and change in real-time the available flexibility in energy consumption and to develop trust in the decision recommendations by interpreting the rationale behind the ranking.

Jain, Milan↗

Quantifying Occupant Health and Productivity for Deep Retrofits: Beyond Traditional IEQ Studies

As energy-efficiency standards for both new construction and existing building renovations become more stringent, further reductions become less tractable and more expensive. With increasing interest and rising investment in healthy built environments, integrating energy efficiency with improved occupant experience (i.e., health, comfort, and work performance) offers a new path to drive deep energy retrofits. However, the difficulty in quantifying and verifying health and productivity gains from building upgrades leads to lower valuation of human benefits in practice. Building codes and standards have progressive energy targets but often give minimum requirements to occupant health for factors such as ventilation and thermal comfort. State and federal laws in the United States that govern the energy service performance contract (ESPC) have no clear and consistent guidance on quantifying non-energy benefits and incorporating them into a formal cost-effectiveness analysis. This paper presents a methodology to measure a building’s potential performance improvement regarding occupant health based on existing evidence correlating IEQ to occupant outcomes. Health improvement measures are integrated with a building energy model to identify and measure the impact of holistic improvement strategies. The net present value of these measures is determined based on the investment costs required to attain those improvements, energy savings, and personnel gains. We will discuss results from one pilot building, which showed nearly $50 per square foot 20-year net present value using the integrated approach.

Keene, Kevin M.↗

Human-automated vehicle interactions

This dissertation is proposed to answer the question: how can the interactions between human and automated vehicles be used to improve the overall performance of automated driving technology? Multiple different modules in automated vehicles such as the perception, motion plan and motion control modules can potentially be benefitted from human-automated vehicle interactions. For perception module, the self-correction of faulty sensors can be achieved using human demonstration data. For motion plan and motion control modules, the performance of the low-level motion controller can be improved with the help of human demonstration, and the behavior of the motion planner can be improved using human intervention data during automated driving. Moreover, a better model for a human driver could improve the overall efficiency and comfort of vehicles in connected mixed traffic. In this dissertation, the technical research toward these goals has been completed and has resulted in several peer-reviewed publications. Optimization methods and model predictive control are used extensively to improve energy efficiency while maintaining safe and comfort driving. An inverse model predictive control (IMPC) method has been developed and it has been proven to be effective in modeling the motion of human driven vehicles. The proposed method has demonstrated its benefits in both connected automated highway driving and the bilateral adaptation of human driver and automated driving controller in human-in-the loop simulations. The proposed future research seeks to broaden the application of IMPC by considering a more comprehensive cost function design and applying it to more complex driving situations.

Guo, Longxiang↗

HUMAN-AUTOMATED VEHICLE INTERACTIONS

This dissertation is proposed to answer the question: how can the interactions between human and automated vehicles be used to improve the overall performance of automated driving technology? Multiple different modules in automated vehicles such as the perception, motion plan and motion control modules can potentially be benefitted from human-automated vehicle interactions. For perception module, the self-correction of faulty sensors can be achieved using human demonstration data. For motion plan and motion control modules, the performance of the low-level motion controller can be improved with the help of human demonstration, and the behavior of the motion planner can be improved using human intervention data during automated driving. Moreover, a better model for a human driver could improve the overall efficiency and comfort of vehicles in connected mixed traffic. In this dissertation, the technical research toward these goals has been completed and has resulted in several peer-reviewed publications. Optimization methods and model predictive control are used extensively to improve energy efficiency while maintaining safe and comfort driving. An inverse model predictive control (IMPC) method has been developed and it has been proven to be effective in modeling the motion of human driven vehicles. The proposed method has demonstrated its benefits in both connected automated highway driving and the bilateral adaptation of human driver and automated driving controller in human-in-the loop simulations. The proposed future research seeks to broaden the application of IMPC by considering a more comprehensive cost function design and applying it to more complex driving situations.

Guo, Longxiang↗

Long-term trends in connected thermostat performance

Internet-connected thermostats (CTs) control heating and cooling systems in about 30% of North American homes, and capture half of annual thermostat sales. In 2017 the U.S. Environmental Protection Agency created a program to certify the performance of ENERGY STAR® Connected Thermostats. To demonstrate compliance with energy-saving criteria, thermostat vendors must submit performance summaries for a representative sample of up to 1250 homes. Vendors must then re-submit results from a new, representative sample every six months in order to maintain their ENERGY STAR certification. This procedure has created a unique record of each thermostat’s long-term performance in response to changes in weather, customer demographics, building stock, and algorithms. Our analysis covers submissions from 13 different vendors, who submitted data up to 7 times over four years. We found that these semi-annual samples generated relatively stable trends for comfort temperatures and Heating, Ventilating and Air Conditioning (HVAC) runtimes over the study period. However, some vendors achieved consistently more energy-conserving comfort temperatures and shorter HVAC runtimes than others. The most recent submission runtimes averaged 700 hours for heating and 1,300 hours for cooling, but some vendors achieved runtimes as much as 17% below the mean. This implies lower energy consumption is due in large part to more successful algorithms and control strategies used by those vendors.

Meier, Alan↗

What does it take to “see” air leakage through a building envelope?

Unwanted air leakage in buildings can cause health and comfort issues for the building occupants and contribute to rot and mold growth in building materials. Leakage also contributes to unnecessary energy consumption ~4 quads (1172 TWh) per year in the buildings sector in the United States. Finding and repairing leaks through the building envelope can improve the energy efficiency, comfort, air-quality, and moisture durability of the building stock. Typical methods of locating air leakage, such as infrared imaging or smoke tracing, rely on concurrent blower door operation which also measures the total leakage rate of the building. These methods can be disruptive to occupants and can’t measure the contribution of individual leaks to prioritize sealing efforts. ORNL is working on a refraction-based fluid flow imaging technique that can measure the leakage rate of individual leaks from the outside of the building. The working principle of this device is based on the refraction of light caused by the exfiltration because there is a small difference in density between the exfiltration and ambient air. We will discuss the operation of the air leak detector and key variables that affect its performance. We will also present preliminary results showing the visualization capability of this new air leak detector under different conditions. Experiments were completed with different claddings, air temperatures, and lighting conditions.

Boudreaux, Philip↗

Two-point and multiple-point spot heating and cooling

Apparatus and methods for producing thermal comfort using two point or multipoint heating or cooling that is applied to portion of a human body part to produce a warm or cool sensation over a larger area than that where the heating or cooling is directly applied. The body is induced to heat or cool itself by adjusting its neutral temperature setpoints. Increased warming perception from two-point, multipoint, and switching point stimulation causes downward adaptation in the neutral skin temperature of the user. Because spot heating and cooling sources operate at higher temperature differences from the skin than do area sources, they create a stronger perceived thermal sensation for the same power consumption. Point heating or cooling, rather than whole-area heating, can result in power savings and cost savings while improving occupant comfort.

Arens, Edward↗

The Telbot master-arm

It is the weight lifter with maximum flexibility: The TELBOT provides high capacity and infinite rotary motion across all axes. Special jobs call for a special robot: The TELBOT from Waelischmiller Engineering. The TELBOT particularly shows its strength in places where human operators cannot work and heavy work has to be done. For example in the nuclear industry or chemical plants. The TELBOT is a multifunctional, modular and automated robotic system with unique characteristics: no cable in or on the TELBOT-arms for unlimited, fast and precise arm motions as well as maximum efficiency and highest comfort; smooth, sealed arm and joint bodies ensure maximum radiation resistance, making the TELBOT robot the perfect helper for the nuclear sector; the TELBOT can not only be utilised for an extremely long time but is also maintenance-free and easy to decontaminate. They therefore represent an investment that will still pay out in 30 years time; sophisticated engineering skill is apparent not least in the slim design with no loss of high capacity; tools can be remotely controlled with extreme precision and the high repeat accuracy and simple implementation of complex processes ensure trouble-free and intuitive operation; programmed motion sequences bring with them noticeably comfortable and speedy operation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Simple Panel System to Overcome Interface Challenges for Retrofits: Preprint

Retrofitting buildings is usually an expensive and labor-intensive process. Weatherization measures can improve comfort and energy affordability to some extent, but deep energy retrofits are needed to optimize performance and comfort, and to achieve significant energy cost savings. Barriers to deep energy retrofits include a limited supply of skilled labor, different building types, planning complexity, split incentives, and a long or non-existent ROI horizon. The "Simple Panel System" (SPS) workflow developed and demonstrated in this effort streamlines deep energy retrofits by applying advanced site capture, machine learning, and mixed reality to panelized construction. The result is a one-stop, product-independent solution for rapidly scalable retrofits with the potential to reduce construction time and project costs by 50%. Soft costs are reduced by more than 66%, total costs by more than 50%, and field construction time by more than 50% - not to mention the reduction in construction waste, improvement in working conditions, and the ability to scale without an influx of skilled labor. This paper presents the SPS and the preliminary results and findings from the pilot project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Global Cooling: Policies to Cool the World and Offset Global Warming from CO2 Using Reflective Roofs and Pavements

Increasing the solar reflectance of the urban surface reduce its solar heat gain, lowers its temperatures, and decreases its outflow of thermal infrared radiation into the atmosphere. This process of 'negative radiative forcing' can help counter the effects of global warming. In addition, cool roofs reduce cooling-energy use in air conditioned buildings and increase comfort in unconditioned buildings; and cool roofs and cool pavements mitigate summer urban heat islands, improving outdoor air quality and comfort. Installing cool roofs and cool pavements in cities worldwide is a compelling win-win-win activity that can be undertaken immediately, outside of international negotiations to cap CO{sub 2} emissions. We propose an international campaign to use solar reflective materials when roofs and pavements are built or resurfaced in temperate and tropical regions.

14 SOLAR ENERGY↗