Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Color”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

SeaDAS Tutorial: Applying Color Ramps to ACOLITE Turbidity Products

This tutorial provides step-by-step instructions for applying color ramps and legends to ACOLITE turbidity products derived from the Dogliotti turbidity equation. The user inputs their own image and the resulting product is a colorized visualization of turbidity. This visualization provides the user with a better understanding of turbidity in their image and can be used to support further analysis of turbidity patterns.

Kelly Young↗

Advances in the Ocean Color Component of the Aerosol Robotic Network (AERONET-OC)

The Ocean Color Component of the Aerosol Robotic Network(AERONET-OC) supports activities related to ocean color such as validation of satellite data products, assessment of atmospheric correction schemes, and evaluation of bio-optical models through globally distributed standardized measurements of water-leaving radiance and aerosol optical depth. In view of duly assisting the AERONET-OC data user community, this work (i) summarizes the latest investigations on a number of scientific issues related to above-water radiometry, (ii) emphasizes the network expansion that from 2002 until the end of 2020 integrated 31 effective measurement sites, (iii) shows the equivalence of data product accuracy across sites and time for measurements performed with different instrument series, (iv) illustrates the variety of water types represented by the network sites ensuring validation activities across a diversity of observation conditions, and (v) documents the availability of water-leaving radiance data corrected for bidirectional effects by applying a method specifically developed for chlorophyll-a-dominated waters and an alternative one that is likely suitable for any water type.

In situ oceanic observations↗

Overview of NASA's Ocean Color Instrument Solar Calibration Architecture, Pre-Launch Tests and Preliminary On-Orbit Results

Launched in February 2024, the PACE mission represents NASA’s next investment in ocean biology, clouds, and aerosol data records. A key feature of PACE is the inclusion of an advanced satellite radiometer known as the Ocean Color Instrument (OCI), a global mapping radiometer that combines multispectral and hyperspectral remote sensing. Like its predecessors, OCI will provide two day global coverage of TOA radiances. Unlike its predecessors, OCI will cover a spectral range from 340nm to 2260nm. Below 900nm, OCI will include two spectrometers that continuously span the ultraviolet to 600nm and 600nm to near-infrared spectral regions to provide hyperspectral radiances sampled every 2.5 nm, with a bandwidth of 5 nm for each channel. Wavelengths above 900nm are measured in seven discrete multispectral bands of varying bandwidths, six of which are at similar wavelengths to those on heritage missions to support both atmospheric and ocean color applications. Nominal spatial resolution is similar to the SeaWiFS instrument with 1050 m at nadir. As for SeaWiFS, the pixel size increases due to a ~20 degree tilt and as a function of scan angle. Variations in the radiometric sensitivity of each OCI channel over time will be monitored by solar diffuser measurements for short term instrument gain adjustments and independent lunar measurements for trend adjustments of long time periods, similar to the approach employed for the VIIRS instrument [4]. The OCI flight-unit was built at NASA’s Goddard Space Flight Center. At the time of this writing, OCI has completed on-orbit commissioning activities and normal science operations have begun. A key aspect of the OCI architecture is the capability to trend absolute and relative calibration changes over the course of mission life with solar calibration. Every 24 hours, the PACE spacecraft performs an inertial hold as the ground track nears the North Pole which orients a Quasi-Volume Diffuser (QVD) mounted on OCI towards the sun. By knowing the irradiance of the sun and the reflectivity of the target, the absolute radiance at the input to the OCI aperture can be computed as OCI scans the target. The allowable absolute uncertainty budget for each solar calibration measurement is 1.6% 1-sigma below 900nm at beginning of life (BOL) and the allowable relative uncertainty budget is ~0.26% 1-sigma. The Solar Calibration Assembly (SCA) consists of three targets selectable via a single mechanism which also opens a door. The targets consist of a Daily Bright Target (DBT), Monthly Bright Target (MBT), and Daily Dim Target (DDT). The bright targets are quartz QVDs with the monthly target being used to track the degradation of the daily target. The dim target is used to track CCD linearity using Progressive Time-Delay Integration (PTDI). A composite baffle is attached to the SCA housing aperture to block Earth shine and stray light from the spacecraft. The SCA assembly is mounted to a view port ~90° from OCI nadir. This paper provides an overview of driving solar calibration requirements, error-budgets and early trade studies which drove the solar calibration assembly (SCA) architecture and on-orbit maneuver. Measurements of the diffuser Bidirectional Reflectance Distribution Function (BRDF) at TNO, Netherlands and GSFC are briefly described. Optical modelling and test results at the sub-system and instrument level are included. Finally, preliminary measurements on-orbit are compared to pre-launch predictions.

Joseph J Knuble↗

A color Schlieren system

Color schlieren photographic system for analysis of complex compressible fluid flows

FLUID MECHANICS↗

Real-time three-dimensional color doppler evaluation of the flow convergence zone for quantification of mitral regurgitation: Validation experimental animal study and initial clinical experience

BACKGROUND: Pitfalls of the flow convergence (FC) method, including 2-dimensional imaging of the 3-dimensional (3D) geometry of the FC surface, can lead to erroneous quantification of mitral regurgitation (MR). This limitation may be mitigated by the use of real-time 3D color Doppler echocardiography (CE). Our objective was to validate a real-time 3D navigation method for MR quantification. METHODS: In 12 sheep with surgically induced chronic MR, 37 different hemodynamic conditions were studied with real-time 3DCE. Using real-time 3D navigation, the radius of the largest hemispherical FC zone was located and measured. MR volume was quantified according to the FC method after observing the shape of FC in 3D space. Aortic and mitral electromagnetic flow probes and meters were balanced against each other to determine reference MR volume. As an initial clinical application study, 22 patients with chronic MR were also studied with this real-time 3DCE-FC method. Left ventricular (LV) outflow tract automated cardiac flow measurement (Toshiba Corp, Tokyo, Japan) and real-time 3D LV stroke volume were used to quantify the reference MR volume (MR volume = 3DLV stroke volume - automated cardiac flow measurement). RESULTS: In the sheep model, a good correlation and agreement was seen between MR volume by real-time 3DCE and electromagnetic (y = 0.77x + 1.48, r = 0.87, P <.001, delta = -0.91 +/- 2.65 mL). In patients, real-time 3DCE-derived MR volume also showed a good correlation and agreement with the reference method (y = 0.89x - 0.38, r = 0.93, P <.001, delta = -4.8 +/- 7.6 mL). CONCLUSIONS: real-time 3DCE can capture the entire FC image, permitting geometrical recognition of the FC zone geometry and reliable MR quantification.

Validation Studies↗

Comparison of DNA fragmentation and color thresholding for objective quantitation of apoptotic cells

Apoptosis is a process of cell death characterized by distinctive morphological changes and fragmentation of cellular DNA. Using video imaging and color thresholding techniques, we objectively quantitated the number of cultured CD4+ T-lymphoblastoid cells (HUT78 cells, RH9 subclone) displaying morphological signs of apoptosis before and after exposure to gamma-irradiation. The numbers of apoptotic cells measured by objective video imaging techniques were compared to numbers of apoptotic cells measured in the same samples by sensitive apoptotic assays that quantitate DNA fragmentation. DNA fragmentation assays gave consistently higher values compared with the video imaging assays that measured morphological changes associated with apoptosis. These results suggest that substantial DNA fragmentation can precede or occur in the absence of the morphological changes which are associated with apoptosis in gamma-irradiated RH9 cells.

Non-NASA Center↗

Pragmatic Approach to Device-Independent Color

JPL has been producing images of planetary bodies for over 30 years. The results of an effort to implement device-independent color on three types of devices are described. The goal is to produce near the same eye-brain response when the observer views the image produced by each device under the correct lighting conditions. The procedure used to calibrate and obtain each device profile is described.

device-independent color remote imaging reproducti↗