Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Calorimeters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Heating effects on jack pine pyrogenic organic matter properties from a pyrocosm study in 2022

This dataset contains data associated with the preprint “Fire removes preexisting pyrogenic organic matter from the ecosystem through the mechanisms of both direct combustion and increasing mineralizability” (Luo et al., 2025b), which is the complementary study to the published paper “Reburning pyrogenic organic matter: a laboratory method for dosing dynamic heat fluxes from above” (Luo et al., 2025a). We designed a full-factorial experiment with different burial depths of jack pine (Pinus banksiana Lamb) pyrogenic organic matter (PyOM) (Surface, 1 cm, and 5 cm) and different heat-flux profiles (High, Low, and Control) to examine how subsequent fires affect the properties of preexisting PyOM. We measured total carbon (C), pH, dissolved organic carbon (DOC), dissolved inorganic carbon (DIC), and mineralized C (as CO₂-C, from a 12-week incubation).We found that high heat flux and/or surface placement resulted in substantial direct C losses through combustion. Intermediate heat exposure produced both combustion losses and increases in DOC and mineralizability, which may have complex long-term implications: an increased dissolved fraction of PyOM may promote downward transport into mineral soils and potentially contribute to deeper, longer-term C storage, but it may also make PyOM more susceptible to microbial decomposition. Under the lowest heat flux and deepest burial, most PyOM was retained, and changes in DOC and C mineralization were minimal. Finally, PyOM pH, an important chemical property, decreased under low-temperature heating but increased under higher temperatures.We uploaded pH data for all samples (“pH_of_all_samples.csv”); pH and temperature-related data (peak temperature and degree hours) for samples in High and Low heat-flux treatments (“pH_vs_peakT_and_degree_hours_only_for_heated_samples.csv”); total C data (“CN_pct_C_stock_C_loss_in_samples.csv”); DOC and DIC data (“doc_dic.csv”); and mineralized C (CO₂-C) data (“CO2-C_all_original.csv”). Additional details can be found in the Methods & Sampling section.All datasets uploaded to ESS-DIVE are clearly labeled, cleaned, and include both raw and derived data, ready for reuse in other analyses. All analysis code and raw datasets are also available on GitHub: https://github.com/MengmengLuo/Fire-removes-preexisting-pyrogenic-organic-matter-from-the-ecosystem.

54 ENVIRONMENTAL SCIENCES↗

Self-absorption and Phonon Pulse Shape Discrimination in Scintillating Bolometers

In this work, we show that self-absorption of photons in scintillating bolometers can differentiate phonon pulse shapes between α (or nuclear recoil) and β/γ signals. This enables phonon pulse shape discrimination for particle identification. We establish a detector signal model that includes self-absorption and compare the simulated phonon pulse shapes with previously reported experimental results. The model predicts increase in pulse shape difference at higher self-absorption. Based on this result, we propose a new design of scintillating bolometers using 4π light reflectors for maximized self-absorption and only a single phonon readout, instead of light detectors that are typically employed for particle discrimination in scintillating bolometers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The CUORE Detector and Results

The cryogenic underground observatory for rare events (CUORE) is a cryogenic experiment searching for neutrinoless double beta decay (0νββ) of 130 Te. The detector consists of an array of 988TeO 2 crystals arranged in a compact cylindrical structure of 19 towers. We report the CUORE initial operations and optimization campaigns. We then present the CUORE results on 0νββ and 2νββ decay of 130 Te obtained from the analysis of the physics data acquired in 2017.

0vββ↗

Latest Results from the CUORE Experiment

Abstract The Cryogenic Underground Observatory for Rare Events (CUORE) is the first cryogenic experiment searching for $$0\nu \beta \beta $$ 0 ν β β decay that has been able to reach the one-tonne mass scale. The detector, located at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, consists of an array of 988 $${\mathrm{TeO}}_{2}$$ TeO 2 crystals arranged in a compact cylindrical structure of 19 towers. CUORE began its first physics data run in 2017 at a base temperature of about 10 mK and in April 2021 released its $$3{\mathrm{rd}}$$ 3 rd result of the search for $$0\nu \beta \beta $$ 0 ν β β , corresponding to a tonne-year of $$\mathrm{TeO}_{2}$$ TeO 2 exposure. This is the largest amount of data ever acquired with a solid state detector and the most sensitive measurement of $$0\nu \beta \beta $$ 0 ν β β decay in $${}^{130}\mathrm{Te}$$ 130 Te ever conducted . We present the current status of CUORE search for $$0\nu \beta \beta $$ 0 ν β β with the updated statistics of one tonne-yr. We finally give an update of the CUORE background model and the measurement of the $${}^{130}\mathrm{Te}$$ 130 Te $$2\nu \beta \beta $$ 2 ν β β decay half-life and decay to excited states of $${}^{130}\mathrm{Xe}$$ 130 Xe , studies performed using an exposure of 300.7 kg yr.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Properties of Low Tc AlMn TES

Low Tc AlMn transition-edge sensors (TESs) have been developed as sensitive thermometers for the Q-Array, which will use superconducting targets to measure the coherent elastic neutrino nucleus scattering spectrum in the RICOCHET experiment. The TESs are made of manganese-doped aluminum with a titanium and gold antioxidation layer. A prototype TES thermometer consists of two TESs in parallel, an input gold pad in metallic contact with the TESs and an output gold pad and gold thermal link meanders, which are each designed to control the flow of heat through the TESs. We have fabricated and measured low TC AlMn TES chips with or without thermal flow control structures. We present TC measurements of the TESs after the initial fabrication and further TC tuning by re-heating and summarize the thermal property studies of the prototype TES thermometer by measuring I-V curves and complex impedance.

Coherent elastic neutrino nucleus scattering, Cryo↗

Advanced Energy Scale Correction Techniques for the X-ray Transition Edge Sensors of the Athena mission

The X-ray Integral Field Unit (X-IFU) onboard the future European X-ray telescope Athena will be the first space instrument carrying an array of more than a thousand transition edge sensors. One of the key challenges of the X-IFU is the measurement of narrow X-ray atomic lines to determine velocity shifts at an unprecedented level of accuracy. For this reason, the energy scale of the instrument needs to be known with extreme accuracy, of 0.4 eV (1σ) up to 7 keV. The energy scale will be measured on the ground through a dedicated calibration campaign using fiducial X-ray sources. Though calibrated, the energy scale is extremely sensitive to the environmental conditions around the TES array, and drifts in the readout chain electronics. Uncorrected, the energy scale can naturally drift up to hundreds of eVs. Changes of the TES gain will be monitored via onboard X-ray calibration sources, and the energy scale will be corrected either per pixel, or within a small groups of pixels. Although simulations show that a 0.4 eV level can be achieved, the very high accuracy required by the X-IFU calls for experimental validation. A dedicated measurement campaign has been performed by NASA Goddard Space Flight Center to characterize the energy scale of a prototype kilo-pixel array of X-IFU-representative TESs. The analysis of the data demonstrated the ability to correct for various drifts using two fiducial lines to track the temporal gain variation. In this paper, we propose to extend this study on the same data set by investigating multi-parameter correction techniques based on both the pulse-height of the fiducial line and the prepulse baseline level, using the knowledge of the TES energy scale at reference temperature/magnetic field set points acquired on the ground. Investigations on the co-adding of pixels to perform a joint correction over pools of pixels is also explored.

79 ASTRONOMY AND ASTROPHYSICS↗

Single electron–hole pair sensitive silicon detector with surface event discrimination

Here, we demonstrate single electron-hole pair resolution in a single-sided, contact-free 1 cm$^2$ by 1 mm thick Si crystal operated at 48 mK, with a baseline energy resolution of 3 eV. This crystal can be operated at voltages in excess of $\pm50$ V, resulting in a measured charge resolution of 0.06 electron-hole pairs. The high aluminum coverage ($\sim$70%) of this device allows for the discrimination of surface events and separation of events occurring near the center of the detector from those near the edge. We use this discrimination ability to show that dark events seen in previous detectors of a similar design are likely dominated by charge leakage along the side wall of the device. We saw only a small reduction in dark event rate with this biasing scheme, further suggesting that sidewall and edge-dominated processes are responsible for the majority of these events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CUORE opens the door to tonne-scale cryogenics experiments

The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution – comparable to semiconductor detectors – and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require ever greater exposures, which has driven them to ever larger cryogenic detectors, with the CUORE experiment being the first to reach a tonne-scale, mK-cooled, experimental mass. CUORE, designed to search for neutrinoless double beta decay, has been operational since 2017 at a temperature of about 10 mK. This result has been attained by the use of an unprecedentedly large cryogenic infrastructure called the CUORE cryostat: conceived, designed and commissioned for this purpose. In this article the main characteristics and features of the cryogenic facility developed for the CUORE experiment are highlighted. In this work, a brief introduction of the evolution of the field and of the past cryogenic facilities are given. The motivation behind the design and development of the CUORE cryogenic facility is detailed as are the steps taken toward realization, commissioning, and operation of the CUORE cryostat. The major challenges overcome by the collaboration and the solutions implemented throughout the building of the cryogenic facility will be discussed along with the potential improvements for future facilities. The success of CUORE has opened the door to a new generation of large-scale cryogenic facilities in numerous fields of science. Broader implications of the incredible feat achieved by the CUORE collaboration on the future cryogenic facilities in various fields ranging from neutrino and dark matter experiments to quantum computing will be examined.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermophysical Properties of NaCl–UCl 3 –PuCl 3 Molten Salts: A Combined Computational and Experimental Study

Actinide-bearing molten salts for use as fuels are an essential part of next generation molten salt reactors. Yet, numerous multicomponent salt mixtures are underdeveloped or have not been investigated. Here, this study, based on a combination of experimental and modeling techniques, is dedicated to determining and understanding a variety of properties of the ternary system of NaCl–UCl 3 –PuCl 3 , which represents a scenario for burnup of NaCl–UCl 3 fuel, at two compositions (∼10 and 5 mol % PuCl 3 in eutectic NaCl–UCl 3 pseudobinary) and a range of temperatures. Evaluation of the heat flow and mass loss data showed the 0.61NaCl–0.30UCl 3 –0.09PuCl 3 salt had a melting temperature of 551 ± 5 °C. Two additional thermal effects were observed occurring at approximately 410 and 494 °C. The transition occurring at 410 °C may be due to the presence of oxide in the salt. Extrapolation of thermodynamic data indicates the transition occurring at 494 °C is due to the formation of a liquid phase. Experimental testing determined the density of this system is a linear function of temperature and can be represented by the equation ρ = 4.014–0.0010T(°C), R 2 = 0.992. Additionally, by using atomistic modeling, we found that increasing the PuCl 3 content from 5 to 10 mol % led to the formation of larger Pu 3+ clusters and slower transport of ions.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Blind Benchmark Exercise for Spent Nuclear Fuel Decay Heat

The decay heat rate of five spent nuclear fuel assemblies of the pressurized water reactor type were measured by calorimetry at the interim storage for spent nuclear fuel in Sweden. Calculations of the decay heat rate of the five assemblies were performed by 20 organizations using different codes and nuclear data libraries resulting in 31 results for each assembly, spanning most of the current state-of-the-art practice. The calculations were based on a selected subset of information, such as reactor operating history and fuel assembly properties. The relative difference between the measured and average calculated decay heat rate ranged from 0.6% to 3.3% for the five assemblies. The standard deviation of these relative differences ranged from 1.9% to 2.4%.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Calibration of the charge and energy loss per unit length of the MicroBooNE liquid argon time projection chamber using muons and protons

In this paper, we describe a method used to calibrate the position- and time-dependent response of the MicroBooNE liquid argon time projection chamber anode wires to ionization particle energy loss. The method makes use of crossing cosmic-ray muons to partially correct anode wire signals for multiple effects as a function of time and position, including cross-connected TPC wires, space charge effects, electron attachment to impurities, diffusion, and recombination. The overall energy scale is then determined using fully-contained beam-induced muons originating and stopping in the active region of the detector. Using this method, we obtain an absolute energy scale uncertainty of 2% in data. We use stopping protons to further refine the relation between the measured charge and the energy loss for highly-ionizing particles. This data-driven detector calibration improves both the measurement of total deposited energy and particle identification based on energy loss per unit length as a function of residual range. As an example, the proton selection efficiency is increased by 2% after detector calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The BDX detector prototype for dark matter searches in a Beam Dump eXperiment at JLAB

The Beam Dump eXperiment (BDX) is an electron-beam thick-target experiment aimed to investigate the existence of light dark matter particles in the MeV-GeV mass range at Jefferson Lab. A small-scale prototype (BDX-Proto) of the BDX detector has been constructed in order to validate the proposed design and to demonstrate with real measurements the capability to efficiently reject the cosmogenic backgrounds. Here we report the peformance of BDX-Proto extracted from a long campaign of cosmic ray measurements performed at INFN, Sez. Catania and INFN, LNS.

calorimeters↗

Test beam study of SiPM-on-tile configurations

Light yield and spatial uniformity for a large variety of configurations of scintillator tiles were studied. The light from each scintillator was collected by a Silicon Photomultiplier (SiPM) directly viewing the produced scintillation light (SiPM-on-tile technique). The varied parameters included tile transverse size, tile thickness, tile wrapping material, scintillator composition, and SiPM model. Furthermore, these studies were performed using 120 GeV protons at the Fermilab Test Beam Facility. External tracking allowed the position of each proton penetrating a tile to be measured. The results were compared to a GEANT4 simulation of each configuration of scinitillator, wrapping, and SiPM.

47 OTHER INSTRUMENTATION↗

ATHENA detector proposal—a totally hermetic electron nucleus apparatus proposed for IP6 at the Electron-Ion Collider

ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges.

47 OTHER INSTRUMENTATION↗

Photon classification with Gradient Boosted Trees at CLAS12

Dihadron semi-inclusive deep inelastic scattering (SIDIS) of 10.6 GeV longitudinally polarized electrons off the proton has been measured using the CLAS12 detector at Jefferson Lab. Two separate channels, π + π 0 and π - π 0 , were analyzed, requiring the reconstruction of diphoton pairs. Here, in this analysis, we addressed the problem of false neutral particles being reconstructed by CLAS12's event builder, polluting the otherwise physical combinatorial background underneath the π 0 peak. A photon classifier using a Gradient Boosted Trees (GBTs) architecture was trained with Monte Carlo simulations to reduce the amount of background π 0 's. We show that the nearest-neighbor features learned by the model lead to a substantial increase in signal vs. background discrimination compared to previous CLAS12 π^0 analyses. The machine learning approach recovers several times more dihadron statistics for the dataset.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon calibration techniques for high resolution cryogenic detectors

Monoenergetic photons from a pulsed laser diode or LED are commonly used to calibrate the detector response of high-resolution calorimetric detectors. However, when the detector’s resolution is larger than the energy of a single photon, a calibration is normally derived using Poisson statistics. In this paper, we clarify the assumptions implicit in this calibration method, before considering how a more realistic model of a detector’s performance will violate these assumptions, biasing the calibration. Lastly, we judge the individual impact of specific detector parameters on our calibration, and conclude with discussion of both the limits of our calculations and the implications for state-of-the art detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗