Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CORROSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Assessment of Microbiologically Influenced Corrosion Potential in the International Space Station Internal Active Thermal Control System Heat Exchanger Materials: A 6-Momths Study

The fluid in the Internal Active Thermal Control System (IATCS) of the International Space Station (ISS) is water based. The fluid in the ISS Laboratory Module and Node 1 initially contained a mix of water, phosphate (corrosion control), borate (pH buffer), and silver sulfate (Ag2SO4) (microbial control) at a pH of 9.5+/-0.5. Over time, the chemistry of the fluid changed. Fluid changes included a pH drop from 9.5 to 8.3 due to diffusion of carbon dioxide (CO2) through Teflon(reistered Trademark) (DuPont) hoses, increases in dissolved nickel (Ni) levels, deposition of silver (Ag) to metal surfaces, and precipitation of the phosphate (PO4) as nickel phosphate (NiPO4). The drop in pH and unavailability of a antimicrobial has provided an environment conducive to microbial growth. Microbial levels in the fluid have increased from >10 colony-forming units (CFUs)/100 ml to 10(exp 6) CFUs/100 ml. The heat exchangers in the IATCS loops are considered the weakest point in the loop because of the material thickness (=7 mil). It is made of a Ni-based braze filler/CRES 347. Results of a preliminary test performed at Hamilton Sundstrand indicated the possibility of pitting on this material at locations where Ag deposits were found. Later, tests have confirmed that chemical corrosion of the materials is a concern for this system. Accumulation of micro-organisms on surfaces (biofilm) can also result in material degradation and can amplify the damage caused by the chemical corrosion, known as microbiologically influenced corrosion (MIC). This paper will discuss the results of a 6-mo test performed to characterize and quantify the damage from microbial accumulation on the surface of the ISS/ATCS heat exchanger materials. The test was designed to quantify the damage to the materials under worst-case conditions with and without micro-organisms present at pH 8.3 and 9.5.

Roman, Monsi C.↗

Application of Terahertz Radiation to the Detection of Corrosion under the Shuttle's Thermal Protection System

There is currently no method for detecting corrosion under Shuttle tiles except for the expensive process of tile removal and replacement; hence NASA is investigating new NDE methods for detecting hidden corrosion. Time domain terahertz radiation has been applied to corrosion detection under tiles in samples ranging from small lab samples to a Shuttle with positive results. Terahertz imaging methods have been able to detect corrosion at thicknesses of 5 mils or greater under 1" thick Shuttle tiles and 7-12 mils or greater under 2" thick Shuttle tiles.

Madaras, Eric I.↗

Processing and Probability Analysis of Pulsed Terahertz NDE of Corrosion under Shuttle Tile Data

This paper examines data processing and probability analysis of pulsed terahertz NDE scans of corrosion defects under a Shuttle tile. Pulsed terahertz data collected from an aluminum plate with fabricated corrosion defects and covered with a Shuttle tile is presented. The corrosion defects imaged were fabricated by electrochemically etching areas of various diameter and depth in the plate. In this work, the aluminum plate echo signal is located in the terahertz time-of-flight data and a threshold is applied to produce a binary image of sample features. Feature location and area are examined and identified as corrosion through comparison with the known defect layout. The results are tabulated with hit, miss, or false call information for a probability of detection analysis that is used to identify an optimal processing threshold.

Anastasi, Robert F.↗

Selectable-Tip Corrosion-Testing Electrochemical Cell

The figure depicts aspects of an electrochemical cell for pitting- corrosion tests of material specimens. The cell is designed to generate a region of corrosion having a pit diameter determined by the diameter of a selectable tip. The average depth of corrosion is controlled by controlling the total electric charge passing through the cell in a test. The cell is also designed to produce minimal artifacts associated with crevice corrosion. There are three selectable tips, having diameters of 0.1 in. (0.254 cm), 0.3 in. (0.762 cm), and 0.6 in. (1.524 cm), respectively.

Lomness, Janice↗

The Effects of Hot Corrosion Pits on the Fatigue Resistance of a Disk Superalloy

The effects of hot corrosion pits on low cycle fatigue life and failure modes of the disk superalloy ME3 were investigated. Low cycle fatigue specimens were subjected to hot corrosion exposures producing pits, then tested at low and high temperatures. Fatigue lives and failure initiation points were compared to those of specimens without corrosion pits. Several tests were interrupted to estimate the fraction of fatigue life that fatigue cracks initiated at pits. Corrosion pits significantly reduced fatigue life by 60 to 98 percent. Fatigue cracks initiated at a very small fraction of life for high temperature tests, but initiated at higher fractions in tests at low temperature. Critical pit sizes required to promote fatigue cracking were estimated, based on measurements of pits initiating cracks on fracture surfaces.

Gabb, Timothy P.↗

Environmentally Friendly Corrosion Preventative Compounds for Ground Support Structures

The need to use environmentally friendly technologies throughout future space-related launch programs prompted a study aimed at replacing current petroleum and solvent-based Corrosion Preventive Compounds (CPCs) with environmentally friendly alternatives. The work in this paper focused on the identification and evaluation of environmentally friendly CPCs for use in protecting flight hardware and ground support equipment from atmospheric corrosion. CPCs are used as temporary protective coatings and must survive in the aggressive coastal marine environment that exists throughout the Kennedy Space Center, Florida. The different protection behaviors of fifteen different oily film CPCs, both common petroleum-based and newer environmentally friendly types, were evaluated on various steel and aluminum substrates. CPC and substrate systems were subjected to atmospheric testing at the Kennedy Space Center's Beachside Atmospheric Corrosion Test Site, as well as cyclic accelerated corrosion testing. Each CPC also underwent physical characterization and launch-related compatibility testing. The results for the fifteen CPC systems are presented in this paper.

Montgomery Eliza L.↗

Smart Coatings for Launch Site Corrosion Protection

Smart, environmentally friendly paint system for early corrosion detection, mitigation, and healing that will enable supportability in KSC launch facilities and ground systems through their operational life cycles. KSC's Corrosion Technology Laboratory is developing a smart, self-healing coating that can detect and repair corrosion at an early stage. This coating is being developed using microcapsules specifically designed to deliver the contents of their core when corrosion starts.

TechPort Portfolio System↗

Stress Corrosion Cracking of Metals in Propellants

Stress corrosion cracking (SCC) of a fracture critical metallic material can cause a premature failure if the material is susceptible in the unique service environment. Material fluid compatibility is an area of interest for the current NASA programs leading the human exploration path to Mars. White Sands Test Facility, the agency's lead on hypergolic propellant testing, identifies a lack in stress corrosion cracking susceptibility data for metallic materials in hypergolic propellants. The development of a stress corrosion cracking screening method is necessary to bridge the knowledge gap and enable the community to more confidently select materials for the use in systems containing corrosive fluids.

Alcantara, Ilse↗

Pre-Demonstration Development of Controlled-Release Corrosion Inhibitors and Healing Agents as Alternatives to Hexavalent Chromium

This Limited Scope Study was directed to achieve the following objectives: (1) Scale-up of materials that can meet MIL-PRF-23377 (solvent-based primer). (2) Provide evidence of resistance to aircraft alkaline cleaners and de-icing fluids. (3) Provide formulation for initial ecological and toxicity screening. (4) Submit an interim report that will provide the basis for a future ESTCP (the Dept. of Defense's (DoD's) Environmental Security Technology Certification Program) demonstration effort.The encapsulation procedure for two corrosion inhibitors was scaled up from lab scale to 2.0 kilograms. This scale will accommodate high volume production of coatings with encapsulated corrosion inhibitors for large surface areas during a follow-on ESTCP demonstration effort. Test results provided evidence of resistance to alkaline cleaners and aircraft de-icing fluids and compliance with MIL-PRF-23377. All the MIL-PRF-23377 requirements were met with the exception of the adhesion requirement, in top coated panels, and the flexibility requirement. Work on solving these two problems will be done prior to validation and demonstration of the technology. An initial ecological and toxicity screening identified several factors that were not critical to the acceptance of the encapsulated corrosion inhibitor. This new technology will lead to environmentally friendly alternatives to hexavalent chromium that will enable DoD to protect its assets. Field demonstration, licensing, qualification, and commercialization will allow its real world utilization. Abstract for Appendix A. Toxicology Report: Corrosion controls a significant problem for military equipment. Many surface treatment materials currently in use on items of military or aerospace materiel contain chromium (VI) as a component, a source of significant human health and environmental hazard. The formulation under evaluation contains no chromium. Most of the proposed components are low to moderate toxicity and are not a significant concern. Two of the formulation components are associated with some cancer hazard - 2-mercaptobenzothiazole and formaldehyde, but both find widespread use in industry and additional investigation is not required for this project.

Calle, Luz Marina↗

Novel Membrane-Based Corrosion Sensors For Operating In Natural Gas Pipelines

Membrane-based electrochemical sensors (MBES) provide an attractive option for real-time continuous humidity and corrosion rate measurements inside of natural gas pipelines. The MBES, can use electrochemical techniques such as linear polarization resistance and electrochemical impedance spectroscopy even when a conductive aqueous phase is intermittent or unavailable. We now present field-test performance data of our MBES operated inside a multiphase water and natural gas flow facility. The MBES measured internal corrosion and conductivity at the top, bottom, and side of the pipe spool. Tests were carried out with flow rates of 4.6, 9.1, and 18.3 m/s, temperatures of 21, 29, and 35 °C, and a pressure of 1000 psia. All sensors followed similar trends in open circuit potential, corrosion rate, and conductivity over time. Neither flow rate, temperature, nor build-up of metal-based solids on the sensor surfaces impacted the quality of the electrochemical measurements. The field-test results confirm that the membrane-based electrochemical sensors are suitable for monitoring internal corrosion of operational natural-gas pipelines.

Duffy, Timothy↗

Evaluation of Corrosion Susceptibility of Structural Steels in Biomass Derived Pyrolysis Oil

Biomass derived pyrolysis oil is a promising renewable energy source. Due to the variety of biomass feedstocks, the bio-oils could contain a wide range of organic constituents which would provide unique corrosive environments for structural materials. A preliminary work exposed different classes of steels and stainless steels to selected organic constituents of biomass pyrolysis oils and found that corrosion susceptibility, assessed using electrochemical impedance spectroscopy (EIS), was prominent in the steels with Cr lower than 11 wt.%. Although this result suggests stainless steels will resist corrosion by certain organic constituents, it may not be sufficient to predict the corrosion performance in real bio-oils. Therefore, this study attempted electrochemical measurements on Cr-alloyed steels and stainless steels directly exposed to a biomass derived pyrolysis oil. To overcome the low conductivity of bio-oils, a customized Luggin capillary was designed to minimize the ohmic path in bio-oils. The results of this work will be reported.

Jun, Jiheon↗

Electrochemical Corrosion of SIMFUEL: Effects of dissolved H2 and noble metal particles

This report describes the results from electrochemical corrosion tests that were conducted using simulated spent fuel (SIMFUEL) materials comprised of UO2 and surrogate fission products. Two SIMFUEL compositions were tested to quantify the effect of noble metal inclusions and dissolved H2 on the UO2 dissolution rate. One material consisted of UO2 with added lanthanide oxides (UO2 N) and the other consisted of UO2 with added lanthanide oxides and noble metals (UO2-H) at concentrations to simulate high burnup fuel. The electrochemical corrosion tests on the SIMFUEL materials were conducted in aqueous electrolyte solutions (pH 10) that were either saturated with air or purged with a H2/Ar gas mixture to maintain a constant dissolved H2 concentration. The results from electrochemical corrosion tests on SIMFUEL can be applied to qualitatively understand and also quantify the separate effects of water chemistry and fuel composition on the degradation behavior of the UO2 matrix. Open circuit potential (OCP) measurements on a SIMFUEL material of known composition (i.e., known fraction of NMPs at the fuel surface) immersed in a known solution chemistry (i.e., pH, Eh, [O2], [H2]) at known temperature provide qualitative insight into the degradation behavior of the UO2 matrix. If the OCP is above the threshold potential at which the oxidative dissolution of U(IV) to U(VI) occurs, the SNF is expected to degrade by oxidative processes under the experimental conditions. The net currents that are measured during potentiostatic tests, during which the surface potential of the SIMFUEL material is fixed by a potentiostat, can be used to quantify the UO2 degradation rate and optimize the rate constant values used in the Fuel Matrix Degradation Model (FMDM) for half reactions that occur on the SNF surface. Specifically, electrochemical measurements enable the estimation of the total anodic current at ECORR–which is the surface potential at which the total anodic and total cathodic currents are equal–so that the rate constant values for key reactions can be calculated. The open circuit potential measurements, potentiostatic tests, surface property measurements (scanning electron microscopy images and electrochemical impedence spectroscopy plots), and solution elemental composition analyses are being performed to update and optimize the FMDM. A case study is presented herein to show how electrochemical corrosion test results and accompanying characterization results for the UO2 N material in air-saturated solution can be used to validate the SNF surface reaction module of the FMDM. Future electrochemical tests will be conducted to provide quantitative information on the effects of NM content (burnup), H2 concentration, water chemistry, temperature, and galvanic couples with cladding and EBS alloys on UO2 degradation that can be used to improve the accuracy and functionality of the FMDM.

Thomas, Sara↗

Electrochemical corrosion under controlled redox conditions

A method for predicting corrosion rates of a material during service conditions is provided, the method having the steps of determining a first phase composition of the material; exposing the material to service conditions chemical environment; applying an electrical potential to the exposed material to represent the solution redox; identifying ranges of the applied potential that correspond to different corrosion behaviors of the material; quantifying current and surface electrical properties during corrosion; and determining a second phase composition of the material to identify corroded phases. Also provided is a method for determining radionuclide source terms, the method having the steps of supplying a multiphase metallic waste containing the radionuclides; immersing the waste in a solution representing repository chemistry conditions; and oxidizing the immersed waste for a period of time and at particular imposed voltages representing solution redox values to establish a steady current representing corrosion rate of the waste.

Gattu, Vineeth Kumar↗

Modeling of High-Temperature Corrosion of Zirconium Alloys Using the eXtended Finite Element Method (X-FEM)

Oxidation modeling in modern nuclear fuel performance codes is currently limited by the lack of coupling with mechanics, thus preventing proper description of how high-temperature oxidation impacts mechanical properties. This is mostly due to the fact that the finite difference formalism adopted in corrosion models is incompatible with the direct coupling with mechanics in the finite element modeling employed in modern nuclear fuel performance codes. In this study, a physically based zirconium alloy corrosion model called the Coupled-Current Charge Compensation (C4) model, which was initially developed for operating temperature conditions, has been updated to include high-temperature corrosion in order to provide additional critical information (e.g., oxygen concentration profile) under loss-of-coolant accident (LOCA) conditions—information lacking in existing empirical models. The C4 model was implemented in the MOOSE finite-element framework developed at Idaho National Laboratory, enabling it to be used in the BISON nuclear fuel performance code based on the MOOSE framework. To precisely track the different interfaces at a relatively low computational cost, the eXtended Finite Element Method (X-FEM) was applied in MOOSE. The model’s results were compared to those of existing empirical models as well as metallographic analysis of high-temperature oxidized Zircaloy-4 coupons. Oxygen diffusivities in the a and ß phases resulting from this comparison closely agree with those found in the literature. The C4 model implemented with X-FEM in MOOSE now has the capability to accurately predict oxide, oxygen-stabilized a, and prior ß phase layer growth kinetics under isothermal exposure at high temperature (1000–1500°C). Furthermore, in contrast with the empirical models, the C4 model accounts for the finite thickness of the fuel cladding. It can predict the oxygen concentration profile evolution through the whole cladding, enabling evaluation of the remaining ductile thickness—a crucial variable for modeling the mechanical behavior of the fuel cladding under LOCA. Furthermore, this implementation allows direct coupling with mechanics, at a low computing cost, using finite-element-based nuclear fuel performance codes such as BISON.

36 MATERIALS SCIENCE↗

In-service corrosion and grain boundary oxidation in neutron-irradiated 316 stainless steel baffle-former bolts

Reactor core internal components such as baffle-former bolts (BFBs) are subjected to significant mechanical stress, corrosive environment, and neutron irradiation from the reactor core during the plant operation. Over the long operation period, these conditions lead to potential degradation and of the bolts. In this work, characterization was performed on the oxidized surface of stainless steel BFBs harvested from a commercial pressurized water reactor (PWR) after 40 years of operation. The analysis shows that a complex multilayered surface oxide with six identified layers formed that is different from 2-layer structure commonly observed in model experiments. The oxide varies by composition – predominantly Fe, Cr, and Ni, grain size, and phase, and has features resembling both unirradiated and radiation/ corrosion experiments likely due to the low radiation flux compared to ion-irradiation or the test reactor radiation. In addition, grain boundary oxidative attack featured a pathway for Fe and other elements to move from the metal matrix to the outermost oxide. In conclusion, the results help assess PWR lifetime extension, put into context previous experimental studies, and provide input for designing experiments combining radiation and corrosion effects.

Baffle-former bolt↗

Stress corrosion cracking mechanism of cold spray coating on a galvanically similar substrate

Here, the chloride-induced stress corrosion cracking (CISCC) mechanism of cold spray (CS) coating on a galvanically similar substrate is investigated. Arc welded 304L stainless steel (SS) specimens are loaded into four-point bend fixtures, cold sprayed with 304L SS, then immersed in boiling MgCl 2 . Interconnected porosity forms through crevice corrosion along CS splat boundaries, allowing corrosive species to penetrate through the CS layer. Nevertheless, the substrate is resistant to CISCC likely because of compressive stress introduced by peening during CS particle impacts. These findings underscore the importance of residual stress in the environmental degradation of CS coatings or repairs of engineering structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The corrosion effects of neutron activation of 2LiF-BeF 2 (FLiBe)

The redox effect of activation reactions in molten salts has been previously qualitatively defined but never quantified. Here, we quantify the corrosion effects of neutron activation of FLiBe. Rates of change of activation products are computed for FHR and ARC. The impact of activation reactions on salt chemistry is quantitatively compared to other environmental effects of similar consequences on the salt. The results are applied to a redox control case-study and an irradiation-corrosion experiment. The results are presented in a manner useful to the reactor chemist and designer concerned with corrosion and chemistry control and tritium management in irradiated FLiBe, and design of salt-irradiation experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FY23 Progress Report: SRNL Analysis of ICCWR LCM and WAMS data for Corrosion and Cracking

Algorithms for Machine Learning (ML) and data analysis for the 3013 Surveillance Program have been developed in an ongoing collaborative effort by the Savannah River National Laboratory (SRNL) and the University of South Carolina (USC). The objective of the algorithms is to automate the identification of corrosion and crack formation in the Inner Container Closure Weld Region (ICCWR) of the canister system used to store Pu-bearing material. Data for corrosion and cracking is collected from large binary files generated by a Laser Confocal Microscope (LCM), the Wide Area 3D Measurement System (WAMS), and in a recent proposal, by a Scanning Electron Microscope (SEM). The ML software uses the physical attributes in the data files (e.g., one or all of: height, color, and grayscale values as functions of position in a plane projection) to detect the presence of surface corrosion and cracking after being trained on similar data with the features to be detected labeled.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗