Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONGESTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

What is the Right Size for a Residential Building Parcel Locker?

Common-carrier parcel lockers present a solution for decreasing delivery times, traffic congestion, and emissions in dense urban areas through consolidation of deliveries. Multi-story residential buildings with large number of residents, and thus a high volume of online package orders, are one of the best venues for installing parcel lockers. But what is the right size for a residential building locker that would suit the residents’ and building managers’ needs? Because of the novelty of parcel lockers, there is no clear guideline for determining the right locker size and configuration for a residential building given the resident population. A small locker would result in packages exceeding capacity and being left in the lobby, increasing the building manager’s workload and confusing and inconveniencing users. On the other hand, a large locker is more expensive, more difficult to install, and unappealing to residents. To answer this question, we installed a common-carrier parcel locker in a residential building in downtown Seattle, WA, U.S.A. Through collecting detailed data on locker usage from the locker provider company, we studied and quantified carriers’ delivery patterns and residents’ online shopping and package pickup behaviors. We then used this information to model the locker delivery and pickup process, and simulated several locker configurations to find the one that best suits the delivery needs of the building. These findings could aid urban planners and building managers in choosing the right size for residential building lockers that meet delivery demand while minimizing costs and contributing to environmental benefits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Estimation of Arrivals on Green at Signalized Intersections Using Stop-Bar Video Detection

Across the world, traffic congestion is increasing with alarming rapidity. Traffic signal control effectiveness, in coordinated networks, is often investigated in relation to the type of vehicle arrivals at the signalized intersections. Recently, several transportation agencies have switched from traditional loop detectors to video detection. When video cameras are accompanied by computer vision, one can extract more information about traffic “dynamics” than by using traditional inductive loop detectors. Collecting arrival times of multiple vehicles after the first arrival at the stop-bar detector might be challenging when using inductive loop detectors (since after the first arrival, detector status is always occupied). However, emerging video detection systems allow tracking of each vehicle’s entrance time in the detection zone, departure time from the detection zone, and the type of vehicle. This information can be used to estimate vehicular arrival and departure times, which then can be fed into machine learning algorithms to estimate arrivals on green (AOG). However, such research ideas have not been documented so far. Thus, this paper presents an estimation model for AOG, which was developed using multigene genetic programming. A robust experimental dataset was collected from a highly calibrated and validated microsimulation model of an 11-intersection corridor in Chattanooga, TN. The results of the model’s performance analysis showed the high accuracy of the training-, testing-, and validation datasets. The practical benefit of this model is that it can be applied to estimate arrival types at intersections where only stop-bar video detection exists.

Engineering↗

Opposing Hysteresis Patterns in Flow and Outflow Macroscopic Fundamental Diagrams and Their Implications

Two key aggregated traffic models are the relationship between average network flow and density (known as the network or flow macroscopic fundamental diagram [flow-MFD]) and the relationship between trip completion and density (known as network exit function or the outflow-MFD [o-FMD]). The flow- and o-MFDs have been shown to be related by average network length and average trip distance under steady-state conditions. However, recent studies have demonstrated that these two relationships might have different patterns when traffic conditions are allowed to vary: the flow-MFD exhibits a clockwise hysteresis loop, while the o-MFD exhibits a counter-clockwise loop. One recent study attributes this behavior to the presence of bottlenecks within the network. The present paper demonstrates that this phenomenon may arise even without bottlenecks present and offers an alternative, but more general, explanation for these findings: a vehicle’s entire trip contributes to a network’s average flow, while only its end contributes to the trip completion rate. This lag can also be exaggerated by trips with different lengths, and it can lead to other patterns in the o-MFD such as figure-eight patterns. A simple arterial example is used to demonstrate this explanation and reveal the expected patterns, and they are also identified in real networks using empirical data. Then, simulations of a congestible ring network are used to unveil features that might increase or diminish the differences between the flow- and o-MFDs. Finally, more realistic simulations are used to confirm that these behaviors arise in real networks.

42 ENGINEERING↗

Revenue-Maximizing Shared Parking and Electric Vehicle Charging Management in Multi-Unit Dwellings

In urban areas, searching for parking and electric vehicle (EV) charging can result in cruising, congestion, and environmental externalities. Recognizing the business opportunity of offering private parking and charging infrastructure access within multi-unit dwellings (MUDs) during daytime, we model a shared parking and EV charging management system. We maximize the revenue of MUD charging hubs in mixed land use, catering to public demand. Our approach accounts for the objectives of the two stakeholders involved: a demand model is fitted on the choices of EV charging users, and the supply model optimizes the allocation of parking and charging requests in an MUD parking lot. A binary integer linear programming model for the allocation of parking and charging spaces with a rolling horizon is integrated with matching rules that handle both parking and charging requests. In our numerical experiments in a neighborhood of Chicago, Illinois, we estimate the performance of the MUD parking and charging system with metrics that include revenue, number of matchings, and utilization rates. At any given time, MUDs with lower prices attract more charging requests, particularly those of longer duration, resulting in higher revenue and greater charging utilization. Dynamic pricing facilitates a more equitable distribution of requests; as MUD parking lots reach capacity and their fees increase, other MUDs become more competitive, attracting additional requests. Comparing our method against first-come-first-served and optimal-solution benchmarks, we demonstrate our model’s effectiveness in dynamically managing mixed parking and charging demand in MUD charging hubs.

electric vehicle, multi-unit dwelling, charging in↗

Chapter 13: All-Electric Vertical Take-Off and Landing Aircraft (eVTOL) for Sustainable Urban Travel

Increasing urbanization, ground congestion, and greenhouse gas emissions have spurred aircraft pioneers to capitalize on advancements in battery technology, electric motors, software, and other advances to develop all-electric vertical take-off and landing (eVTOL) aircraft intended to save travelers time within densely populated urban regions. This study served as an example for conducting a life-cycle analysis (LCA) of an eVTOL aircraft, analyzing its manufacturing process, its in-life operation as a passenger transportation service between urban locations, and (in part) end-of-life treatment. This case study aims to provide guidance on how to accurately conduct eVTOL LCA, particularly on how to define the problem, how to obtain the right information from engineers inside and outside their own organizations, and what areas to focus on. As LCA results are only as accurate as the assumptions that were made, a more rigorous LCA that includes sensitivity analysis and uncertainty characterization can help further understand the limitations of those assumptions. New technologies such as blockchain may also play an important role in LCA, including the life-cycle inventory and improving confidence intervals. Completing a credible LCA is central to supporting the argument in favor of introducing the new technology. Completing such a study will allow companies to demonstrate to relevant stakeholders the likely impact of their aircraft on the environment by quantifying the operational climate footprint of the aircraft and the manufacturing process used to build it. To this end, this case study also provides examples of how to report and present LCA results, optimizing for communications to non-LCA experts. The LCA can also assist in identifying opportunities to improve the environmental performance at various life-cycle stages, informing decision makers as products and manufacturing processes evolve or are redesigned. Given the nascency of both eVTOL aircraft manufacturing and operations, it is strongly recommended that LCA analysts treat reports on eVTOL aircraft as works-in-progress. As new information is found, design changes are made, and the aircraft or operation gains maturity, it is inevitable that some amendments will need to be made to the LCA. It is suggested that a complete overhaul of the LCA be made every 18-24 months throughout the R&D, design, and operational scale-up phases of the project.

ADVANCED PROPULSION SYSTEMS↗

Transmission Capacity Allocation in Zonal Electricity Markets

In this work, we propose a novel framework for modeling zonal electricity markets, based on projecting the constraints of the nodal network onto the space of the zonal aggregation of the network. The framework avoids circular definitions and discretionary parameters, which are recurrent in the implementation and study of zonal markets. Using this framework, we model and analyze two zonal market designs currently present in Europe: flow-based market coupling (FBMC) and available-transfer-capacity market coupling (ATCMC). We develop cutting-plane algorithms for simulating FBMC and ATCMC while accounting for the robustness of imports/exports to single element failures, and we conduct numerical simulations of FBMC and ATCMC on a realistic instance of the Central Western European system under the equivalent of 100 years of operating conditions. We find that FBMC and ATCMC are unable to anticipate the congestion of branches interconnecting zones and branches within zones and that both zonal designs achieve similar overall cost efficiencies (0.01% difference), whereas a nodal market design largely outperforms both of them (5.09% better than FBMC). These findings raise the question of whether it is worth it for more European countries to switch from ATCMC to FBMC, instead of advancing directly toward a nodal market design.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Toward lower-diameter large-scale HPC and data center networks with co-packaged optics

We investigate the advantages of using co-packaged optics for building low-diameter, large-scale high-performance computing (HPC) and data center networks. The increased escape bandwidth offered by co-packaged optics can enable high-radix switch implementations of more than 150 switch ports, which can be combined with data rates of up to 400 Gb/s per port. From the network architecture perspective, the key benefits of using co-packaged optics in future fat-tree networks include (a) the ability to implement large-scale topologies of > <#comment/> 11 , 000 end points by eliminating the need for a third switching layer and (b) the ability to provide up to 4 × <#comment/> higher bisection bandwidth compared to existing solutions, reducing at the same time the number of required switch application-specific integrated circuits by > <#comment/> 80 % <#comment/> . From the network operation perspective, both reduced energy consumption and lower packet delays can be achieved since fewer hops are required; i.e., packets need to traverse fewer serializer/deserializer lanes and fewer switch buffers, which reduces the probability of contending with other packets and improves the tolerance of network congestion. The performance of the proposed architecture is evaluated via discrete-event simulations for a wide range of representative HPC synthetic-traffic cases that include both hotspot and non-hotspot scenarios. The simulation results suggest that co-packaged optics form a promising solution to keep up with bandwidth scaling in future networks, while the reduced number of switching layers can lead to significant mean packet delay improvements that start from 30% and reach up to 74% for high-load conditions.

Maniotis, Pavlos (ORCID:0000000244905253)↗

Quantifiable Biomarkers of Normal Aging in the Japanese Medaka Fish (Oryzias latipes)

Background: Small laboratory fish share many anatomical and histological characteristics with other vertebrates, yet can be maintained in large numbers at low cost for lifetime studies. Here we characterize biomarkers associated with normal aging in the Japanese medaka (Oryzias latipes), a species that has been widely used in toxicology studies and has potential utility as a model organism for experimental aging research. Principal Findings: The median lifespan of medaka was approximately 22 months under laboratory conditions. We performed quantitative histological analysis of tissues from age-grouped individuals representing young adults (6 months old), mature adults (16 months old), and adults that had survived beyond the median lifespan (24 months). Livers of 24- month old individuals showed extensive morphologic changes, including spongiosis hepatis, steatosis, ballooning degeneration, inflammation, and nuclear pyknosis. There were also phagolysosomes, vacuoles, and residual bodies in parenchymal cells and congestion of sinusoidal vessels. Livers of aged individuals were characterized by increases in lipofuscin deposits and in the number of TUNEL-positive apoptotic cells. Some of these degenerative characteristics were seen, to a lesser extent, in the livers of 16-month old individuals, but not in 6-month old individuals. The basal layer of the dermis showed an age-dependent decline in the number of dividing cells and an increase in senescence-associated bgalactosidase. The hearts of aged individuals were characterized by fibrosis and lipofuscin deposition. There was also a loss of pigmented cells from the retinal epithelium. By contrast, age-associated changes were not apparent in skeletal muscle, the ocular lens, or the brain. Significance: The results provide a set of markers that can be used to trace the process of normal tissue aging in medaka and to evaluate the effect of environmental stressors.

59 BASIC BIOLOGICAL SCIENCES↗

1994 SEMCOG Household-Based Person Trip Survey

The Southeast Michigan Council of Governments contracted with the Applied Management & Planning Group to conduct a travel behavior survey of 7,361 households from March 28, 1994, to June 10, 1994. The primary purpose of this study was to provide the council with a new database of travel behavior to assist in updating the region's transportation models. This data collection includes demographic, socioeconomic, travel, and mobile source emissions models for projecting future patterns of development, travel, congestion, and air pollution. Information about household characteristics and travel was collected using a one-day, activity-focused diary and a separate household survey. In an activity diary, respondents recorded 65,535 trips during the assigned the day.

1Hz data↗

1996 Bay Area Travel Study Wave 2

The 1996 Bay Area Travel Study, conducted by the Metropolitan Transportation Commssion, collected demographic, socioeconomic, and travel data for 3,618 households in California's nine-county Bay Area: Alameda, Contra Costa, Marin, Napa, San Francisco, San Mateo, Santa Clara, Solano, and Sonoma counties. The goal of the study was to collect information on activities for all people in each household, regardless of age or relationship. Respondents were asked to record all activities, including trips, over a two-day period. The data gathered during the survey will be used for the area's long-term transportation and air quality planning needs. The survey collected both weekday and weekend multi-day data and was the first activity-based survey conducted in the Bay Area. It also included separate sub-projects. A stated preference congestion pricing survey was administered to 150 of the respondents with a follow-up survey conducted with 110 participants. A follow-up survey was also completed by over half of the 3,618 respondent households to update contact and demographic information. These participants were then used as a panel sample for the 2000 Bay Area Travel Survey (NuStats Research and Consulting 1999).

1Hz data↗

The allocation of a variable series reactor considering AC constraints and contingencies

The Variable Series Reactors (VSRs) can efficiently control the power flow through the adjustment of the line reactance. When they are appropriately allocated in the power network, the transmission congestion and generation cost can be reduced. Our work proposes a planning model to optimally allocate VSRs considering AC constraints and multi-scenarios including base case and contingencies. The planning model is originally a non-convex large scale mixed integer nonlinear program (MINLP), which is generally intractable. The proposed Benders approach decomposes the MINLP model into a mixed integer linear program (MILP) master problem and a number of nonlinear subproblems. Numerical case studies based on IEEE 118-bus demonstrate the high performance of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy transport corridors: the potential role of Federal lands in states identified by the Energy Policy Act of 2005, section 368(b).

On August 8, 2005, the President signed the Energy Policy Act of 2005 (EPAct) into law. In Subtitle F of EPAct, Congress set forth various provisions that would change the way certain federal agencies (Agencies) coordinate to authorize the use of land for a variety of energy-related purposes. As part of Subtitle F of EPAct, Section 368 addresses the issue of energy transportation corridors on federal land for oil, gas, and hydrogen pipelines, as well as electricity transmission and distribution facilities. Because of the critical importance of improving the nation's electrical transmission grid, Congress recognized that electricity transmission issues should receive added attention when the Agencies address corridor location and analysis issues. In Section 368, Congress specifically directed the Agencies to consider the need for upgraded and new facilities to deliver electricity: In carrying out [Section 368], the Secretaries shall take into account the need for upgraded and new electricity transmission and distribution facilities to (1) improve reliability; (2) relieve congestion; and (3) enhance capability of the national grid to deliver electricity. Section 368 does not require the Agencies to consider or approve specific projects, applications for rights-of-way (ROWs), or other permits within designated energy corridors. Importantly, Section 368 does not direct, license, or otherwise permit any on-the-ground activity of any sort. If an applicant is interested in obtaining an authorization to develop a project within any corridor designated under Section 368, the applicant would have to apply for a ROW authorization and applicable permits. The Agencies would consider each application by applying appropriate project-specific reviews under requirements of laws and related regulations, including, but not limited to, the National Environmental Policy Act (NEPA), the Clean Water Act, the Clean Air Act, Section 7 of the Endangered Species Act (ESA), and Section 106 of the National Historic Preservation Act (NHPA). Under Section 368, Congress divided the United States into two groups of states: the 11 contiguous western states and the remaining states. Direction for energy transportation corridor analysis and selection in the 11 western states was addressed in Section 368(a) of EPAct, while direction for energy transportation corridor analysis and selection in all other states was addressed under Section 368(b) of EPAct. It was clearly the priority of Congress to conduct corridor location studies and designation first on federal lands in the western states. Under Section 368(a), the Agencies produced a programmatic environmental impact statement (EIS), Designation of Energy Corridors on Federal Land in the 11 Western States (DOE and DOI 2008), that was used in part as the basis for designating more than 6,000 mi (9,656 km) of energy transportation corridors on federal land in 11 western states. Under Section 368(a) of EPAct, Congress clearly stated the Agencies needed to (1) designate energy transportation corridors on federal land, (2) conduct the necessary environmental review of the designated corridors, and (3) incorporate the designated corridors into the appropriate land use plans. Congressional direction under Section 368(b) of EPAct differs from that provided under Section 368(a). Specifically, Section 368(b) requires the secretaries of the Agencies, in consultation with the Federal Energy Regulatory Commission (FERC), affected utility industries, and other interested persons, to jointly: (1) Identify corridors for oil, gas, and hydrogen pipelines and electricity transmission and distribution facilities on federal land in states other than the 11 western states identified under Section 368(a) of EPAct, and (2) Schedule prompt action to identify, designate, and incorporate the corridors into the applicable land use plans. While Section 368(a) clearly directs designation as a necessary first step for energy transportation corridors in the 11 western states, Section 368(b) directs the Agencies to first identify corridors and then schedule prompt action to identify, designate, and incorporate the corridors into applicable land use plans. To comply with the congressional direction provided in Section 368(b), the Agencies investigated corridor identification issues in the Section 368(b) states; this report to Congress provides information that could be relevant to possible future designation of energy corridors. Future designations, if appropriate and necessary, would occur when the Agencies undertake revisions and/or updates to land use plans that guide management decisions on lands located within individual administrative units, such as specific National Forests, National Parks, or Wildlife Refuges. At this time, the Agencies are not proposing any actions or decisions related directly or indirectly to designating energy corridors on federal land under Section 368(b) of EPAct.

08 HYDROGEN↗

Model Request for Proposals to Provide Energy and other Attributes from an Offshore Wind Power Project

This document provides a model RFP for new generation. The 'base' RFP is for a single-source offshore wind RFP. Required modifications are noted should a state or utility seek multi-source bids (e.g., all renewables or all sources). The model is premised on proposals meeting threshold requirements (e.g., a MW range of generating capacity and a range in terms of years), RFP issuer preferences (e.g., likelihood of commercial operation by a date certain, price certainty, and reduction in congestion), and evaluation criteria, along with a series of plans (e.g., site, environmental effects, construction, community outreach, interconnection, etc.). The Model RFP places the most weight on project risk (45%), followed by project economics (35%), and environmental and social considerations (20%). However, if a multi-source RFP is put forward, the sponsor would need to either add per-MWh technology-specific, life-cycle climate (CO2), environmental and health impact costs to bid prices under the 'Project Economics' category or it should increase the weight given to the 'Environmental and Social Considerations' category.

17 WIND ENERGY↗

Dynamic Line Rating Oncor Electric Delivery Smart Grid Program

Electric transmission lines are the lifeline of the electric utility industry, delivering its product from source to consumer. This critical infrastructure is often constrained such that there is inadequate capacity on existing transmission lines to efficiently deliver the power to meet demand in certain areas or to transport energy from high-generation areas to high-consumption regions. When this happens, the cost of the energy rises; more costly sources of power are used to meet the demand or the system operates less reliably. These economic impacts are known as congestion, and they can amount to substantial dollars for any time frame of reference: hour, day or year. There are several solutions to the transmission constraint problem, including: construction of new generation, construction of new transmission facilities, rebuilding and reconductoring of existing transmission assets, and Dynamic Line Rating (DLR). All of these options except DLR are capital intensive, have long lead times and often experience strong public and regulatory opposition. The Smart Grid Demonstration Program (SGDP) project co-funded by the Department of Energy (DOE) and Oncor Electric Delivery Company developed and deployed the most extensive and advanced DLR installation to demonstrate that DLR technology is capable of resolving many transmission capacity constraint problems with a system that is reliable, safe and very cost competitive. The SGDP DLR deployment is the first application of DLR technology to feed transmission line real-time dynamic ratings directly into the system operation’s State Estimator and load dispatch program, which optimizes the matching of generation with load demand on a security, reliability and economic basis. The integrated Dynamic Line Rating (iDLR)1 collects transmission line parameters at remote locations on the lines, calculates the real-time line rating based on the equivalent conductor temperature, ambient temperature and influence of wind and solar radiation on the stringing section, transmits the data to the Transmission Energy Management System, validates its integrity and passes it on to Oncor and ERCOT (Electric Reliability Council of Texas) respective system operations. The iDLR system is automatic and transparent to ERCOT System Operations, i.e., it operates in parallel with all other system status telemetry collected through Supervisory Control and Data Acquisition (SCADA) employed across the company.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preliminary Feasibility Assessment of Integrating CCHP with NW Food Processing Plant #1: Modeling Documentation

The Pacific Northwest National Laboratory (PNNL) has launched a project funded by the Bonneville Power Association (BPA) to identify strategies for increasing industrial energy efficiency and reducing energy costs of Northwest Food Processors Association (NWFPA) plants through deployment of novel combinations and designs of variable-output combined heat and power (CHP) distributed generation (DG), combined cooling, heating and electric power (CCHP) DG and energy storage systems. Detailed evaluations and recommendations of CHP and CCHP DG systems will be performed for several Northwest (NW) food processing sites. The objective is to reduce the overall energy use intensity of NW food processors by 25% by 2020 and by 50% by 2030, as well as reducing emissions and understanding potential congestion reduction impacts on the transmission system in the Pacific Northwest.

Bonneville Power Association↗

Using architecture information and real-time resource state to reduce power consumption and communication costs in parallel applications.

As computer systems grow in both size and complexity, the need for applications and run-time systems to adjust to their dynamic environment also grows. The goal of the RAAMP LDRD was to combine static architecture information and real-time system state with algorithms to conserve power, reduce communication costs, and avoid network contention. We devel- oped new data collection and aggregation tools to extract static hardware information (e.g., node/core hierarchy, network routing) as well as real-time performance data (e.g., CPU uti- lization, power consumption, memory bandwidth saturation, percentage of used bandwidth, number of network stalls). We created application interfaces that allowed this data to be used easily by algorithms. Finally, we demonstrated the benefit of integrating system and application information for two use cases. The first used real-time power consumption and memory bandwidth saturation data to throttle concurrency to save power without increasing application execution time. The second used static or real-time network traffic information to reduce or avoid network congestion by remapping MPI tasks to allocated processors. Results from our work are summarized in this report; more details are available in our publications [2, 6, 14, 16, 22, 29, 38, 44, 51, 54].

Brandt, James M.↗

The Transportation Leapfrog: Using Smart Phones to Collect Driving Data and Model Fuel Economy in India

Car ownership in India is expected to skyrocket in the coming decades, strongly driven by rising incomes. This phenomenon provides unprecedented opportunities for automakers and equally unprecedented social and environmental challenges. Policymakers, urban planners and civil society see this car boom leading to an explosion in problems related to congestion, infrastructure, air pollution, safety, higher oil imports and climate change. For all these stakeholders to take effective action, good data on how people use their cars, their demand for mobility and their behavior in mobility is essential. Unfortunately, there is very little data on the Indian transport sector as a whole and virtually none on real-world vehicle performance and use. The rapid development of high quality mobile telecommunications infrastructure provides India with the opportunity to leapfrog the West in cheaply collecting vast amounts of useful data from transportation. In this paper, we describe a pilot project in which we use commercial smart phone apps to collect per second car driving data from the city of Pune, instantly upload it through 3G and prepare it for analysis using advanced noise filtering algorithms for less than $1 per day per car. We then use our data in an Autonomie simulation to show that India’s currently planned fuel economy test procedures will result in over-estimates of fuel economy of approximately 35% for a typical Indian car when it is operated in real world conditions. Supporting better driving cycle development is just one of many applications for smart phone derived data in Indian transportation.

25 ENERGY STORAGE↗

WINS. Market Simulation Tool for Facilitating Wind Energy Integration

Integrating 20% or more wind energy into the system and transmitting large sums of wind energy over long distances will require a decision making capability that can handle very large scale power systems with tens of thousands of buses and lines. There is a need to explore innovative analytical and implementation solutions for continuing reliable operations with the most economical integration of additional wind energy in power systems. A number of wind integration solution paths involve the adoption of new operating policies, dynamic scheduling of wind power across interties, pooling integration services, and adopting new transmission scheduling practices. Such practices can be examined by the decision tool developed by this project. This project developed a very efficient decision tool called Wind INtegration Simulator (WINS) and applied WINS to facilitate wind energy integration studies. WINS focused on augmenting the existing power utility capabilities to support collaborative planning, analysis, and wind integration project implementations. WINS also had the capability of simulating energy storage facilities so that feasibility studies of integrated wind energy system applications can be performed for systems with high wind energy penetrations. The development of WINS represents a major expansion of a very efficient decision tool called POwer Market Simulator (POMS), which was developed by IIT and has been used extensively for power system studies for decades. Specifically, WINS provides the following superiorities; (1) An integrated framework is included in WINS for the comprehensive modeling of DC transmission configurations, including mono-pole, bi-pole, tri-pole, back-to-back, and multi-terminal connection, as well as AC/DC converter models including current source converters (CSC) and voltage source converters (VSC); (2) An existing shortcoming of traditional decision tools for wind integration is the limited availability of user interface, i.e., decision results are often text-based demonstrations. WINS includes a powerful visualization tool and user interface capability for transmission analyses, planning, and assessment, which will be of great interest to power market participants, power system planners and operators, and state and federal regulatory entities; and (3) WINS can handle extended transmission models for wind integration studies. WINS models include limitations on transmission flow as well as bus voltage for analyzing power system states. The existing decision tools often consider transmission flow constraints (dc power flow) alone which could result in the over-utilization of existing resources when analyzing wind integration. WINS can be used to assist power market participants including transmission companies, independent system operators, power system operators in vertically integrated utilities, wind energy developers, and regulatory agencies to analyze economics, security, and reliability of various options for wind integration including transmission upgrades and the planning of new transmission facilities. WINS can also be used by industry for the offline training of reliability and operation personnel when analyzing wind integration uncertainties, identifying critical spots in power system operation, analyzing power system vulnerabilities, and providing credible decisions for examining operation and planning options for wind integration. Researches in this project on wind integration included (1) Development of WINS; (2) Transmission Congestion Analysis in the Eastern Interconnection; (3) Analysis of 2030 Large-Scale Wind Energy Integration in the Eastern Interconnection; (4) Large-scale Analysis of 2018 Wind Energy Integration in the Eastern U.S. Interconnection. The research resulted in 33 papers, 9 presentations, 9 PhD degrees, 4 MS degrees, and 7 awards. The education activities in this project on wind energy included (1) Wind Energy Training Facility Development; (2) Wind Energy Course Development.

17 WIND ENERGY↗