Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPACTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Analysis of Compact Cylindrical Wire Array Implosions with Brass and also by Alternating Brass and Al wires on the 1-MA COBRA Generator

Implosions from compact cylindrical wire arrays (CCWA) with mid-Z and low-Z wires were carried out on the 1-MA COBRA generator at Cornell University. In particular, the CCWA used either Brass 310 (70% Cu, 30% Zn) wires or a combination of Brass 310 and Al 5056 (95% Al, 5% Mg) wires arranged in an alternating pattern. A total of 16 wires were used on either a 6 or 4 mm diameter array. The diagnostic suite included a bolometer, fast x-ray detectors, a time-integrated spectrometer, and a streak camera. A higher energy output was observed from bolometer measurements when alternating the brass and Al wires compared to using only the brass wires. This study will focus mainly on the spectroscopy of the brass and alternating brass and Al CCWA by applying the non-LTE kinetic models of Cu and Zn to account for the L-shell radiation. The resulting plasma parameters, electron density and electron temperature, will be discussed and compared for the CCWA with only brass wires and alternating brass and Al wires. The simulations with the novel Wire Ablation Dynamics Model that account for wire ablation will be performed to analyze the differences in implosion dynamics of the uniform and alternating compact cylindrical arrays.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling of K-Shell Al and Mg and L-Shell Mo Radiation from Compact Cylindrical Wire Array Plasmas Produced on the 1 MA UNR Zebra Generator

K-shell radiation of Al and Mg and L-shell radiation of Mo from implosions of compact cylindrical wire arrays (CCWA) on the 1 MA UNR Zebra generator was studied. Specifically, radiation from implosions of 3 and 6 mm CCWA with (16-24) Al-5052 (95% Al and 5% Mg) and Al-5052 (97.5% Al and 2.5% Mg) and Mo wires was analyzed using the full set of diagnostics: PCD and current signals, and X-ray pinhole images and spectra. Previously developed non-LTE models were applied to model spatially resolved time integrated as well as time-gated spatially integrated spectra from Al, Mg, and Mo plasmas. Derived electron temperature and density spatial gradients as well as percentage of radiating mass were studied and compared. In addition, the novel Wire Dynamics Model (WDM) was used to analyze the implosion dynamics of compact wire array loads.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements from a Compact Cost-Effective Beamline for the THC14 PET Cyclotron

The THC14 PET Cyclotron produced by THALES specifies two compact cost-effective beamlines for high current PET radioisotope production. The design and development of the beamline system was reported previously in NIM B 261 (2007) pp 809-812. This paper describes the successful testing of this compact beamline at the first installation. A series of measurement data are presented starting from low current scintillator image data, higher current beam diagnostic data (baffles, collimators, targets) and finally a simultaneous dual beam run on Faraday Cups. The beamline system has proven to be a flexible and valuable tool for optimizing high current beam intensity distribution on target in a well-instrumented manner. This ability to tailor the beam characteristics for the target is particularly important as high power targets are developed which can handle very high beam currents.

43 PARTICLE ACCELERATORS↗

Sealed operation of a rf driven ion source for a compact neutron generator to be used for associated particle imaging

We present the recent development of a prototype compact neutron generator to be used in conjunction with the method of associated particle imaging for the purpose of active neutron interrogation. In this paper, the performance and device specifications of these compact generators that employ rf driven ion sources will be discussed. Initial measurements of the generator performance include a beam spot size of 1 mm in diameter and a neutron yield of 2x10{sup 5} n/s with air cooling.

43 PARTICLE ACCELERATORS↗

Design and construction of a compact microwave proton source for a proton linac

A 100 MeV, 20 mA proton linear accelerator is being developed by the Proton Engineering Frontier Project at the Korea Atomic Energy Research Institute. 20 MeV acceleration system using radio frequency quadrupole and drift tube linac was already developed and has been tested. To operate this acceleration system with a long time, more reliable proton source is needed. A compact microwave proton source was proposed and has been designed and constructed as a prototype ion source for the 100 MeV proton linear accelerator. The design of microwave power injection system is based on the microwave proton injector at LANL and CEA. The wave power from a 2.45 GHz, 2 kW magnetron source is introduced into a compact plasma chamber with 7 cm diameter and 5 cm length through a standard tapered, double-ridged waveguide (WRD250) and a quartz window. The microwave power supply is installed on high voltage platform. Axial magnetic fields up to 1 kG can be provided with a water-cooled solenoid coil. A single-hole three electrode extraction system is designed for an extraction current up to 30 mA at a 50 kV extraction voltage. The design and initial operations of the proton source are presented.

43 PARTICLE ACCELERATORS↗

Constraining compactness and magnetic field geometry of X-ray pulsars using pulse profile statistics

We use the statistics of 131 X-ray pulsar light curves in order to constrain the neutron star compactness and the inclination of the magnetic dipole. The X-ray pulse profiles are classified according to the number of pulses seen during one period, dividing them into two classes, single- and double-peaked. The relative fraction of pulsars in these classes is compared with the probabilities predicted by a theoretical model for different types of pencil-beam patterns. Our results show that a statistic of pulse profiles does not constrain compactness of the neutron stars. In contrast to the previous claim, the data do not require the magnetic inclination to be confined in a narrow interval but instead the magnetic dipole can have arbitrary inclinations to the rotational axis. The observed fractions of different types of light curves can be explained by taking into account the X-ray detector sensitivity (i.e. detection threshold for weak pulses), which decreases the fraction of the observed double-peaked light curves.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cooling of Compact Stars with Quark-Hadron Mixed Phase in the Colour Superconductive State

Recently, the central source of Cassiopeia A (Cas A) has been observed, which indicates that the star has large mass and high effective temperature. We suspect that the compact object cools by the standard neutrino emission. We assume that the compact object contains quark matter with colour superconductivity and calculate cooling curves. Considering the Quark-Hadron Mixed Phase, we obtain cooling curves which are found to be consistent with the observations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Proposed High-Energy, Compact, Optical Electron Accelerator Based on Particle Acceleration by Stimulated Emission of Radiation

A new type of advanced accelerator is proposed that is capable of producing high-energy electron beams in a compact geometry, but does not require a high-power laser beam driver nor a linear accelerator. Moreover, it is capable of generating its own microbunched electron beam source and, thus, an electron gun is also not needed. Hence, this has the potential to enable development of compact, high-energy accelerators that are less complex and less costly.

43 PARTICLE ACCELERATORS↗

Cold quark matter in astrophysics of compact stars

The appearance of quark matter in the centers of compact stars has a number of astrophysical implications. In this contribution I discuss the structure and stability of compact stars, gravitational radiation from non-axisymmetric deformations, and nucleation and dynamics of vortices (flux tubes) in the color superconducting phases.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modified magnetic field distribution in relativistic magnetron with diffraction output for compact operation

A modified magnetic field distribution in relativistic magnetron with diffraction output (MDO) for compact operation is proposed in this paper. The principle of how the modified magnetic field confines electrons drifting out of the interaction space is analyzed. The results of the particle-in-cell (PIC) simulations of the MDO with the modified magnetic field distribution show that the output power of the MDO is improved, and the long cylindrical waveguide used for collecting the drifting electrons can be omitted. The latter measure allows the horn antenna of the MDO to produce more focused energy with better directivity in the far field than it does with the long cylindrical waveguide. The MDO with the modified magnetic field distribution promises to be the real most compact narrow band high power microwave source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact post-acceleration scheme for laser-generated protons

Protons generated by irradiating a thin metal foil with a high-intensitylaser have shown to posses interesting characteristics in terms of energy, emittance, current, and pulse duration. Therefore, in the near future, they might become a competitive source with respect to conventional proton sources. Previous theoretical, numerical, and experimental studies have already demonstrated efficient coupling between laser-accelerated proton beams with traditional radio frequency (RF)-based particle accelerators. These hybrid proton accelerators benefit from both the excellent properties of the laser-based source and the flexibility, reliability, and know-how of beam handling as provided by RF-based accelerator structures. In this paper, state of the art experimental results of laser-accelerated proton beams are used as input for a numerical study using compact and innovative conventional accelerator structures designed for medical applications. Results show that this compact hybrid accelerator allows even more efficient capture and acceleration of the laser-generated proton beam.

43 PARTICLE ACCELERATORS↗

Modeling of early stages of island growth during pulsed deposition: Role of closed compact islands

After a brief review of recent modeling of growth during Pulsed Laser Deposition (PLD), we present the study of a role of adatom interactions on growth of surface islands during PLD in submonolayer regime. We employ kinetic Monte Carlo simulation with reversible growth. Attachment of monomers to islands is irreversible at low temperatures while it becomes reversible at higher temperatures, small islands become unstable with growing temperature. In the case of real system we have to take into account not only diffusion of monomers but also diffusivity of dimers and larger clusters and theirs stability. Our new code allows us to study processes which proceed on different time scales which are typical in PLD experiments: fast deposition (on scale order of 10{sup -5} s) during individual pulses, and relaxation of a system between pulses (on scale order of 0.1 s). We calculate and compare the temperature dependence of island density for two modes pulsed deposition and continuous Molecular Beam Epitaxy (MBE) growth. The island densities in PLD mode are substantially higher than in MBE mode, provided the temperature is sufficiently high. In the case of PLD, we observe anomalous temperature dependence of the island density in a certain temperature interval. It is due to the interplay between a cluster decay time and an interval between pulses. The cluster decay time depends not only on temperature but also on clusters size and shape. The anomalous behavior is caused by the temperature limited stability of the closed--compact clusters. This scenario was revealed for the simplified model with only nearest-neighbor interaction. Now, it is elucidated further and we also include interaction to second and third neighbors. We analyze role of the closed-compact surface island in kinetics of both growth modes. Furthermore, by varying interactions energies, diffusion barrier and parameters of deposition, we compare results of simulations with the PLD experiment for Fe/Mo system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improved Scintillator Materials for Compact Electron Antineutrino Detectors

Developments in the fields of chemistry and materials science provide new components that hold the potential to improve the performance of liquid scintillation electron antineutrino detectors used for the monitoring of nuclear reactors. New compounds can provide for more efficient, stable, and safer operation of these detectors. Current detectors and their detector materials raise issues regarding size, quantum efficiency, stability, and spatial resolution for the vertex detection. For compact detectors (1 m{sup 3} active volume) improvement of these issues with existing liquid scintillation cocktails can be obtained by means of developing stable and efficient neutron capture agents. These agents comprise of boron or lithium containing coordination compounds, in addition advances in fluorescence detection technologies and optimization of solvent characteristics can improve the overall efficiency. Focus points of the new detector material design are to enable a compact, robust, and direction sensitive electron antineutrino detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact AMS System At Yamagata University

A new compact accelerator mass spectrometry (AMS) system has been installed in the Kaminoyama research institute at Yamagata University. The AMS system is based on a 0.5 MV Pelletron accelerator developed by National Electrostatics Corp. The performance of the system was investigated using C series samples (C1-C8), standard samples (HOxII), and reagent graphite without any chemical treatment. The precision of {sup 14}C measurements for the standard samples is typically higher than 0.3%. The ratio of {sup 14}C to {sup 12}C is less than 6x10{sup -16} for the reagent graphite. In this paper, we present the performance of the new compact AMS system, as well as of the fully automated 20-reactor graphite lines equipped at the research institute.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High resolution, large field of view x-ray differential phase contrast imaging on a compact setup

X-ray grating interferometry is a well established technique to perform differential phase contrast imaging on conventional x-ray tubes. So far, the application of this technique in commercial micro computed tomography scanners has remained a major challenge due to the compact setup geometry. In this letter, we report on the design of a compact imaging setup using a microfocus source. Due to the extreme wave front curvature, the gratings are fabricated on a flexible substrate, enabling precise cylindrical shaping. A laboratory setup and a modified SCANCO {mu}CT100 scanner have been built, allowing high resolution and large field of view imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a compact permanent magnet helicon plasma source for ion beam bioengineering

A compact helicon plasma source was developed as a millimeter-sized ion source for ion beam bioengineering. By employing a stacked arrangement of annular-shaped permanent magnets, a uniform axial magnetic flux density up to 2.8 kG was obtained. A cost effective 118 MHz RF generator was built for adjusting forward output power from 0 to 40 W. The load impedance and matching network were then analyzed. A single loop antenna and circuit matching elements were placed on a compact printed circuit board for 50 {Omega} impedance matching. A plasma density up to 1.1 x 10{sup 12} cm{sup -3} in the 10 mm diameter tube under the magnetic flux density was achieved with 35 W applied RF power.

43 PARTICLE ACCELERATORS↗

A compact P-band coaxial relativistic backward wave oscillator with only three periods slow wave structure

A compact P-band coaxial relativistic backward wave oscillator (BWO) with only three periods slow wave structure (SWS) is investigated both theoretically and numerically. The characteristics of the coaxial SWS are analyzed when the SWS is changed from the structure with only outer conductor ripple to the structure with both inner and outer conductor ripples. It is found that the existence of the inner conductor ripple can reduce the period length of coaxial SWS to maintain the same operating frequency of the BWO and can largely increase the temporal growth rate and the spatial growth rate of the device. Then, the effects of SWS period numbers on the generation of the microwave in the P-band relativistic BWO are studied by PIC simulations. The results show that three periods SWS cannot only make the device more compact but also has a wide region of single-frequency operation and relatively large efficiency and output power in a wide range of the diode voltage. Typical simulation results show that, with a 585 kV and 7.85 kA electron beam guided by a 0.8 T solenoidal field, the microwave of 1.65 GW is generated at the frequency of 900 MHz, and the interaction efficiency is about 36%. Compared with the conventional P-band coaxial relativistic BWO with five periods SWS, the axial length of the SWS is reduced by about one half, which is only 38.4 cm, and the saturation time of the microwave signal is reduced by about 10 ns.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Passive compact molten salt reactor (PCMSR), modular thermal breeder reactor with totally passive safety system

Design Study Passive Compact Molten Salt Reactor (PCMSR) with totally passive safety system has been performed. The term of Compact in the PCMSR name means that the reactor system is designed to have relatively small volume per unit power output by using modular and integral concept. In term of modular, the reactor system consists of three modules, i.e. reactor module, turbine module and fuel management module. The reactor module is an integral design that consists of reactor, primary and intermediate heat exchangers and passive post shutdown cooling system. The turbine module is an integral design of a multi heating, multi cooling, regenerative gas turbine. The fuel management module consists of all equipments related to fuel preparation, fuel reprocessing and radioactive handling. The preliminary calculations show that the PCMSR has negative temperature and void reactivity coefficient, passive shutdown characteristic related to fuel pump failure and possibility of using natural circulation for post shutdown cooling system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗