Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMFORT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Quantifying Occupant Health and Productivity for Deep Retrofits: Beyond Traditional IEQ Studies

As energy-efficiency standards for both new construction and existing building renovations become more stringent, further reductions become less tractable and more expensive. With increasing interest and rising investment in healthy built environments, integrating energy efficiency with improved occupant experience (i.e., health, comfort, and work performance) offers a new path to drive deep energy retrofits. However, the difficulty in quantifying and verifying health and productivity gains from building upgrades leads to lower valuation of human benefits in practice. Building codes and standards have progressive energy targets but often give minimum requirements to occupant health for factors such as ventilation and thermal comfort. State and federal laws in the United States that govern the energy service performance contract (ESPC) have no clear and consistent guidance on quantifying non-energy benefits and incorporating them into a formal cost-effectiveness analysis. This paper presents a methodology to measure a building’s potential performance improvement regarding occupant health based on existing evidence correlating IEQ to occupant outcomes. Health improvement measures are integrated with a building energy model to identify and measure the impact of holistic improvement strategies. The net present value of these measures is determined based on the investment costs required to attain those improvements, energy savings, and personnel gains. We will discuss results from one pilot building, which showed nearly $50 per square foot 20-year net present value using the integrated approach.

Keene, Kevin M.↗

Human-automated vehicle interactions

This dissertation is proposed to answer the question: how can the interactions between human and automated vehicles be used to improve the overall performance of automated driving technology? Multiple different modules in automated vehicles such as the perception, motion plan and motion control modules can potentially be benefitted from human-automated vehicle interactions. For perception module, the self-correction of faulty sensors can be achieved using human demonstration data. For motion plan and motion control modules, the performance of the low-level motion controller can be improved with the help of human demonstration, and the behavior of the motion planner can be improved using human intervention data during automated driving. Moreover, a better model for a human driver could improve the overall efficiency and comfort of vehicles in connected mixed traffic. In this dissertation, the technical research toward these goals has been completed and has resulted in several peer-reviewed publications. Optimization methods and model predictive control are used extensively to improve energy efficiency while maintaining safe and comfort driving. An inverse model predictive control (IMPC) method has been developed and it has been proven to be effective in modeling the motion of human driven vehicles. The proposed method has demonstrated its benefits in both connected automated highway driving and the bilateral adaptation of human driver and automated driving controller in human-in-the loop simulations. The proposed future research seeks to broaden the application of IMPC by considering a more comprehensive cost function design and applying it to more complex driving situations.

Guo, Longxiang↗

HUMAN-AUTOMATED VEHICLE INTERACTIONS

This dissertation is proposed to answer the question: how can the interactions between human and automated vehicles be used to improve the overall performance of automated driving technology? Multiple different modules in automated vehicles such as the perception, motion plan and motion control modules can potentially be benefitted from human-automated vehicle interactions. For perception module, the self-correction of faulty sensors can be achieved using human demonstration data. For motion plan and motion control modules, the performance of the low-level motion controller can be improved with the help of human demonstration, and the behavior of the motion planner can be improved using human intervention data during automated driving. Moreover, a better model for a human driver could improve the overall efficiency and comfort of vehicles in connected mixed traffic. In this dissertation, the technical research toward these goals has been completed and has resulted in several peer-reviewed publications. Optimization methods and model predictive control are used extensively to improve energy efficiency while maintaining safe and comfort driving. An inverse model predictive control (IMPC) method has been developed and it has been proven to be effective in modeling the motion of human driven vehicles. The proposed method has demonstrated its benefits in both connected automated highway driving and the bilateral adaptation of human driver and automated driving controller in human-in-the loop simulations. The proposed future research seeks to broaden the application of IMPC by considering a more comprehensive cost function design and applying it to more complex driving situations.

Guo, Longxiang↗

Long-term trends in connected thermostat performance

Internet-connected thermostats (CTs) control heating and cooling systems in about 30% of North American homes, and capture half of annual thermostat sales. In 2017 the U.S. Environmental Protection Agency created a program to certify the performance of ENERGY STAR® Connected Thermostats. To demonstrate compliance with energy-saving criteria, thermostat vendors must submit performance summaries for a representative sample of up to 1250 homes. Vendors must then re-submit results from a new, representative sample every six months in order to maintain their ENERGY STAR certification. This procedure has created a unique record of each thermostat’s long-term performance in response to changes in weather, customer demographics, building stock, and algorithms. Our analysis covers submissions from 13 different vendors, who submitted data up to 7 times over four years. We found that these semi-annual samples generated relatively stable trends for comfort temperatures and Heating, Ventilating and Air Conditioning (HVAC) runtimes over the study period. However, some vendors achieved consistently more energy-conserving comfort temperatures and shorter HVAC runtimes than others. The most recent submission runtimes averaged 700 hours for heating and 1,300 hours for cooling, but some vendors achieved runtimes as much as 17% below the mean. This implies lower energy consumption is due in large part to more successful algorithms and control strategies used by those vendors.

Meier, Alan↗

What does it take to “see” air leakage through a building envelope?

Unwanted air leakage in buildings can cause health and comfort issues for the building occupants and contribute to rot and mold growth in building materials. Leakage also contributes to unnecessary energy consumption ~4 quads (1172 TWh) per year in the buildings sector in the United States. Finding and repairing leaks through the building envelope can improve the energy efficiency, comfort, air-quality, and moisture durability of the building stock. Typical methods of locating air leakage, such as infrared imaging or smoke tracing, rely on concurrent blower door operation which also measures the total leakage rate of the building. These methods can be disruptive to occupants and can’t measure the contribution of individual leaks to prioritize sealing efforts. ORNL is working on a refraction-based fluid flow imaging technique that can measure the leakage rate of individual leaks from the outside of the building. The working principle of this device is based on the refraction of light caused by the exfiltration because there is a small difference in density between the exfiltration and ambient air. We will discuss the operation of the air leak detector and key variables that affect its performance. We will also present preliminary results showing the visualization capability of this new air leak detector under different conditions. Experiments were completed with different claddings, air temperatures, and lighting conditions.

Boudreaux, Philip↗

Two-point and multiple-point spot heating and cooling

Apparatus and methods for producing thermal comfort using two point or multipoint heating or cooling that is applied to portion of a human body part to produce a warm or cool sensation over a larger area than that where the heating or cooling is directly applied. The body is induced to heat or cool itself by adjusting its neutral temperature setpoints. Increased warming perception from two-point, multipoint, and switching point stimulation causes downward adaptation in the neutral skin temperature of the user. Because spot heating and cooling sources operate at higher temperature differences from the skin than do area sources, they create a stronger perceived thermal sensation for the same power consumption. Point heating or cooling, rather than whole-area heating, can result in power savings and cost savings while improving occupant comfort.

Arens, Edward↗

The Telbot master-arm

It is the weight lifter with maximum flexibility: The TELBOT provides high capacity and infinite rotary motion across all axes. Special jobs call for a special robot: The TELBOT from Waelischmiller Engineering. The TELBOT particularly shows its strength in places where human operators cannot work and heavy work has to be done. For example in the nuclear industry or chemical plants. The TELBOT is a multifunctional, modular and automated robotic system with unique characteristics: no cable in or on the TELBOT-arms for unlimited, fast and precise arm motions as well as maximum efficiency and highest comfort; smooth, sealed arm and joint bodies ensure maximum radiation resistance, making the TELBOT robot the perfect helper for the nuclear sector; the TELBOT can not only be utilised for an extremely long time but is also maintenance-free and easy to decontaminate. They therefore represent an investment that will still pay out in 30 years time; sophisticated engineering skill is apparent not least in the slim design with no loss of high capacity; tools can be remotely controlled with extreme precision and the high repeat accuracy and simple implementation of complex processes ensure trouble-free and intuitive operation; programmed motion sequences bring with them noticeably comfortable and speedy operation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Simple Panel System to Overcome Interface Challenges for Retrofits: Preprint

Retrofitting buildings is usually an expensive and labor-intensive process. Weatherization measures can improve comfort and energy affordability to some extent, but deep energy retrofits are needed to optimize performance and comfort, and to achieve significant energy cost savings. Barriers to deep energy retrofits include a limited supply of skilled labor, different building types, planning complexity, split incentives, and a long or non-existent ROI horizon. The "Simple Panel System" (SPS) workflow developed and demonstrated in this effort streamlines deep energy retrofits by applying advanced site capture, machine learning, and mixed reality to panelized construction. The result is a one-stop, product-independent solution for rapidly scalable retrofits with the potential to reduce construction time and project costs by 50%. Soft costs are reduced by more than 66%, total costs by more than 50%, and field construction time by more than 50% - not to mention the reduction in construction waste, improvement in working conditions, and the ability to scale without an influx of skilled labor. This paper presents the SPS and the preliminary results and findings from the pilot project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-density thermal sensitivity maps of the human body

‘Personal comfort systems’ and thermally active clothing are able to warm and cool individual building occupants by transferring heat directly to and from their body surfaces. Such systems would ideally target local body surfaces with high temperature sensitivities. Such sensitivities have not been quantified in detail before. Here we report local thermal sensations and sensitivities for 318 local skin spots distributed over one side of the body, measured on a large number of subjects. Skin temperature changes were induced with a thermal probe 14 mm in diameter, and subjective thermal sensations were surveyed after 10 s. Our neutral base temperature was 31 °C and the spot stimulus was ±5 °C. Cool and warm sensitivities are seen to vary widely by body part. The foot, lower leg and upper chest are much less sensitive than average; in comparison, the cheek, neck back, and seat area are 2–3 times as sensitive to both cooling and warming stimuli. Every body part exhibits stronger sensitivity to cooling (1.3–1.6 times stronger) than to warming. Inter-personal differences and regional variance within body parts were observed to be 2–3 times greater than potential sex differences. These high-density thermal sensitivity maps with appended dataset provide the most comprehensive distributions of cold and warm sensitivity across the human body.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Strategy Guideline: Air Distribution Basics and Duct Design

This report discusses considerations for designing an air distribution system for an energy efficient house that requires less air volume to condition the space. Considering the HVAC system early in the design process will allow adequate space for equipment and ductwork and can result in cost savings. Principles discussed that will maximize occupant comfort include delivery of the proper amountof conditioned air for appropriate temperature mixing and uniformity without drafts, minimization of system noise, the impacts of pressure loss, efficient return air duct design, and supply air outlet placement, as well as duct layout, materials, and sizing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

National energy savings potential of cellular shades: A measurement and simulation study

Windows are major contributors to energy demand in residential homes because of their inferior thermal resistance compared with the opaque envelope, and sometimes from unwanted solar heat gain. Window attachments can help mitigate the energy demand by controlling the solar heat gains and enhancing window thermal resistance. Cellular shades have the potential of superior thermal performance compared with generic shades because of its honeycomb structure. Here, in this study, the team analyzed the energy savings potential of cellular shades in residential homes via experimental testing for two heating seasons and energy simulations. Five shading devices—three single-cell and two double cellular/cell-in-cell shades—were used to compare the performance with generic horizontal venetian blinds using two nearly identical side-by-side rooms in a residential home. The experimental testing showed daily heating energy savings in the range of 17%–36% compared with the case without shades. The experimental testing data also exhibited improvements in thermal comfort when using cellular shades. Additionally, energy simulations were performed to evaluate the energy savings potential of the cellular shades using a residential prototype home, which demonstrated energy savings up to 9 kWh/m2/year in cold climates. The total site energy savings for heating and cooling from cellular shades was up to ~9% for the home with a heat pump and up to ~15% for a home with a gas furnace compared with cases without any shading devices. The energy savings at a national scale were up to 14.6 TWh assuming a 20% penetration rate in residential homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Benefits assessment of cool skin and ventilated cavity skin: Saving energy and mitigating heat and grid stress

This study assessed the energy-saving and climate-adaptive potential of cool skin and ventilated cavity skin facade technologies in Seoul's high-rise apartment buildings. We created weather scenarios for historical, mid-term future, and long-term future conditions using Coordinated Regional Downscaling EXperiment (CORDEX) method. Building energy simulations were conducted on a South Korean high-rise apartment model to evaluate their performance under different weather conditions. The results indicate that cool skin and ventilated cavity skin technologies can save cooling energy during summers but lead to heating energy penalties in winters. Ventilated cavity skin outperforms cool skin, offering better cooling energy savings and reduced heating penalties. Combining both technologies yields the highest overall energy savings, with 7 %, 9 %, and 10 % cooling energy savings for cool skin, ventilated cavity skin, and the combined package, respectively. However, cool skin increases heating energy consumption by 5 %, while ventilated cavity skin has minimal impact on heating energy. These envelope technologies also reduce peak electricity demand by at least 5 %, 8 %, and 9 %, respectively. They contribute to heat stress reduction, enhance resilience, and decrease extreme heat risks for occupants during power outages by at least 18 % under various weather conditions. Considering the prevalence of aging high-rise apartments in South Korea, adopting these envelope renovation strategies can effectively reduce cooling loads, enhance thermal comfort, and boost resilience under future climates, while avoiding costly reconstruction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Observations of airflow around a supertall curved building and its impact on temperature and humidity in Houston's urban center

Characterization of realistically shaped skyscrapers embedded in non-uniform neighbourhoods experiencing intricate weather patterns remains inadequately investigated. Aiming to close this gap, the Center for Multiscale Applied Sensing team deployed its mobile observatory in the street canyons around the curved Wells Fargo Plaza skyscraper in downtown Houston, TX. Three deployments allowed airflow observations under different inflow wind and thermodynamic stability conditions. Doppler lidar measurements reveal that when inflow hits the curved wall of the skyscraper, perpendicular canyons experience similar vortex configurations creating two windward and two leeward circulations. Windsond measurements support that buoyancy within the deep street canyons can generate thermal updrafts as strong as 2 m s -1 which is sufficient to overturn the mechanical downwash under gentle wind conditions. Canyons experiencing venting during the daytime were observed to be more thermodynamically stable at night while thermodynamically stable canyons during the day were observed to be more thermodynamically unstable at night owing to the accumulation of heat near street-level. Fourier decomposition of the vertical velocity measurements shows that in all cases flow exhibited high Reynolds numbers and was composed of turbulent eddies of predominantly 6 and 15 min periods. Here, this observational dataset provides insights to assess wind load, pedestrian comfort, urban air mobility, and natural ventilation and may be used as a benchmark for numerical model and wind tunnel studies attempting to represent realistically complex urban conditions.

54 ENVIRONMENTAL SCIENCES↗

Multi-criteria thermal resilience certification scheme for indoor built environments during heat waves

With climate change, the indoor built environment is expected to significantly influence the occupant's safety and well-being. A novel multi-criteria thermal resilience certification scheme for indoor built environments during extreme heat events is proposed in this paper. The certification scheme considers overheating, thermal comfort, heat stress, and hygrothermal discomfort in built environments. These criteria are quantified using key performance indicators like indoor overheating degree, hours of exceedance, wet-bulb globe temperature, and heat index, respectively. This scheme is developed based on existing best practices like standards, rating systems, and literature. The scheme is implemented on a benchmark building energy performance model for detached post-World War II dwellings in Belgium as a case study using weather data measured from the City of Brussels. The indoor overheating in the reference dwelling is assessed with a static threshold of 27 °C for the bedrooms and adaptive thresholds for other areas. The analysis found that the building performance is within the defined threshold levels throughout the heat wave duration for all criteria. Therefore, the reference dwelling got a maximum attainable score of four points and is rated five-star for thermal resilience during heat waves. The proposed certification scheme is intended as a standardized framework and highlights the need for further revisions in building performance policies and guidelines.

Climate change↗

The impact of TXV heating on the performance of air-source heat pump in heating mode

The paper discusses the strategy of TXV heating, which adds a limited amount of heat on the surface of TXV sensor, to achieve energy saving and low cost in air-source heat pumps. The TXV heating is able to retard the valve closing so as to boost energy saving in heating mode. The testing results demonstrate the appropriate TXV heating achieves a remarkable improvement in COP and thermal comfort. The required heating power is not more than 40w. The additional equipment cost of TXV heating is less than $20. Thus, the strategy of TXV heating is practical from the view of technology and economy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Printable, emissivity-adaptive and albedo-optimized covering for year-round energy saving

Radiative cooling uses high-emissivity materials to passively cool the surface of outdoor objects, such as building roofs on hot days. The issue of overcooling with this technology on cold days can be addressed by structures with thermal emissivity that is adaptive to temperature. Despite recent advances in temperature-adaptive structures, great challenges remain in their fabrication feasibility and unoptimized solar heating that may override the radiative cooling benefit. Here, in this work, we develop a printable, emissivity-adaptive and albedo-optimized covering (PEAC) based on recyclable materials with roll-to-roll fabrication. A PEAC automatically switches its sky-window emissivity from 0.25 to 0.85 when the surface temperature exceeds a pre-set transition temperature, delivering an albedo optimized for maximal year-round energy saving or thermal comfort in a given climate.

36 MATERIALS SCIENCE↗

Hierarchical fuzzy control of low-energy building systems

A hierarchical fuzzy supervisory controller is described that is capable of optimizing the operation of a low-energy building, which uses solar energy to heat and cool its interior spaces. The highest level fuzzy rules choose the most appropriate set of lower level rules according to the weather and occupancy information; the second level fuzzy rules determine an optimal energy profile and the overall modes of operation of the heating, ventilating and air-conditioning system (HVAC); the third level fuzzy rules select the mode of operation of specific equipment, and assign schedules to the local controllers so that the optimal energy profile can be achieved in the most efficient way. Computer simulation is used to compare the hierarchical fuzzy control scheme with a supervisory control scheme based on expert rules. The performance is evaluated by comparing the energy consumption and thermal comfort. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential model for single-sided naturally ventilated buildings in China

The paper investigates a single-sided naturally ventilated buildings potential model considering number of factors in China. This model can be used to estimate potential of natural ventilation via local climate data and building parameters. The main goal of the model is to predict natural ventilation hours and hourly ventilation flow rate. In fluid model, formula of single-sided natural ventilation by coupling wind pressure and temperature difference was used to calculate air flow rate. Accordingly, the paper analyzed four typical cities in different climate region in China and calculated pressure difference Pascal hours (PDPH). The results show that single-sided ventilation has fewer adaptive comfort hours than two-sided ventilation and much less ventilation volume. This model provided quantitative information for early stage architectural natural ventilation design and building energy efficiency evaluation. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗