Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Properties of Roman bricks and mortars used in Serapis temple in the city of Pergamon

Serapis temple, which was constructed in the Roman period in the city of Pergamon (Bergama/Turkey), is one of the most important monuments of the world heritage. In this study, the characteristics of bricks and mortars used in the temple have been determined in order to define the necessary characteristics of the intervention materials, which will be used in the conservation works of the temple. Several analyses were carried out to determine their basic physical properties, raw material compositions, mineralogical and microstructural properties using X-ray diffraction, Scanning Electron Microscope and a Thermo Gravimetric Analyzer. Analysis results indicated that the mortars are stiff, compact and hydraulic due to the use of natural pozzolanic aggregates. The Roman bricks are of low density, high porosity and were produced from raw materials containing calcium poor clays fired at low temperatures.

36 MATERIALS SCIENCE↗

Exploring Micro-Environmental Conditions of Urban Agrivoltaics: Advancing Sustainable Green Spaces and Agriculture in Temperate Cities

Agrivoltaics, the integrated land use combining renewable energy production and agriculture, can potentially address key challenges faced by urban communities, including limited access to vacant land, fresh produce, and electricity. However, urban agrivoltaics has rarely been considered a viable solution, primarily due to a lack of experimental systems demonstrating the functionality of urban food production or green spaces alongside solar energy production. To evaluate the potential of solar photovoltaics to help mitigate heat stress on urban agriculture and green spaces in a temperate climate, we examined the microclimatic changes introduced by an urban agrivoltaics system (UrAV) when combined with vegetable crops and turfgrass, respectively. Accordingly, we installed an experimental setup instrumented with environmental sensors to compare full-sun conditions with those of an agrivoltaics system designed for urban environments. We found minimal differences for both land cover types between the control and agrivoltaics sites in air and soil temperature. However, during periods of intensified summer heat, temperatures beneath the panels cooled due to reductions in wind speed and relative humidity, which impeded the movement of hot, moist air and reduced reference evapotranspiration. Further, soil moisture in UrAV was highly spatially heterogeneous, influenced by the layout of the photovoltaic panels and their support structure, which redistributed rainfall and controlled where solar radiation could penetrate and drive evapotranspiration. Overall, our results suggest that PV-induced environmental changes in temperate climates are compatible with cultivating turfgrass or appropriate crops. These findings can help planners and designers integrate agrivoltaics into community gardens, farms, and green spaces in temperate cities.

14 SOLAR ENERGY↗

Comparative study of different solar cooling systems for buildings in subtropical city

In recent years, more and more attention has been paid on the application potential of solar cooling for buildings. Due to the fact that the efficiency of solar collectors is generally low at the time being, the effectiveness of solar cooling would be closely related to the availability of solar irradiation, climatic conditions and geographical location of a place. In this paper, five types of solar cooling systems were involved in a comparative study for subtropical city, which is commonly featured with long hot and humid summer. The solar cooling systems included the solar electric compression refrigeration, solar mechanical compression refrigeration, solar absorption refrigeration, solar adsorption refrigeration and solar solid desiccant cooling. Component-based simulation models of these systems were developed, and their performances were evaluated throughout a year. The key performance indicators are solar fraction, coefficient of performance, solar thermal gain, and primary energy consumption. In addition, different installation strategies and types of solar collectors were compared for each kind of solar cooling system. Through this comparative study, it was found that solar electric compression refrigeration and solar absorption refrigeration had the highest energy saving potential in the subtropical Hong Kong. The former is to make use of the solar electric gain, while the latter is to adopt the solar thermal gain. These two solar cooling systems would have even better performances through the continual advancement of the solar collectors. It will provide a promising application potential of solar cooling for buildings in the subtropical region. (author)

14 SOLAR ENERGY↗

Modeling potential air temperature reductions yielded by cool roofs and urban irrigation in the Kansas City Metropolitan Area

In this work, we evaluate two mitigation strategies for urban heat island (UHI) in the Kansas City Metropolitan Area (KCMA). Using the Weather Research and Forecasting (WRF) model, we assess the potential benefits of reflective “cool” roofs and urban irrigation on air temperature in typical summer conditions between 2011 and 2015, and during six of the strongest historical heat waves from 2005 to 2016. Under the typical summer conditions, we simulate 2-m air temperature for 10 summer weeks, finding average daytime (07:00–19:00 local time) temperature reductions of 0.08 and 0.28 °C for cool roofs and urban irrigation, respectively. During the six heat-wave episodes, we find daytime temperature reductions of 0.02 and 0.26 °C for the two scenarios, similar to those under typical summer conditions. Our results suggest that urban irrigation can be more efficient than cool roofs in mitigating UHI in metropolitan regions where the majority of the land cover is comprised of areas with low urban (i.e., non-vegetated) fractions. Finally, we find the alteration of surface conditions due to enhanced roof albedos influences precipitation within the WRF simulation, in particular during the heat waves. Further research would be necessary to determine the robustness of this last finding.

54 ENVIRONMENTAL SCIENCES↗

Household waste disposal in Mekelle city, Northern Ethiopia

In many cities of developing countries, such as Mekelle (Ethiopia), waste management is poor and solid wastes are dumped along roadsides and into open areas, endangering health and attracting vermin. The effects of demographic factors, economic and social status, waste and environmental attributes on household solid waste disposal are investigated using data from household survey. Household level data are then analyzed using multinomial logit estimation to determine the factors that affect household waste disposal decision making. Results show that demographic features such as age, education and household size have an insignificant impact over the choice of alternative waste disposal means, whereas the supply of waste facilities significantly affects waste disposal choice. Inadequate supply of waste containers and longer distance to these containers increase the probability of waste dumping in open areas and roadsides relative to the use of communal containers. Higher household income decreases the probability of using open areas and roadsides as waste destinations relative to communal containers. Measures to make the process of waste disposal less costly and ensuring well functioning institutional waste management would improve proper waste disposal.

54 ENVIRONMENTAL SCIENCES↗

Municipal solid waste management in Lahore City District, Pakistan

This study deals with generation, composition, collection, transportation, and disposal, as well as the present cost of the waste management on the basis of 60% collection of the total waste and the cost of proposed improved system of management on the basis of 100% waste collection using the IWM-2 LCI model. A GIS map of Data Ganj Bakhsh Town (DGBT) of Lahore City District showing communal storage facilities is also provided. DGBT has a population of 1,624,169 living in 232,024 dwellings. The total waste generated per year is 500,000 tons, or 0.84/kg/cap/day. Presently 60% of the MSW is collected and disposed in open dumps, while 40% is not collected and lies along roadsides, streets railway lines, depressions, vacant plots, drains, storm drains and open sewers. In DGBT, 129 containers of 5-m{sup 3} capacity, 120 containers of 10-m{sup 3} capacity and 380 skips of 2.5-m{sup 3} capacity are placed for waste collection. The overall collection and disposal cost of the MSW of DGBT is $3,177,900/yr, which is $10.29/ton. Modeling was conducted using the IWM-2 model for improved collection and disposal on the basis of 100% service, compared to the current 60% service. The modelled cost is $8.3/per ton, which is 20% less than the present cost, but the overall cost of 100% collection and disposal increases to $4,155,737/yr.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of total urban metabolism and metabolic inefficiency in an Irish city-region

This paper aims to measure product and waste flows in an Irish city-region using the principles of metabolism and mass balance. An empirical indicator to measure resource efficiency, using a ratio of waste disposal as a function of product consumption, was developed and it was found that total materials metabolic inefficiency fell by 31% from 0.13 in 1996 to 0.09 in 2002. The paper concludes by analyzing the strengths and weaknesses of this indicator and its potential application in the field of sustainable consumption and resource efficiency as well as making suggestions to improve and strengthen the indicator.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multi-criteria evaluation in strategic environmental assessment for waste management plan, a case study: The city of Belgrade

Highlights: • The paper deals with the specific method of multi-criteria evaluation applied in drafting the SEA for the Belgrade WMP. • MCE of the planning solutions, assessed according to 37 objectives of the SEA and four sets of criteria, was presented in the matrix form. • The results are presented in the form of graphs so as to be easily comprehensible to all the participants in the decision-making process. • The results represent concrete contribution proven in practice. - Abstract: Strategic Environmental Assessment (SEA) is one of the key instruments for implementing sustainable development strategies in planning in general; in addition to being used in sectoral planning, it can also be used in other areas such as waste management planning. SEA in waste management planning has become a tool for considering the benefits and consequences of the proposed changes in space, also taking into account the capacity of space to sustain the implementation of the planned activities. In order to envisage both the positive and negative implications of a waste management plan for the elements of sustainable development, an adequate methodological approach to evaluating the potential impacts must be adopted and the evaluation results presented in a simple and clear way, so as to allow planners to make relevant decisions as a precondition for the sustainability of the activities planned in the waste management sector. This paper examines the multi-criteria evaluation method for carrying out an SEA for the Waste Management Plan for the city of Belgrade (BWMP). The method was applied to the evaluation of the impacts of the activities planned in the waste management sector on the basis of the environmental and socioeconomic indicators of sustainability, taking into consideration the intensity, spatial extent, probability and frequency of impact, by means of a specific planning approach and simple and clear presentation of the obtained results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Aerosols Containing Zn, Pb, and Cl from an Industrial Region of Mexico City

During the March, 2006 MILAGRO campaign, measurements in the Northern Mexico City Metropolitan Area revealed the frequent appearance of particles with a characteristically high content of internally mixed Zn, Pb, Cl, and P. A comprehensive study of the chemical and physical properties of these particles was performed using a complementary combination of aerosol measurement techniques. Individual particles were analyzed using Aerosol Time-of-Flight Mass Spectrometry (ATOFMS) and Computer Controlled Scanning Electron Microscopy/Energy Dispersive X-Ray spectroscopy (CCSEM/EDX). Proton Induced X-Ray Emission (PIXE) analysis of bulk aerosol samples provided time-resolved mass concentrations of individual elements. The PIXE measurements indicated that Zn is more strongly correlated with Cl than with any other element and that Zn concentrations are higher than other non-ferrous transition metals. The Zn- and Pb - containing particles have both spherical and non-spherical morphologies. Many metal rich particles had needle-like structures and were found to be composed of ZnO and/or Zn(NO 3 ) 2 ∙6H 2 O as indicated by scanning transmission x-ray microscopy/near edge X-ray absorption spectroscopy (STXM/NEXAFS). The Zn and Pb rich particles were primarily in the submicron size range and internally mixed with elemental carbon. The unique chemical associations most closely match signatures acquired for garbage incineration. This unique combination of complementary analytical techniques has allowed for a comprehensive evaluation of Zn- and Pb- containing particles in a complex urban environment, highlighting unique characteristics that give powerful insight into their origin.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Correlation of Secondary Organic Aerosol with Odd Oxygen in Mexico City

Data collected from a mountain location within the Mexico City limits are used to demonstrate a correlation between secondary organic aerosol and odd-oxygen (O3 + NO2). Positive matrix factorization techniques are employed to separate organic aerosol components: hydrocarbon-like organic aerosol; oxidized-organic aerosol; and biomass burning organic aerosol. The measured hydrocarbon-like organic aerosol is correlated with urban CO (8±1) µg m-3 ppmv-1. The measured oxidized-organic aerosol is associated with photochemical oxidation products and correlates with odd-oxygen with an apparent slope of (70-120) µg m-3 ppmv-1. The dependence of the oxidized-organic aerosol to odd-oxygen correlation on the nature of the gas-phase hydrocarbon profile is discussed.

09 BIOMASS FUELS↗

Observational Constraints on the Spatial Effect of Greenness and Canopy Cover on Urban Heat in a Major Midlatitude City

Abstract Urban heat stress is a critical issue, particularly in cities where dense infrastructure and limited green space exacerbate temperature extremes. This study investigates the impact of greenery (EVI2), canopy cover (CC), impervious cover (IC), and water bodies on heat index in Chicago using high‐resolution data from the Heat Watch campaign. We find that EVI2, CC and proximity to water body significantly reduce heat while IC increases heat, particularly in the afternoon when solar radiation is intense. Additionally, the effective radius that land cover impacts heat is smaller in the afternoon. The combined effect analysis indicates that enhancing total greenness, not just canopy cover, is the most effective strategy to reduce heat. This study underscores the importance of strategic vegetation management, highlighting the critical role of integrated approaches in reducing urban heat.

Lee, Jangho↗

Increased exposure of coastal cities to sea-level rise due to internal climate variability

Adaptation to future sea-level rise is based on projections of continuously improving climate models. These projections are accompanied by inherent uncertainties, including those due to internal climate variability (ICV). The ICV arises from complex and unpredictable interactions within and between climate-system components, rendering its impact irreducible. Although neglecting this uncertainty can lead to an underestimation of future sea-level rise, its estimation and impacts have not been fully explored. Combining the Community Earth System Model version 1 Large Ensemble experiments with power-law statistics, we show that, by 2100, if the ICV uncertainty reaches its upper limit, new sea-level-rise hotspots would appear in Southeast Asian megacities (Chennai, Kolkata, Yangon, Bangkok, Ho Chi Minh City and Manila), in western tropical Pacific Islands and the Western Indian Ocean. Here, the better the ICV uncertainty is taken into account and correctly estimated, the more effective adaptation strategies can be elaborated with confidence and actions to follow.

54 ENVIRONMENTAL SCIENCES↗

Assessing and mitigating cybersecurity risks of traffic light systems in smart cities

Intelligent traffic lights are critical cyber‐physical systems that help smart cities to cut road congestion and vehicle emissions. However, they also open a new frontier of cybersecurity. Security researchers have demonstrated ways to compromise the traffic lights to cause potential traffic disruption and public safety degradation. This study aims to raise the public awareness of the cybersecurity issues in traffic light systems. The authors present a bi‐level game‐theoretic framework for assessing cybersecurity risks of traffic light systems, as the first step towards understanding and mitigating the security vulnerabilities. Additionally, they propose a minimax‐regret‐based methodology to guide the deployment of defensive measures in traffic light systems against cyberattacks.

Li, Zhiyi↗

Synthetic residential load models for smart city energy management simulations

The ability to control tens of thousands of residential electricity customers in a coordinated manner has the potential to enact system-wide electric load changes, such as reduce congestion and peak demand, among other benefits. To quantify the potential benefits of demand-side management and other power system simulation studies (e.g. home energy management, large-scale residential demand response), synthetic load datasets that accurately characterize the system load are required. This study designs a combined top-down and bottom-up approach for modelling individual residential customers and their individual electric assets, each possessing their own characteristics, using time-varying queueing models. The aggregation of all customer loads created by the queueing models represents a known city-sized load curve to be used in simulation studies. The three presented residential queueing load models use only publicly available data. An open-source Python tool to allow researchers to generate residential load data for their studies is also provided. The simulation results presented consider the ComEd region (utility company from Chicago, IL) and demonstrate the characteristics of the three proposed residential queueing load models, the impact of the choice of model parameters, and scalability performance of the Python tool.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The impact of earthquakes on the city of Aigio in Greece. Urban planning as a factor in mitigating seismic damage

This paper examines the effects of the mortal earthquake on the city of Aigio in Greece in 1995, with particular focus on urbanization and planning policies. It is based on interviews with experts and surveys on damage to buildings following this earthquake. The analysis takes into account several factors, such as exact location, land use, construction period and the height of damaged buildings. Furthermore, the relationship between the seismic damage and the postseismic construction development of Aigio is examined and the conclusion is reached that the Greek urban planning system needs to be better organized to prepare for seismic damage. To this end, the paper recommends a five-point discussion agenda for applying local planning to seismic mitigation.

58 GEOSCIENCES↗

Site Response Analysis of the Monte Po Hill in the City of Catania

The Monte Po Hill is located in the North-eastern part of the city of Catania; this area is prone to high seismic risk due to the presence of several constructions, including a school, in the vicinity of a toe of a slope, characterized by precarious stability conditions. For site characterization of the soil, deep site investigations have been undertaken. Borings and dynamic in situ tests have been performed. Among them Down-Hole (D-H) and Seismic Dilatometer Marchetti Tests (SDMT) have been carried out, with the aim to evaluate the soil profile of shear waves velocity (Vs). The Seismic Dilatometer Marchetti Tests were performed up to a depth of 15 meters. The results show a very detailed and stable shear waves profile. The shear waves profiles obtained by SDMT compare well with other in situ tests. Synthetic seismograms have been drawn for the site long a set of receivers placed at different depths, starting from the surface up to almost 40 m. After evaluating the synthetic accelerograms at the bedrock, the ground response analysis at the surface, in terms of time history and response spectra, has been obtained by a 1-D non-linear model. In particular the study has regarded the evaluation of site effects in correspondence of the site, to which corresponds a different value of the Seismic Geotechnical Hazard. In the beginning of 2007 a seismic station has been also located into the school building, with the aim of recording seismic events. Seismograms obtained by the seismic station have been also used to evaluate the ground response analysis at the surface. In the beginning of 2007 a seismic station has been also located into the school building, with the aim of recording seismic events. Seismograms obtained by the seismic station have been also used to evaluate the ground response analysis at the surface. Finally the 1-D computer code EERA was also used to model the equivalent-linear earthquake site response analyses of layered soil deposits of the hill. The detail with which the hill has been studied has allowed the construction of a detailed 2-D model of its structure. It has been explored the differences between the computed ground motion for different Vs profiles using QUAD4M 2-D code. It has been also possible to compare the results from different 1-D models reflecting current approaches to the determination of site response.

58 GEOSCIENCES↗

Implications of the In-Situ Measured Mass Absorption Cross Section of Organic Aerosols in Mexico City on the Atmospheric Energy Balance, Satellite Retrievals, and Photochemistry

The absorption of short wave incoming solar radiation by the organic component of aerosols has been examined by using data from the MCMA-2003 and the 2006 MILAGRO field campaigns. Both field efforts took place in and around Mexico City. Single Scattering Albedo (SSA) was derived as a function of wavelength (300-870 nm) by combining irradiance measurements from a Multi-Filter Rotating Shadowband Radiometer (MFRSR) and spectrally resolved actinic flux measurements by spectroradiometry with a radiative transfer model (TUV). In addition, organic aerosol mass measured by a surface deployed aerodyne aerosol mass spectrometer was used to estimate the Mass Absorption Cross-section (MAC) of Organic Carbon (OC). It was found that the MAC for OC is about 10.5 m{sup 2}/g at 300 nm and falls close to zero at about 500 nm; these values are roughly consistent with previous MAC estimates of OC, and present first in-situ observations of this quantity.

58 GEOSCIENCES↗

Downward Atmospheric Longwave Radiation in the City of Sao Paulo

This work evaluates objectively the consistency and quality of a 9 year dataset based on 5 minute average values of downward longwave atmospheric (LW) emission, shortwave radiation, temperature and relative humidity. All these parameters were observed simultaneously and continuously from 1997 to 2006 in the IAG micrometeorological platform, located at the top of the IAG-USP building. The pyrgeometer dome emission effect was removed using neural network technique reducing the downward long wave atmospheric emission error to 3.5%. The comparison, between the monthly average values of LW emission observed in Sao Paulo and satellite estimates from SRB-NASA project, indicated a very good agreement. Furthermore, this work investigates the performance of 10 empirical expressions to estimate the LW emission at the surface. The comparison between the models indicates that Brunt's one presents the better results, with smallest ''MBE,''''RMSE'' and biggest ''d'' index of agreement, therefore Brunt is the most indicated model to estimate LW emission under clear sky conditions in the city of Sao Paulo.

58 GEOSCIENCES↗