Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Beam Forming”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Higher-order space-charge stability in anisotropic beams: Vlasov-Poisson derivation, refined dispersion relations, and stability charts

The Hofmann stability chart is used to screen working points in space-charge-dominated linacs. We identify two errors in its published higher-order dispersion relations: missing $(1\mp2\hatη^2/α)$ factors in the third-order $S^4$ coupling residues, and a sign error in the stated isotropic reduction of the fourth-order relation. Both corrections follow from Hofmann's Vlasov-Poisson equations without fitted parameters. They reproduce coherent tune-shift coefficients in the author's later monograph that the printed forms miss by 24% and 127%. Mode-resolved figures from a published application agree with the corrected relations and reject the printed forms, indicating an inconsistency between the 1998 equations and the calculations underlying those tested figures. We quantify the effect on the non-oscillatory stability chart. Inside the adopted $S^2\le10$ comparison domain, printed and corrected forms disagree on 0.73-2.11% of cells, with no preferred direction. Among excluded cells, disagreement reaches 22%, and the printed relation over-predicts instability at every sampled anisotropy. This concentration may help explain why the errors persisted, although it does not establish their historical cause. For PIP-II, the corrected chart flags four of thirty-two evaluable periods, including one on a third-order odd branch missed by a second-order screen. This count covers non-oscillatory modes only and remains conditional on an unresolved factor-five disagreement between two codes on transverse emittance growth.

Pathak, Abhishek [Fermilab] (ORCID:000000021704208↗

Thermal / structural analysis of the HB 650 thermal shield

Fermilab’s PIP-II project’s superconducting linear accelerator will drive the next generation of particle accelerators through a revolution in beam intensity. Key to beam intensification are the high efficiencies of niobium-tin superconducting radiofrequency (SRF) cavities operating at cryogenic temperatures near 5 Kelvin. A multifaceted approach is employed to achieve and maintain the extreme temperature. Vacuum provides the first barrier to thermal convection. Physical thermal intercept zones further isolate the exterior shell vacuum vessel at 300 Kelvin from the supercooled beamline. The first thermal intercept lies just inside the exterior vacuum vessel forming the 40 Kelvin zone. This 40K thermal shield is the focus of this investigation. In preparation for operation, the thermal shield is cooled from 300K to 40K in a slow process over 2-1/2 days. The factors limiting the cooling rate are a high thermal gradient which produces thermal strain and high mechanical stress. D ecreasing the time required to reach operational temperatures is the desired research goal. Physical testing data and finite element method (FEM) computer models from the Single Spoke Resonator – 1 (SSR1) and Linac Coherent Light Source (LCLS-II) cryomodules will be evaluated to determine needed design changes. The thermal shield design for the High Beta 650 MHz (HB650) will be modified and analyzed using FEM computer models to determine maximum cooling rate with a target of 50 thermal cycles of life. Maximum allowable stress will be determined through low cycle fatigue calculations.

43 PARTICLE ACCELERATORS↗

Sulfur ( 3 P) Reaction with Conjugated Dienes Gives Cyclization to Thiophenes under Single Collision Conditions

Here, we combine crossed-beam velocity map imaging with high-level ab initio/transition state theory modeling of the reaction of S( 3 P) with 1,3-butadiene and isoprene under single collision conditions. For the butadiene reaction, we detect both H and H 2 loss from the initial adduct, and from reaction with isoprene, we see both H loss and methyl loss. Theoretical calculations confirm these arise following intersystem crossing to the singlet surface forming long-lived intermediates. For the butadiene reaction, these lose H 2 to form thiophene as the dominant channel, H to form the detected 2H-thiophenyl radical, or ethene, giving thioketene. For isoprene, additional reaction products are suggested by theory, including the observed H and methyl loss radicals, but also methyl thiophene, thioformaldehyde, and thioketene. The results for S( 3 P) + 1,3-butadiene, showing direct cyclization to the aromatic product and yielding few bimolecular product channels, are in striking contrast to those for the analogous O( 3 P) reaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental investigation of laser ablation of stone polycrystalline targets

We report the results of an experimental investigation of ablation of stone polycrystalline targets of complex multicomponent composition, which imitate the substance of asteroids. The targets were irradiated by nanosecond pulses of a neodymium laser at an energy density Φ{sub L} of up to 5 × 10{sup 4} J cm{sup −2}. The experiments demonstrated the existence of two ablation regimes, with the boundary between them lying at Φ{sub L} ≈ 4000 J cm{sup −2}. The regime change is characterised by a change in the form of the dependence of the surface mass density of removed target material on the laser energy density and by the appearance of a minimum in the dependence of specific energy of destruction on Φ{sub L}. This is supposedly related to the passage from a one-dimensional plasma plume expansion to the three-dimensional one and the corresponding decrease in the efficiency of energy transfer from the laser beam to the target due to a lowering of laser-produced plasma density. Our experiments also showed the existence of a maximum in impulse coupling coefficient C{sub m} as a function of laser energy density (C{sub m} ≈ 6.3 × 10{sup −5} N W{sup −1} for Φ{sub L} = Φ{sub opt} ≈ 25 J cm{sup −2}). Maxima were also recorded in the dependences of the ablation efficiency and average ablation flow velocity on Φ{sub L}. For Φ{sub L} > Φ{sub opt}, the decrease in the function C{sub m}(Φ{sub L}) turns out to be much steeper than for metals and polymer materials. The difference is supposedly due to the lower strength and lower plasticity of the polycrystalline stone targets. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photon phase-space dynamics in a plasma wakefield accelerator

Frequency up-shifting of laser light in a beam-driven plasma wakefield has the potential to provide high-intensity sources of short wavelength radiation. Simulations have demonstrated that a laser pulse can undergo large frequency shifts, limited only by the drive beam energy, when the plasma density is tailored to match the accelerating phase of the wake to the group velocity of the pulse. Here, we study the dynamical evolution of photons in the 1D1P phase-space vicinity of the plasma wake-phase matching condition. Numerical calculations using a photon kinetic model are validated by direct comparison with 1D and quasi-3D particle-in-cell simulations. These calculations form the basis of a linear theory of the photon dynamics which reveals several important results, including scalings for the properties of the witness pulse and a self-similar solution for the photon phase-space dynamics. One prediction of the analytic theory is that the pulse can be compressed indefinitely, though the amount of compression would ultimately be limited by practical constraints. These results suggest that photon acceleration can provide a novel source of sub-femtosecond, short wavelength radiation.

XUV generation↗

Towards the optimization of direct laser acceleration

Experimental measurements using the OMEGA EP laser facility demonstrated direct laser acceleration (DLA) of electron beams to (505 ± 75) MeV with (140 ± 30) nC of charge from a low-density plasma target using a 400 J, picosecond duration pulse. Similar trends of electron energy with target density are also observed in self-consistent two-dimensional particle-in-cell simulations. The intensity of the laser pulse is sufficiently large that the electrons are rapidly expelled from along the laser pulse propagation axis to form a channel. The dominant acceleration mechanism is confirmed to be DLA and the effect of quasi-static channel fields on energetic electron dynamics is examined. A strong channel magnetic field, self-generated by the accelerated electrons, is found to play a comparable role to the transverse electric channel field in defining the boundary of electron motion.

43 PARTICLE ACCELERATORS↗

Tuning of electronic properties in highly lattice-mismatched epitaxial SmN

Here, we establish the relationship between native N vacancies, introduced through varying growth parameters, and the structural and transport properties in SmN thin films grown via molecular beam epitaxy grown on MgO(001). The varying levels of N vacancies introduced by varying the ratio of Sm to N atoms during deposition creates excess carriers that radically transform the electrical behavior of the film, over a range of five orders of magnitude, from highly resistive to highly conductive, and unlocking a phase transition evidenced by the presence of a ferromagnetic feature in resistivity. X-ray photoelectron spectroscopy results show that this effect is much less pronounced when varying the available nitrogen species. These samples retain a highly crystal quality despite being grown on a substrate with a lattice mismatch of 20%, alleviating the strain by forming a highly strained SmO oxide layer. The integration between SmN and several transition metal nitride compounds has the potential to unlock new architectures for Josephson junction devices.

36 - MATERIALS SCIENCE↗

Exploring Functional Materials by Understanding Beam‐Sample Interactions

Abstract Ultra‐low‐dose electron diffraction is performed with a double metal cyanide catalyst (DMC) to understand how electron irradiation stimulates structural alterations in functional materials. The commonly fading diffraction patterns with dose accumulation depend on the irradiated area and the beam current even when below 50 femto Amperes. Heat generation is observed and modeled by statistical, inelastic scattering events to describe how phonon excitations modulate radiation hardness. Specifically, the characteristic 1/e‐decay of Bragg intensities from DMC is delayed from 6 to 30 eÅ −2 at room temperature, which is comparable to the effect of embedding radiation soft matter in ice. DMC's radiation hardness is enhanced by a latency dose that forms during a phase transformation. This unifying model predicts that a critical dose rate exists for any material that varies between 0.1 and 10 4 eÅ −2 s −1 because of a material dependent competition of heat generation and spread. It shows that Brillouin scattering causes time dependent perturbations in electron irradiated solids that trigger time‐temperature‐transformations on a time scale of nanoseconds to microseconds at room temperature, which is not included in traditional models describing the decay of Bragg intensities by radiolysis.

Kisielowski, Christian↗

Holographic reflective Bragg gratings of gain and their role in the operation of high-power pulsed lasers

The influence of reflective Bragg gratings that are formed in an active medium due to the spatial periodic modulation of gain on the spectral properties of lasing are investigated by an example of a pulsed Nd : YAG laser. It is shown that, at a certain choice of the formation regime of reflective gratings of gain, the lasing bandwidth can be reduced by a factor of 3 – 5, with a corresponding increase in the pulse energy and significant improvement of spatial beam quality. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Understanding polaronic transport in complex oxides by combining precise synthesis and first-principles many-body theory

In complex oxides, charge carriers often couple strongly with lattice vibrations to form polarons–entangled electron–phonon quasiparticles whose transport properties remain difficult to characterize. Experimental access to intrinsic polaronic transport requires ultraclean samples, while theoretical description demands methods beyond low-order perturbation theory. Here, we show a predictive theory–experiment workflow to study polaron transport in complex oxides. Focusing on a prototypical polaronic oxide, anatase TiO 2 , we combine growth of high-quality oxygen-vacancy-doped films using hybrid molecular beam epitaxy with a first-principles electron–phonon diagrammatic Monte-Carlo (FEP-DMC) framework recently developed for accurate polaron predictions. Our films exhibit record-high electron mobility for anatase TiO 2 , in excellent agreement with FEP-DMC calculations conducted prior to experiment, which predict a room-temperature mobility of 45 ± 15 cm −2 V −1 s −1 and a mobility-temperature scaling of μ ∝ T −1.9 ± 0.077 . Microscopic analysis using scanning transmission electron microscopy and x-ray photoelectron spectroscopy reveals the role of oxygen vacancies in modulating transport at lower temperatures. FEP-DMC further provides quantitative insight into polaron formation energy, phonon cloud distribution, lattice distortion around the polaron, and the polaronic contribution to mobility. Together, these results provide a deeper microscopic understanding of large-polaron transport in a complex oxide and provide the blueprint to characterize other polaronic materials.

anatase TiO2↗

Dislocation Loops in Proton Irradiated Uranium-Nitrogen-Oxygen System

Here in this study, we investigated the dislocation loop types formed in the proton-irradiated uranium-nitrogen-oxygen (U-N-O) system, which involves uranium mononitride (UN), uranium sesquinitride (a-U2N3), and uranium dioxide (UO2) phases. The dislocation loop formation is examined using specimens irradiated at 400°C and 710°C. Based on the detailed transmission-based electron microscopy characterization with i) the morphology-based on-zone and ii) the invisibility-criterion based two-beam condition imaging techniques, only a single type of dislocation loop in each phase is found: a/2?110?, a/2?111?, or a/3?111? dislocation loops in UN, a-U2N3, and UO2 phases, respectively. Molecular statics calculations for the formation energy of perfect and faulted dislocation loops in UN phases indicate a critical loop size of ~ 6 nm, above which perfect loops are energetically favorable. This could explain the absence of faulted loops in the experimental observation of the irradiated UN phase at two temperatures. This work will enhance the understanding of irradiation induced microstructural evolution for uranium nitrides as advanced nuclear fuels for the next-generation nuclear reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Towards time-resolved MicroED grid preparation using mix-and-inject gas dynamic virtual nozzles

Recent progress in gas dynamic virtual nozzle (GDVN) technologies in combination with high-brilliance synchrotron and X-ray free-electron lasers (XFELs) has allowed the visualization of protein dynamics in crystallo by mixing macromolecular protein crystals with a substrate using tunable mixing times on the order of milliseconds to seconds prior to serial X-ray diffraction data collection. This has become the method of choice for high-resolution structure determination of intermediate states. However, such experiments require large counts of crystals of proper sizes for high-resolution data collection, and premium beam times for screening efforts. Cryogenic microcrystal electron diffraction (MicroED) represents a complementary technique that may be a more accessible avenue for time-resolved nanocrystallography compared with serial X-ray diffraction experiments. MicroED can produce full diffraction datasets from just a few submicrometre-thick crystals, and the approach is more readily accessible, requiring standard cryogenic transmission electron microscopy (TEM) equipment available at many universities and institutes. Cryogenic MicroED, like other forms of cryo-EM, begins with rapidly freezing biological material on electron microscopy grids. In the case of MicroED, micro- to nano-crystals (<500 nm thick) are deposited onto electron microscopy grids and plunge-frozen for subsequent electron diffraction data collection. Here, we have incorporated GDVN technology developed originally for XFEL experiments into the freezing process as a first step towards time-resolved studies. We describe the limited deposition efficiency of the model MicroED protein proteinase K on TEM grids using GDVNs, preceding sample vitrification and successful MicroED data collection. We discuss both the initial results from such experiments and the methodological challenges in developing this approach into a reliable workflow for millisecond-to-second time-resolved structural studies of macromolecules. Our results promise a strategy to deposit crystals on grids using GDVNs and determine high-resolution structures by MicroED, constituting a first step towards development of time-resolved MicroED experiments.

MicroED↗

A method for mapping submicron-scale crystallographic order/disorder applied to human tooth enamel

Tooth enamel, the outermost layer of human teeth, is a complex, hierarchically structured biocomposite. The details of this structure are important in multiple human health contexts, from understanding the progression of dental caries (tooth decay) to understanding the process of amelogenesis and related developmental defects. Enamel is composed primarily of long, nanoscale crystallites of hydroxyapatite that are bundled by the thousands to form micron-scale rods. Studies with transmission electron microscopy show the relationships between small groups of crystallites and X-ray diffraction characterize averages over many rods, but the direct measurement of variations in local crystallographic structure across and between enamel rods has been missing. Here, we describe a synchrotron X-ray-based experimental approach and a novel analysis method developed to address this gap in knowledge. A ~500-nm-wide beam of monochromatic X-rays in conjunction with a sample section only 1 μm in thickness enables 2D diffraction patterns to be collected from small well-separated volumes within the enamel microstructure but still probes enough crystallites (~300 per pattern) to extract population-level statistics on crystallographic features like lattice parameter, crystallite size, and orientation distributions. Furthermore, the development of a quantitative metric to characterize relative order and disorder based on the azimuthal autocorrelation of diffracted intensity enables these crystallographic measurements to be correlated with their location within the enamel microstructure (e.g., between rod and interrod regions). These methods represent a step forward in the characterization of human enamel and will elucidate the variation of the crystallographic structure across and between enamel rods for the first time.

crystallographic order/disorder↗

Cross Section Measurements of Photonuclear Reaction Pathways Towards Promising Medical Radioisotopes

Project Objectives: The goal of this project was to generate data relevant to radioisotope production while developing innovative technologies that foster and enhance novel production of radioisotopes, and, also, while providing opportunities for cultivating and training future generations of scientists. This work has provided the foundation for methodologies for determination of photonuclear cross sections over multiple energies in a single irradiation. Simultaneously, the feasibility of electron LINAC production of several in-demand radioisotopes such as 47 Sc, 67 Cu, 77 As, and 186 Re has been demonstrated. To accomplish these objectives a collaboration was formed between two complimentary facilities, the Low Energy Accelerator Facility (LEAF) at Argonne National Laboratory and the High Intensity Gamma-ray Source (HIGS) at Triangular Universities Nuclear Laboratory (TUNL). The involvement of the research group from North Carolina Central University gave students at this Historically Black University experience in forefront nuclear-physics research relevant to addressing a high-priority interdisciplinary issue. Project Description: HIGS provides a nearly monoenergetic gamma-ray beam by intra-cavity Compton backscattering of free-electron photons from electrons circulating in a storage ring. This beam can be collimated to produce a very precise energy beam. If the beam is un-collimated a calculated and precise energy spread of the beam occurs radially. The γ-flux can be evenly distributed over the radial distribution of energy and used to perform activation experiments on concentric ring targets. Thus providing multiple energy ranges in a single irradiation. Each concentric ring target can be counted separately in order to determine activation at the given energy and successively be correlated to the activation cross section. Targets were activated to determine production feasibility using electron beams at LEAF. Potential Impact: The Nuclear Science Advisory Committee recently named production of radioisotopes with electron LINACs as one of the most compelling and largest-impact opportunities for the production of high specific activity radioisotopes. Improving the photonuclear cross sectional data base with experimentally verified results will greatly enhance a researcher’s ability to rationalize electron LINAC production routes towards desired radioisotopes. This work will provide the foundation for methodologies for determination of photonuclear cross sections over multiple energies and multiple targets in a single irradiation. The techniques developed in this project will enable future studies to continue verifying theoretically predicted photonuclear cross section with experimental results. These data will also enable adaptation of models and support more precise theoretical calculation of photonuclear cross sections. This research will involve undergraduates, graduate students, and post-docs to give them a valuable research experience leading towards the next generation of scientists in the field of medical isotopes.

07 ISOTOPE AND RADIATION SOURCES↗

Formation of Nano- and Micro-Scale Surface Features Induced by Long-Range Femtosecond Filament Laser Ablation

In this work, we study the characteristics of femtosecond-filament-laser–matter interactions and laser-induced periodic surface structures (LIPSS) at a beam-propagation distance up to 55 m. The quantification of the periodicity of filament-induced self-organized surface structures was accomplished by SEM and AFM measurements combined with the use of discrete two-dimensional fast Fourier transform (2D-FFT) analysis, at different filament propagation distances. The results show that the size of the nano-scale surface features increased with ongoing laser filament processing and, further, periodic ripples started to form in the ablation-spot center after irradiation with five spatially overlapping pulses. The effective number of irradiating filament pulses per spot area affected the developing surface texture, with the period of the low spatial frequency LIPSS reducing notably at a high pulse number. The high regularity of the filament-induced ripples was verified by the demonstration of the angle-of-incidence-dependent diffraction of sunlight. This work underlines the potential of long-range femtosecond filamentation for energy delivery at remote distances, with suppressed diffraction and long depth focus, which can be used in biomimetic laser surface engineering and remote-sensing applications.

36 MATERIALS SCIENCE↗

Degradation of Poly- and Perfluoroalkyl Substances (PFAS) in Water via High Power, Energy-Efficient Electron Beam Accelerator

The goal of the 2-year workplan was to see if electron beam (EB) could be used to break down a sub-set of the larger chemical family of per and polyfluoroalkylated substances (PFAS) in an energy efficient and economical manner when compared to conventional water treatment technologies. Year one (Y1) work focused on sample EB treatment work in the Fermi National Accelerator Laboratory’s (FNALs) Accelerator Applications Demonstration and Development (A2D2) EB accelerator. While there are reportedly thousands of types of PFAS, for the point of most of the work herein, a small subset was examined, typically perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA). PFOA and PFOS are two of the most well studied PFAS and are studied for baseline evaluations and are considered most useful. The work from Y1 provided information about the optimal operating parameters and additives to use when treating PFOS and PFOA via EB. The data were then used to see where in a water treatment system an EB accelerator would be best suited to treat PFAS. A conventional water treatment technology, GAC, was then compared to e-beam treatment technology with respect to energy and costs for treatment. In year two (Y2), several conventional e-beam accelerator designs, and FNAL’s developmental compact SRF accelerator design, were evaluated for their suitability in PFAS treatment, from an energy efficiency and cost standpoint. Several EB parameters were evaluated and optimized for the removal of PFOA and PFOS from water at normal pressure and temperature, measured as total PFAS removal. Under the optimized test conditions both PFOA showed complete destruction to inorganic fluoride, and PFOS to inorganic fluoride and sulfate, with mass balance. The effect on PFAS removal relative to solution pH, total EB dose, EB dose rate, dissolved oxygen concentration (DO), temperature, and initial PFAS concentration were evaluated. In general, PFOA was easier to destroy than PFOS. Degradation products, typically observed under less-than-optimal EB conditions, provided insight to degradation mechanisms. Products were identified to rule out possible deleterious biproduct formation. The water radiolysis radical reaction kinetics with PFOS and PFOA were not dependent on the initial concentration over 5-orders of magnitude from 2 μg/L to 20 mg/L. This is thought to be because there was an overabundance of the reactive water radiolysis radicals relative to PFAS molecules and largely attributed to aqueous electrons. The reaction rates appeared to be diffusion limited. Testing at higher concentrations (100-200 mg/L) showed a decrease in removal efficiency, suggesting alternative kinetics, possibly second order rates, at higher concentrations. In all, we successfully defined a set of optimal EB parameters to treat PFOA and PFOS at concentrations of 20 mg/L in water with destruction efficiencies near 100%. We further tested the optimized EB parameters with other types of PFAS, including shorter and longer fluorocarbon chain homologs of PFOA and PFOS, and PFAS with alternative functional groups such as sulfonamides. Based on our results EB can be optimized as an effective destructive technology for removing PFAS from water. The conditions optimized for PFOA and PFOS were less effective with ultra-short fluorocarbon compounds like TFMS, PFES, PFPS and PFBS, and likely require re-optimization of parameters to them. In all, it was determined that from a cost and energy efficiency standpoint, EB would be best applied to waste streams with relatively high concentrations of PFOS and PFOA and is not as cost effective as GAC treatment for removing low concentrations of PFAS from water. Higher concentrations of PFAS can be found in the wastewater of conventional treatment processes such as RO and IE and therefore EB may be used to supplement such treatment technologies. Some real-world IE regeneration wash water and RO reject water containing higher concentrations of PFAS and obtained from pilot scale industrial wastewater treatment system at a fluorochemical manufacturing facility, showed that EB could remove PFAS from such types of wastewaters. The IE regenerant wash water appeared to be the most efficient of the two types of wastewaters tested. However, some further optimization of the EB parameters for the specific PFAS types present in those wastewaters may be required. Also, the effects of co-present TOC and mineral salts should be considered during such optimization efforts. From the experimental Y1 results it was seen that the aqueous electron drives degradation of the PFAS. In a hypothetical water treatment skid using EB for PFAS destruction the parameters of the system should be optimized to promote aqueous electron production. Before EB treatment, the PFAS should be preconcentrated when possible, the pH should be raised to pH 10 or higher to enhance aqueous electron production, and the water should be nitrogen purged to remove dissolved oxygen to minimize aqueous electron scavenging. An excel spreadsheet was created that calculates optimal conditions based on inlet PFAS concentration and desired outlet concentration, by optimizing the accelerator power, dose rate, water treatment rate, pH and dissolved oxygen levels to reach the desired endpoint. Given this information on accelerator operating conditions five different EB accelerator systems were compared. One EB system was a continuous-wave, linear superconducting accelerator being designed at Fermilab. Three other EB systems (IMPELA at 5% and 25% duty factor and the ILU-14) were normal conducting pulsed linear accelerators. The fifth system was an IBA Rhodotron which is a normal conducting, circular, continuous-wave accelerator. The accelerator efficiency (% of the incoming power that is used in water treatment) was the dominating factor in accelerator choice. The radio frequency (RF) power supply and the accelerator design (superconducting versus warm technology) drive the accelerator efficiency. The IBA Rhodotron was seen to be the most energy efficient commercially available technology with a wall-plug (total) power efficiency of 43% at 400 kW. The Fermilab design, with a prototype for a different application currently being fabricated, was the most energy efficient at 55% when driven by a Klystron RF power supply and as high as 77% when powered by a magnetron. As the Fermilab design was the most energy efficient by approximately 10-30%, further design work was done on the accelerator and beam delivery system specific to the destruction of PFAS in water. The Fermilab design is unique from industrial accelerators in that is superconducting. Superconducting technology allows for the acceleration of electrons without losses. The accelerator must be cooled to below the point where it is superconducting and is operated around 4 degrees Kelvin. The bulk of the design work for the accelerator is on making the accelerator as energy efficient as possible so that it does not require liquid helium and can be cooled with conduction cooling via cryocoolers. Final design work resulted in an EB accelerator that would operate at minimally 200 kW and 10 MeV. Prototype construction would cost $\$ $7.8 million dollars when driven by a Klystron power supply. A second version of the same accelerator would cost $\$ $5.5 million dollars when driven by a magnetron that is still under development. The commercially available 300 kW IBA Rhodotron cost was estimated at approximately $\$ $9 million. While it is hard to directly compare, an operational GAC system used by 3M for groundwater treatment capital cost (2022 dollars) was estimated to cost $\$ $3.3 million. While the capital expense of the EB accelerator systems was higher than GAC, the accelerator EB treatment would result in destruction of the PFAS and not just sequestration of PFAS to form a new waste stream that requires further treatment or disposal. The operating cost to destroy the PFAS via 400 kw EB system was less than $\$ $1000/kg of PFAS destroyed when treating at a 20 mg/L PFAS concentration, compared to GAC with operating costs that calculated at $\$ $27,530 per kg of PFAS sequestered when treating 100 μg/L PFOA and PFOS combined concentration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Femtosecond multimodal imaging with a laser-driven X-ray source

Laser-plasma accelerators are compact linear accelerators based on the interaction of high-power lasers with plasma to form accelerating structures up to 1000 times smaller than standard radiofrequency cavities, and they come with an embedded X-ray source, namely betatron source, with unique properties: small source size and femtosecond pulse duration. A still unexplored possibility to exploit the betatron source comes from combining it with imaging methods able to encode multiple information like transmission and phase into a single-shot acquisition approach. In this work, we combine edge illumination-beam tracking (EI-BT) with a betatron X-ray source and present the demonstration of multimodal imaging (transmission, refraction, and scattering) with a compact light source down to the femtosecond timescale. The advantage of EI-BT is that it allows multimodal X-ray imaging technique, granting access to transmission, refraction and scattering signals from standard low-coherence laboratory X-ray sources in a single shot.

43 PARTICLE ACCELERATORS↗

Fluid Flow Observations of The Spray Near-Field Using High-Speed X-Ray Imaging

Sprays are important to may industrial processes, but the near-field region where spray formation takes place is difficult to visualize and characterize through visible light imaging because this region is typically optically dense. X-ray imaging is one technique that can penetrate this optically dense region and provide unique observations of the spray formation process. This study uses high-speed white beam X-ray imaging conducted at the Advanced Photon Source to capture spray formation dynamics from a canonical airblast atomizer. In this work, a range of momentum flux ratios are visualized by varying the gas flow rate while the liquid flow rate is held constant. The use of X-rays show overlapping flow structures including bags, ligaments, mushrooms, and webs. Air bubbles are captured within the liquid regions, and a very dynamic crown forms at the liquid needle exit at higher momentum flux ratios. Finally, at the highest momentum flux ratios, air bubbles and liquid droplets are observed migrating upstream in the center of the crown, and this motion is attributed to a toroidal recirculation cell at the nozzle exit.

47 OTHER INSTRUMENTATION↗